M Series Disk Array Model in August, 2015 Main Software for NEC Storage M Series Category Storage management M310 M510 M710 NEC Storage Manager *1 *1 *1 Basic functions to enable integrated storage operations management NEC Storage Manager Integration Base *1 *1 *1 Functions to achieve integrated storage operations by in collaboration with SigmaSystemCenter Software Product Name Device management Performance management M110 Description NEC Storage Manager Suite Package product including both NEC Storage Manager and NEC Storage Manager Integration Base NEC Storage PerformanceMonitor Functions to monitor storage performance in real-time and accumulate monitoring data NEC Storage PerformanceNavigator Functions to streamline the analysis of storage performance data NEC Storage PerformanceMonitor Suite Package product including both NEC Storage PerformanceMonitor and NEC Storage PerformanceNavigator Replication management NEC Storage ReplicationNavigator Suite NEC Storage BaseProduct Storage control NEC Storage Manager Express NEC Storage ControlCommand * NEC Storage DynamicDataReplication ** Functions to create a fully replicated volume in the same storage unit NEC Storage RemoteDataReplication * Functions to create a fully replicated volume in a remote storage unit NEC Storage RemoteDataReplication Asynchronous *3 Functions to asynchronously create a fully replicated volume in a remote store unit by using a low-speed line Replication Disaster recovery Basic functions to control storage * 1 * 1 * 1 3 Function to back-up/restore volumes in M series to/from HS series without intervening backup server *3*5 *5 *5 *5 Option to enable non-disruptive backup of Microsoft SQL Server NEC Storage ReplicationControl FileSystem Option NEC Storage RemoteDataReplication/DisasterRecovery Option to enable non-disruptive backup of file systems Functions to perform the remote replication essential for a disaster prevention and response system Functions to divide storage resources and manage the divided storage resources as virtual storage NEC Storage ThinProvisioning *2 *1 *1 *1 NEC Storage StoragePowerConserver *2 *1 *1 *1 * * * * NEC Storage DataMigration NEC Storage VolumeProtect Functions to use a SSD as cache memory 2 1 1 1 Functions to migrate data from an existing storage unit to a new one Functions to protect data from tampering and guarantee data integrity for each volume NEC Storage IO Load Manager NEC Storage PathManager Functions to enhance the capacity usage efficiency by setting the virtual logical capacity and reducing the physical capacity to be allocated Functions to reduce the power consumption of a storage unit by controlling the running and stopping of a HDD Functions to optimize performance by distributing the volume load and changing physical volume allocations without stopping jobs NEC Storage PerforOptimizer NEC Storage PerforCache High availability Functions to create a differential replicated volume NEC Storage ReplicationControl SQL Option NEC Storage VirtualCachePartitioning Resource control Basic functions to enable storage operations management CLI functions to perform operations such as replication and data protection on an application server 3 4 NEC Storage DirectDataShadow Option NEC Storage DynamicSnapVolume Storage control Functions to easily create a backup system of databases, file servers, and virtual machines 2 Function to control of I/O from the application server to the storage device by setting an upper or lower limit for IOPS of each logical disk * 2 Functions to automatically switch paths and distribute the I/O loads *1: Bundled with NEC Storage BaseProduct. *2: Bundled with M110. *3: Not supported by a single controller model. *4: NEC Storage DynamicDataReplication Express is bundled with M110. *5: Bundled with NEC Storage DynamicDataReplication. Environmental compliance M110 M310 M510 M710 RoHS Compliance This product complies with the European Union directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS). Eco Symbol The Eco Symbol is a label placed on products that meet NEC prescribed environmental soundness standards. Eco Symbol products must be environmentally superior and assure transparency. Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries. Linux is a trademark or registered trademark of Linus Torvalds in the United States and other countries. Red Hat is a trademark or registered trademark of Red Hat, Inc in the United States and other countries. VMware is a trademark or registered trademark of VMware, Inc. in the United States and other countries. All other products, brands, and trade names used in this document are trademarks or registered trademarks of their respective holders. Safety notice Before you use this product, please read carefully and comply with the cautions and warnings in manuals such as User’s Guide and Installation Guide. Incorrect use may cause a fire, electrical shock or injury. For further information, please contact: Specifications and designs in this catalog are subject to change for improvement without notice. NEC Corporation As of August 2015 Cat.No.E11-15080009E SAN Storage Product Family M Series Disk Array NEC Storage M Series, the new SAN storage infrastructure. Awakening the true potential of storage units in IT environments of the future. M Series Disk Array Responding to ballooning data, preparing for virtualization and cloud environments, and power-saving needs. The drastically changing environment of IT infrastructure requires a storage unit that meets these needs. M Series has been developed to satisfy these needs by bringing together the high reliability technology and innovative ability that NEC has acquired during the development of the NEC Storage products. The new SAN storage infrastructure leads the ever-evolving virtualization and cloud computing age. M Series has superior characteristics for next-generation SAN storage units. These features address the need for high performance and high availability to support business continuity, advanced eco-friendly performance, easy installation Demands on Storage Units and operations that reduce the management workload, and economic efficiency that reduces the TCO to store and archive data. M Series offers a diverse product lineup consisting of entry model M110 Disk Array, basic model M310 Reduce the workload required for storage management by using Reduce the cost of storing ever-increasing data at businesses virtualization technology Improve the operating efficiency by integrating a server virtualization Disk Array, and high performance model M510 Disk Array and M710 Disk Array that achieves a large-scale storage Efficiently manage data according to its usage frequency environment integration by utilizing advanced virtualization technologies such as data allocation optimization with a high-speed Dramatically reduce the power consumption of storage units for Construct a disaster response site to prepare for earthquakes and fires environmental conservation and power saving Improve problematic backup systems solid state drive (SSD) and thin provisioning, all developed to respond to the needs of the next generation. Ensure the continuous operations in the face of unforeseen failures Entry model Basic model High Performance model High Performance & High Availability Advanced Eco-friendly Function M Series IT Cost Optimization M110 Easy Installation & Operation Max. 8 ports (FC/iSCSI/SAS) Max. 120 HDDs M310 Max. 8 ports (FC/iSCSI) Max. 480 HDDs High Performance & High Availability M510 Max. 32 ports (FC/iSCSI) Max. 768 HDDs M710 Max. 48 ports (FC/iSCSI) Max. 960 HDDs Advanced Eco-friendly Function M Series ensures the protection of data at businesses and provides high M Series promotes environmental conservation by actively adopting performance and high availability to support high-speed access. eco-friendly components that save power. High-speed components and interfaces such as SSD are supported. The eco-friendly design employs the 80PLUS® PLATINUM (for M510 and Data can automatically be allocated to a suitable device according to its M710) or 80PLUS® GOLD (for M110 and M310) certified high-efficiency access frequency. power supplies as well as low-power processors. Main components are made redundant and protected. M Series can be used even in 40°C(104°F) environments, contributing to a Original high availability technologies such as Super Phoenix technology reduced electricity cost. are adopted. Power consumption is reduced by providing a visualization of the power Superior security functions such as self-encrypting drives are supported. consumption and implementing the autonomous MAID function. ENERGY STAR certified. (M110) Easy Installation & Operation IT Cost Optimization M Series reduces the workload of managing storage by offering autonomous M Series contributes to the reduction of TCO by optimizing the operations utilizing virtualization technologies and easy-to-use GUI. investment cost and making daily operations highly efficient. The advanced dynamic pool enables the expansion of capacity and performance Devices (SAS, nearline SAS, and SSD) and interfaces (FC, iSCSI, without stopping operations. and SAS) can be selected according to your purpose, optimizing Thin provisioning optimally allocates storage capacity in a virtual environment. the investment cost. A backup site can be easily and economically constructed by using an iSCSI The management software is bundled with M110. interface. The management workload can be reduced with virtualized system Data can be migrated and moved between storage units without using an FC switch. operations. The user-friendly GUI makes storage management and operation easy. 2 3 M Series Disk Array Improving the operating efficiency of a server virtualization environment by integrating with a VMware environment Innovate virtualization with NEC Storage M Series M Series supports VMware vStorage APIs for Array Integration (VAAI), a storage API provided by VMware, Inc. By incorporating this API, operations that were processed on a server in the past can be processed on the M Series product itself. These operations include the replication and migration of Assuring business performance through automatic optimization based on SLA* In a server virtualization environment, a single task placing a high load on the server can prevent other tasks from obtaining sufficient resources, leading to degraded server performance. To assure stable performance, NEC Storage M series sets upper and lower limits to each logical disk to control the amount of I/O. Setting a small value as the upper limit of a task whose priority is low allows resources to virtual machines, initialization of new virtual machines, and exclusive control of storage areas. Performing these operations without a server reduces Before After Performance of important task degraded I/O upper control suppresses the load of a high-load task, and I/O lower control ensures the required performance of an important task. Task level Important Average Important Server A Average Average Stable performance C (IOPS) A Ensure performance by setting a lower limit. stabilizes the operations of the entire system, allowing you to meet the demands of SLAs that guarantee Quality of Service. B B C M510 M310 M510 M710 Innovate business continuity with NEC Storage M Series A B C Load suppression (IOPS) A *SLA:Service Level Agreement M310 M110 Storage B preferentially acquire the resources it needs. By prioritizing tasks and optimizing resource allocation automatically, NEC Storage M series M110 Server High load Storage Performance degradation be fairly allocated to other tasks. On the other hand, setting a large value as the lower limit of an important task allows that task to Average High load server loads, enhances the operational efficiency of the entire virtualization environment, and increases overall performance. C Suppress performance to a certain level by setting an upper limit. M710 RAID protects against double failures, handling increasing data capacities The HDD capacity is becoming larger as business information rapidly increases. There is also a risk of data loss because the second HDD can fail while recovering a damaged HDD. M Series supports the NEC original RAID triple mirror feature that achieves the high-speed performance of RAID-1 and the reliability of RAID-6 in addition to the double parity configuration of RAID-6, responding to demands for both large capacities and high reliability. M Automatically allocating data to a suitable device according to access frequency Application server Application server Application server Series can maintain its performance during failures with its design that duplicates main components, establishing a level of reliability equivalent to high-end models of storage units. M Series enables the creation of layers of different types of devices such as SSD that allows high-speed data access, high-performance SAS HDD, Automatically allocating the stored data to a suitable device according to access frequency (Logical disk unit) Automatically allocating the stored data to a suitable device according to access frequency (Block-data unit) and high-capacity and low bit-cost nearline SAS HDD. The stored data is NEC Storage M Series automatically re-allocated in suitable storage layers by routine monitoring so that frequently accessed data is moved to a SSD pool and infrequently accessed data is moved to a nearline SAS pool. This maximizes storage performance and optimizes the investment cost of High High SSD pool Cost Performance SAS pool Low Low Nearline SAS pool M110 M310 M510 M710 Innovate interoperability with NEC Storage M Series Intuitive GUI allows even first-time users to easily manage the storage unit the storage units. M110 M310 M510 Hierarchical pool M710 component, such as a connected server, can be checked in a visual web browser window. Navigation windows show the methods for specifying SSD L2 cache & persistent write, ensuring stable, high-speed performance The easy-to-understand GUI environment eliminates errors during read operation. Write Controller throughput of frequently accessed data was improved to remove hot spots by using SSD, which cache can continue FastWrite operations by storing redundant data in SSD when an error occurs the replication settings, changing the capacity, and responding to failures. Application server M Series was developed to achieve higher levels of performance through utilization of SSD. The has a readout performance of superior speed, as an L2 cache. In addition, a persistent write NEC Storage M Series Controller Persistent write M110 SSD L2 cache Continuing FastWrite operations by maintaining redundant data when an error occurs in one controller SSD Removing hot spots by storing frequently accessed data in a SSD in one controller. M110 M310 M510 The storage capacity, disk load, and operational status of each M710 M310 M510 M710 iSCSI RDR economically counters disaster through remote replication Main site Backup site Low-cost remote replication without an FC-IP converter Constructing a backup site to protect valuable data against disasters Advanced dynamic pool, expanding the capacity and performance simply by adding HDD such as earthquakes and fires can cost a great deal of money and Storage performance HDD 30 Add an HDD The flexibility to respond to a sudden increase in data is vital in this age of constant change. NEC Number of HDDs HDD Storage M Series offers an advanced dynamic pool that NEC recently developed by elevating the 20 Add an HDD level of existing virtual pools. The advanced dynamic pool enables the automatic increase in pool 10 capacity during capacity shortages simply by adding HDD, and improved performance of the Workload resources. With M Series, an IP line is used with iSCSI, making an FC-IP converter unnecessary and enabling the development of cost-efficient M310 M510 The thin provisioning feature virtually allocates the capacity of a physical volume to a logical volume and adds HDD when the capacity of physical volume is insufficient. The storage usage is maximized because you can minimize the difference between the is not necessary to stop operations or adjust a schedule to change the capacity because HDD can be added without stopping jobs. 4 M510 iSCSI FC or iSCSI operation is possible due to a reduction of line cost. M110 M310 M510 M710 DDR Master RDR DDR Replica Replica M Series Capacity recognized as LUN:10TB Replica M Series Add hard disk drives as required M710 Assign actual capacity when data is written Virtual capacity:10TB Actual capacity:5TB HDD HDD HDD HDD HDD Free:10TB Used:5TB Assigned capacity monitoring Storage Manager Pool capacity: 15TB Advanced dynamic pool HDD Direct backup/restoration in coordination with NEC Storage HS Application server Logical disk used space and the physical volume capacity. The initial investment cost and power consumption can also be reduced. In addition, it M310 Public line M710 Thin provisioning, optimally allocating storage capacity in a virtualized environment M110 iSCSI disaster prevention and response measures. In addition, low-cost entire pool by automatically optimizing data allocation to distribute data. M110 FC or iSCSI Assignment history accumulation and analysis To coordinate with backup archive storage NEC Storage HS, servers and software dedicated to backup were required. NEC Storage M series can now perform direct backup/restoration because its coordination function has been enhanced. Instead of performing a full backup each time, only one full backup is required, Threshold value: 13TB after which incremental backups are performed. This decreases the backup time significantly and allows all Management server processes from data management to backup/restoration to be automated, leading to reduced costs. M110 M310 M510 NEC Storage M series NEC Storage HS series Data (increment) Data (increment) Data Data One full backup followed by incremental backups 12 9 3 6 A full backup is generated in NEC Storage HS series. M710 5 M Series Disk Array NEC Storage M110 Green innovation with NEC Storage M Series Model*1 Rack mount configuration Host interface Host ports (Maximum)*1 Installed capacity Cache memory*1 Battery backup time RAID level*2 Disk interface SAS HDD Type, Disk drive Nearline SAS HDD capacity, specifications SAS SSD and Encryption SAS / Nearline SAS HDD rotation speed Encryption SAS SSD SAS HDD Nearline SAS HDD Capacity*3*4 SAS SSD (Maximum) Encryption SAS / Nearline SAS HDD Encryption SAS SSD Number of drives to be installed*5 Supported OS*6 Disk array controller (U count) Dimensions (WxDxH) Disk enclosure (U count) Disk array controller Weight Disk enclosure Input voltage SAS HDD Disk array Power consumption controller*8 Nearline SAS HDD (Maximum / at 25°C) Disk SAS HDD enclosure Nearline SAS HDD Temperature Ambient conditions Humidity Reducing power consumption with advanced power saving technology To offer top-class eco-friendly storage units, NEC has developed M Series by applying advanced energy saving technology so that its power consumption is significantly less than previous models. It promotes power saving of the entire storage unit by incorporating a low-power processor as its CPU and enabling autonomous control. For the power supply, M Series employs the 80PLUS PLATINUM (for M510 and M710)* or 80PLUS GOLD (for M110 and M310) certified high-efficiency power supplies. In addition, M Series incorporates as many power saving components as possible, and achieves a significant reduction in the total number of components. M Series can be used in 40°C(104°F) environments, reducing the power consumed by air conditioning. *The disk enclosures employ 80 PLUS GOLD certified power supplies. M110 M310 M510 NEC Storage M310 M710 Model Rack mount configuration Realizing low-power operations by visualization of power consumption and autonomous device control Visualization of power consumption Energy efficient operation by autonomous control Host interface Host ports (Maximum) Cache memory Installed capacity Battery backup time RAID level*2 environment can be managed with real-time visualizations. In addition, components such as CPU, fan and HDD can autonomously control power consumption based on storage unit usage, Energy efficient operations are promoted by reducing unnecessary power consumption M110 M310 M510 Disk drive specifications SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD Number of drives to be installed 6 Supported OS* Disk array controller (U count) Dimensions (WxDxH) Disk enclosure (U count) Disk array controller Weight Disk enclosure Input voltage SAS HDD Disk array Power consumption controller*8 Nearline SAS HDD (Maximum / at 25°C) Disk SAS HDD enclosure Nearline SAS HDD Temperature Ambient conditions Humidity Autonomous control M710 Saving power resources with the autonomous MAID function Type, capacity, and rotation speed Capacity*3*4 (Maximum) I/O count as much as possible when the storage unit is idle. Disk interface Reduce power consumption depending on usage Power consumption(kwh) The power consumption of all M Series units in the same infrastructure The larger the system is, the more power is consumed and the more the In use Copying In use Stopped Rack mount configuration Host interface Host ports (Maximum) running cost is increased. M Series adopts MAID (Massive Array of Inactive Disks) technology to promote energy efficiency. For example, by Business volume managing a job schedule in pool units with dedicated software, the Cache memory Backup volume Disk interface Disk drive specifications power. M Series can now use up to 30% less power than previous NEC M310 M Series When MAID technology has been adopted Time M510 M710 Backup volume ON OFF ON Type, capacity, and rotation speed SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD Number of drives to be installed Supported OS*6 Disk array controller (U count) Dimensions (WxDxH) Disk enclosure (U count) Disk array controller Weight Disk enclosure Input voltage Disk array controller*8 Power consumption SAS HDD (Maximum / at 25°C) Disk enclosure Nearline SAS HDD Temperature Ambient conditions Humidity Capacity*3*4 (Maximum) Backup job Business volume Installed capacity Battery backup time RAID level*2 motor of a backup disk drive that is not being used is turned off to save M110 OFF Model Rack mount configuration Host interface Host ports (Maximum) Cache memory Advanced security functions such as data encryption and personal information leakage prevention Application server Read & write encrypt data in the HDD. This function prevents data leakage when the M Series features a variety of security functions, including restrictions on access to logical disks, audit of logs and other records, and prevention of erroneous operations. M110 M310 M510 M710 Data to be written to or read from the HDD is not encrypted. Since there is no overhead due to data encryption, performance does not degrade. Data recorded in an encryption HDD is encrypted. Authentication key always threatened. M Series uses a Self-encrypting drive (SED) to HDD is inappropriately removed, lost, stolen, or damaged. Furthermore, Register authentication key NEC Storage Manager Authentication Prevents data from being accessed if the authentication key does not match Encryption HDD Encryption HDD Encryption HDD Even if the HDD is removed without permission, the data in the HDD cannot be accessed without the correct authentication key. Since data in the HDD is encrypted, it is not possible to decrypt it. XXXXXX XXXXXX Installed capacity Battery backup time RAID level*2 Disk interface Disk drive spec. Type, capacity, and rotation speed SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD SAS HDD Nearline SAS HDD SAS SSD Encryption SAS / Nearline SAS HDD Encryption SAS SSD Number of drives to be installed Supported OS*6 Disk array controller (U count) Dimensions (WxDxH) Disk enclosure (U count) Disk array controller Weight Disk enclosure Input voltage Disk array controller*8 Power consumption SAS HDD (Maximum / at 25°C) Disk enclosure Nearline SAS HDD Temperature Ambient conditions Humidity Capacity*3*4 (Maximum) Removing the HDD without permission 6 NEC Storage M510 Supporting 3.5-inch Drive NEC Storage M510 Supporting 2.5-inch Drive For a disk enclosure supporting a 3.5-inch drive, up to 64 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 32 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 32 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 3.5-inch drive, up to 64 disk enclosures can be connected to a disk array controller. Up to 12 drives can be installed in a disk enclosure. Up to 24 drives can be installed in a disk enclosure. Fibre channel (8 Gbps / 16 Gbps), iSCSI (10 Gbps (Optical / Copper)) FC x 32, iSCSI x 16, FC x 2 to 24 + iSCSI (Optical) x 2 to 12, or FC x 2 to 24 + iSCSI (Copper) x 4 to 12 48 GB or 96 GB Unlimited (Save to a dedicated area.) RAID-0, 1, 5, 6, 10, 50, 60, TM SAS 3.0 (12 Gbps) 2.5-inch 600 GB, 1.2 TB, 1.8 TB (10,000 rpm), 300 GB, 600 GB (15,000 rpm) 3.5-inch 2 TB, 4 TB, 6 TB (7,200 rpm) 3.5-inch 200 GB, 400 GB, 1.6 TB 2.5-inch 200 GB, 400 GB, 1.6 TB 2.5-inch 600 GB (10,000 rpm / 15,000 rpm) 3.5-inch 4 TB (7,200 rpm) 3.5-inch 200 GB 2.5-inch 200 GB 1,088.4 TB 3,625.1 TB 849.6 TB 849.6 TB 2,426.4 TB 356.0 TB 105.9 TB 105.9 TB 3 to 768 FC: Windows, Linux, VMware, HP-UX, Solaris, AIX iSCSI / SAS: Windows, Linux, VMware 482x633.8x175.4 mm (4U, without front bezel) / 482x643.8x175.4 mm (4U, with front bezel)*7 482x548.5x87.4 mm (2U, without front bezel) / 482x558.5x87.4 mm (2U, with front bezel)*7 48 kg or less 48 kg or less 29 kg or less 26 kg or less 100 to 240 VAC, single phase, 50/60Hz, 48 VDC (975VA) 965W (975VA) / 825W 965W / 825W 350W (350VA) / 285W 295W (300VA) / 230W 5 to 40°C (when operating), -10 to 60°C (when not operating) 10 to 80% RH (when operating), 5 to 80% RH (when not operating) NEC Storage M710 Innovate security with NEC Storage M Series The security of storage units that store confidential business data is NEC Storage M310 Supporting 3.5-inch Drive NEC Storage M310 Supporting 2.5-inch Drive For a disk enclosure supporting a 3.5-inch drive, up to 19 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 19 disk enclosures can be connected to a disk array controller. If disk enclosures supporting 3.5-inch and 2.5-inch drives are used together, disk enclosures can be connected to a disk array controller under the condition that total number of slots is 480 or less. If disk enclosures supporting 2.5-inch and 3.5-inch drives are used together, disk enclosures can be connected to a disk array controller under the condition that total number of slots is 480 or less. Up to 12 drives can be installed in a disk array controller or disk enclosure. Up to 24 drives can be installed in a disk array controller or disk enclosure. Fibre channel (8 Gbps / 16 Gbps), iSCSI (1 Gbps (Copper) / 10 Gbps (Optical / Copper)) FC x 8, iSCSI x 8, or FC x 4 + iSCSI (10 Gbps) x 4 24 GB or 48 GB Unlimited (Save to a dedicated area.) RAID-0, 1, 5, 6, 10, 50, 60, TM SAS 3.0 (12 Gbps) 2.5-inch 600 GB, 1.2 TB, 1.8 TB (10,000 rpm), 300 GB, 600 GB (15,000 rpm) 3.5-inch 2 TB, 4 TB, 6 TB (7,200 rpm) 3.5-inch 200 GB, 400 GB, or 1.6 TB 2.5-inch 200 GB, 400 GB, or 1.6 TB 2.5-inch 600 GB (10,000 rpm / 15,000 rpm) 3.5-inch 4 TB (7,200 rpm) 3.5-inch 200 GB 2.5-inch 200 GB 680.2 TB 1,132.8 TB 531.0 TB 265.5 TB 758.2 TB 222.5 TB 33.1 TB 66.2 TB 3 to 240 (3.5-inchHDD), 3 to 480 (2.5-inchHDD) FC: Windows, Linux, VMware, HP-UX, Solaris, AIX iSCSI / SAS: Windows, Linux, VMware 482x556.0x87.4 mm (2U, without front bezel) / 482x566.0x87.4 mm (2U, with front bezel)*7 482x548.5x87.4 mm (2U, without front bezel) / 482x558.5x87.4 mm (2U, with front bezel)*7 33 kg or less 29 kg or less 29 kg or less 26 kg or less 100 to 240 VAC, single phase, 50/60Hz, 48 VDC 565W (570VA) / 455W 510W (515VA) / 400W 350W (350VA) / 285W 295W (300VA) / 230W 5 to 40°C (when operating), -10 to 60°C (when not operating) 10 to 80% RH (when operating), 5 to 80% RH (when not operating) NEC Storage M510 Application server Model Storage models. NEC Storage M110 Supporting 3.5-inch Drive NEC Storage M110 Supporting 2.5-inch Drive For a disk enclosure supporting a 3.5-inch drive, up to 9 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 4 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 4 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 3.5-inch drive, up to 8 disk enclosures can be connected to a disk array controller. Up to 12 drives can be installed in a disk array controller or disk enclosure. Up to 24 drives can be installed in a disk array controller or disk enclosure. Fibre channel (8 Gbps/16 Gbps), iSCSI (1 Gbps (Copper)/10 Gbps (Optical/Copper)), SAS (12 Gbps) FC x 8, iSCSI x 8, SAS x 8, or FC x 4 + iSCSI (10 Gbps) x 4 16 GB Unlimited (Save to a dedicated area.) RAID-0, 1, 5, 6, 10, 50, 60, TM SAS 3.0 (12 Gbps) 2.5-inch 600 GB, 1.2 TB, 1.8 TB (10,000 rpm), 300 GB, 600 GB (15,000 rpm) 3.5-inch 2 TB, 4 TB, 6 TB (7,200 rpm) 3.5-inch 200 GB, 400 GB, 1.6 TB 2.5-inch 200 GB, 400 GB, 1.6 TB 2.5-inch 600 GB (10,000 rpm / 15,000 rpm) 3.5-inch 4 TB (7,200 rpm) 3.5-inch 200 GB 2.5-inch 200 GB 170.0 TB 566.4 TB 13.2 TB 13.2 TB 379.1 TB 55.6 TB 1.6 TB 1.6 TB 3 to 120 Windows, Linux, VMware 7 482 x 556.0 x 87.4 mm (2U, without front bezel) / 482 x 566.0 x 87.4 mm (2U, with front bezel)* 482 x 548.5 x 87.4 mm (2U, without front bezel) / 482 x 558.5 x 87.4 mm (2U, with front bezel)*7 33 kg or less 29 kg or less 29 kg or less 26 kg or less 100 to 240 VAC, single phase, 50/60Hz, 48 VDC 520W (525VA) / 425W 465W (470VA) / 370W 350W (350VA) / 285W 295W (300VA) / 230W 5 to 40°C (when operating), -10 to 60°C (when not operating) 10 to 80% RH (when operating), 5 to 80% RH (when not operating) NEC Storage M710 Supporting 3.5-inch Drive NEC Storage M710 Supporting 2.5-inch Drive For a disk enclosure supporting a 3.5-inch drive, up to 80 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 40 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 2.5-inch drive, up to 40 disk enclosures can be connected to a disk array controller. For a disk enclosure supporting a 3.5-inch drive, up to 80 disk enclosures can be connected to a disk array controller. Up to 12 drives can be installed in a disk enclosure. Up to 24 drives can be installed in a disk enclosure. Fibre channel (8 Gbps / 16 Gbps), iSCSI (10 Gbps (Optical / Copper)) FC x 48*9, iSCSI x 24*9, FC x 2 to 40 + iSCSI (Optical) x 2 to 20*9, or FC x 2 to 40 + iSCSI (Copper) x 4 to 20*9 96 GB or 192 GB Unlimited (Save to a dedicated area) RAID-0, 1, 5, 6, 10, 50, 60, TM SAS 3.0 (12 Gbps) 2.5-inch 600 GB, 1.2 TB, 1.8 TB (10,000 rpm), 300 GB, 600 GB (15,000 rpm) 3.5-inch 2 TB, 4 TB, 6 TB (7,200 rpm) 3.5-inch 200 GB, 400 GB, or 1.6 TB 2.5-inch 200 GB, 400 GB, or 1.6 TB 2.5-inch 600 GB (10,000 rpm / 15,000 rpm) 3.5-inch 4 TB (7,200 rpm) 3.5-inch 200 GB 2.5-inch 200 GB 1,360.5 TB 4,531.4 TB 1,062.0 TB 1,062.0 TB 3,033.0 TB 445.1 TB 132.4 TB 132.4 TB 3 to 960*9 FC: Windows, Linux, VMware, HP-UX, Solaris, AIX iSCSI / SAS: Windows, Linux, VMware 482x633.8x175.4 mm (4U, without front bezel) / 482x643.8x175.4 mm (4U, with front bezel)*7 482x548.5x87.4 mm (2U, without front bezel) / 482x558.5x87.4 mm (2U, with front bezel)*7 48 kg or less 48 kg or less 29 kg or less 26 kg or less 100 to 240 VAC, single phase, 50/60Hz 1,190W (1,200VA) / 1,065W 1,190W (1,200VA) / 1,065W 350W (350VA) / 285W 295W (300VA) / 230W 5 to 40°C (when operating), -10 to 60°C (when not operating) 10 to 80% RH (when operating), 5 to 80% RH (when not operating) *1: The M110 supports a dual controller model and a single controller model. The single controller model supports 4 ports and an 8 GB cache memory. *2: Since RAID-0 does not have redundancy, data is lost if an error occurs in a drive. Therefore, it is strongly recommended to use a RAID level having redundancy. If you want to use RAID-0, please contact NEC first. The RAID levels available for an SSD are RAID-1, 5, 6, 10, 50, and 60. *3: Calculated with 1 GB = 1,0243 bytes and 1 TB = 1,0244 bytes. *4: The number indicates the maximum capacity when RAID-5 is configured by using the maximum-size drive of each drive type. *5: Up to 12 SSDs can be installed in M110. *6: There are restrictions on disk devices to be connected for the described operating systems. For details, please contact NEC. *7: The front bezel is sold separately. *8: For M110 and M310, the power consumption value is when an iSCSI host interface is used. For M510 and M710, the power consumption value is when an FC host interface is used. The power consumption may differ for other configurations. *9: Host ports and drives are added exclusively, so this number indicates the maximum number of host ports and drives, respectively. 7