NEC Express5800/E120d-M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. October 25, 2013 Revision 5.0 NEC Corporation CONFIGURATION GUIDE – NEC Express5800/E120d-M Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views for Server Module Enclosure ......................................................................... 5 Front and Rear Views for Server Module............................................................................................ 6 Dimensions (mm) .................................................................................................................................. 7 CONFIGURATION DIAGRAM ......................................................................................... 8 EXPANSION SLOT .......................................................................................................... 9 SERVER CONFIGURATION ......................................................................................... 10 1 2 3 4 5 6 7 8 9 Maximum Server Module Configuration ........................................................................................ 10 Server Module Enclosure ............................................................................................................ 10 1.1 Server Module Enclosure .................................................................................................. 10 1.2 Options for Server Module Enclosure ................................................................................ 11 Server Module .............................................................................................................................. 11 Processors and Heat Sink .......................................................................................................... 11 Memory ......................................................................................................................................... 12 Internal Hard Disk Drives ............................................................................................................ 14 5.1 RAID Configuration ............................................................................................................ 14 5.2 Internal Drive Configuration ............................................................................................... 14 Optical Drive ................................................................................................................................. 18 PCI Riser Card / PCI Card ........................................................................................................... 18 7.1 Network Interface Controller .............................................................................................. 18 7.2 InfiniBand ........................................................................................................................... 19 7.3 External Storage Controller ............................................................................................... 20 Other Add-in Components .......................................................................................................... 20 8.1 Flash FDD .......................................................................................................................... 20 Add-on Components ................................................................................................................... 21 9.1 17-inch LCD Console Drawer ............................................................................................ 21 9.2 KVM Switch ........................................................................................................................ 21 9.3 Server Management License ............................................................................................. 22 REFERENCES............................................................................................................... 23 Server Management ............................................................................................................................ 23 OS Support Matrix for PCI Cards and Embedded Controller ......................................................... 24 Supported PCI Cards and Installable Slots ...................................................................................... 25 Tested Linux Operating Systems ...................................................................................................... 26 Copyright Notice and Liability Disclaimer ........................................................................................ 27 REVISION HISTORY ..................................................................................................... 28 NEC Corporation Revision 5.0 – October 25, 2013 2 CONFIGURATION GUIDE – NEC Express5800/E120d-M Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2400 product family Up to 384 GB of memory capacity, supporting high speed and energy efficient DDR3-1600 memory High reliable with redundant fan Specification Server Module Model Part Number Processor E120d-M Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Internal Storage Type Standard Capacity Maximum Capacity Memory protection Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Disk Drive Bays Expansion Slots Video Controller (VRAM) Resolution / Color Interfaces Server Management Redundant Fan Power (Max. Config, Idling) Consumption (Max. Config, Operating) Acoustic Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 2 Level) NEC Corporation N8100-1908F, N8100-1909F Intel® Intel® Intel® Intel® Intel® Xeon® Xeon® Xeon® Xeon® Xeon® Processor Processor Processor Processor Processor E5-2407 E5-2430 E5-2430L E5-2450L E5-2470 2.20 GHz 2.20 GHz 2 GHz 1.80 GHz 2.30 GHz 1 to 2 10 MB 15 MB 20 MB 4C / 4T 6C / 12T 8C / 16T Intel® C602 Chipset DDR3-1600 ECC Unbuffered Low Power DIMM, DDR3-1600 and DDR3-1066 ECC Registered Low Power DIMM 0 GB 384 GB (12 x 32 GB) ECC, x4 SDDC 0 GB SATA HDD : 4 TB (4 x 1 TB) SAS HDD : 4.8 TB (4 x 1.2 TB) SAS SSD : 1.6 TB (4 x 400 GB) SATA : 3Gb/s and 6Gb/s (Integrated) SAS: 6Gb/s (Optional) RAID 0/1/5/6/10 (Optional) Supported 4 Total: 2 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) for a flexible integrated NIC Integrated in Server Management Controller (32MB) 1 1280 x 1024 / 16.7M 1 VGA (15-pin mini D-sub, 1 front) 3 USB2.0 (2 front, 1 internal) 1 Serial (9-pin mini D-sub, RS232-C, 1 rear) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for Management (RJ-45, 1 rear) EXPRESSSCOPE Engine 3 Standard, non-hot plug 127 Watt 133 Watt 131 Watt 132 Watt 132 Watt 249 Watt 357 Watt 45.7dB 59.9dB Revision 5.0 – October 25, 2013 292 Watt 45.7dB 58.6dB 311 Watt 383 Watt 45.7dB 59.9dB 3 CONFIGURATION GUIDE – NEC Express5800/E120d-M Model E120d-M Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) 220.0 × 780.0 × 40.0 mm / 8.66 x 30.7 x 1.5 in 5 kg / 7 kg, 11.02 lbs. / 15.43 lbs. 3 3 Operating: 10° to 40° C / 50° to 104° F , 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, C-TICK, CE, UL, CB, RoHS, WEEE Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 4 Microsoft® Windows Server® 2012 Standard 4 Microsoft® Windows Server® 2012 Datacenter 5 Red Hat Enterprise Linux 5.8 or later (x86) 5 Red Hat Enterprise Linux 5.8 or later (EM64T) 5 Red Hat Enterprise Linux 6.2 or later (x86) 5 Red Hat Enterprise Linux 6.2 or later (x86_64) VMware ESX 4.1 Update 2 VMware ESXi 5.0 Update 1 VMware ESXi 5.1 6 VMware ESXi 5.5 Regulatory and Safety Operating Systems 1 2 3 4 5 6 Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may vary by the operating environment. Maximum temperature depends on the server configuration. Refer to the Maximum Server Module Configuration for detail. For Windows Server 2012 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html Available in November 2013. Server Module Enclosure Model Server Module Enclosure Part Number Server Module Bays Power Supply Bays Redundant Fan Redundant Power Supply Power Supply N8141-62F 4 2 Standard, hot plug 2 x 1,000 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 100 VAC : 1,247 VA / 1,185 Watt 200 VAC : 1,416 VA / 1,345 Watt 100 VAC : 4,266 kJ/h 200 VAC : 4,842 kJ/h 447.0 x 780.0 x 87.0 mm / 17.5 x 30.7 x 3.4 in (2U) 13 kg / 41 kg, 28.66 lbs. / 901.38 lbs. Operating: 10° to 40° C / 50° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% RoHS Maximum Power Consumption Heat Dissipation Dimensions (W x D x H ) 1 Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety 1 The weight was measured with the following system configurations: Minimum: Server Module Enclosure with two power supplies Maximum : Server Module Enclosure with two power supplies and four server modules with maximum configuration NEC Corporation Revision 5.0 – October 25, 2013 4 CONFIGURATION GUIDE – NEC Express5800/E120d-M External Views Front and Rear Views for Server Module Enclosure Front View A B C D Legend A. B. C. D. Module Slot #1 Module Slot #2 Module Slot #3 Module Slot #4 Rear View B E A D F C Legend A. B. C. Module Slot #1 Module Slot #2 Module Slot #3 NEC Corporation D. E. F. Module Slot #4 Power Supply Slot #1 Power Supply Slot #2 Revision 5.0 – October 25, 2013 5 CONFIGURATION GUIDE – NEC Express5800/E120d-M Front and Rear Views for Server Module Front View A B D F C E G H G H I Legend A. B. C. D. E. F. G. H I. Drive Bays Pull-out Tab System Status LED BMC Reset Switch Dump (NMI) Switch VGA Connector UID Button/LED USB Connectors Power Button/LED Rear View A B C D E F G Legend A. B. C. D. PCI Slot (Low profile) Serial Port Connector UID LED / Button Power LED NEC Corporation E. F. G. Data LAN Connectors Management LAN Connector PCI Slot (flexible integrated NIC) Revision 5.0 – October 25, 2013 6 CONFIGURATION GUIDE – NEC Express5800/E120d-M Dimensions (mm) Server Module Enclosure Server Module (Left) Server Module (Right) NEC Corporation Revision 5.0 – October 25, 2013 7 CONFIGURATION GUIDE – NEC Express5800/E120d-M Configuration Diagram Server Module Enclosure Legend: Standard components Server Module (Left) Legend: Minimum requirement components Standard components Minimum requirement components Standard components Server Module (Right) Legend: NEC Corporation Revision 5.0 – October 25, 2013 8 CONFIGURATION GUIDE – NEC Express5800/E120d-M Expansion Slot #2 #1 Legend #1 PCIe 3.0 x16, x16 connector, Low-profile, up to 167.6 mm length #2 PCIe 3.0 x8, x8 connector, for a flexible integrated NIC NEC Corporation Revision 5.0 – October 25, 2013 9 CONFIGURATION GUIDE – NEC Express5800/E120d-M Server Configuration Maximum Server Module Configuration See the table below for the maximum server configuration based on processor configuration, input voltage, and maximum ambient temperature. The condition for the maximum server configuration is defined when four servers with the same configuration are installed. For another server configuration, please consult our sales representative. 200VAC Input Processor Type E5-2407 E5-2430 E5-2430L E5-2450L Max. Ambient Temp. # of Processors 2 1 2 2 40° C / 104° F 35°C / 95°F E5-2470 1 - # of 32 GB DIMMs # of 900 GB SAS drives No limitation No limitation No limitation Up to 7 DIMMs No limitation Up to 10 DIMMs No limitation No limitation No limitation No limitation No limitation No limitation Up to 1 HDDs No limitation Up to 3 HDDs No limitation # of 32 GB DIMMs # of 900 GB SAS drives Up to 10 DIMMs No limitation No limitation No limitation Up to 2 DIMMs Up to 5 DIMMs Up to 2 DIMMs Up to 8 DIMMs Up to 3 DIMMs No limitation No limitation No limitation Up to 3 HDDs No limitation No limitation Up to 2 HDDs Up to 1 HDDs Up to 4 HDDs Up to 1 HDDs Up to 1 HDDs No limitation No limitation 100VAC Input Processor Type # of Processors Max. Ambient Temp. E5-2407 2 40° C / 104° F E5-2430 E5-2430L 1 2 35°C / 95°F 40° C / 104° F 35°C / 95°F E5-2450L E5-2470 2 1 1 35°C / 95°F 40° C / 104° F - 1 Server Module Enclosure 1.1 Server Module Enclosure Product Name / Description Part Number Module Enclosure no server module Including: 2 x 1,000 Watt power supply, EXPRESSBUILDER DVD N8141-62F NOTE: Up to four server modules can be installed. NEC Corporation Revision 5.0 – October 25, 2013 10 CONFIGURATION GUIDE – NEC Express5800/E120d-M 1.2 Options for Server Module Enclosure 1.2.1 Blank Panel Product Name / Description Part Number Blank Panel 1pc of filler panel for server module slots N8141-61F NOTE: The blank panels must be installed into the vacant server module slots. 2 Server Module Product Name / Description Part Number NEC Express5800/E120d-M Server Module(Left) No processor, no RAM, no HDD NEC Express5800/E120d-M Server Module(Right) No processor, no RAM, no HDD N8100-1909F N8100-1908F NOTE: The base model must be ordered with a processor kit and a memory kit. The server module for left must be installed into slot #1 and #3, and that for right must be installed into slot #2 and #4. The server modules must be installed in an order from server module slot #1. #1 / Left #2 / Right #3 / Left #4 / Right 3 Processors and Heat Sink Available sockets: 2 Category Product Name / Description Part Number Processors 1 Processor Required Xeon E5-2407 Processor Kit Intel® Xeon ® Processor E5-2407 (2.20 GHz, 4C/4T, 10 MB) Xeon E5-2430 Processor Kit Intel® Xeon ® Processor E5-2430 (2.20 GHz, 6C/12T, 15 MB) Xeon E5-2430L Processor Kit Intel® Xeon ® Processor E5-2430L (2 GHz, 6C/12T, 15 MB) Xeon E5-2450L Processor Kit Intel® Xeon ® Processor E5-2450L (1.80 GHz, 8C/16T, 20 MB) Xeon E5-2470 Processor Kit Intel® Xeon ® Processor E5-2470 (2.30 GHz, 8C/16T, 20 MB) Processor Heat Sink st For 1 Processor N8101-601F Processor Heat Sink nd For 2 Processor N8101-609F Heat Sink 1st 2nd N8101-602F N8101-603F N8101-604F N8101-605F (Standard) NOTE: One processor kit from above must be installed. The processors must be the same to configure dual processor system. NEC Corporation Revision 5.0 – October 25, 2013 11 CONFIGURATION GUIDE – NEC Express5800/E120d-M 4 Memory Available slots: 6 per processor Category Product Name / Description Part Number Unbuffered DIMM (UDIMM) 2GB DDR3-1600 UNB Memory Kit 1x 2GB Unbuffered ECC DIMM, DDR3L-1600(PC3L-12800) 4GB DDR3-1600 UNB Memory Kit 1x 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3L-12800) N8102-504F 8GB DDR3-1600 REG Memory Kit 1x 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1600 REG Memory Kit 1x 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 32GB DDR3-1066 REG Memory Kit 1x 32GB Registered ECC DIMM, DDR3L-1066(PC3L-8500) N8102-506F Registered DIMM (RDIMM) N8102-505F N8102-507F N8102-508F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install three identical memory kits for dual-channel or triple-channel symmetric memory configurations to increase memory transfer speed. Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR3 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type E5-2403 E5-2407 E5-2430 E5-2430L E5-2450L E5-2470 NEC Corporation # of DIMMs per processor Memory Power Setting - - 1066 MHz RDIMM: 8 GB,16 GB Up to 3 DIMMs 4 or more DIMMs Up to 3 DIMMs 4 or more DIMMs - RDIMM: 32 GB - Low (1.35V) Normal (1.5V) - 800 MHz 1333 MHz 1066 MHz 1333 MHz 800 MHz 1333 MHz 1066 MHz 1333 MHz 1600 MHz 800 MHz Populated DIMMs UDIMM: 2 GB, 4 GB RDIMM: 8 GB,16 GB RDIMM: 32 GB UDIMM: 2 GB, 4GB RDIMM: 8 GB,16 GB RDIMM: 32 GB UDIMM: 2 GB, 4GB Revision 5.0 – October 25, 2013 DIMM Speed 12 CONFIGURATION GUIDE – NEC Express5800/E120d-M Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems Microsoft Windows Server 2008 Standard 4 GB Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 6 (x86_64) 1 VMware ESX 4.1 32 GB 4 GB (HW-DEP enabled) App. 2 GB (HW-DEP disabled) 32 GB 64 GB 2 TB 64 GB 384 GB 4 TB 384 GB 16 GB 16 GB 1 TB 2 TB 256 GB or 1 TB 2TB 4 TB 384 GB 384 GB 256 GB or 384 GB 384 GB 384 GB VMware ESXi 5.0, 5.1 2 VMware ESXi 5.5 1 2 Maximum Available Memory 2 Up to 255 GB of the main memory is available to each virtual machine. Up to 1TB of main memory is available to each virtual machine. NEC Corporation Revision 5.0 – October 25, 2013 13 CONFIGURATION GUIDE – NEC Express5800/E120d-M 5 Internal Hard Disk Drives 5.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration. Available Interface Available SATA Interface Non-RAID Refer to 5.2.1 RAID 0/1/10 RAID 0/1/10 Refer to 5.2.2 SAS, SATA SAS, SATA 512MB Cache Refer to 5.2.3 1GB Cache 1 GB Cache Refer to 5.2.4 SAS, SATA SAS, SATA SAS, SATA SAS, SATA RAID 5/6 NOTE: Hot plug insertion/removal are not supported in the Embedded SATA configuration. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives can be mixed in a drive cage. 5.2 Internal Drive Configuration 5.2.1 Embedded SATA Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb/s SATA, 2x 3Gb/s SATA Internal SATA Cable 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch Hot-plug hard drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Drive 4 slots available SATA HDD (Standard) (Standard) N8150-356 N8150-357 N8150-358 NOTE: Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. The maximum transfer speed for Slot 2 and Slot 3 is 3 Gb/s. NEC Corporation Revision 5.0 – October 25, 2013 14 CONFIGURATION GUIDE – NEC Express5800/E120d-M 5.2.2 RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID 0/1/10, 512 MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS/SATA Cable 1 x mini-SAS to 4 x Sinlge-SATA 2.5-inch Drive Cage 4 x 2.5-inch Hot-plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-149 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322 RAID BBU Recommended Cable Drive Cage Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8150-301 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives can be mixed in a Drive Cage. For VMware ESXi 5.5 installation, to download the CIM provider (LSI SMI-S provider) is required. NEC Corporation Revision 5.0 – October 25, 2013 15 CONFIGURATION GUIDE – NEC Express5800/E120d-M 5.2.3 RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512MB cache, Int.8, PCIe 2.0 x8 , SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS/SATA Cable 1 x mini-SAS to 4 x Single-SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-150 RAID BBU Recommended Cable Drive Cage Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives can be mixed in a Drive Cage. For VMware ESXi 5.5 installation, to download the CIM provider (LSI SMI-S provider) is required. NEC Corporation Revision 5.0 – October 25, 2013 16 CONFIGURATION GUIDE – NEC Express5800/E120d-M 5.2.4 RAID 5/6 Controller with 1 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS 9267-8i NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SAS/SATA Cable 1 x mini-SAS to 4 x Single-SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) RAID BBU Recommended SSD Caching Recommended Cable Drive Cage Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-153 N8103-156 (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives can be mixed in a Drive Cage. For VMware ESXi 5.5 installation, to download the CIM provider (LSI SMI-S provider) is required. NEC Corporation Revision 5.0 – October 25, 2013 17 CONFIGURATION GUIDE – NEC Express5800/E120d-M 6 Optical Drive Category Product Name / Description Part Number External External DVD-ROM drive DVD-ROM drive, Bus powered, 1.2 A required N8160-91 7 PCI Riser Card / PCI Card Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 7.1 Network Interface Controller Category Riser 1GbE 10GbE Adapter 1GbE 10GbE SPF+ Module NEC Corporation Product Name / Description Part Number Dual Port 1000BASE-T Riser Card Broadcom® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x8 Dual Port 10GBASE SFP+ Riser Card Broadcom® BCM57810 Converged Controller PCIe 3.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to two SFP+ Modules can be installed. N8104-141 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Intel® 82580 Gigabit Ethernet Controller PCIe 2.0 x4 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. - Jumbo frame is supported.on Redhat Enterprise Linux operating systems. N8104-138 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. Dual Port 10Gb Converged Network Adapter BROCADE 1020 Dual Port 10Gbps Converged Network Adapter PCIe 2.0 x8, 2 x SFP modules, Max. one adapter SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128 and N8104-137 N8104-128 Revision 5.0 – October 25, 2013 N8104-142 N8104-132 N8104-145 N8104-133 N8104-131 N8104-129 18 CONFIGURATION GUIDE – NEC Express5800/E120d-M NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2003 R2 and Windows Server 2008 support BASP (Broadcom Advanced Server Program) teaming while Windows Server 2012 and Linux supports teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded 1GbE NIC and N8104-138/-132/-133/-141 Up to four teams per one system Up to four ports per one team 10GbE NIC N8104-128 Up to two teams per one system Up to two ports per one team Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 NOTE: NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for NIC teaming must be the same. When 10GbE and 1GbE NIC teaming are mixed, the teams must be up to four per one system. Using iSCSI See the table below for supported network interfaces and OS combinations. Categor Network Interface Operating Systems 1GbE Embedded 1GbE NIC N8104-138 N8104-132 N8104-133 N8104-141 N8104-128 Windows Server 2008 R2, Windows Server 2012, VMware Windows Server 2008 R2, Windows Server 2012, VMware Windows Server 2008 R2, Windows Server 2012, VMware Windows Server 2008 R2, Windows Server 2012, VMware Windows Server 2008 R2, Windows Server 2012, VMware Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, VMware y 10GbE NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 7.2 InfiniBand Category Product Name / Description Part Number Controller Single Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX353A-FCBT, FDR, PCIe 3.0(x8) Dual Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX354A-FCBT, FDR, PCIe 3.0(x8) InfiniBand Cable 2m/FRD Copper InfiniBand Cable 3m/FDR Copper InfiniBand Switch 36 ports/FDR Mellanox MSX6036F-1SFR 36 ports, FDR, One power supply module included, no power cord Redundant Power Supply Unit Power supply module for 36 ports InfiniBand switch, no power cord N8104-146 Cable Switch Unit Power Supply NEC Corporation Revision 5.0 – October 25, 2013 N8104-147 K410-304(02) K410-304(03) NE3707-061 NE3707-063 19 CONFIGURATION GUIDE – NEC Express5800/E120d-M NOTE: The InfiniBand adapters and other options are make-to-order products. Please consult our sales representative in regards to production lead time. 7.3 External Storage Controller 7.3.1 RAID Controller Category Product Name / Description Part Number Controller RAID Controller (512MB, RAID0/1/5/6) LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9285-8e N8103-160 RAID BBU N8103-162 NOTE: To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. 7.3.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 N8190-153 SAS N8190-154 N8190-157 N8190-158 N8103-142 8 Other Add-in Components 8.1 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NOTE: Up to one drive can be connected. NEC Corporation Revision 5.0 – October 25, 2013 20 CONFIGURATION GUIDE – NEC Express5800/E120d-M 9 Add-on Components 9.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad 9.2 Product Name / Description Part Number 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 N8191-12F Cable KVM Cascading NEC Corporation Revision 5.0 – October 25, 2013 K410-118(1A) K410-118(03) K410-118(05) K410-119(1A) 21 CONFIGURATION GUIDE – NEC Express5800/E120d-M 9.3 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-04 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 5.0 – October 25, 2013 22 CONFIGURATION GUIDE – NEC Express5800/E120d-M References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware configuration information collection Hardware event log collection Boot monitoring Alerting Remote KVM (via LAN) Remote control (via LAN) Maintenance Others Industry standard 1 2 3 BIOS/POST stall, Booting, OS stall, shutdown HW error, Boot error , and OS panic (by SNMP, E-Mail) POST/BIOS setup, ROM utility Panic screen, Boot screen CUI-based screen (OS console) GUI-based screen (OS console) Remote reset/power on-off/ dump Remote power capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) OS shutdown Remote media (CD/DVD/FD/USB key) CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS) EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection IPMI With Remote KVM and Media License kit 2 2 1, 3 1 2 2 2 2 2.0 2.0 In VMware systems, only the direct console user interface is supported. The feature is not supported on VMware ESX systems. Monitoring boot screens is not supported on VMware systems. NEC Corporation Revision 5.0 – October 25, 2013 23 CONFIGURATION GUIDE – NEC Express5800/E120d-M OS Support Matrix for PCI Cards and Embedded Controller ESXi 5.5 ESXi 5.1 ESXi 5.0 ESX 4.1 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2008 x64 WS 2008 WS 2008R2 WS 2012 Part number Product Name - Embedded SATA non-RAID Controller - Embedded 1GbE NIC N8103-149 RAID controller (512MB, RAID 0/1) N8103-150 RAID controller (512MB, RAID 0/1/5/6) N8103-151 N8103-160 RAID controller (1GB, RAID 0/1/5/6) RAID Controller (1 GB,RAID 0/1/5/6) N8103-142 SAS controller N8190-153 Fibre Channel Controller (1ch) N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller (1ch) N8190-158 Fibre Channel Controller (2ch) N8104-138 1000BASE-T adapter N8104-132 Dual Port 1000BASE-T Adapter N8104-133 Quad Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter N8104-128 10GBASE adapter (SFP+/2ch) N8104-131 Dual Port 10Gb Converged Network Adapter N8104-141 Dual Port 1000BASE-T Riser Card N8104-142 Dual Port 10GBASE SFP+ Riser Card N8104-146 Single Port InfiniBand Adapter N8104-147 Dual Port InfiniBand Adapter NEC Corporation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Revision 5.0 – October 25, 2013 24 CONFIGURATION GUIDE – NEC Express5800/E120d-M Supported PCI Cards and Installable Slots Slots Part Number Product Name #1 #2 - Dual Port 10Gb Converged Network Adapter N8104-141 Dual Port 1000BASE-T Riser Card - N8104-142 N8104-146 Dual Port 10GBASE SFP+ Riser Card - Single Port InfiniBand Adapter N8104-147 Dual Port InfiniBand Adapter N8103-149 RAID controller (512MB, RAID 0/1) N8103-150 RAID controller (512MB, RAID 0/1/5/6) N8103-151 RAID controller (1GB, RAID 0/1/5/6) N8103-160 N8103-142 RAID Controller (1 GB,RAID 0/1/5/6) SAS controller N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller (1ch) N8190-158 Fibre Channel Controller (2ch) N8104-138 1000BASE-T adapter N8104-132 Dual Port 1000BASE-T adapter N8104-133 Quad Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter N8104-128 10GBASE adapter (SFP+/2ch) N8104-131 NEC Corporation Revision 5.0 – October 25, 2013 - - 25 CONFIGURATION GUIDE – NEC Express5800/E120d-M Tested Linux Operating Systems Operating Systems Red Hat Enterprise Linux 5.8 (x86) Red Hat Enterprise Linux 5.8 (x86_64) Red Hat Enterprise Linux 6.2 (x86) Red Hat Enterprise Linux 6.2 (x86_64) Red Hat Enterprise Linux 6.3 (x86) Red Hat Enterprise Linux 6.3 (x86_64) Red Hat Enterprise Linux 6.4 (x86) Red Hat Enterprise Linux 6.4 (x86_64) CentOS 5.8 (x86) CentOS 5.8 (x86_64) CentOS 6.2 (x86) CentOS 6.2 (x86_64) CentOS 6.3 (x86) CentOS 6.3 (x86_64) Scientific Linux 6.2 (x86_64) Scientific Linux 6.3 (x86) Scientific Linux 6.3 (x86) Scientific Linux 6.3 (x86_64) Vine Linux 6.1(x86) Vine Linux 6.1(x86_64) Debian GNU/Linux 6.0 (i386) Debian GNU/Linux 6.0 (amd64) 1 FreeBSD 8.2 (i386) 1 FreeBSD 8.2 (amd64) 1 Ubuntu 10.04 LTS (i386) 2 Ubuntu 10.04 LTS (amd64) 1 Ubuntu 12.04 LTS (i386) 2 Ubuntu 12.04 LTS (amd64) 1 2 Supports only embedded SATA controller for internal storage controller USB-HUB is required when internal HDDs are connected to N8103-149/150/151 RAID controller, since additional USB port is required for installation. NOTE: For the latest information, go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 5.0 – October 25, 2013 26 CONFIGURATION GUIDE – NEC Express5800/E120d-M Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 5.0 – October 25, 2013 27 CONFIGURATION GUIDE – NEC Express5800/E120d-M Revision History Revision Date Description 5.0 October 25, 2013 4.0 July 17, 2013 3.0 April 16, 2013 2.2 March 29, 2013 2.1 December 26, 2012 2.0 October 31, 2012 1.0 September 13, 2012 New products added: Single Port InfiniBand Adapter / N8104-146 Dual Port InfiniBand Adapter / N8104-147 InfiniBand Cable 2m/FRD / K410-304(02) InfiniBand Cable 3m/FRD / K410-304(03) InfiniBand Switch 36 ports/FDR / NE3707-061 Redundant Power Supply Unit / NE3707-063 Others: Add VMware ESXi 5.5 to the list of operating system supported Update OS support matrix New products added: 1.2TB 10K Hot Plug 2.5-inch SAS HDD / N8150-408 Dual Port 1000BASE-T Adapter / N8104-145 New products added: Fibre Channel Controller (1ch) / N8190-157 Fibre Channel Controller (2ch) / N8190-158 Part number changed: External DVD-ROM Drive / N8160-91 Discontinued products removed: 100GB SSD / N8150-709 400GB SSD / N8150-710 Others: Added support for NIC teaming on Windows Server 2012 systems. N8103-142 SAS Controller is supported on Windows Server 2012 systems Updated the Tested Linux Operating Systems table Other: Added Windows Server 2012 to the list of supported operating systems Updated OS support matrix Other: Added the description of NIC Teaming feature and Using iSCSI Added Windows Server 2008 and 2008 R2 to the list of operating system supported Updated OS support matrix Updated the Tested Linux Operating Systems New products added: 200GB SSD / N8150-711 400GB SSD / N8150-712 Other: Added VMware ESXi 5.1 to the list of operating system supported Updated OS support matrix Initial release NEC Corporation Revision 5.0 – October 25, 2013 28