Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA Features Wide 2 : 1 Input Voltage Range(9~18V,18~36V,36~75V) Remote On/Off Over Voltage Protection: Clamp Mode Shielded Metal Case with Insulated Baseplate Lead Free Design, RoHS Compliant 6 pin DIP Package with Industry-Standard Footprint Customer Design Available Safety Standard / Approval : IEC / EN 60950-1 Input / Output Isolation Voltage: 3kVDC Extended Operating Temperature Range: -40°C to+85°C Output Short Circuit Protection: Continuous & Auto Recovery Description The HUB10H3 Series are isolated 10W DC/DC converters. Designed with highly efficiency, allow the operating temperature range of these units to be -40°C to +85°C in a 6 pin DIP package with industry-standard footprint. Further features include wide 2 : 1 input voltage range, remote on/off control, short-circuit protection, over voltage protection and high Input / Output isolation ( 3000VDC ). Applications These converters are well suitable for battery operated equipment, measurement equipment, telecom, wireless network, Industry control system, everywhere where isolated, tightly regulated voltages and compact size are required. Technical Specification Model Number All specifications are typical at nominal input, full load and 25°C unless otherwise stated. Output (2) Capacitive Output Current (mA) Input Current (mA) Input Voltage Eff . Voltage Load, max. (1) Range (%) (3) Min. Load Full. Load No Load Full Load (V) (uF) HUB10-12S0H3 3.3 20 3000 10 1130 77 3300 HUB10-12S1H3 5 0 2000 21 1069 82 1330 HUB10-12S2H3 12 0 830 22 1013 86 680 9~18V Nominal:12V HUB10-12S5H3 15 0 670 21 1034 85 470 24 0 415 24 1000 87 133 HUB10-12D1H3 ±5 0 ±1000 20 1069 82 1000 HUB10-12D2H3 ±12 0 ±415 28 1013 86 220 HUB10-12D3H3 ±15 0 ±330 30 1019 85 147 HUB10-24S0H3 3.3 20 3000 6 558 78 3300 HUB10-24S1H3 5 0 2000 10 528 83 1330 HUB10-24S2H3 12 0 830 12 506 86 680 18~36V Nominal:24V HUB10-24S5H3 15 0 670 12 517 85 470 24 0 415 13 500 87 147 HUB10-24D1H3 ±5 0 ±1000 10 528 83 1000 HUB10-24D2H3 ±12 0 ±415 15 506 86 220 HUB10-12S3H3 HUB10-24S3H3 HUB10-24D3H3 ±15 0 ±330 17 510 85 147 HUB10-48S0H3 3.3 20 3000 3 279 78 3300 HUB10-48S1H3 5 0 2000 6 264 83 1330 HUB10-48S2H3 12 0 830 7 253 86 470 36~75V Nominal:48V HUB10-48S5H3 15 0 670 6 262 84 220 24 0 415 8 257 85 100 HUB10-48D1H3 ±5 0 ±1000 6 261 84 680 HUB10-48D2H3 ±12 0 ±415 8 253 86 122 HUB10-48D3H3 ±15 0 ±330 9 258 84 100 HUB10-48S3H3 [email protected] www.bothhandusa.com Rev:20130814A Page 1 of 7 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA Input Specifications Input Voltage 12V nominal input 9-18V 24V nominal input 18-36V 48V nominal input 36-75V Input filter Pi Type Input surge voltage 12V nominal input 25V (100ms max.) 24V nominal input 50V 48V nominal input 100V 170mAp-p max. Input reflected ripple current Nominal Vin and full load Start up time Nominal Vin and constant resistive load Remote ON/OFF 770ms typ. Converter: ON Open or 3.5V<Vr<12V Converter: OFF Short (4) or 0V<Vr<1.2V Sourcing current of remote control pin Nominal Vin <0.2 mA Idle input current (at Remote OFF state) Nominal Vin <3 mA Environmental Specifications -40°C to +85°C (with derating) Operating ambient temperature +100°C Maximum case temperature -55°C to +105°C Storage temperature range 5% to 95% RH Relative humidity ±0.02% / °C max. Temperature coefficient Output Specifications 10 Watts max. Output power Voltage accuracy Full load and nominal Vin ±1% See table Minimum load Line regulation LL to HL at full load 25% load to full load Load Regulation Balanced load ±0.5% Single ±0.5% Dual ±0.5% Unbalanced load 25% to 100% full load Ripple and Noise ±5% 100mVp-p max. 20MHz bandwidth 3.3Vout models 3.9V Over voltage protection 5Vout models 6.2V (Zener Diode Clamp) 12Vout models 15V 15Vout models 18V 24Vout models 27V See table Capacitive load Over load protection % of full load at nominal input Continuous, automatic recovery Short circuit protection Transient response settling time 50% load step change Transient response over shoot di/dt=0.8A/µs [email protected] 150% typ. www.bothhandusa.com 2000µs typ. ≤ ±5% of Vo Rev:20130814A Page 2 of 7 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA General Specifications Efficiency Nominal input Isolation voltage Input to output Isolation resistance See table 3000VDC 9 500VDC 10 Ohms min. Isolation capacitance 500pF typ. Switching frequency 300kHz typ. 6 Reliability, calculated MTBF 1.96× 10 Hrs Physical Specifications Case material Nickel-coated copper Base material Non-conductive black plastic Silicon rubber (UL94V-0) Potting material 2.0 × 1.0 × 0.4 Inch Dimensions (50.8 × 25.4 × 10.2 mm) Weight 30g (1.06oz) typ. HUB10H3 Series (5) Output Power (%) Power Derating Curve Ambient Temp.TA (℃) HUB10-48S1H3 HUB10-48S1H3 Output Current vs. Efficiency 90 90 85 80 Efficiency % Efficiency (%) Efficiency (%) Efficiency % Input voltage vs. Efficiency 75 70 65 60 55 50 85 80 75 70 65 60 55 50 Input voltage (V) [email protected] Output Current (A) www.bothhandusa.com Rev:20130814A Page 3 of 7 2 75 1.8 68 1.6 64 1.4 60 1.2 56 1 52 0.8 48 0.6 44 0.4 40 0.2 36 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA HUB10-48S1H3 HUB10-48S1H3 Transient Response at 50%~100% Max Load Loop Gain & Phase at Vi=48V,Full Load Note 1. Io below this value will not damage these converters, however, they may not meet all listed specifications. 2. Typical value, tested at nominal input and full load. 3. For each output. 4. Short to -Vin (Pin 2). 5. Based on HUB10-48S1H3. Mechanical Dimensions Pin 1 2 3 4 5 6 Pin Assignment Single Dual +Vin +Vin -Vin -Vin +Vout +Vout Trim Common -Vout -Vout Remote On/Off (optional) Unit: mm [inch] Tolerance:±0.5[0.02] Specifications subject to change without noticed. [email protected] www.bothhandusa.com Rev:20130814A Page 4 of 7 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA Test Configurations All specifications are typical at nominal input, full load and 25°C unless otherwise stated. A A DC Power Supply DC/DC converter V V Load ◎DC Power Supply: It offers a wide voltage and current range precisely. ◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits) 2000mA ~ 20A 2 ranges+(0.3% rdg + 2 digits). ◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits). ◎Load: At full load. ◎Wires: The resistance of the wires must be small. 1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range (2:1 and 4:1)。 EX: Narrow input voltage range(±10%) 5V nominal input 4.5~5.5V 12V nominal input 10.8~13.2V 24V nominal input 21.6~26.4V Wide input voltage range 2:1 5V nominal input 12V nominal input 24V nominal input 48V nominal input 4.5~9V 9~18V 18~36V 36~75V Wide input voltage range 4:1 (W) 24V nominal input 9~36V 48V nominal input 18~75V 2. Input power : Pin = Vin x Iin Vin:Input voltage Iin:Input current Pout = Vout x Iout Vout:Output voltage Iout:Output current 3. Output power : 4. Efficiency : Efficiency = Pout Pin x100% Pout: Output power Pin: Input power 5. Voltage accuracy: │ │Vout-Vout(nominal)│ Vout [email protected] x100% Vout:Output voltage Vout(nominal):Nominal output voltage www.bothhandusa.com Rev:20130814A Page 5 of 7 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA ││││ ││││ 6. Line regulation: (1) Wide input voltage range and regulated output voltage series. │Vout(LL)-Vout(HL)│ │ Vout(LL) LL: Low Line input voltage HL: High Line input voltage x100% (2) Narrow input voltage range(±10%)and unregulated output voltage series. Line regulation= Δ Vout Δ Vin ΔVout = Vout(+10%)-Vout(-10%) x100% Vout Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load Vout:Output voltage at Vin = Vin(nominal)&full load ΔVin = Vin(+10%)-Vin(-10%) x100% Vin(nominal) Vin(+10%):Input voltage = 1.1xVin(nominal) Vin(-10%):Input voltage = 0.9xVin(nominal) Vin(nominal):Nominal Input voltage 7. Load regulation : │ x100% │Vout(FL)-Vout(NL)│ Vout(FL) Vout(FL): Output voltage at full load Vout(NL): Output voltage at 25% full load or 10% full load 8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz. Ripple&Noise Noise Ripple [email protected] www.bothhandusa.com Rev:20130814A Page 6 of 7 Isolated DC-DC Converters HUB10H3 Series -- 10Watt Bothhand USA Output Ripple&Noise measurement test circuit: as shown below. Copper strip DC/DC converter Co Oscilloscope Load Copper strip Co: usually 0.47uF. 9. Temperature derating curve: The DC-DC converter will operate over a wider temperature range if less power is Output Power (%) drawn from the output and the device is already running. The temperature derating curve shows the operating power-temperature range. As shown below. Ambient Temp.TA (℃) 10. Switching frequency: The nominal operating frequency of the DC-DC converters. 11. Input to output isolation: The dielectric breakdown strength test between input and output circuits. This is the isolation voltage the device is capable of withstanding for a specified time, usually 1 second or 1 minute. [email protected] www.bothhandusa.com Rev:20130814A Page 7 of 7