Soldering Profile - RoHS Compliant SMD Trimmers

RoHS Compliant Solder Reflow Profile - SMD Trimpot® Products
Process
Description
1. Apply solder paste to
test board (8 - 10 mil thick)
Materials
Temperature
• Sn 96.5 / Ag 3.0 / Cu 0.5
Alloy water soluble or no
clean solder paste
(see note 1)
Room temperature
Time
Interval
A) Acceptable (see Figure 1)
2. Place test units onto board
3. Ramp up
(see note 2)
2.5 °C ± 0.5 °/sec.
4. Preheat (TS)
Convection oven
150 °C to 190 °C
90 ± 30 sec.
5. Time above liquidus (TL)
220 °C
60-90 sec.
6. Peak temperature (TP)
250 °C +0 °/-5 °
10-20 sec. within
5 °C of peak
7. Ramp down
8. Cleaning water clean profile
Inspect solder joint to determine if solder joint is
acceptable (i.e. exhibits wetting of joint’s surface).
Use the following criteria (ref. acceptability of printed
board assemblies, IPC-A-610):
High pressure deionized
water 60 PSI max.
Room temperature
(see note 2)
3 °C ± 0.5 °C/sec.
72 °F to 160 °F
(22 °C to 71 °C)
As required
(1) The solder connection wetting angle (solder to
component and solder to PCB termination)
does not exceed 90 °.
(2) Solder balls that do not violate minimum
electrical clearances and are attached
(soldered) to a metal surface.
B) Unacceptable (see Figure 2)
(1) Solder connection wetting angle exceeding
90 °.
(2) Incomplete reflow of solder paste.
(3) Dewetting.
If unacceptable, determine cause and correct prior to
next run.
NOTES:
Temperature of Lead/Pad Junction
1. Parts are not hermetically sealed. The seal is to
withstand temporary exposure to board
processing.
(Derived using 6-zone Convection Oven)
2. Recommended to be cooled to room temperature
prior to board wash but must be below 40 °C.
Refer to ref. temperature profile. Temperature at
lead/pad junction with “K” type thermocouple.
tp
TP
CRITICAL ZONE
T L TO TP
RAMP-UP
3. Units that are board mounted for environmental
testing must see a peak temperature in the reflow
zone, as specified. This is to ensure that all test
units will see “worst case conditions”.
TL
Temperature
tL
TS MAX.
RAMP-DOWN
TS MIN.
4. Ramp down rate to be measured from 250 °C to
room temperature.
ts
PREHEAT
5. Process Description 8 does not apply to open
frame trimmers.
TROOM
6. Allow 3-6 inches minimum distance between the
nozzle head and the device.
8 MINUTES MAX.
t 25 *C TO PEAK
Time
90 °
90 °
FIGURE 1 - ACCEPTABLE
90 ° or < 90 °
> 90 °
> 90 °
FIGURE 2 - UNACCEPTABLE
> 90 °
REV. 06/16
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.