MA1000RU - Micropower Direct

MA1000RU Series
Compact, 10W DIP
Ultra Wide 4:1 Input
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 10W Output Power
• Compact DIP Case
• Ultra Wide 4:1 Input
• Single & Dual Outputs
• High Efficiency
• 1,500 VDC Isolation
• >1.0 MHour MTBF
• 16 Standard Models
• Industry Standard Pin-Out
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Conditions
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
Short Circuit Input Power
Internal Power Dissipation
Input Filter
Min.
Typ.
Max.
9.0
18.0
8.5
17.5
3,000
2,500
Units
Max.
±2.0
±2.0
±1.0
±1.2
100
600
±5.0
±0.02
Units
%
%
%
%
mV P - P
µSec
%
%/°C
%
Typ.
Max.
1,000
1,500
Units
VDC
M
pF
kHz
VDC
VDC
mW
mW
(Pi) Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
Conditions
Min.
Dual Output, Balanced Loads
VIN = Min to Max
IOUT = 0% to 100%
See Note 1
Typ.
±1.0
±1.0
±0.5
±0.5
300
±3.0
±0.01
Foldback
110
150
Continuous (Autorecovery)
25% Load Step Change
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Min.
1,500
1,000
330
Standard
See Note 3
See Note 3
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling, See Note 4
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+100
+125
Units
°C
°C
°C
95
%
See Mechanical Drawing (Page 2)
Metal With Non-Conductive Base (UL94-V0)
0.61 Oz (17.3g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MA1024S-03RU
MA1024S-05RU
MA1024S-12RU
MA1024S-15RU
MA1024S-24RU
MA1024D-12RU
MA1024D-15RU
MA1048S-03RU
MA1048S-05RU
MA1048S-12RU
MA1048S-15RU
MA1048S-24RU
MA1048D-12RU
MA1048D-15RU
Output
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
24
9.0 - 36.0
432
30
24
9.0 - 36.0
490
30
24
9.0 - 36.0
479
30
24
9.0 - 36.0
478
30
24
9.0 - 36.0
478
30
24
9.0 - 36.0
478
30
24
9.0 - 36.0
478
30
48
18.0 - 75.0
216
20
48
18.0 - 75.0
245
20
48
18.0 - 75.0
239
20
48
18.0 - 75.0
236
20
48
18.0 - 75.0
244
20
48
18.0 - 75.0
244
20
48
18.0 - 75.0
244
20
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be placed from
the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. An external 220 µF/100V capacitor connected across the input pins is required to meet
EN61000-4-4 and EN61000-4-5.
4. Free air convection is typically 20 LFM. The units should not be operated in still air (0 LFM).
5. Operation at no-load will not damage these units.
6. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the load across
the positive (+VOUT) and negative (-VOUT) outputs and float the output common.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for
the correct rating.
2,700
2,000
833
666
416
±416
±333
2,700
2,000
833
666
416
±416
±333
Efficiency
(%, Typ)
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
86
85
87
87
87
87
87
86
85
87
87
87
87
87
40.0
40.0
40.0
40.0
40.0
40.0
40.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
(mA)
1,000
1,000
470
330
150
±220
±150
1,000
1,000
470
330
150
±220
±150
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
Derating Curve
Remote On/Off
Parameter
Min
Supply On
Supply Off
Standby Input Current
Control Common
Control Input Current (ON)
Control Input Current (OFF)
3.5
0.0
Typ
Max
Units
12.0
VDC
1.2
VDC
10
mA
Referenced to Negative Input (pin 2)
0.5
mA
-0.5
mA
Applying a signal to pin 1 will turn the unit ON/OFF. If the pin is left open, the unit
operates. If grounded, the unit will shut off. The specifications for the ON/OFF function
are given in the table above.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
2
3
9
11
14
16
22
23
Remote ON/OFF
-VIN
-VIN
No Pin
NC
+VOUT
-VOUT
+VIN
+VIN
Remote ON/OFF
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
NC: No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.x = ±0.02 (±0.50)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]