MA-COM TR250-080U

Tyco/Electronics
PolySwitch®
PTC Devices
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
Fax: 800-227-4866
PRODUCT: TR250-080U
DOCUMENT: SCD 23431
PCN: 856313
REV LETTER: E
REV DATE: NOVEMBER 14, 2001
PAGE NO.: 1 OF 1
Overcurrent Protection Device
Specification Status: RELEASED
Max Electrical Rating at 20°°C
Operating Voltage: 60VDC
Fault Voltage: 250VRMS
Interrupt Current: 3ARMS
Lead Material : 22 AWG Sn/Pb plated
copper
Marking:
None
TABLE I. DIMENSIONS
A
mm:
in*:
Min
---
B
Max
4.8
(0.189)
Min
---
C
Max
9.30
(0.366)
Min
---
D
Max
3.8
(0.150)
Min
4.7
(0.185)
Max
---
E
Nom
5.0
(0.197)
TABLE II. PERFORMANCE RATINGS @ 20°°C (unless otherwise noted):
IHOLD (A)
20°C
0.080
RESISTANCE (Ω)
@ 20° C
R MIN
14.0
TIME TO TRIP
@ 0.35A
R MAX
20.0
R1 MAX*
Seconds, MAX
33.0
3
* Maximum device resistance at 20°C measured 1 hour post trip.
OPERATING
TEMPERATURE (°C)
MIN
-40
MAX
85
Additional Rating @ 20°C
Lightning Withstand:
Agency Recognition:
Reference Documents:
Precedence:
Effectivity:
CAUTION:
ITU @ 1.0KV
Storage Temperature:
-40 to 85° C
UL, CSA, TUV
PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.