Product family datasheet PrevaLED Cube AC G2 Spot-, Down- and Wallmount Light Engines and Modules Areas of application _ Suitable for diffuser and reflector luminaires _ Hospitality, hotels, restaurants _ Public and commercial buildings _ Offices _ Secondary rooms, garages, storerooms, cellars __ Product benefits _ Enables low-cost and compact luminaire designs _ Low profile _ Future-proof dimensions for reliable designs _ Near Lambertian light distribution at 110° beam angle for high quality of light _ Protection against overheating due to thermal derating Product features _ Mains voltage driven LED engine _ Integrated control gear _ Diameter of light emitting surface: 61 mm _ Common mechanic and photometric interfaces _ Initial color consistency: < 3 SDCM _ Lifetime (L70/B50): 50,000 h (temperature at t point < 80 °C) acc. to IEC/PAS 62717 _ Temperature at t point (according to IEC/PASc62717): 70 °C p June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 1 of 9 Product family datasheet Technical data Electrical data Product description Nominal wattage Rated wattage Nominal voltage Input voltage range Power factor λ Type of current PL-CUBE-AC -1100-830-G2 12.0 W 12.50 W 230 V 220…240 V > 0.90 AC PL-CUBE-AC -1100-840-G2 12.0 W 11.30 W 230 V 220…240 V > 0.90 AC PL-CUBE-AC -2000-830-G2 27.8 W 27.80 W 230 V 220…240 V > 0.90 AC PL-CUBE-AC -2000-840-G2 25.3 W 25.30 W 230 V 220…240 V > 0.90 AC PL-CUBE-AC -3000-830-G2 42.7 W 37.60 W 230 V 220…240 V > 0.90 AC PL-CUBE-AC -3000-840-G2 38.4 W 33.80 W 230 V 220…240 V > 0.90 AC Product description Total useful luminous flux Luminous efficacy Color temperature Color rendering index Ra Standard deviation of color matching Rated peak intensity PL-CUBE-AC -1100-830-G2 1100 lm 90 lm/W 3000 K 82 ≤3 sdcm 410 cd PL-CUBE-AC -1100-840-G2 1100 lm 94 lm/W 4000 K 82 ≤3 sdcm 410 cd PL-CUBE-AC -2000-830-G2 2000 lm 72 lm/W 3000 K ≤3 sdcm 740 cd PL-CUBE-AC -2000-840-G2 2000 lm 80 lm/W 3000 K ≤3 sdcm 740 cd PL-CUBE-AC -3000-830-G2 3000 lm 71 lm/W 3000 K 83 ≤3 sdcm 1110 cd PL-CUBE-AC -3000-840-G2 3000 lm 79 lm/W 4000 K 83 ≤3 sdcm 1110 cd Product description Nom. useful luminous flux 120° Rated useful luminous flux 120° PL-CUBE-AC -1100-830-G2 880 lm 880 lm PL-CUBE-AC -1100-840-G2 880 lm 880 lm PL-CUBE-AC -2000-830-G2 1600 lm 1600 lm PL-CUBE-AC -2000-840-G2 1600 lm 1600 lm PL-CUBE-AC -3000-830-G2 2400 lm 2400 lm PL-CUBE-AC -3000-840-G2 2400 lm 2400 lm Photometrical data __ June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 2 of 9 Product family datasheet Light technical data Product description Nominal beam angle Rated beam angle (half peak value) Starting time Warm-up time (60 %) PL-CUBE-AC -1100-830-G2 110 ° 110.00 ° < 0.5 s < 0.50 s PL-CUBE-AC -1100-840-G2 110 ° 110.00 ° < 0.5 s < 2.00 s PL-CUBE-AC -2000-830-G2 110 ° 110.00 ° < 0.5 s < 2.00 s PL-CUBE-AC -2000-840-G2 110 ° 110.00 ° < 0.5 s < 2.00 s PL-CUBE-AC -3000-830-G2 110 ° 110.00 ° < 0.5 s < 2.00 s PL-CUBE-AC -3000-840-G2 110 ° 110.00 ° < 0.5 s < 2.00 s Dimensions & weight __ Product description Rated width Construction length Rated height Product weight PL-CUBE-AC -1100-830-G2 82.0 mm 83.0 mm 21.00 mm 55.00 g PL-CUBE-AC -1100-840-G2 82.0 mm 83.0 mm 21.00 mm 55.00 g PL-CUBE-AC -2000-830-G2 82.0 mm 83.0 mm 21.00 mm 55.00 g PL-CUBE-AC -2000-840-G2 82.0 mm 83.0 mm 21.00 mm 55.00 g PL-CUBE-AC -3000-830-G2 82.0 mm 83.0 mm 21.00 mm 61.00 g PL-CUBE-AC -3000-840-G2 82.0 mm 83.0 mm 21.00 mm 61.00 g June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 3 of 9 Product family datasheet Product line drawing __ PL-CUBE-AC -1100-830-G2, PL-CUBE-AC -1100-840-G2, PLCUBE-AC -2000-830-G2, PL-CUBE-AC -2000-840-G2, PLCUBE-AC -3000-830-G2, PL-CUBE-AC -3000-840-G2 Temperatures & operating conditions Product description Maximum temperature at tc test point Ambient temperature range PL-CUBE-AC -1100-830-G2 85 °C 1) -20…+50 °C PL-CUBE-AC -1100-840-G2 85 °C 1) -20…+50 °C PL-CUBE-AC -2000-830-G2 85 °C 1) -20…+50 °C PL-CUBE-AC -2000-840-G2 85 °C 1) -20…+50 °C PL-CUBE-AC -3000-830-G2 85 °C 1) -20…+50 °C PL-CUBE-AC -3000-840-G2 85 °C 1) -20…+50 °C 1) Maximum at the Tc-point June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 4 of 9 Product family datasheet Lifespan Product description Lumen main. fact. at end of nom. life time Lifespan Nominal lamp life time Rated lamp life time Number of switching cycles PL-CUBE-AC -1100-830-G2 0.70 50000 h 1) 50000 h 50000 h 25000 0.70 50000 h 1) PL-CUBE-AC -1100-840-G2 PL-CUBE-AC -2000-830-G2 50000 h 50000 h 25000 0.70 50000 h 1) 50000 h 50000 h 25000 PL-CUBE-AC -2000-840-G2 0.70 50000 h 1) 50000 h 50000 h 25000 PL-CUBE-AC -3000-830-G2 0.70 50000 h 1) 50000 h 50000 h 25000 0.70 1) 50000 h 50000 h 25000 PL-CUBE-AC -3000-840-G2 50000 h 1) L70/B50 at Tc 70 °C Capabilities Product description Dimmable PL-CUBE-AC -1100-830-G2 No PL-CUBE-AC -1100-840-G2 No PL-CUBE-AC -2000-830-G2 No PL-CUBE-AC -2000-840-G2 No PL-CUBE-AC -3000-830-G2 No PL-CUBE-AC -3000-840-G2 No __ Certificates & standards Product description Energy consumption Standards PL-CUBE-AC -1100-830-G2 13 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471 PL-CUBE-AC -1100-840-G2 12 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471 PL-CUBE-AC -2000-830-G2 22 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE PL-CUBE-AC -2000-840-G2 21 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE PL-CUBE-AC -3000-830-G2 38 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE PL-CUBE-AC -3000-840-G2 35 kWh/1000h CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE Product description Energy efficiency class PL-CUBE-AC -1100-830-G2 A+ PL-CUBE-AC -1100-840-G2 A+ PL-CUBE-AC -2000-830-G2 A+ PL-CUBE-AC -2000-840-G2 A+ PL-CUBE-AC -3000-830-G2 A June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 5 of 9 Product family datasheet Product description Energy efficiency class PL-CUBE-AC -3000-840-G2 A Logistical data Product description Temperature range at storage PL-CUBE-AC -1100-830-G2 -20…85 °C PL-CUBE-AC -1100-840-G2 -20…85 °C PL-CUBE-AC -2000-830-G2 -20…85 °C PL-CUBE-AC -2000-840-G2 -20…85 °C PL-CUBE-AC -3000-830-G2 -20…85 °C PL-CUBE-AC -3000-840-G2 -20…85 °C Light Distribution __ PL-CUBE-AC -1100-830-G2, PL-CUBE-AC -2000-830-G2, PLCUBE-AC -3000-830-G2 PL-CUBE-AC -1100-840-G2, PL-CUBE-AC -2000-840-G2, PL-CUBE-AC -3000-840-G2 Application advice For more detailed application information and graphics please see product datasheet. June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 6 of 9 Product family datasheet Additional product information _ Installation by qualified electrician only. _ Please see the relevant application guides and instructions sheets for more detailed safety and mounting information. Additional information is available on request. _ The module / light engine has to be mounted to a proper heat sink in order to ensure that the maximum rated temperature at the T point will not be exceeded. c _ For safety reasons the LED light engine must not be operated if the housing is damaged. _ Complies with IEC/EN 62031 _ Complies with IEC/EN 61547 _ Complies with IEC/EN 61000-3-2 _ Complies with EN 55015, CISPR 15 _ Complies with IEC/EN 62717 _ Suitable only for operation with line voltage. _ Parallel connection is mandatory for safe electrical operation. Serial connection of LED modules is stronly discouraged. Unbalanced voltage drop in serial connection can cause hazardous overload and damage the LED module. _ Conducting paths on the circuit board must not be damaged or destroyed during installation. _ Suitable for luminaires of protection class I, grounding is mandatory to comply with safety standards. _ When used in a luminaire of protection class II compliance with the required safety standards has to be ensured by the luminaire manufacturer. _ This LED module is not recommended to be used in rooms with fast moving parts as the light modulation can cause stroboscopic effects. _ This LED module might interfere with displays and cameras due to modulation. _ The LED module itself and all its components must not be stressed mechanically. _ For optimal cooling a thermal interface material should be applied between LED module and heat sink. _ It is highly recommended to use a thermal interface material (TIM). The TIM needs to enable adequate heat transfer, during __ installation it has to be taken care not to create air inclusions between surfaces. For this purpose it is recommended to use a heat sink with even and clean surfaces. _ The module must not be attached to wood or other flammable materials. _ Protect against splashes! _ The module, as manufactured, has no inherent protection against corrosion. It is the user's responsibility to provide suitable protection against corrosive agents, such as moisture, condensation and other harmful elements. Sales and Technical Support Sales and Technical Support www.osram.com Download Data File Product Family Datasheet Family Datasheet: PrevaLED Cube AC G2 Brochures Technical application guide PrevaLED Cube AC (GB) Certificates ENEC Marks Approval 40038544 Certificates IEC Test Certificate CB54256_6281701_6281701_0001. June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 7 of 9 Product family datasheet Declarations of conformity EC-DoC PL-CUBE-AC-x000-8xx-230V-G2 CAD data CAD PrevaLED Cube AC CAD data 3-dim CAD-Datei STEP: PrevaLED Cube AC G2 CAD data 3-dim CAD-Data Parasolid: PrevaLED Cube AC G2 CAD data 3-dim CAD-Datei IGES: PrevaLED Cube AC G2 CAD data PDF CAD PrevaLED Cube AC 3D CAD data PDF CAD-Data 3D-PDF: PrevaLED Cube AC G2 Eulumdat EULUMDAT: PrevaLED Cube AC G2 CAD data CAD PrevaLED Cube AC Parasolid CAD data CAD PrevaLED Cube AC __ Logistical Data Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4052899150874 PL-CUBE-AC -1100-830G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1398.00 g 4052899150898 PL-CUBE-AC -1100-840G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1626.00 g 4052899909496 PL-CUBE-AC -2000-830G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1398.00 g 4052899909502 PL-CUBE-AC -2000-840G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1398.00 g 4052899909557 PL-CUBE-AC -3000-830G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1458.00 g 4052899909564 PL-CUBE-AC -3000-840G2 Shipping carton box 20 481 mm x 393 mm x 51 mm 9.64 dm³ 1458.00 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Accessories Optional Product description Accessory name Accessory code PL-CUBE-AC -1100-830-G2 PrevaLED Cube, -ADP 4052899055605 June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 8 of 9 Product family datasheet PL-CUBE-AC -1100-840-G2 PrevaLED Cube, -ADP 4052899055605 PL-CUBE-AC -2000-830-G2 PrevaLED Cube, -ADP 4052899055605 PL-CUBE-AC -2000-840-G2 PrevaLED Cube, -ADP 4052899055605 PL-CUBE-AC -3000-830-G2 PrevaLED Cube, -ADP 4052899055605 PL-CUBE-AC -3000-840-G2 PrevaLED Cube, -ADP 4052899055605 References / Links For more information on the multi-level guarantee and the terms and conditions of the guarantee visit www.osram.com/system-guarantee Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. __ June 15, 2016, 14:47:01 PrevaLED Cube AC G2 © 2016, OSRAM GmbH. All rights reserved. Page 9 of 9