Specs

SPECIFICATION SHEET
JFW MODEL 50MS-303
3 X 3 BLOCKING ELECTRO-MECHANICAL MATRIX SWITCH
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
Frequency Range
DC-6000 MHz
Configuration
3 x 3 Blocking Matrix
(see block diagram 092-7400)
(maximum of 3 active RF paths)
(unused input ports are reflective)
(unused output ports are reflective)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Startup/Default States
(configurable)
All ports off at startup (see MATRIX command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Enclosure Type
19 inch rack mount @ 3RU high
Impedance
50 Ohms nominal
VSWR
1.3:1 typical
1.5:1 maximum
Insertion Loss
1.0 dB maximum DC-2500MHz
2.0 dB maximum 2500-6000MHz
Isolation
Out to Out /In to Out / In to In
70 dB minimum DC-4000MHz
65 dB minimum 4000-6000MHz
RF Input Power
1 Watt average (Hot Switched)
90 Watts (Cold Switched)
Switching Speed
20 milliseconds
(after command is received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Control (Remote)
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
SPECIFICATION SHEET
JFW MODEL 50MS-303
3 X 3 BLOCKING ELECTRO-MECHANICAL MATRIX SWITCH
Remote Command Format
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
Matrix Commands:
Matrix, Set Input, Set Output, Read Input, Read
Output, Read All Inputs, Read All Outputs, Read Matrix
Paths
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
N female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Temperature Ranges
Operating: 0ºC to +70ºC
Storage: -20ºC to +85ºC
Physical Size
See outline drawing 092-7377
ECR/ECN #
DATE
REV
07/02/2012
24239
Page 2 of 2
07/15/2015
APPR / DATE
ECR/ECN #
BAC 07/02/2012
A
TRS 07/15/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE