JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50SA-374 SWITCH ASSEMBLY Frequency Range DC-12.4 GHz Configuration 16 individually controlled 1P2T failsafe reflective electro-mechanical RF switches (J1 is failsafe port) Enclosure Type 19 inch rack mount @ 5RU high Startup/Default States (configurable) RF switches to port J1 at startup (see SWITCH command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) Impedance 50 Ohms nominal VSWR 1.15:1 1.25:1 1.35:1 1.50:1 Insertion Loss 0.15 0.25 0.35 0.50 Isolation 85 70 65 60 RF Input Power (Hot Switched) 1 Watt average RF Input Power (Cold Switched) 350 150 120 100 Switching Speed 20 milliseconds (after command is received and processed) (3 milliseconds typical processing time) Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) maximum maximum maximum maximum dB dB dB dB dB dB dB dB DC-1GHz 1-4GHz 4-8GHz 8-12.4GHz maximum maximum maximum maximum minimum minimum minimum minimum Watts Watts Watts Watts DC-1GHz 1-4GHz 4-8GHz 8-12.4GHz DC-1GHz 1-4GHz 4-8GHz 8-12.4GHz average average average average --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F DC-1GHz 1-4GHz 4-8GHz 8-12.4GHz JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50SA-374 SWITCH ASSEMBLY Remote Commands RF Switch Control Commands: Switch, Set Switch, Read Switch, Set All Switches, Read All Switches System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt Lifetime (each switch) 1 million operations minimum AC Supply 100-240 VAC @ 47-63 Hz 2 Amp 5x20mm "Slo-Blo" AC fuse Littelfuse #215-002, JFW #025-021 RF Connector N female Operating Temperature Range 0º to +70º C Physical Size See outline drawing 092-7449 ECR/ECN # DATE REV 09/13/2012 24236 Page 2 of 2 12/08/2014 APPR / DATE ECR/ECN # BAC 09/13/2012 A TRS 12/08/2014 JFW FORM E-7-F REV F DATE REV APPR / DATE