Family data sheet

Product family datasheet
PrevaLED Cube AC G2
Spot-, Down- and Wallmount Light Engines and Modules
Areas of application
_ Suitable for diffuser and reflector luminaires
_ Hospitality, hotels, restaurants
_ Public and commercial buildings
_ Offices
_ Secondary rooms, garages, storerooms, cellars
__
Product benefits
_ Enables low-cost and compact luminaire designs
_ Low profile
_ Future-proof dimensions for reliable designs
_ Near Lambertian light distribution at 110° beam angle for high quality of light
_ Protection against overheating due to thermal derating
Product features
_ Mains voltage driven LED engine
_ Integrated control gear
_ Diameter of light emitting surface: 61 mm
_ Common mechanic and photometric interfaces
_ Initial color consistency: < 3 SDCM
_ Lifetime (L70/B50): 50,000 h (temperature at t point < 80 °C) acc. to IEC/PAS 62717
_ Temperature at t point (according to IEC/PASc62717): 70 °C
p
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 9
Product family datasheet
Technical data
Electrical data
Product description
Nominal
wattage
Rated
wattage
Nominal
voltage
Input voltage
range
Power factor λ
Type of
current
PL-CUBE-AC -1100-830-G2
12.0 W
12.50 W
230 V
220…240 V
> 0.90
AC
PL-CUBE-AC -1100-840-G2
12.0 W
11.30 W
230 V
220…240 V
> 0.90
AC
PL-CUBE-AC -2000-830-G2
27.8 W
27.80 W
230 V
220…240 V
> 0.90
AC
PL-CUBE-AC -2000-840-G2
25.3 W
25.30 W
230 V
220…240 V
> 0.90
AC
PL-CUBE-AC -3000-830-G2
42.7 W
37.60 W
230 V
220…240 V
> 0.90
AC
PL-CUBE-AC -3000-840-G2
38.4 W
33.80 W
230 V
220…240 V
> 0.90
AC
Product description
Total
useful
luminous
flux
Luminous
efficacy
Color
temperature
Color
rendering index
Ra
Standard
deviation of
color
matching
Rated peak
intensity
PL-CUBE-AC -1100-830-G2
1100 lm
90 lm/W
3000 K
82
≤3 sdcm
410 cd
PL-CUBE-AC -1100-840-G2
1100 lm
94 lm/W
4000 K
82
≤3 sdcm
410 cd
PL-CUBE-AC -2000-830-G2
2000 lm
72 lm/W
3000 K
≤3 sdcm
740 cd
PL-CUBE-AC -2000-840-G2
2000 lm
80 lm/W
3000 K
≤3 sdcm
740 cd
PL-CUBE-AC -3000-830-G2
3000 lm
71 lm/W
3000 K
83
≤3 sdcm
1110 cd
PL-CUBE-AC -3000-840-G2
3000 lm
79 lm/W
4000 K
83
≤3 sdcm
1110 cd
Product description
Nom.
useful
luminous
flux 120°
Rated
useful
luminous
flux 120°
PL-CUBE-AC -1100-830-G2
880 lm
880 lm
PL-CUBE-AC -1100-840-G2
880 lm
880 lm
PL-CUBE-AC -2000-830-G2
1600 lm
1600 lm
PL-CUBE-AC -2000-840-G2
1600 lm
1600 lm
PL-CUBE-AC -3000-830-G2
2400 lm
2400 lm
PL-CUBE-AC -3000-840-G2
2400 lm
2400 lm
Photometrical data
__
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 9
Product family datasheet
Light technical data
Product description
Nominal
beam
angle
Rated
beam
angle
(half peak
value)
Starting
time
Warm-up
time (60 %)
PL-CUBE-AC -1100-830-G2
110 °
110.00 °
< 0.5 s
< 0.50 s
PL-CUBE-AC -1100-840-G2
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -2000-830-G2
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -2000-840-G2
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -3000-830-G2
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -3000-840-G2
110 °
110.00 °
< 0.5 s
< 2.00 s
Dimensions & weight
__
Product description
Rated width
Construction
length
Rated height
Product
weight
PL-CUBE-AC -1100-830-G2
82.0 mm
83.0 mm
21.00 mm
55.00 g
PL-CUBE-AC -1100-840-G2
82.0 mm
83.0 mm
21.00 mm
55.00 g
PL-CUBE-AC -2000-830-G2
82.0 mm
83.0 mm
21.00 mm
55.00 g
PL-CUBE-AC -2000-840-G2
82.0 mm
83.0 mm
21.00 mm
55.00 g
PL-CUBE-AC -3000-830-G2
82.0 mm
83.0 mm
21.00 mm
61.00 g
PL-CUBE-AC -3000-840-G2
82.0 mm
83.0 mm
21.00 mm
61.00 g
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 9
Product family datasheet
Product line drawing
__
PL-CUBE-AC -1100-830-G2, PL-CUBE-AC -1100-840-G2, PLCUBE-AC -2000-830-G2, PL-CUBE-AC -2000-840-G2, PLCUBE-AC -3000-830-G2, PL-CUBE-AC -3000-840-G2
Temperatures & operating conditions
Product description
Maximum
temperature at tc
test point
Ambient
temperature range
PL-CUBE-AC -1100-830-G2
85 °C 1)
-20…+50 °C
PL-CUBE-AC -1100-840-G2
85 °C 1)
-20…+50 °C
PL-CUBE-AC -2000-830-G2
85 °C
1)
-20…+50 °C
PL-CUBE-AC -2000-840-G2
85 °C 1)
-20…+50 °C
PL-CUBE-AC -3000-830-G2
85 °C
1)
-20…+50 °C
PL-CUBE-AC -3000-840-G2
85 °C 1)
-20…+50 °C
1) Maximum at the Tc-point
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 9
Product family datasheet
Lifespan
Product description
Lumen main.
fact. at end of
nom. life time
Lifespan
Nominal lamp
life time
Rated lamp life
time
Number of switching
cycles
PL-CUBE-AC -1100-830-G2
0.70
50000 h 1)
50000 h
50000 h
25000
0.70
50000 h
1)
PL-CUBE-AC -1100-840-G2
PL-CUBE-AC -2000-830-G2
50000 h
50000 h
25000
0.70
50000 h 1)
50000 h
50000 h
25000
PL-CUBE-AC -2000-840-G2
0.70
50000 h
1)
50000 h
50000 h
25000
PL-CUBE-AC -3000-830-G2
0.70
50000 h 1)
50000 h
50000 h
25000
0.70
1)
50000 h
50000 h
25000
PL-CUBE-AC -3000-840-G2
50000 h
1) L70/B50 at Tc 70 °C
Capabilities
Product description
Dimmable
PL-CUBE-AC -1100-830-G2
No
PL-CUBE-AC -1100-840-G2
No
PL-CUBE-AC -2000-830-G2
No
PL-CUBE-AC -2000-840-G2
No
PL-CUBE-AC -3000-830-G2
No
PL-CUBE-AC -3000-840-G2
No
__
Certificates & standards
Product description
Energy
consumption
Standards
PL-CUBE-AC -1100-830-G2
13 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471
PL-CUBE-AC -1100-840-G2
12 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471
PL-CUBE-AC -2000-830-G2
22 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE
PL-CUBE-AC -2000-840-G2
21 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE
PL-CUBE-AC -3000-830-G2
38 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE
PL-CUBE-AC -3000-840-G2
35 kWh/1000h
CE/Acc. to EN 62031/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN
61000-3-3/Acc. to EN 61547/Acc. to IEC 62471/Acc. to VDE
Product description
Energy
efficiency
class
PL-CUBE-AC -1100-830-G2
A+
PL-CUBE-AC -1100-840-G2
A+
PL-CUBE-AC -2000-830-G2
A+
PL-CUBE-AC -2000-840-G2
A+
PL-CUBE-AC -3000-830-G2
A
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 9
Product family datasheet
Product description
Energy
efficiency
class
PL-CUBE-AC -3000-840-G2
A
Logistical data
Product description
Temperature
range at
storage
PL-CUBE-AC -1100-830-G2
-20…85 °C
PL-CUBE-AC -1100-840-G2
-20…85 °C
PL-CUBE-AC -2000-830-G2
-20…85 °C
PL-CUBE-AC -2000-840-G2
-20…85 °C
PL-CUBE-AC -3000-830-G2
-20…85 °C
PL-CUBE-AC -3000-840-G2
-20…85 °C
Light Distribution
__
PL-CUBE-AC -1100-830-G2, PL-CUBE-AC -2000-830-G2, PLCUBE-AC -3000-830-G2
PL-CUBE-AC -1100-840-G2, PL-CUBE-AC -2000-840-G2,
PL-CUBE-AC -3000-840-G2
Application advice
For more detailed application information and graphics please see product datasheet.
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 9
Product family datasheet
Additional product information
_ Installation by qualified electrician only.
_ Please see the relevant application guides and instructions sheets for more detailed safety and mounting information.
Additional information is available on request.
_ The module / light engine has to be mounted to a proper heat sink in order to ensure that the maximum rated temperature at
the T point will not be exceeded.
c
_ For safety
reasons the LED light engine must not be operated if the housing is damaged.
_ Complies with IEC/EN 62031
_ Complies with IEC/EN 61547
_ Complies with IEC/EN 61000-3-2
_ Complies with EN 55015, CISPR 15
_ Complies with IEC/EN 62717
_ Suitable only for operation with line voltage.
_ Parallel connection is mandatory for safe electrical operation. Serial connection of LED modules is stronly discouraged.
Unbalanced voltage drop in serial connection can cause hazardous overload and damage the LED module.
_ Conducting paths on the circuit board must not be damaged or destroyed during installation.
_ Suitable for luminaires of protection class I, grounding is mandatory to comply with safety standards.
_ When used in a luminaire of protection class II compliance with the required safety standards has to be ensured by the
luminaire manufacturer.
_ This LED module is not recommended to be used in rooms with fast moving parts as the light modulation can cause
stroboscopic effects.
_ This LED module might interfere with displays and cameras due to modulation.
_ The LED module itself and all its components must not be stressed mechanically.
_ For optimal cooling a thermal interface material should be applied between LED module and heat sink.
_ It is highly recommended to use a thermal interface material (TIM). The TIM needs to enable adequate heat transfer, during
__
installation it has to be taken care not to create air inclusions between surfaces. For this purpose it is recommended to use a
heat sink with even and clean surfaces.
_ The module must not be attached to wood or other flammable materials.
_ Protect against splashes!
_ The module, as manufactured, has no inherent protection against corrosion. It is the user's responsibility to provide suitable
protection against corrosive agents, such as moisture, condensation and other harmful elements.
Sales and Technical Support
Sales and Technical Support www.osram.com
Download Data
File
Product Family Datasheet
Family Datasheet: PrevaLED Cube AC G2
Brochures
Technical application guide PrevaLED Cube AC (GB)
Certificates
ENEC Marks Approval 40038544
Certificates
IEC Test Certificate CB54256_6281701_6281701_0001.
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 7 of 9
Product family datasheet
Declarations of conformity
EC-DoC PL-CUBE-AC-x000-8xx-230V-G2
CAD data
CAD PrevaLED Cube AC
CAD data 3-dim
CAD-Datei STEP: PrevaLED Cube AC G2
CAD data 3-dim
CAD-Data Parasolid: PrevaLED Cube AC G2
CAD data 3-dim
CAD-Datei IGES: PrevaLED Cube AC G2
CAD data PDF
CAD PrevaLED Cube AC 3D
CAD data PDF
CAD-Data 3D-PDF: PrevaLED Cube AC G2
Eulumdat
EULUMDAT: PrevaLED Cube AC G2
CAD data
CAD PrevaLED Cube AC Parasolid
CAD data
CAD PrevaLED Cube AC
__
Logistical Data
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4052899150874
PL-CUBE-AC -1100-830G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1398.00 g
4052899150898
PL-CUBE-AC -1100-840G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1626.00 g
4052899909496
PL-CUBE-AC -2000-830G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1398.00 g
4052899909502
PL-CUBE-AC -2000-840G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1398.00 g
4052899909557
PL-CUBE-AC -3000-830G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1458.00 g
4052899909564
PL-CUBE-AC -3000-840G2
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1458.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Accessories Optional
Product description
Accessory name
Accessory code
PL-CUBE-AC -1100-830-G2
PrevaLED Cube, -ADP
4052899055605
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 8 of 9
Product family datasheet
PL-CUBE-AC -1100-840-G2
PrevaLED Cube, -ADP
4052899055605
PL-CUBE-AC -2000-830-G2
PrevaLED Cube, -ADP
4052899055605
PL-CUBE-AC -2000-840-G2
PrevaLED Cube, -ADP
4052899055605
PL-CUBE-AC -3000-830-G2
PrevaLED Cube, -ADP
4052899055605
PL-CUBE-AC -3000-840-G2
PrevaLED Cube, -ADP
4052899055605
References / Links
For more information on the multi-level guarantee and the terms and conditions of the guarantee visit
www.osram.com/system-guarantee
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 15, 2016, 14:47:01
PrevaLED Cube AC G2
© 2016, OSRAM GmbH. All rights reserved.
Page 9 of 9