OPTOTRONIC® Technical Information OTe 9/220-240/350 PC 350mA Constant Current LED Power Supply with Edition: Jan 2013 Subject to change PhaseCut functionality Technical data Reference: For LED modules: Nominal Voltage: OTe 9/220-240/350 PC 350 mA LED 220 – 240 VAC Line Current, nominal: Mains Frequency: Protection Class: Output Current: (Remark) Output voltage: (Remark) Output Power: (Remark) 56mA @ 230V 50/60 Hz II 350 mADC +/- 5% 17 VDC – 29 VDC Maximum < 32 VDC 10 W Partial Load 6W .. 10W ≥ 0,9 (full load) @ 230V > 0,85 (minimum load) @ 230V < 3 W max. ≥ 77% full load at 230V < 1,5 W No load condition 195 – 264 VAC Permitted voltage range No Rated Power factor: Power Loss: ECG efficiency: (Remark) Power Loss in no load condition (Remark): Input Voltage: (Remark) DC Voltage: Dimmable: Dimming Range: Yes Suitable for use with electronic leading- and trailing edge dimmer (Phase Cut) 10%.....100% No-load proof: Short circuit protection: Overload protection: Overtemperature protection: Yes Automatic, reversible Automatic, reversible Automatic, reversible Ambient temperature range, ta: Max. case temperature at tc point: ECG Lifetime: (Remark) Maximum casing temperature in case of fault -20 °C to +50 °C 65 °C 50.000h at tcase= 65 °C at tc point and 10% failure rate (Remark) 20130106 AA3526500DG 110°C Page 1 of 4 OPTOTRONIC® Technical Information OTe 9/220-240/350 PC 350mA Constant Current LED Power Supply with Edition: Jan 2013 Subject to change PhaseCut functionality Inrush current: (Remark) Max. no. of ECG @ circuit breakers 10 A (B type): Max. no. of ECG @ circuit breakers 16 A (B type): < 10 A twidth = 250 µs (measured at 50% Ipeak) 110 180 Terminal: Input: Screw terminals Output: Screw terminals Cable cross section input side 0,5 mm² – 2,5 mm² (Remark) Wire preparation length Input side: Solid and flexible 5,0 mm Cable cross section output side: 0,5 mm² – 2,5 mm² (Remark) Wire preparation length output side: Max. cable length - system: Geometry (l x b x h): Weight: IP Code: (Remark) Safety: Performance: Radio interference: Harmonic content: Immunity: Solid and flexible 5,0 mm 2m 109 x 53 x 33 mm ~ 100g IP20 Surge capability: Galvanic isolation primary/secondary : (Remark) Approvals: 20130106 AA3526500DG IEC 61347-1, IEC 61347-2-13 IEC 62384 CISPR 15 IEC 61000-3-2 IEC 61000-3-3 IEC 61547 L-N: 1kV 3,75 kVrms SELV-equivalent , Page 2 of 4 , OPTOTRONIC® Technical Information OTe 9/220-240/350 PC 350mA Constant Current LED Power Supply with Edition: Jan 2013 Subject to change PhaseCut functionality Geometry l = 109 mm, b = 53 mm, h = 33 mm OTe 9/220-240/350 PC Ordering information EAN 10 4008321978387 EAN 40 4008321978394 Typical Efficiency and Power Factor versus Load 20130106 AA3526500DG Page 3 of 4 OPTOTRONIC® Technical Information OTe 9/220-240/350 PC 350mA Constant Current LED Power Supply with Edition: Jan 2013 Subject to change PhaseCut functionality Earth connection Earth connection is not required. Installation notes The luminaire manufacturer is responsible for providing the required clearances and creepage distances and also for the protection against electrical shock, especially for the line and load wires according EN 60598. Ballast losses and LED Module heat radiation can lead to heat accumulation in a complete closed case. Therefore it is necessary to ensure, that the temperature at the measuring point t c does not exceed the maximum value. Instruction sheet Please consult the instruction sheet for further important information on e.g. wire stripping and wiring limitations in system installations. The instruction sheet is enclosed with the device or available upon request. 20130106 AA3526500DG Page 4 of 4