Technical Information OPTOTRONIC® OT 60/220-240/12 P Constant Voltage LED Power Supply for 12V Edition: Aug 2012 LED - Modules subject to change Technical data Reference: For LED modules: Nominal Voltage: Line current, nominal: Mains frequency: Protection Class: Output voltage: (Remark) Output Power: Rated Power factor: Power loss: ECG efficiency: (Remark) Power loss in no load condition: Input Voltage: (Remark) DC voltage operation: Inrush current: (Remark) Max. no. of ECG @ circuit breakers 10 A (B type): Max. no. of ECG @ circuit breakers 16 A (B type): Ambient temperature range, ta: Temperature range at storage Max. case temperature at tc point: ECG Life time: (Remark) Maximum casing temperature in case of fault: Dimmable: No-load proof: Short circuit protection: Overload protection: Overtemperature protection: 20120822 AA390770055 OT 60/220-240/12 P 12V LED Modules with respect to the output parameters: BackLED and BoxLED 220 – 240 VAC 0,32 A@230 V 50/60 Hz II 12,5V DC +/- 0,5V 60 W > 0,98 (full load) @ 230V > 0,93 (half load) @ 230V 9 W max. 86 % @ 230V full load at 230 V <1W 198 - 264 VAC Permitted Voltage Range No ≤ 35 A twidth = 170µs(measured at 50% Ipeak) 11 17 -25 °C to +55 °C -40 °C to +85°C +80°C 50.000h at tcase = +70 °C at t c point and 10% failure rate 100°C No Yes Automatic, reversible Automatic, reversible Automatic, reversible Page 1 of 3 Technical Information OPTOTRONIC® OT 60/220-240/12 2P Constant Voltage LED Power Supply for 12V Edition: Aug 2012 LED - Modules subject to change Cable cross section input side: side Cable cross section output put side: Cable types, Input side : (Remark) Cable types, Output side: (Remark) Wire preparation length, input side: side Wire preparation length, output side Max. cable length-system: Geometry (l x w x h) Mounting hole spacing, length: Mounting hole spacing, width (Remark) Weight: Casing: IP Code: Suitable for fixtures with protection class: ECG outdoor protection against humidity: Safety: Performance: Radio interference: Harmonic content: Immunity: Vibration tested: Surge capability Galvanic insulation primary/secondary: (Remark) 1,0 mm² / 17 AWG 1,0 mm²/ 17 AWG Flexible ~500 mm colour coding L: brown N: blue Flexible ~500 mm colour coding LEDModule (+): red LEDModule (-): ( black 10 mm 10 mm 10 m 180 x 50 x 34 mm³ 171 mm 14 mm Side mounting 12 mm 550 g Metal, aluminium IP67 II PCB fully encapsulated + dust proof metal housing IEC 61347-1, IEC 61347-2--13 IEC 62384 CISPR 15 IEC 61000-3-2 IEC 61547 Yes L-N: 3kV 3,75 kVrms, SELV - equivalent Approvals: 20120822 AA390770055 Page 2 of 3 Technical Information OPTOTRONIC® OT 60/220-240/12 P Constant Voltage LED Power Supply for 12V Edition: Aug 2012 LED - Modules subject to change Geometry l = 180 mm, l1 = 171 mm, w = 50 mm, w1 = 14 mm, h = 34 mm, h1 = 12 mm Ordering information OT 60/220-240/24 P EAN 10 4008321790811 EAN 40 4008321790828 Installation notes 1. The luminaire manufacturer is responsible for providing the required clearances and creepage distances and also for the protection against electrical shock, especially for the line and load wires. 2. Ballast losses and LED Module heat radiation can lead to heat accumulation in a complete closed case. Therefore it is necessary to ensure, that the temperature at the measuring point tc does not exceed the maximum value. Instruction sheet Please consult the instruction sheet for further important information on e.g. wire stripping and wiring limitations in system installations. The instruction sheet is enclosed with the device or available upon request. 20120822 AA390770055 Page 3 of 3