Family data sheet

Product family datasheet
PrevaLED Cube AC DALI
Spot-, Down- and Wallmount Light Engines and Modules
Areas of application
_ Hospitality, hotels, restaurants
_ Public and commercial buildings
_ Offices
_ Corridors
_ Shops
_ Secondary rooms, garages, storerooms, cellars
__
Product benefits
_ Easy dimming installations due to Touch DIM and corridor function
_ Easy connection to AC mains power and DALI interface
_ Enables low-cost and compact luminaire designs
_ Low profile
_ Future-proof dimensions for reliable designs
_ Near Lambertian light distribution at 110° beam angle for high quality of light
_ Protection against overheating due to thermal derating
Product features
_ Dimming range (DALI): 1…100 %
_ Dimensions of DALI version identical to on/off version
_ Mains voltage driven LED engine
_ Integrated control gear
_ Diameter of light emitting surface: 61 mm
_ Common mechanic and photometric interfaces
_ Initial color consistency: < 3 SDCM
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 8
Product family datasheet
_ Lifetime (L70/B50): 50,000 h (temperature at T = 70 °C)
c
__
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 8
Product family datasheet
Technical data
Electrical data
Product description
Nominal
wattage
Rated
wattage
Nominal
voltage
Power factor λ
Type of
current
PL-CUBE-AC -1100-830-G3 DALI
11.60 W
11.60 W
230 V
> 0.90
AC
PL-CUBE-AC -1100-840-G3 DALI
11.60 W
11.60 W
230 V
> 0.90
AC
PL-CUBE-AC -2000-830-G3 DALI
19.20 W
19.20 W
230 V
> 0.90
AC
PL-CUBE-AC -2000-840-G3 DALI
19.20 W
19.20 W
230 V
> 0.90
AC
PL-CUBE-AC -3000-830-G3 DALI
30.70 W
30.70 W
230 V
> 0.90
AC
PL-CUBE-AC -3000-840-G3 DALI
30.70 W
30.70 W
230 V
> 0.90
AC
Product description
Total
useful
luminous
flux
Luminous
efficacy
Color
temperature
Color
rendering index
Ra
Standard
deviation of
color
matching
Rated peak
intensity
PL-CUBE-AC -1100-830-G3 DALI
1100 lm
95 lm/W
3000 K
>80
≤3 sdcm
403 cd
PL-CUBE-AC -1100-840-G3 DALI
1100 lm
95 lm/W
4000 K
>80
≤3 sdcm
403 cd
PL-CUBE-AC -2000-830-G3 DALI
2000 lm
104 lm/W
3000 K
>80
≤3 sdcm
732 cd
PL-CUBE-AC -2000-840-G3 DALI
2000 lm
104 lm/W
4000 K
>80
≤3 sdcm
732 cd
PL-CUBE-AC -3000-830-G3 DALI
3000 lm
98 lm/W
3000 K
>80
≤3 sdcm
1098 cd
PL-CUBE-AC -3000-840-G3 DALI
3000 lm
98 lm/W
4000 K
>80
≤3 sdcm
1098 cd
Product description
Nom.
useful
luminous
flux 120°
Rated
useful
luminous
flux 120°
PL-CUBE-AC -1100-830-G3 DALI
879 lm
879 lm
PL-CUBE-AC -1100-840-G3 DALI
879 lm
879 lm
PL-CUBE-AC -2000-830-G3 DALI
1598 lm
1598 lm
PL-CUBE-AC -2000-840-G3 DALI
1598 lm
1598 lm
PL-CUBE-AC -3000-830-G3 DALI
2397 lm
2397 lm
PL-CUBE-AC -3000-840-G3 DALI
2397 lm
2397 lm
Photometrical data
__
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 8
Product family datasheet
Light technical data
Product description
Nominal
beam
angle
Rated
beam
angle
(half peak
value)
Starting
time
Warm-up
time (60 %)
PL-CUBE-AC -1100-830-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -1100-840-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -2000-830-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -2000-840-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -3000-830-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
PL-CUBE-AC -3000-840-G3 DALI
110 °
110.00 °
< 0.5 s
< 2.00 s
Dimensions & weight
__
Product description
Rated width
Construction
length
Rated height
Product
weight
PL-CUBE-AC -1100-830-G3 DALI
81.6 mm 1)
82.8 mm 1)
21.20 mm 1)
66.00 g
PL-CUBE-AC -1100-840-G3 DALI
81.6 mm
1)
82.8 mm
1)
21.20 mm
1)
66.00 g
PL-CUBE-AC -2000-830-G3 DALI
81.6 mm
1)
82.8 mm
1)
21.20 mm
1)
66.00 g
PL-CUBE-AC -2000-840-G3 DALI
81.6 mm 1)
82.8 mm 1)
21.20 mm 1)
66.00 g
PL-CUBE-AC -3000-830-G3 DALI
81.6 mm
1)
1)
1)
66.00 g
PL-CUBE-AC -3000-840-G3 DALI
81.6 mm 1)
21.20 mm 1)
66.00 g
82.8 mm
82.8 mm 1)
21.20 mm
1) general tolerances ISO 2768-c
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 8
Product family datasheet
Product line drawing
__
PL-CUBE-AC -1100-830-G3 DALI, PL-CUBE-AC -1100-840G3 DALI, PL-CUBE-AC -2000-830-G3 DALI, PL-CUBE-AC 2000-840-G3 DALI, PL-CUBE-AC -3000-830-G3 DALI, PLCUBE-AC -3000-840-G3 DALI
Temperatures & operating conditions
Product description
Performance temp. acc. to
IEC 62717
Maximum
temperature at tc
test point
Ambient
temperature range
PL-CUBE-AC -1100-830-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
PL-CUBE-AC -1100-840-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
PL-CUBE-AC -2000-830-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
PL-CUBE-AC -2000-840-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
PL-CUBE-AC -3000-830-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
PL-CUBE-AC -3000-840-G3 DALI
70 °C
90 °C
-20…+50 °C 1)
1) T (rated) = 25 °C
a
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 8
Product family datasheet
Lifespan
Product description
Lifespan
Nominal lamp
life time
Rated lamp life
time
Number of switching
cycles
PL-CUBE-AC -1100-830-G3 DALI
50000 h
50000 h
50000 h
100000
PL-CUBE-AC -1100-840-G3 DALI
50000 h
50000 h
50000 h
100000
PL-CUBE-AC -2000-830-G3 DALI
50000 h
50000 h
50000 h
100000
PL-CUBE-AC -2000-840-G3 DALI
50000 h
50000 h
50000 h
100000
PL-CUBE-AC -3000-830-G3 DALI
50000 h
50000 h
50000 h
100000
PL-CUBE-AC -3000-840-G3 DALI
50000 h
50000 h
50000 h
100000
Product description
Dimmable
Dimming interface
Dimming range
PL-CUBE-AC -1100-830-G3 DALI
Yes
DALI
1…100 %
PL-CUBE-AC -1100-840-G3 DALI
Yes
DALI
1…100 %
PL-CUBE-AC -2000-830-G3 DALI
Yes
DALI
1…100 %
PL-CUBE-AC -2000-840-G3 DALI
Yes
DALI
1…100 %
PL-CUBE-AC -3000-830-G3 DALI
Yes
DALI
1…100 %
PL-CUBE-AC -3000-840-G3 DALI
Yes
DALI
1…100 %
Capabilities
Certificates & standards
__
Product description
Energy
consumption
Energy
efficiency
class
PL-CUBE-AC -1100-830-G3 DALI
11 kWh/1000h
A+
PL-CUBE-AC -1100-840-G3 DALI
10 kWh/1000h
A+
PL-CUBE-AC -2000-830-G3 DALI
17 kWh/1000h
A+
PL-CUBE-AC -2000-840-G3 DALI
17 kWh/1000h
A+
PL-CUBE-AC -3000-830-G3 DALI
26 kWh/1000h
A
PL-CUBE-AC -3000-840-G3 DALI
26 kWh/1000h
A
Application advice
For more detailed application information and graphics please see product datasheet.
Additional product information
_ Installation by qualified electrician only.
_ Please see the relevant application guides and instructions sheets for more detailed safety and mounting information.
Additional information is available on request.
_ The module / light engine has to be mounted to a proper heat sink in order to ensure that the maximum rated temperature at
the T point will not be exceeded.
c
_ For safety
reasons the LED light engine must not be operated if the housing is damaged.
_ Complies with IEC/EN 62031
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 8
Product family datasheet
_ Complies with IEC/EN 61547
_ Complies with IEC/EN 61000-3-2
_ Complies with EN 55015, CISPR 15
_ Complies with IEC/EN 62717
_ Suitable only for operation with line voltage.
_ Parallel connection is mandatory for safe electrical operation. Serial connection of LED modules is stronly discouraged.
Unbalanced voltage drop in serial connection can cause hazardous overload and damage the LED module.
_ Conducting paths on the circuit board must not be damaged or destroyed during installation.
_ Suitable for luminaires of protection class I, grounding is mandatory to comply with safety standards.
_ When used in a luminaire of protection class II compliance with the required safety standards has to be ensured by the
luminaire manufacturer.
_ This LED module is not recommended to be used in rooms with fast moving parts as the light modulation can cause
stroboscopic effects.
_ This LED module might interfere with displays and cameras due to modulation.
_ The LED module itself and all its components must not be stressed mechanically.
_ For optimal cooling a thermal interface material should be applied between LED module and heat sink.
_ It is highly recommended to use a thermal interface material (TIM). The TIM needs to enable adequate heat transfer, during
installation it has to be taken care not to create air inclusions between surfaces. For this purpose it is recommended to use a
heat sink with even and clean surfaces.
_ The module must not be attached to wood or other flammable materials.
_ Protect against splashes!
_ The module, as manufactured, has no inherent protection against corrosion. It is the user's responsibility to provide suitable
protection against corrosive agents, such as moisture, condensation and other harmful elements.
Sales and Technical Support
__
Sales and Technical Support www.osram.com
Download Data
File
Brochures
Technical application guide PrevaLED Cube AC DALI light engines (GB)
Declarations of conformity
EC Declaration of Conformity: PL Cube AC G3 DA
CAD data
CAD Datei IGES: PL Cube AC DALI G3
CAD data
CAD Daten STEP: PL Cube AC DALI G3
CAD data
CAD Datei Parasolid: PL Cube AC DALI G3
CAD data 3-dim
CAD Data 3D PDF: PL CUBE AC DALI G3
Logistical Data
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 7 of 8
Product family datasheet
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4052899318106
PL-CUBE-AC -1100-830G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1917.00 g
4052899318199
PL-CUBE-AC -1100-840G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1598.00 g
4052899318069
PL-CUBE-AC -2000-830G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1598.00 g
4052899318083
PL-CUBE-AC -2000-840G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1598.00 g
4052899318120
PL-CUBE-AC -3000-830G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1598.00 g
4052899318151
PL-CUBE-AC -3000-840G3 DALI
Shipping carton box
20
481 mm x 393 mm x 51 mm
9.64 dm³
1598.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
References / Links
For more information on the multi-level guarantee and the terms and conditions of the guarantee visit
www.osram.com/system-guarantee
__
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
June 4, 2016, 07:26:38
PrevaLED Cube AC DALI
© 2016, OSRAM GmbH. All rights reserved.
Page 8 of 8