Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-983
HANDOVER TEST SYSTEM
Frequency Range
500-6000 MHz
Configuration
8 x 8 Handover System
(see block diagram 092-6869 for attenuator addressing)
(all ports are bi-directional)
(full fan-out configuration)
(the ADMIN password is located on rear panel)
Enclosure Type
19 inch rack mount @ 12RU high
Impedance
50 Ohms nominal
Attenuation Range
0-95 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
VSWR
1.7:1 maximum
< 1.5:1 typical
Insertion Loss
41 dB maximum
31 dB typical @ 500 MHz
40 dB typical @ 6000 MHz
Attenuation Accuracy
± 0.50 dB
1-3 dB
± 0.75 dB
4-7 dB
± 1.00 dB
8-11 dB
± 1.25 dB or 4%
12-95 dB
(whichever is greater)
(guaranteed monotonic)
Isolation
50 dB minimum (Input to Input)
50 dB minimum (Output to Output)
RF Input Power
+30 dBm average
Switching Speed
1 microsecond typical
(after command received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-983
HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Path, Read Path, Read All Paths, Set
Attenuator, Read Attenuator, Set All Attenuators, Read
All Attenuators, Read All Extended, Fade Attenuator,
Variable Attenuator Handover
MIMO Testing Commands:
Block, Set Block, Read Block, Read All Blocks, Fade
Block, Variable Block Handover
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
SMA female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-8481
ECR/ECN #
DATE
REV
11/18/2015
26507
Page 2 of 2
04/04/2016
APPR / DATE
ECR/ECN #
CLK 11/18/2015
A
TRS 04/04/2016
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE