Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-313
4x4 NON-BLOCKING SOLID STATE MATRIX SWITCH
Frequency Range
700-3000 MHz
Configuration
4 x 4 Non-Blocking Solid-State Matrix
(see block diagram 092-7494)
(Unused input ports are self-terminating)
(Unused output ports are self-terminating)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Startup/Default States
(configurable)
All ports off at startup (see MATRIX command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Enclosure Type
19 inch rack mount @ 3RU high
Impedance
50 Ohms nominal
VSWR
1.5:1 typical / 1.7:1 maximum
Insertion Loss
10 dB nominal @ 700MHz
12 dB nominal @ 3000MHz
Isolation
Output to Output
(Set to Diff INs)
- 80 dB typical
- 60 dB minimum
Output to Output
(Set to Same IN)
- 28 dB typical
- 20 dB minimum
Input to Output
(Path OFF)
- 80 dB typical
- 60 dB minimum
Input to Input
- 80 dB typical
- 60 dB minimum
RF Input Power
+30 dBm maximum
Switching Speed
10 microseconds
(after command is received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-313
4x4 NON-BLOCKING SOLID STATE MATRIX SWITCH
Remote Commands
Matrix Commands:
Matrix, Set Input, Set Output, Read Input, Read
Output, Read All Inputs, Read All Outputs, Read Matrix
Paths
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date,
Message,Restrict, IDENT, Name, Show Users, Reboot,
Uptime, Prompt
RF Connector
N female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Temperature Ranges
Operating: 0ºC to +70ºC
Storage: -55ºC to +85ºC
Physical Size
See outline drawing 092-6835
ECR/ECN #
DATE
REV
10/23/2012
24239
Page 2 of 2
04/28/2015
APPR / DATE
ECR/ECN #
BAC 10/23/2012
A
BAC 04/28/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE