pdf

www.osram.com
PARATHOM® PRO PAR16 35 advanced
Product description
•
Replacement for 35W halogen lamp in GU10
•
Dimmable
•
Long lifetime
•
High light quality with CRI 90 and fine binning
•
Small form factor
Product Offering
Type reference
PAR16 35 24° adv 927
PAR16 35 36° adv 927
PAR16 35 36° adv 930
PAR16 35 36° adv 840
Power
5.2W
5.2W
5.2W
5.2W
1. Key Features and Benefits
• 5.2W LED lamp as high-quality replacement of 35-50W halogen lamp
• GU10 base
• 220-240V AC input voltage
1
• Dimmable
• avaible in three different colour temperature:
2700K – warm white
3000K – warm white
4000K – cool white
• high colour consistency: <4 Standard Deviation Colour Matching
• reduces energy consumption up to 85%
• shock-proof and vibration-proof
• 50,000 hours lifetime
• UV and NIR radiation free
• Mercury free
2
• 5 years Osram Guarantee
1
2
See www.osram.com/dim
See www.osram.com/guarantee
GL MK, Edition April 2013
subject to alteration
1
CCT
2700K
2700K
3000K
4000K
Beam Angle
25°
35°
35°
35°
CRI
90
90
90
90
3
2. Common Characteristics
Average lifetime4
Switching cycles
Casing material
Starting time
(30s on, 30s off)
50,000h
1,000,000
Metal/plastic
Mercury
max.
Base Type
Length
Diameter
0.0mg
GU10
58mm
50mm
3. Characteristic Range
Type reference
>0.5s
Weight
Tc temperature
max.5
72g
80°C
Warm up time
for 60% light
Power factor
>2
Nominal current
>0.8
Max. current
0.03A
5A
3
Power
Luminous
flux
Luminous
intensity
Correlated colour
temperature
Standard deviation
colour matching
Colour
renderix
index
Beam
angle
PAR16 35 24 adv
927
5.2W
230lm
900cd
2700K
<4
90
24°
PAR16 35 36 adv
927
5.2W
230lm
600cd
2700K
<4
90
36°
PAR16 35 36 adv
930
5.2W
230lm
600cd
3000K
<4
90
36°
PAR16 35 36adv
940
5.2W
230lm
600cd
4000K
<4
90
36°
4. Technical information
3000K, 35° version
3000K, 25° version
5. Mounting information
Good heat exchange supports ideal performance
Tc-point
Tc-Point
3
Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical
values given above for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of
an individual product; individual products may vary from the typical values.
4
The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical lamps goes below 70% of
its initial luminous flux (L70B50, IEC60969).The lifetime is estimated at room temperature (25°C), free air burning, base up burning position and at rated
voltage. To achieve a full lifetime a good heat exchange for the electronic components is required.
5
The Tc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated position) under normal
operating conditions and at the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01)
GL MK, Edition April 2013
subject to alteration
2
6. Disposal information
WEEE-lamps can be returned at specific collection
points.
LED lamps have to be disposed as special waste.
7. Application Information
Applications
•
hotels
•
restaurant
•
commercial areas
•
residentials
•
art galleries and museum
•
office space
Application Notes
1. suitable for indoor application.
2. for outdoor applications and operation in damp
locations special approved fixture are
required.
3. Operating temperature range between -20°C
and 40°C
8. Cost savings: example
Reference product
description
Similar halogen product
Watts saved
PAR16 35 35 adv 830
HAL GU10 35W
29.8
Cost saved
after 1 year
Cost saved
after 2 years
12€
Cost saved
after 3 years
50€
88€
Based on the assumption of 12hours/day on and an energy cost of 0.19€/kWh
9. Ordering Guide
Type reference
Product Number – 1pcs
Product Number – 1 shipping unit
Number of pcs / ship. unit
PAR16 35 25 adv 927
4052899902213
4052899902336
10
PAR16 35 35 adv 927
4052899902367
4008321856050
10
PAR16 35 35 adv 930
4052899902374
4008321856067
10
PAR16 35 35 adv 940
4052899902381
4008321856074
10
10. Lamp conformity
2004/108/EC Electromagnetic compatibility (EMC)
2009/125/EC Ecodesign requirements for energy related products
2011/65/EC Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
1907/2006 Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH Regulation)
2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)
EN 62471 Photobiological safety of lamps and lamp systems
IEC/TR 62471-2 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufactoring requirements relating to
non-laser optical radiation safety
EN 55015 Limits and methods of measurement of radio disturance
EN 61000-3-2 Electromagnetic compatibility – Limits for harmonic current emission
EN 61000-3-3 Electromagnetic compatibility – Limitation of voltage changes, voltage fluactuations, flicker in public low voltage
supply systems
EN61547 Electromagnetic compatibility immunity requirements
2006/95/EC Electrical equipment designed for use within certain valtage limits
EN 62560 Self ballasted LED-lamps for general lighting services by voltage >50V - Safety specifications
GL MK, Edition April 2013
subject to alteration
3
11. Dimming behaviours
6
Legend
L / leading edge
T / trailing edge
Y / yes
N / no
Dimming behaviour @ Vin= 230V, 50Hz
Note
Number
of lamp
Dimmer info
under test
Type
Dimming range
(%)
Min
Max
1
10
100
L
1
27
100
2875
L
1
20
100
28 198989
L
1
0
100
Berker
2819
L
1
38
100
Berker
2861 10
U
1
0
0
Brand
Model
ABB
STD 503
L
be
T10
Becker
Berker
British General
L
1
20
100
Busch-Jäger
6517-0-0016
L
1
0
100
Busch-Jäger
6519 U
T
1
14
100
Busch-Jäger
6513 U-102
T
1
14
100
Busch-Jäger
2247 U
L
1
7
100
Conrad
TDS 1300
L
1
7
100
Düwi
DW700DA
L
1
34
100
Elso
174100
L
1
10
100
Everflourish
EFO700DC
T
1
15
100
Everflourish GA
622518
L
1
31
100
Feller
40300.RC.FMI.61
T
1
13
100
Gira
0307 00 F02
T
1
10
100
Gira
0300 00 / I01
L
38
100
Gira
117600
U
1
1
0
0
Hager
WUD43
U
0
0
He
T46
T
1
16
100
HK
8085
1
16
100
Inter Union
EMI 585
T
1
5
100
Jung
225 NVDE
L
1
12
99
Jung
254 UDIE 1
U
0
0
Jung
255 NV DE
L
1
1
7
100
Kopp
80.78
T
1
10
100
Legrand
775903
U
9
85
Merten
5771
T
1
1
15
100
PEHA
434
L
1
10
100
PEHA
434 HAN
L
1
7
100
Schneider Electronic
315
T
1
0
0
Schneider Electronic
STD400T RC/RL
U
9
100
Siemens
5TC8284
T
1
1
29
100
Up Lighting
H153845
L
12
100
1
1
6
Lamp does not light up
high noise from the dimmer
Lamp does not light up
Lamp does not light up
high noise from the dimmer
Lamp does not light up
Lamp does not light up
Typical values. Test performed exemplary on PARATHOM PRO Par16 35
The test results reflect the measurement of the individual devices that were used in tests. OSRAM does not take over any responsibility, warranty or liability that this results can also be achieved by
using the devices under other conditions or when using successor models of the tested devices or different models of the same manufacturer.
The test results were achieved by using the above mentioned LED-lamp types. OSRAM does not take over any responsibility, warranty or liability that this results can also be achieved by using the
devices under other conditions or when using other LED-lamp types.
GL MK, Edition April 2013
subject to alteration
4