Specs - JFW Industries

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-792
LC HANDOVER TEST SYSTEM
Frequency Range
700-3000 MHz
Configuration
Dual 8 X 1 LC Handover Test System
(see block diagram 092-7666 for attenuator addressing)
(all ports are bi-directional)
(limited fan-out configuration)
(the ADMIN password is located on rear panel)
Enclosure Type
19 inch rack mount @ 3RU high
Impedance
50 Ohms nominal
Attenuation Range
0-127 dB in 1 dB steps
VSWR
1.7:1 maximum
< 1.6:1 typical
Attenuation Accuracy
± 0.7 dB or 2% maximum
± 0.5 dB or 2% typical
(guaranteed monotonic)
Insertion Loss
21 dB maximum
20 dB typical
Isolation
Between Attenuator Ports 1-8:
27 dB minimum
Between Attenuator Ports 9-16:
27 dB minimum
RF Input Power
+20 dBm average (into Attenuator ports)
+30 dBm average (into J1/J2 ports)
Switching Speed
5 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-792
LC HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Attenuator, Read Attenuator, Set All
Attenuators, Read All Attenuators, Read All Extended,
Fade Attenuator, Variable Attenuator Handover, Block,
Set Block, Read Block, Read All Blocks, Fade Block,
Variable Block Handover
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
SMA or N female
Operating Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-7665
ECR/ECN #
DATE
REV
04/02/2013
24239
Page 2 of 2
09/08/2014
APPR / DATE
ECR/ECN #
TRS 04/02/2013
A
TRS 09/08/2014
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE