www.osram.com PARATHOM® PRO PAR16 35 advanced Product description • Replacement for 35W halogen lamp in GU10 • Dimmable • Long lifetime • High light quality with CRI 90 and fine binning • Small form factor Product Offering Type reference PAR16 35 24° adv 927 PAR16 35 36° adv 927 PAR16 35 36° adv 930 PAR16 35 36° adv 840 Power 5.2W 5.2W 5.2W 5.2W 1. Key Features and Benefits • 5.2W LED lamp as high-quality replacement of 35-50W halogen lamp • GU10 base • 220-240V AC input voltage 1 • Dimmable • avaible in three different colour temperature: 2700K – warm white 3000K – warm white 4000K – cool white • high colour consistency: <4 Standard Deviation Colour Matching • reduces energy consumption up to 85% • shock-proof and vibration-proof • 50,000 hours lifetime • UV and NIR radiation free • Mercury free 2 • 5 years Osram Guarantee 1 2 See www.osram.com/dim See www.osram.com/guarantee GL MK, Edition April 2013 subject to alteration 1 CCT 2700K 2700K 3000K 4000K Beam Angle 25° 35° 35° 35° CRI 90 90 90 90 3 2. Common Characteristics Average lifetime4 Switching cycles Casing material Starting time (30s on, 30s off) 50,000h 1,000,000 Metal/plastic Mercury max. Base Type Length Diameter 0.0mg GU10 58mm 50mm 3. Characteristic Range Type reference >0.5s Weight Tc temperature max.5 72g 80°C Warm up time for 60% light Power factor >2 Nominal current >0.8 Max. current 0.03A 5A 3 Power Luminous flux Luminous intensity Correlated colour temperature Standard deviation colour matching Colour renderix index Beam angle PAR16 35 24 adv 927 5.2W 230lm 900cd 2700K <4 90 24° PAR16 35 36 adv 927 5.2W 230lm 600cd 2700K <4 90 36° PAR16 35 36 adv 930 5.2W 230lm 600cd 3000K <4 90 36° PAR16 35 36adv 940 5.2W 230lm 600cd 4000K <4 90 36° 4. Technical information 3000K, 35° version 3000K, 25° version 5. Mounting information Good heat exchange supports ideal performance Tc-point Tc-Point 3 Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical values given above for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an individual product; individual products may vary from the typical values. 4 The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical lamps goes below 70% of its initial luminous flux (L70B50, IEC60969).The lifetime is estimated at room temperature (25°C), free air burning, base up burning position and at rated voltage. To achieve a full lifetime a good heat exchange for the electronic components is required. 5 The Tc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated position) under normal operating conditions and at the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01) GL MK, Edition April 2013 subject to alteration 2 6. Disposal information WEEE-lamps can be returned at specific collection points. LED lamps have to be disposed as special waste. 7. Application Information Applications • hotels • restaurant • commercial areas • residentials • art galleries and museum • office space Application Notes 1. suitable for indoor application. 2. for outdoor applications and operation in damp locations special approved fixture are required. 3. Operating temperature range between -20°C and 40°C 8. Cost savings: example Reference product description Similar halogen product Watts saved PAR16 35 35 adv 830 HAL GU10 35W 29.8 Cost saved after 1 year Cost saved after 2 years 12€ Cost saved after 3 years 50€ 88€ Based on the assumption of 12hours/day on and an energy cost of 0.19€/kWh 9. Ordering Guide Type reference Product Number – 1pcs Product Number – 1 shipping unit Number of pcs / ship. unit PAR16 35 25 adv 927 4052899902213 4052899902336 10 PAR16 35 35 adv 927 4052899902367 4008321856050 10 PAR16 35 35 adv 930 4052899902374 4008321856067 10 PAR16 35 35 adv 940 4052899902381 4008321856074 10 10. Lamp conformity 2004/108/EC Electromagnetic compatibility (EMC) 2009/125/EC Ecodesign requirements for energy related products 2011/65/EC Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 1907/2006 Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH Regulation) 2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE) EN 62471 Photobiological safety of lamps and lamp systems IEC/TR 62471-2 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufactoring requirements relating to non-laser optical radiation safety EN 55015 Limits and methods of measurement of radio disturance EN 61000-3-2 Electromagnetic compatibility – Limits for harmonic current emission EN 61000-3-3 Electromagnetic compatibility – Limitation of voltage changes, voltage fluactuations, flicker in public low voltage supply systems EN61547 Electromagnetic compatibility immunity requirements 2006/95/EC Electrical equipment designed for use within certain valtage limits EN 62560 Self ballasted LED-lamps for general lighting services by voltage >50V - Safety specifications GL MK, Edition April 2013 subject to alteration 3 11. Dimming behaviours 6 Legend L / leading edge T / trailing edge Y / yes N / no Dimming behaviour @ Vin= 230V, 50Hz Note Number of lamp Dimmer info under test Type Dimming range (%) Min Max 1 10 100 L 1 27 100 2875 L 1 20 100 28 198989 L 1 0 100 Berker 2819 L 1 38 100 Berker 2861 10 U 1 0 0 Brand Model ABB STD 503 L be T10 Becker Berker British General L 1 20 100 Busch-Jäger 6517-0-0016 L 1 0 100 Busch-Jäger 6519 U T 1 14 100 Busch-Jäger 6513 U-102 T 1 14 100 Busch-Jäger 2247 U L 1 7 100 Conrad TDS 1300 L 1 7 100 Düwi DW700DA L 1 34 100 Elso 174100 L 1 10 100 Everflourish EFO700DC T 1 15 100 Everflourish GA 622518 L 1 31 100 Feller 40300.RC.FMI.61 T 1 13 100 Gira 0307 00 F02 T 1 10 100 Gira 0300 00 / I01 L 38 100 Gira 117600 U 1 1 0 0 Hager WUD43 U 0 0 He T46 T 1 16 100 HK 8085 1 16 100 Inter Union EMI 585 T 1 5 100 Jung 225 NVDE L 1 12 99 Jung 254 UDIE 1 U 0 0 Jung 255 NV DE L 1 1 7 100 Kopp 80.78 T 1 10 100 Legrand 775903 U 9 85 Merten 5771 T 1 1 15 100 PEHA 434 L 1 10 100 PEHA 434 HAN L 1 7 100 Schneider Electronic 315 T 1 0 0 Schneider Electronic STD400T RC/RL U 9 100 Siemens 5TC8284 T 1 1 29 100 Up Lighting H153845 L 12 100 1 1 6 Lamp does not light up high noise from the dimmer Lamp does not light up Lamp does not light up high noise from the dimmer Lamp does not light up Lamp does not light up Typical values. Test performed exemplary on PARATHOM PRO Par16 35 The test results reflect the measurement of the individual devices that were used in tests. OSRAM does not take over any responsibility, warranty or liability that this results can also be achieved by using the devices under other conditions or when using successor models of the tested devices or different models of the same manufacturer. The test results were achieved by using the above mentioned LED-lamp types. OSRAM does not take over any responsibility, warranty or liability that this results can also be achieved by using the devices under other conditions or when using other LED-lamp types. GL MK, Edition April 2013 subject to alteration 4