Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-673
HANDOVER TEST SYSTEM
Frequency Range
700-3000 MHz
Configuration
12 x 4 Handover Test System
(see block diagram 092-5634 for attenuator addressing)
(all ports are bi-directional)
(full fan-out i.e. every path has its own attenuator)
(the ADMIN password is located on rear panel)
Enclosure Type
19 inch rack mount @ 8RU high
Impedance
50 Ohms nominal
Attenuation Range
0-127 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command)
Prompts off (see PROMPT command)
VSWR
1.5:1 typical
1.7:1 maximum
Insertion Loss
29.7 dB typical @ 700 MHz
34.2 dB typical @ 3000 MHz
Attenuation Accuracy
± 0.5 dB or 2% typical
± 0.75 dB or 2% maximum
(whichever is greater)
(guaranteed monotonic)
Power Divider Isolation
20 dB minimum
RF Input Power
1 Watt average
Switching Speed
10 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
4 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-004, JFW #025-018
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-673
HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Path, Read Path, Read All Paths, Set
Attenuator, Read Attenuator, Set All Attenuators, Read
All Attenuators, Read All Extended, Fade Attenuator,
Variable Attenuator Handover, Block, Set Block, Read
Block, Read All Blocks, Fade Block, Variable Block
Handover
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
N or SMA female
Temperature Range
0ºC to +50ºC
Physical Size
See outline drawings 092-5635 (50PA-673 SMA)
092-7620 (50PA-673 N)
ECR/ECN #
DATE
REV
07/19/2011
Page 2 of 2
APPR / DATE
ECR/ECN #
TRS 07/19/2011
22526
02/19/2013
A
TRS 02/19/2013
24239
09/09/2014
B
TRS 09/09/2014
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE