M100 Datasheet (PDF)

M100 Disk array
AN ENTRY-LEVEL DEVICE WITH THE OPERABILITY AND FUNCTIONALITY OF A HIGHER CLASS
Complete setup in a matter of minutes
Simplified initial setup procedure: with the preinstalled management
software, just select the desired capacity and RAID level, and let M100
Disk Array perform its own settings to enable the best performance.
User-friendly GUI for storage management
The highly visual Web browser screens let you quickly grasp the
status of storage capacity, disk load, and connected servers. Even
first-time users, can easily make changes to the replication settings
or capacity, and can handle fault in the event of a failure.
Advanced power-saving design
M100 Disk Array slashes previous power consumption levels to
achieve one of the best power ratings in the industry. It uses a powerefficient processor and autonomously controls the operating mode
to reduce the power consumption of the entire system. Low-power
components have been used to the greatest extent possible.
Easily ramp up capacity and performance
High performance & availability
Advanced eco features
Easy to install & operate
Extremely economical
M100 Disk Array offers a newly developed Advanced Dynamic Pool
technology. Pool capacity can be increased simply by adding hard
disk drives. The data will be automatically organized into the optimal
configuration to raise the performance of the entire data pool.
Non disturbing data backup
M100 Disk Array provides a snapshot function to save only the
modified data and a function to replicate an entire data volume
without disrupting operations. The replicated volume can be used for
tape backup, batch processing, or tests, using actual data.
Thin provisioning in virtual environment
Answering needs, the capacity of physical volumes can be allocated to
virtual drives and hard disk drives added without disrupting operations.
In this way, capacity usage is optimized, improving utilization, reducing
initial investment layout, and lowering power consumption. There is no
inefficient stoppage and schedule adjustement.
M100 DISK ARRAY
Advanced eco features
H
igh performance
& availability
• Silent and Autonomously switches
to low-power mode
• Uses a power-efficient processor
with a TDP (thermal design
power) of 30 W
• Includes a highly efficient power
supply
• Operates in environments with
temperatures up to 40ºC, reducing
air conditioning usage
•U
ses duplication and redundancy
design for critical components
Extremely economical
Easy
to install & operate
• Excellent cost-performance ratio
• Bundled management software
• iSCSI interface enables economical
• No management server required
• Setup is simple and quick
• Can be easily managed and
system configuration
• Capacity and performance can
Clustered application servers
Number of
HDDs
Backup server
server
storage performance
HDD
operated thanks to an intuitive,
user-friendly GUI (CLI supported)
• Executes self-diagnosis and
displays appropriate response
measures if faults occur
• Firmware updates can be applied
during operation
be increased just by adding
hard disk drives
•C
an be managed remotly
through status monitoring and
log acquisition
•U
ses a high-speed interface
LUN capacity recognized by
the server: 10TB
30
add an HDD
Real capacity can be allocated
according to the usage.
logical Disk
Virtual Capacity :
10TB
HDD
Monitoring the capacity
and threshold
Real Capacity :
5TB
20
add an HDD
M100 Disk array
NEC Storage
Manager
HDD can be added
when needed
Replication (Complete Copy)
10
Workload
advanced Dynamic Pool
HDD
Snapshot (updated Difference)
HDD
HDD
HDD
HDD
HDD
HDD
Pool Capacity: 15TB
Threshold: 13TB
Not Used : 10TB
Storing and analyzing
the record of
the allocated capacity
Used: 5TB
Management Server
SPECIFICATIONS
M100 Disk Array
Supporting 3,5“ Drive
M100 Disk Array
Supporting 2,5“ Drive
Seven disk enclosures supporting 3.5“ drives
or three disk enclosures supporting 2.5“ drives
can be connected to the disk array controller.
Three disks enclosures supporting 2,5“ drives
or six disk enclosures supporting 3,5“ drives
can be connected to the disk array controller.
The disk array controller or
disk enclosure can house up to 12 drives
The disk array controller
or disk enclosure can house up to 24 drives
Model
Chassis structure (rack mount)
Host interface
Fibre Channel (8Gbps), iSCSI (1 Gbps or 10 Gbps)
Number of host ports *1
Capacity*1
Cache
memory*2
Backup method
FC: 8 or 4, iSCSI: 4
8GB
Save to flash memory
RAID level*2
Drive
specifications
Device capacity
*3 *4
(maximum
capacity)
Number of mounted drives *5
Chassis
dimensions
(WxDxH)
Type /
Capacity /
Rotation
speed
3.5“ 300 GB, 450 GB, 600 GB (15,000 rpm)
2.5“ 300 GB, 450 GB, 600 GB (10.000 rpm)
Nearline
SAS HDD
3.5“ 1 TB, 2 TB (7,200 rpm)
2.5“ 1 TB (7,200 rpm)
SSD
3.5“ 400 GB
2.5“ 100 GB
Encryption
SAS HDD
3.5“ 600 GB (15,000 rpm)
2.5“ 600 GB (10,000 rpm)
48.9 TB
48.9 TB
Nearline SAS HDD
166.8 TB
83.7 TB
SAS SSD
3.7 TB
897 GB
Encryption SAS HDD
48.9 TB
48.9 TB
Storage Control
Replication
Storage Control
Resource Control
High Availability
Power conditions
31 kg max.
29 kg max.
100 to 240 VAC, single-phase 50/60 Hz
Maximum power Disk array controller
cosumption
(when operating
in a 25°C
Disk enclosure
environment)
Ambient
operating
conditions
PRODUCT NAME
Performance Management
482 x 513.2 x 87.8 mm (2U, no front bezel) / 482 x 545.2 x 87.8 mm (2U, with front bezel) *7
Disk enclosure
SAS HDD
Storage Management
482 x 513.2 x 87.8 mm (2U, no front bezel) / 482 x 545.2 x 87.8 mm (2U, with front bezel) *7
Disk enclosure
( U count)
Disk array controller
SAS HDD
Device Management
Windows, Linux, VMware
Disk array controller
(U count)
Weight
SAS (6Gbps)
TYPE
M100 Disk Array
Supporting 2,5“ Drive
3 to 96
Supported operating systems *6
RAID-0, 1, 5, 6, 10, 50, 60, TM
Disk interface
M100 Disk Array
Supporting 3,5“ Drive
Model
Temperature
400 W
400 W
290 W
290 W
5 to 40°C (41 to 104°F) (while operating), -10 to 60°C (14 to 140°F) (Non operating)
Humidity
10 to 80% RH (while operating), 5 to 80% RH (Non-Operating)
M100 (FC)
M100 (iSCSI)
NEC Storage Manager Suite
NEC Storage PerformanceMonitor Suite
NEC Storage PerformanceMonitor
NEC Storage PerformanceNavigator
NEC Storage Manager Express *10
NEC Storage ControlCommand Media Kit
•
•
•
•
•
•
•
•
•
•
•
•
Basic storage functions for multi-array management
Bundle of NEC Storage PerformanceMonitor and NEC Storage PerformanceNavigator
Function for real-time performance monitoring of disk array
Function for efficient perfromance analysis
Basic storage management functions embedded in NEC Storage
CLI for data replication, power savings, and volume protection on application servers.
NEC Storage DynamicDataReplication*11
NEC Storage DynamicDataReplication Express*10 *11
NEC Storage RemoteDataReplication *11
NEC Storage RemoteDataReplication Asynchronous *11
NEC Storage ReplicationControl SQL Option *11
NEC Storage ReplicationControl FileSystem Option *11
•
•
•
•
•
•
•
•
–
–
•
•
Function for volume replication and snapshot within the same disk array
Embedded CLI for volume replication and snapshot within the same disk array
Function for volume replication across different disk arrays
Function for volume replication across different disk arrays over a low speed network
Option function for non-disruptive backup of Microsoft® SQL Server TM
Option function for non-disruptive backup of file system
NEC Storage StoragePowerConserver *10
NEC Storage VolumeProtect
NEC Storage ThinProvisioning *10 *12
NEC Storage PathManager *10
•
•
•
•
•
•
•
•
Function to save storage power consumption by control of HDD Rotation
Function for tamper proof and ensure the integrity of volume data
Function to enhance storage usage efficiency by virtual capacity
Path redundancy function
®2011 NEC. The information and specification contained in this
publication are subject to modification without prior notice. All
other names of products and brands cited are the property of
their respective owners. Products can be photographed with the
optional components available. NEC declines all responsibility in
the case of photographic or typing errors. Photos and documents
are not contractual.
Ref : Datasheet - uk / NEC M100 Disk Array October 2011
NEC Corporation
7-1, Shiba 5-chome, Minato-ku, Tokyo, 108-8001 Japan
www.nec.com
FEATURE
*1 : Dual controller model capacity *2 : The RAID-0 does not include redundancy, so data will be lost if any of the disks fail. NEC strongly
recommends using a RAID level with redundancy. Please contact NEC before implementing a RAID-0. *3 : Capacity is calculated based on a
conversion factor of 1GB = 1.000.000.000 bytes and 1 TB = 1.000.000.000.000 bytes.
*4 : The maximum capacity is calculated based on the assumption that a drive with the maximum capacity is selected for each drive and that
a RAID-5 is used. *5 : When using SSD, up to 12 drives can be connected. *6 : The disk array conncetion might be restricted depending on
the operating system used. Contact NEC for details. *7 : The front bezel is an optional extra. *10 : Bundled with the diskarray
*11 : Not supported in the Single Controller model *12 : To be supported from the 4th quarter of 2011
NEC IT Platform Solutions Division
Tel: +33 1 46 49 46 49
European Headquarters
29, rue des Hautes Pâtures - 92737 Nanterre Cedex France
www.nec-itplatform.com