pdf

OPTOTRONIC®
Technical
Information
OTe 9/220-240/350 PC
350mA Constant Current LED Power Supply with Edition: Jan 2013
Subject to change
PhaseCut functionality
Technical data
Reference:
For LED modules:
Nominal Voltage:
OTe 9/220-240/350 PC
350 mA LED
220 – 240 VAC
Line Current, nominal:
Mains Frequency:
Protection Class:
Output Current:
(Remark)
Output voltage:
(Remark)
Output Power:
(Remark)
56mA @ 230V
50/60 Hz
II
350 mADC
+/- 5%
17 VDC – 29 VDC
Maximum < 32 VDC
10 W
Partial Load 6W .. 10W
≥ 0,9 (full load) @ 230V
> 0,85 (minimum load) @ 230V
< 3 W max.
≥ 77%
full load at 230V
< 1,5 W
No load condition
195 – 264 VAC
Permitted voltage range
No
Rated Power factor:
Power Loss:
ECG efficiency:
(Remark)
Power Loss in no load condition
(Remark):
Input Voltage:
(Remark)
DC Voltage:
Dimmable:
Dimming Range:
Yes
Suitable for use with electronic leading- and trailing
edge dimmer (Phase Cut)
10%.....100%
No-load proof:
Short circuit protection:
Overload protection:
Overtemperature protection:
Yes
Automatic, reversible
Automatic, reversible
Automatic, reversible
Ambient temperature range, ta:
Max. case temperature at tc point:
ECG Lifetime:
(Remark)
Maximum casing temperature in case
of fault
-20 °C to +50 °C
65 °C
50.000h
at tcase= 65 °C at tc point and 10% failure rate
(Remark)
20130106
AA3526500DG
110°C
Page 1 of 4
OPTOTRONIC®
Technical
Information
OTe 9/220-240/350 PC
350mA Constant Current LED Power Supply with Edition: Jan 2013
Subject to change
PhaseCut functionality
Inrush current:
(Remark)
Max. no. of ECG @ circuit breakers
10 A (B type):
Max. no. of ECG @ circuit breakers
16 A (B type):
< 10 A
twidth = 250 µs (measured at 50% Ipeak)
110
180
Terminal:
Input: Screw terminals
Output: Screw terminals
Cable cross section input side
0,5 mm² – 2,5 mm²
(Remark)
Wire preparation length Input side:
Solid and flexible
5,0 mm
Cable cross section output side:
0,5 mm² – 2,5 mm²
(Remark)
Wire preparation length output side:
Max. cable length - system:
Geometry (l x b x h):
Weight:
IP Code:
(Remark)
Safety:
Performance:
Radio interference:
Harmonic content:
Immunity:
Solid and flexible
5,0 mm
2m
109 x 53 x 33 mm
~ 100g
IP20
Surge capability:
Galvanic isolation
primary/secondary :
(Remark)
Approvals:
20130106
AA3526500DG
IEC 61347-1, IEC 61347-2-13
IEC 62384
CISPR 15
IEC 61000-3-2
IEC 61000-3-3
IEC 61547
L-N: 1kV
3,75 kVrms
SELV-equivalent
,
Page 2 of 4
,
OPTOTRONIC®
Technical
Information
OTe 9/220-240/350 PC
350mA Constant Current LED Power Supply with Edition: Jan 2013
Subject to change
PhaseCut functionality
Geometry
l = 109 mm, b = 53 mm, h = 33 mm
OTe 9/220-240/350 PC
Ordering information
EAN 10
4008321978387
EAN 40
4008321978394
Typical Efficiency and Power Factor versus Load
20130106
AA3526500DG
Page 3 of 4
OPTOTRONIC®
Technical
Information
OTe 9/220-240/350 PC
350mA Constant Current LED Power Supply with Edition: Jan 2013
Subject to change
PhaseCut functionality
Earth connection
Earth connection is not required.
Installation notes
The luminaire manufacturer is responsible for providing the required clearances and creepage
distances and also for the protection against electrical shock, especially for the line and load
wires according EN 60598.
Ballast losses and LED Module heat radiation can lead to heat accumulation in a complete
closed case. Therefore it is necessary to ensure, that the temperature at the measuring point t c
does not exceed the maximum value.
Instruction sheet
Please consult the instruction sheet for further important information on e.g. wire stripping and
wiring limitations in system installations. The instruction sheet is enclosed with the device or
available upon request.
20130106
AA3526500DG
Page 4 of 4