Lead Free

RoHS Compliant Solder Reflow Profile - SMD Trimpot® Products
Process
Description
Materials
1. Apply solder paste to
test board (8 - 10 mil thick)
Temperature
Time
Interval
• Sn 96.5 / Ag 3.0 / Cu 0.5
Room temperature
Alloy water soluble or no
clean solder paste
(see note 1)
• single sided epoxy glass
(G10) (UL approved)
• PC board approx. 4x4x.06 in.
2. Place test units onto board
6 units/board
3. Ramp up
Convection oven
A) Acceptable (see Figure 1)
(1) The solder connection wetting angle (solder to
component and solder to PCB termination)
does not exceed 90 °.
(see note 2)
2.5 °C ± 0.5 °/sec.
4. Preheat (TS)
150 °C to 190 °C
90 ± 30 sec.
5. Time above liquidus (TL)
220 °C
60-90 sec.
6. Peak temperature (TP)
250 °C +0 °/-5 °
10-20 sec. within
5 °C of peak
7. Ramp down
8. Cleaning water clean profile
High pressure deionized
water 60 PSI max.
B) Unacceptable (see Figure 2)
(1) Solder connection wetting angle exceeding
90 °.
(2) Incomplete reflow of solder paste.
(3) Dewetting.
3 °C ± 0.5 °C/sec.
If unacceptable, determine cause and correct prior to
next run.
72 °F to 160 °F
(22 °C to 71 °C)
As required
NOTES:
1. Parts are not hermetically sealed. The seal is to
withstand temporary exposure to board
processing.
2. Recommended to be cooled to room temperature
prior to board wash but must be below 40 °C.
Refer to ref. temperature profile. Temperature at
lead/pad junction with “K” type thermocouple.
(Derived using 6-zone Convection Oven)
3. Units that are board mounted for environmental
testing must see a peak temperature in the reflow
zone, as specified. This is to ensure that all test
units will see “worst case conditions”.
tp
TP
CRITICAL ZONE
T L TO TP
RAMP-UP
TL
tL
Temperature
(2) Solder balls that do not violate minimum
electrical clearances and are attached
(soldered) to a metal surface.
Room temperature
(see note 2)
Temperature of Lead/Pad Junction
4. Ramp down rate to be measured from 250 °C to
room temperature.
TS MAX.
RAMP-DOWN
TS MIN.
Inspect solder joint to determine if solder joint is
acceptable (i.e. exhibits wetting of joint’s surface).
Use the following criteria (ref. acceptability of printed
board assemblies, IPC-A-610):
5. Process Description 8 does not apply to open
frame trimmers.
ts
PREHEAT
6. Allow 3-6 inches minimum distance between the
nozzle head and the device.
TROOM
8 MINS./248.9 °C
t 25 *C TO PEAK
Time
90 °
90 °
FIGURE 1 - ACCEPTABLE
90 ° or < 90 °
> 90 °
< 90 °
FIGURE 2 - UNACCEPTABLE
> 90 °
REV. 02/13
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.