JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75SA-095 SWITCH ASSEMBLY Frequency Range DC-2150 MHz Configuration 8 individually controlled 1P2T failsafe selfterminating electro-mechanical RF switches (port 1 is failsafe position) Enclosure Type Benchtop Startup/Default States (configurable) RF switches to port J1 at startup (see SWITCH command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) All of these default settings can be changed by user. Unit can be configured for up to 12 Ethernet users. Impedance 75 Ohms nominal VSWR 1.6:1 maximum 1.4:1 typical Insertion Loss 1.3 dB maximum 0.8 dB typical @ 2150 MHz Isolation 50 45 70 60 RF Input Power +20 dBm Switching Speed 10 milliseconds typical (after command is received and processed) (3 milliseconds typical processing time) Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) dB dB dB dB minimum DC-1000 MHz minimum 1000-2150 MHz typical @ 1000 MHz typical @ 2150 MHz --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75SA-095 SWITCH ASSEMBLY Remote Commands RF Switch Control Commands: Switch, Set Switch, Read Switch, Set All Switches, Read All Switches System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector BNC, F or TNC female AC Supply 100-240 VAC @ 47-63 Hz Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-8385 ECR/ECN # DATE 08/13/2015 Page 2 of 2 REV APPR / DATE ECR/ECN # TRS 08/13/2015 JFW FORM E-7-F REV F DATE REV APPR / DATE