JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-730 HANDOVER TEST SYSTEM Frequency Range 700-3000 MHz Configuration 6 x 3 Handover Test System (see block diagram 092-7414 for attenuator addressing) (all ports are bi-directional) (full fan-out i.e. every path has its own attenuator) (the ADMIN password is located on rear panel) Enclosure Type 19 inch rack mount @ 5RU high Impedance 50 Ohms nominal Attenuation Range 0-127 dB in 1 dB steps Startup/Default States (configurable) Maximum attenuation (see ATTEN STARTUP command) DHCP enabled (see NET command) 4 Ethernet users (see NET USERS command) Prompts off (see PROMPT command) VSWR 1.7:1 maximum 1.6:1 typical Insertion Loss 28.4 dB maximum 26.4 dB typical Attenuation Accuracy ± 0.75 dB or 2% maximum ± 0.50 dB or 2% typical (whichever is greater) (guaranteed monotonic) Power Divider Isolation 23 dB minimum RF Input Power +20 dBm average +30 dBm no damage Switching Speed 5 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) AC Supply 100-240 VAC @ 47-63 Hz 2 Amp 5x20mm "Slo-Blo" AC fuse Littelfuse #215-002, JFW #025-021 Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-730 HANDOVER TEST SYSTEM Remote Commands Attenuator Control Commands: Atten, Set Path, Read Path, Read All Paths, Set Attenuator, Read Attenuator, Set All Attenuators, Read All Attenuators, Read All Extended, Fade Attenuator, Variable Attenuator Handover, Block, Set Block, Read Block, Read All Blocks, Fade Block, Variable Block Handover System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector N female Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-7413 ECR/ECN # DATE REV 07/20/2012 Page 2 of 2 APPR / DATE ECR/ECN # TRS 07/20/2012 23742 02/11/2014 A TRS 02/11/2014 24239 09/09/2014 B TRS 09/09/2014 JFW FORM E-7-F REV F DATE REV APPR / DATE