Specs

SPECIFICATION SHEET
JFW MODEL 50MS-288
8 X 8 NON-BLOCKING SOLID STATE MATRIX SWITCH
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
Frequency Range
20-1000 MHz
Configuration
8 x 8 Non-Blocking Matrix
(See block diagram 092-2886)
(Unused input ports are self-terminating)
(Unused output ports are self-terminating)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Startup/Default States
(configurable)
All ports off at startup (see MATRIX command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Enclosure Type
19 inch rack mount @ 5RU high
Impedance
50 Ohms nominal
VSWR
1.4:1 typical / 1.6:1 maximum
Insertion Loss
13dB typical @ 20MHz
14dB typical @ 1000MHz
15dB maximum 20-1000MHz
Isolation
Output to Output
(Set to same input)
Output to Output
(Set to diff inputs)
- 30 dB typical
- 20 dB minimum
- 90 dB typical
- 70 dB minimum
Input to Output
- 90 dB typical
- 70 dB minimum
Input to Input
- 90 dB typical
- 70 dB minimum
RF Input Power
+20 dBm average
+27 dBm (no damage)
Switching Speed
20 microseconds
(after command is received and processed)
(3 milliseconds typical processing time)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-288
8 X 8 NON-BLOCKING SOLID STATE MATRIX SWITCH
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
Remote Commands
Matrix Commands:
Matrix, Set Input, Set Output, Read Input, Read
Output, Read All Inputs, Read All Outputs, Read Matrix
Paths
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
N female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Temperature Ranges
Operating: 0ºC to +70ºC
Storage: -55ºC to +85ºC
Physical Size
See outline drawing 092-7159
ECR/ECN #
DATE
REV
12/02/2011
24239
Page 2 of 2
07/15/2015
APPR / DATE
ECR/ECN #
BAC 12/02/2011
A
TRS 07/15/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE