Standard Wiring Example of Main Circuit • Fra • Frame A, B • In Case of Single Phase, 100V L1 L3 L1C L2C External regenerative resistor 172167-1 Tyco Electronics AMP Red 1 White 2 Black 3 Green 4 MC NFB Control power supply ON OFF ALM MC Surge absorber MC L L1 L3 L1C L2C Use a reactor for 3-phase CN X2 RB1 RB3 RB2 U V W 1 2 3 4 Built-in thermostat of an external regenerative resistor (light yellow) CN X1 Main power supply MC L Noise filter NFB ON OFF ALM MC Surge absorber Noise filter Built-in thermostat of an external regenerative resistor (light yellow) • In Case of Single Phase, 200V External regenerative resistor 172167-1 Tyco Electronics AMP Red 1 White 2 Black 3 Green 4 Motor connection Motor RB1 RB3 RB2 U V W 1 2 3 4 MC CN X1 Main power supply Control power supply CN X2 Motor connection Motor 172159-1 Tyco Electronics AMP DC12 to 24V (±5%) ALM 37 CN X5 ALM 172159-1 Tyco Electronics AMP DC12 to 24V (±5%) ALM+ 36 ALM– 37 CN X5 ALM+ 36 ALM– • Frame C, D • In Case of Single Phase, 200V • In Case of 3-Phase, 200V Built-in thermostat of an external regenerative resistor (light yellow) ON OFF ALM MC MC Surge absorber CN X1 MC L NFB Noise filter L1 L2 L3 Use a reactor for 3-phase (Remove the short wire when you connect the external regenerative resistor.) External regenerative resistor 172167-1 Tyco Electronics AMP Red 1 White 2 Black 3 Green 4 RB1 RB3 RB2 U V W *1 2 3 4 DC12 to 24V (±5%) * When you use motor model of MSMA, MDMA, MFMA, MHMA and MGMA, use the connections as the right table shows.. L1 L2 L3 L1C L2C Control power supply (Remove the short wire when you connect the external regenerative resistor.) CN X2 External regenerative resistor 172167-1 Tyco Electronics AMP Red 1 White 2 Black 3 Green 4 RB1 RB3 RB2 *1 Motor connection Main power supply Control power supply CN X2 U 2 3 4 V W Motor connection Motor Motor 172159-1 Tyco Electronics AMP CN X1 MC L NFB Main power supply L1C L2C Built-in thermostat of an external regenerative resistor (light yellow) ON OFF ALM MC MC Surge absorber <Remarks> When you use single phase, connect the main power between L1 and L3 terminals. Noise filter <Remarks> When you use single phase, connect the main power between L1 and L3 terminals. ALM 37 172159-1 Tyco Electronics AMP CN X5 ALM+ DC12 to 24V (±5%) 36 ALM– D ALM A PIN No. G C B H JL04V-2E20-4PE-B-R G H A A JL04HV-2E22-22PE-B-R F F I B [Motor portion] PIN No. Application I Connector : A U-phase B E D C V-phase B E by Japan Aviation Electronics Ind. JL04V-2E20-18PE-B-R W-phase C D <Remark> Ground D C Do not connect anything to NC. A4-69 Application Brake Brake NC U-phase V-phase W-phase Ground Ground NC 37 CN X5 ALM+ 36 ALM– PIN No. A B A B C C D D E F E F G H I G JL04V-2E24-11PE-B-R H I Application Brake Brake NC U-phase V-phase W-phase Ground Ground NC Standard Wiring Example of Main Circuit MINAS A4P • Frame E, F Buiilt-in thermostat of external regenerative resistor (light yellow) ALM ON MC OFF MC Surge absorber L MC NFB L1 Noise filter Power supply (3-phase) Main power supply connection L2 L3 Control power supply connection r t (Connect these at normal operation) P B1 External regenerative resistor B2 U Motor connection V W * Cannon Connector ALM DC12 to 24V (± 5%) Motor 37 36 ALM+ ALM- [Motor portion] D A C B JL04V-2E20-4PE-B-R JL04HV-2E22-22PE-B-R G H F A I E D PIN No. Application A U-phase V-phase B W-phase C Ground D A B B D C C E G H F I JL04V-2E20-18PE-B-R JL04V-2E24-11PE-B-R PIN No. Application G Brake H Brake A NC F U-phase I V-phase B W-phase E Ground D Ground C NC PIN No. Application A Brake Brake B NC C U-phase D V-phase E W-phase F Ground G Ground H NC I <Remark> Do not connect anything to NC. A4-70 MINAS A4P Standard Wiring Example of Main Circuit * One of the following connections applies in accordance with the series of motors. Refer to "Connector and Plug Specifications" on page A4-142.