Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50SA-282
SWITCH ASSEMBLY
Frequency Range
DC-18 GHz
Configuration
4 individually controlled 1P2T failsafe selfterminating electro-mechanical RF switches
(J1 is failsafe port)
Enclosure Type
19 inch rack mount @ 2RU high
Startup/Default States
(configurable)
RF switches to port J1 at startup (see SWITCH command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
Impedance
50 Ohms nominal
VSWR
1.2:1
1.3:1
1.4:1
1.5:1
Insertion Loss
0.2
0.3
0.4
0.5
Isolation
70
65
60
60
RF Input Power
(cold switched)
100 Watts average DC-4 GHz
90 Watts average 4-8 GHz
70 Watts average 8-12.4 GHz
60 Watts average 12.4-18 GHz
(*Internal Terminations rated at 2 Watts average)
Switching Speed
15 milliseconds
(after command is received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
maximum
maximum
maximum
maximum
dB
dB
dB
dB
dB
dB
dB
dB
maximum
maximum
maximum
maximum
minimum
minimum
minimum
minimum
DC-4 GHz
4-8 GHz
8-12.4 GHz
12.4-18 GHz
DC-4 GHz
4-8 GHz
8-12.4 GHz
12.4-18 GHz
DC-4 GHz
4-8 GHz
8-12.4 GHz
12.4-18 GHz
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50SA-282
SWITCH ASSEMBLY
Remote Commands
RF Switch Control Commands:
Switch, Set Switch, Read Switch, Set All Switches,
Read All Switches
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
RF Connector
SMA female
Operating Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-6794
ECR/ECN #
DATE
REV
11/22/2010
Page 2 of 2
APPR / DATE
ECR/ECN #
BAC 11/22/2010
23179
08/23/2013
A
TRS 08/23/2013
24239
12/08/2014
B
TRS 12/08/2014
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE