Reliability Report - International Rectifier

RELIABILITY REPORT 0220
RBV BRIDGE SERIES
QUALIFICATION REPORT
International Rectifier Corporation Italy
RELIABILITY LABORATORY
INTERNATIONAL RECTIFIER
CONTENTS
Section
1
Introduction and Purpose:
2
Issue:
3
Process Description:
4
Executive Summary:
5
Environmental Stress Test Plan:
6
Criteria for Qualification:
7
Summary of Environmental Stress Test Results on IR25XB06.
F.Giacosa
Reliability Engineer
G. Di Leo
Reliability & F/A Manager
Date Oct 2002
Issued by Reliability Laboratory
Page 2 of 2
INTERNATIONAL RECTIFIER
1. Introduction and Purpose:
The purpose of this qualification program is to produce test data and relevant information to
confirm that the 25 Amps. RBV bridge series devices, meet the requirements for Market
Introduction and IR internal Reliability Standards.
The test vehicles are IR25XB06.
The data and report are generated by IRCI Reliability Laboratory.
2. Issue:
The results collected in this report are sufficient to release a Final Qualification Approval of above
mentioned devices.
The Final Qualification Approval is justified by environmental testing, presented in this report, which
ensures that the product under consideration fulfils the requirements for Market Introduction and IRCI's
reliability requirements.
The Final Qualification is released for part number under mentioned:
All 25 Amp RBV Bridge series devices
3. Process Description:
The product family under consideration uses RBV package and standard assembly process.
4. Executive Summary:
Environmental testing was performed on 3 lots.
The lot was assembled in IR25XB06.
Environmental testing included:
Temperature Cycling Test (T/C).
High Temperature Blocking Life Test (HTRB)
5. Environmental Stress Test Plan:
Part Number
Stress
Test Conditions
Sample
Size/Lot
Lots
No
Read-out Intervals
IR25XB06
T/C
- 50° C / +150°C, 200 cycles
10
3
0, 50, 100, 200 cycles
IR25XB06
HTRB
600V @ 125 C, 1000 Hrs
0
10
3
0, 168, 500, 1000 hours
6. Criteria for qualification:
Devices are expected to perform with maximum one failure on these stresses.
Date Oct 2002
Issued by Reliability Laboratory
Page 3 of 3
INTERNATIONAL RECTIFIER
7. Summary of Environmental Stress Test Results:
7.1
Temperature Cycling Test (T/C)
7.1
TEMPERATURE CYCLING (T/C)
Test conditions :
Tc(min)= -50 °C
Tc(max)= +150 °C
30 minutes at each temperature extreme.
Test Completed after
200 Cycles
Measured parameter
Failure Criteria
VF @ IF max , Troom
VF increase more than 10% versus initial values
Irr @ Vrr max, Tj max
UBL
Part
Assy.Lot
Sample
Number
Number
Size
0
50
100
200
Failed
IR25XB06
F4
10
0
0
0
1
1
IR25XB06
F5
10
0
0
0
0
0
IR25XB06
F6
10
0
0
0
0
0
Date Oct 2002
No. of Test Failures @ cycles
Issued by Reliability Laboratory
Total Devices
Page 4 of 4
INTERNATIONAL RECTIFIER
7.2
High Temperature Blocking Life Test (HTRB)
7.2
HIGH TEMP. BLOCKING LIFE TEST (HTRB)
Test conditions :
Voltage = 600 Vpk
Tc(max) = +125 °C
Test Completed after
1000 Hours
Measured parameter
Failure Criteria
Irr @ Vrr max, Tj max
Irr increase more than 400% versus initial values
VF @ IF max , Troom
UBL
Part
Assy
Number
Site
IR25XB06
IRINDIA
IR25XB06
IR25XB06
LOT NO
Sample
Number of Test Failures @ hours
Size
0
168
500
1000
Total
B01219-4C New (T11)
10
0
0
0
0
0
IRINDIA
B011219-4C New + Pre soldering
(T17)
10
0
0
0
0
0
IRINDIA
K0201040024 + Pre soldering (T14)
10
0
0
0
0
0
(Refer report # 222 dated 28th may 2002)
Date Oct 2002
Issued by Reliability Laboratory
Page 5 of 5