M100 Disk array AN ENTRY-LEVEL DEVICE WITH THE OPERABILITY AND FUNCTIONALITY OF A HIGHER CLASS Complete setup in a matter of minutes Simplified initial setup procedure: with the preinstalled management software, just select the desired capacity and RAID level, and let M100 Disk Array perform its own settings to enable the best performance. User-friendly GUI for storage management The highly visual Web browser screens let you quickly grasp the status of storage capacity, disk load, and connected servers. Even first-time users, can easily make changes to the replication settings or capacity, and can handle fault in the event of a failure. Advanced power-saving design M100 Disk Array slashes previous power consumption levels to achieve one of the best power ratings in the industry. It uses a powerefficient processor and autonomously controls the operating mode to reduce the power consumption of the entire system. Low-power components have been used to the greatest extent possible. Easily ramp up capacity and performance High performance & availability Advanced eco features Easy to install & operate Extremely economical M100 Disk Array offers a newly developed Advanced Dynamic Pool technology. Pool capacity can be increased simply by adding hard disk drives. The data will be automatically organized into the optimal configuration to raise the performance of the entire data pool. Non disturbing data backup M100 Disk Array provides a snapshot function to save only the modified data and a function to replicate an entire data volume without disrupting operations. The replicated volume can be used for tape backup, batch processing, or tests, using actual data. Thin provisioning in virtual environment Answering needs, the capacity of physical volumes can be allocated to virtual drives and hard disk drives added without disrupting operations. In this way, capacity usage is optimized, improving utilization, reducing initial investment layout, and lowering power consumption. There is no inefficient stoppage and schedule adjustement. M100 DISK ARRAY Advanced eco features H igh performance & availability • Silent and Autonomously switches to low-power mode • Uses a power-efficient processor with a TDP (thermal design power) of 30 W • Includes a highly efficient power supply • Operates in environments with temperatures up to 40ºC, reducing air conditioning usage •U ses duplication and redundancy design for critical components Extremely economical Easy to install & operate • Excellent cost-performance ratio • Bundled management software • iSCSI interface enables economical • No management server required • Setup is simple and quick • Can be easily managed and system configuration • Capacity and performance can Clustered application servers Number of HDDs Backup server server storage performance HDD operated thanks to an intuitive, user-friendly GUI (CLI supported) • Executes self-diagnosis and displays appropriate response measures if faults occur • Firmware updates can be applied during operation be increased just by adding hard disk drives •C an be managed remotly through status monitoring and log acquisition •U ses a high-speed interface LUN capacity recognized by the server: 10TB 30 add an HDD Real capacity can be allocated according to the usage. logical Disk Virtual Capacity : 10TB HDD Monitoring the capacity and threshold Real Capacity : 5TB 20 add an HDD M100 Disk array NEC Storage Manager HDD can be added when needed Replication (Complete Copy) 10 Workload advanced Dynamic Pool HDD Snapshot (updated Difference) HDD HDD HDD HDD HDD HDD Pool Capacity: 15TB Threshold: 13TB Not Used : 10TB Storing and analyzing the record of the allocated capacity Used: 5TB Management Server SPECIFICATIONS M100 Disk Array Supporting 3,5“ Drive M100 Disk Array Supporting 2,5“ Drive Seven disk enclosures supporting 3.5“ drives or three disk enclosures supporting 2.5“ drives can be connected to the disk array controller. Three disks enclosures supporting 2,5“ drives or six disk enclosures supporting 3,5“ drives can be connected to the disk array controller. The disk array controller or disk enclosure can house up to 12 drives The disk array controller or disk enclosure can house up to 24 drives Model Chassis structure (rack mount) Host interface Fibre Channel (8Gbps), iSCSI (1 Gbps or 10 Gbps) Number of host ports *1 Capacity*1 Cache memory*2 Backup method FC: 8 or 4, iSCSI: 4 8GB Save to flash memory RAID level*2 Drive specifications Device capacity *3 *4 (maximum capacity) Number of mounted drives *5 Chassis dimensions (WxDxH) Type / Capacity / Rotation speed 3.5“ 300 GB, 450 GB, 600 GB (15,000 rpm) 2.5“ 300 GB, 450 GB, 600 GB (10.000 rpm) Nearline SAS HDD 3.5“ 1 TB, 2 TB (7,200 rpm) 2.5“ 1 TB (7,200 rpm) SSD 3.5“ 400 GB 2.5“ 100 GB Encryption SAS HDD 3.5“ 600 GB (15,000 rpm) 2.5“ 600 GB (10,000 rpm) 48.9 TB 48.9 TB Nearline SAS HDD 166.8 TB 83.7 TB SAS SSD 3.7 TB 897 GB Encryption SAS HDD 48.9 TB 48.9 TB Storage Control Replication Storage Control Resource Control High Availability Power conditions 31 kg max. 29 kg max. 100 to 240 VAC, single-phase 50/60 Hz Maximum power Disk array controller cosumption (when operating in a 25°C Disk enclosure environment) Ambient operating conditions PRODUCT NAME Performance Management 482 x 513.2 x 87.8 mm (2U, no front bezel) / 482 x 545.2 x 87.8 mm (2U, with front bezel) *7 Disk enclosure SAS HDD Storage Management 482 x 513.2 x 87.8 mm (2U, no front bezel) / 482 x 545.2 x 87.8 mm (2U, with front bezel) *7 Disk enclosure ( U count) Disk array controller SAS HDD Device Management Windows, Linux, VMware Disk array controller (U count) Weight SAS (6Gbps) TYPE M100 Disk Array Supporting 2,5“ Drive 3 to 96 Supported operating systems *6 RAID-0, 1, 5, 6, 10, 50, 60, TM Disk interface M100 Disk Array Supporting 3,5“ Drive Model Temperature 400 W 400 W 290 W 290 W 5 to 40°C (41 to 104°F) (while operating), -10 to 60°C (14 to 140°F) (Non operating) Humidity 10 to 80% RH (while operating), 5 to 80% RH (Non-Operating) M100 (FC) M100 (iSCSI) NEC Storage Manager Suite NEC Storage PerformanceMonitor Suite NEC Storage PerformanceMonitor NEC Storage PerformanceNavigator NEC Storage Manager Express *10 NEC Storage ControlCommand Media Kit • • • • • • • • • • • • Basic storage functions for multi-array management Bundle of NEC Storage PerformanceMonitor and NEC Storage PerformanceNavigator Function for real-time performance monitoring of disk array Function for efficient perfromance analysis Basic storage management functions embedded in NEC Storage CLI for data replication, power savings, and volume protection on application servers. NEC Storage DynamicDataReplication*11 NEC Storage DynamicDataReplication Express*10 *11 NEC Storage RemoteDataReplication *11 NEC Storage RemoteDataReplication Asynchronous *11 NEC Storage ReplicationControl SQL Option *11 NEC Storage ReplicationControl FileSystem Option *11 • • • • • • • • – – • • Function for volume replication and snapshot within the same disk array Embedded CLI for volume replication and snapshot within the same disk array Function for volume replication across different disk arrays Function for volume replication across different disk arrays over a low speed network Option function for non-disruptive backup of Microsoft® SQL Server TM Option function for non-disruptive backup of file system NEC Storage StoragePowerConserver *10 NEC Storage VolumeProtect NEC Storage ThinProvisioning *10 *12 NEC Storage PathManager *10 • • • • • • • • Function to save storage power consumption by control of HDD Rotation Function for tamper proof and ensure the integrity of volume data Function to enhance storage usage efficiency by virtual capacity Path redundancy function ®2011 NEC. The information and specification contained in this publication are subject to modification without prior notice. All other names of products and brands cited are the property of their respective owners. Products can be photographed with the optional components available. NEC declines all responsibility in the case of photographic or typing errors. Photos and documents are not contractual. Ref : Datasheet - uk / NEC M100 Disk Array October 2011 NEC Corporation 7-1, Shiba 5-chome, Minato-ku, Tokyo, 108-8001 Japan www.nec.com FEATURE *1 : Dual controller model capacity *2 : The RAID-0 does not include redundancy, so data will be lost if any of the disks fail. NEC strongly recommends using a RAID level with redundancy. Please contact NEC before implementing a RAID-0. *3 : Capacity is calculated based on a conversion factor of 1GB = 1.000.000.000 bytes and 1 TB = 1.000.000.000.000 bytes. *4 : The maximum capacity is calculated based on the assumption that a drive with the maximum capacity is selected for each drive and that a RAID-5 is used. *5 : When using SSD, up to 12 drives can be connected. *6 : The disk array conncetion might be restricted depending on the operating system used. Contact NEC for details. *7 : The front bezel is an optional extra. *10 : Bundled with the diskarray *11 : Not supported in the Single Controller model *12 : To be supported from the 4th quarter of 2011 NEC IT Platform Solutions Division Tel: +33 1 46 49 46 49 European Headquarters 29, rue des Hautes Pâtures - 92737 Nanterre Cedex France www.nec-itplatform.com