POWER QUALITY ANALYZER 3197 Power Measuring Instruments T h e M o s t C o m p r e h e n s i ve Portable PQA on The Market Catch Power Quality Problems on the Fly... Monitor for: ✔ Inrush Current ✔ Voltage Swells ✔ Voltage Dips ✔ Transient Overvoltage ✔ Interruptions Measure and Record: ✔ Power and Power Factor ✔ Active/Reactive Energy ✔ Demand ✔ Load Changes (with graph display!) ✔ Voltage and Current ...Before They Catch You! Measure Power and Power Quality on Single to Three-Phase Circuits Quickly and Effortlessly P Q A Feature 1: Vector Multimeter Use the wiring map, vector map and data monitor to c he c k for p r op e r wiring before taking measurements – don’t miss out on important power data just because of minor wiring mistakes! 3197 A quick glance at the correct vector map will show you if your wiring is correct Feature 2: QuickSet With QuickSet, all you have to do is just Set, Clamp and Measure! Line frequency Measurement Interval Nominal Voltage Event Swell thresholds Dip against Interruption nominal Transient voltage : : : : : : Auto Auto Auto 110% 90% 10% : ON Let QuickSet help you take care of all the time-consuming setup procedures. All you need to do is select your circuit, clamp sensor and range, and then let QuickSet do the rest of the work for you. Testing Parameters Automatically Defined by QuickSet Redefine Thresholds Easily with Intuitive Key Panel Feature 3: Power & Power Quality Measure all the necessary power parameters simultaneously Get a crystal clear picture of the voltage fluctuation on all channels Check for sudden inrush during motor startup and diagnose breaker trips due to over current all on the same measurement interface. View RMS data for every half cycle over a 30 second period on a large graph display All items are recorded as events so that a quick understanding can be obtained just by viewing the waveform ✓ ✓ ✓ ✓ ✓ Power & Energy Voltage ✓ Demand Current ✓ Load Changes Frequency ✓ THD(voltage) Power Active/Reactive ✓ and Power Factor Energy Voltage Fluctuation (dips and swells) 2 ✓ ✓ ✓ ✓ ✓ Power Quality Inrush Current Voltage Swells Voltage Dips Transient Overvoltage Interruptions 1 Setting Up is as Easy as 1-2-3 Select your wiring 2 3 QuickSet Toggle between screens to customize your measurement settings RE C& EVE NT Make detailed settings on how and when to measure, and customize your level of event detection as desired. Select from 5 Types of Color-coded Input Terminal Labels to Suit Your Application Region U1 U2 U3 Red Yellow Blue Japan, U.K. Blue Orange Black Gray EU (new) 3 Black Yellow Green Red China 4 Blue Black Red White EU (former) 5 White Black Red Blue N. America Obtain real-time moving data on voltage, current, power, and more! Monitor Trends while Recording Region Black 2 E UR S A ME WAVEFORM N 1 Use the correct vector diagram to check that your wiring is right before measuring, particularly useful when measuring 3-Phase circuits WIRIN G Use QuickSet to automatically set the default values for line frequency, nominal voltage, interval, and power quality thresholds for event detection Type Select your clamp sensor Pull Strap Through for Ultimate Portability AC Adapter for Quick Recharge or Long Recordings Toggle between screens using VIEW key for instantaneous power data USB Port for PC Compatibility One-touch switching between graph and numerical data Power Switch RMS, Phase Angle and Lead and Lag Full-color waveforms and RMS readings Convenient Stand for Hands-free Viewing Rugged and Durable Casing to withstand even the toughest environments and uses 3 VECTOR Record and Inspect Auto-Data Compression Lets You Record for up to 125 Days Find the max, min and average values for any point using the cursor function (even while measuring) RMS DIP/SWELL Toggle between the trend graphs for a complete analysis of the power situation Get a detailed picture during voltage anomalies fluctuation range for all 3 channels are displayed ✓ Consumed & Regenerated Active Power ✓ Lag and Lead of Reactive Power ENERGY Demand Graph and maximum and average values displayed in one window DEMAND Display events AND their waveforms at the same time DMM Harmonic waveforms of voltage, current and active power to the 50th order Identify Power Quality Problems WAVEFORM Switch between voltage and current graphs, and zoom in on the time axis at the touch of a button Toggle between events for a complete picture of the power anomaly Store up to 50 Events RMS voltage fluctuations such as swells and dips are clearly displayed at event detection INRUSH HARMONICS "I" marks an Inrush Event GRAP/LIST DETAIL Inrush current fluctuations are captured in RMS at a fast 10ms sampling rate and displayed across a 30-second window Record up to 20 graphs in internal memory 4 Scroll down and select to display the finer details of any event RMS Feature 4: Bundled PC Application Software Mobility, Portability Plus Convenient Data Transfer Right to Your PC Two Integrated Programs for Data Download and Viewing Feature 5: Compact Design Makes for Long Battery Life St andard USB conne c tion let s you download dat a at a snap, and immediately view your measurements with the DataViewer 6 Hours of Continuous Use on a Single Recharge Non-volatile Ni-MH rechargeable battery pack keeps important measurement data in memory even after power is turned off. Connect to multiple 3197 units simultaneously using a USB hub A PQA that TRULY fits in the palm of your hand. Open downloaded recordings with DataViewer to manage and process your captured power data on your PC. Event List Event Details Time Plot Graph Standard 3197 Package Fulfills All the Requirements for Checking Voltage Anomalies Voltage Cords Carrying Case Rechargeable Battery Pack Event Waveform Settings nEvent Detection RMS Voltage and Current Voltage Accuracy Current Accuracy Voltage (1/2) RMS Measurement Accuracy Current (1/2) RMS Measurement Accuracy Frequency Accuracy Active Power Accuracy (for consumption and regeneration) Voltage Swells (Rise), Voltage Dips (Drop), Interruptions Inrush Current Transient Overvoltage ±0.3% rdg. ±0.2% f.s. + clamp-on sensor accuracy (P.F.=1) Reactive Power Accuracy ±1 dgt. of calculation from each measurement (for lags and leads) value Effect of Power Factor Apparent Power Accuracy Power Factor and Displacement Power Factor Accuracy (leading phase indicated) Active or Reactive Energy Consumption Accuracy Demand Accuracy Harmonic Analysis Orders Harmonic Voltage, Current and Power Accuracy (accuracy is not defined for harmonic power) Other Measurement Items ±1.0% rdg. (50 /60Hz, P.F.=0.5) ±1 dgt. of calculation from each measurement value ±1 dgt. of calculation from each measurement value (DPF calculated from phase difference between fundamental voltage and current waveforms) Selectable between consumption, regeneration, lag and lead ±1 dgt. applied to active and reactive power measurement accuracy Selectable between active or reactive power ±1 dgt. applied to active and reactive power measurement accuracy Up to 50th (2048 points/window, rectangular) 1st to 15th order ±0.5% rdg. ±0.2% f.s. 16th to 25th order ±1.0% rdg. ±0.3% f.s. 26th to 35th order ±2.0% rdg. ±0.3% f.s. 36th to 45th order ±3.0% rdg. ±0.3% f.s. 46th to 50th order ±4.0% rdg. ±0.3% f.s. (add accuracy of clamp sensor to harmonic current accuracy) Peak Voltage and Current, K Factor, Voltage Unbalance Factor, Max/Min/Ave of Time Series PC Application To measure current and power, please select one or more of our HIOKI Clamp On Sensors detailed on the back of this catalog. nMeasurement Specifications (Guaranteeed Accuracy Period: 1 Year) True RMS (200 ms calculation ) ±0.3% rdg. ±0.2%f.s ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy True RMS (one cycle calculation refreshed every half cycle) ±0.3% rdg. ±0.2%f.s. True RMS (half-cycle calculation, half-cycle voltage synchronized) ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy Effective Measurement range: 45.00 to 66.00 Hz ±0.01 Hz ±1 dgt. (when input is at least 10% of range) USB Cable AC Adapter Timer Detection Manual Detection Thresholds Event Recording Lengths Waveform Event voltage fluctuation graph Inrush current graph Maximum Number of Recordable Events RMS value detected using voltage (1/2) measured every half cycle RMS value detected using current (1/2) every half cycle Detection Range: 50 Vrms (±70.7 Vpeak equiv.) or more, 10 to 100 kHz Detect events at preset intervals selectable from OFF, 1, 5, 15 or 30 minutes; 1, 2 or 12 hours; or 1 day Detect events when keys are pressed Set to OFF or to specified value, except for detection of transient overvoltages. (Waveform recording not available for transients.) 20ms before detection + 200ms upon detection + 30ms after detection 0.5s before + 2.5s after detection 0.5s before + 29.5s after detection 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts nInput Specifications Single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire (3P3W2M and 3P3W3M), three-phase four-wire (3P4W and 3P4W2.5E) Measurement Line frequency Auto-select (50/60 Hz) Maximum Allowable Input Voltage input terminal: 780 V AC (1103 Vpeak) Current input terminal: 1.7 V AC (2.4 Vpeak) Voltage Maximum Rated Voltage Voltage input terminal: CATIII 600 V AC, CATIV 300 V AC (50/60 Hz) Current input terminal: per clamp-on sensors used to Ground Simultaneous digital sampling of voltage and current Measurement Method (sampling frequency: 10.24 kHz per channel) Voltage Measurement 600.0V (Crest factor 2 or less) Range Wiring Configurations Current Measurement Range: Manual ranging according to clamp sensor (Crest factor 3 or less) Clamp Sensor Range Clamp Sensor Range 9657-10, 9675 500.0 mA/5.000 A 9661, 9667 (500A) 50.00 A/500.0 A 9694, 9695-02 5.000 A/50.000 A 9669 100.0 A/1.000 kA 9660, 9695-03 10.00 A/100.0 A 9667 (5000A) 500.0 A/5.000 kA 500mA 300.0W/600.0W/900.0W 100A 60.00kW/120.0kW/180.0kW Power Measurement 5A 3.000kW/6.000kW/9.000kW 500A 300.0kW/600.0kW/900.0kW Range: Depends on combination of current range 10A 6.000kW/12.00kW/18.00kW 1kA 600.0kW/1.200MW/1.800MW and measurement line 50A 30.00kW/60.00kW/90.00kW 5kA 3.000MW/6.000MW/9.000MW 5 n BASIC SPECIFICATIONS n ENVIRONMENTAL AND SAFETY-RELATED SPECIFICATIONS Display Display languages Display refresh rate Clock functions Real-Time Clock accuracy Internal Memory Capacity Maximum recording time Operating environment Demand period 4.7-inch color STN LCD English, Japanese or Chinese (Simplified) Approx. once per second Auto calendar, auto leap year, 24-hour format Within 13 seconds/month 4MB 125 Days AUTO, 1, 5, 15 and 30 min., and 1 hour (AUTO sequentially selects 1, 2, 10, 30 seconds, 1, 5, 15 and 30 min., and 1 hour automatically) 15 min., 30 min. and 1 hour Recordable Items All parameters (incl. max/min/average values) Interval Settings n INTERFACE SPECIFICATIONS Interface Connection destination USB 2.0 (Full Speed) Computer operating on Windows 2000/XP Temperature and humidity Applicable standards Power source Indoors, up to 2000 m (6562-ft.) ASL -10 to 50°C (14 to 122°F), 80% RH or less (non-condensating) Storage Operation 0 to 40°C (32 to 104°F), 80% RH or less (non-condensating) EN61010, Pollution degree 2, Measurement Categories III (600 V) and IV (300 V) Safety (anticipated transient overvoltage 6000 V) EN61326 Class A EMC EN61000-3-2, EN61000-3-3 AC Adapter 9418-15 or Battery Pack 9459 (Maximum rated power: 23 VA (with AC adapter) Continuous Approx. 6 hours operating time (after full charge, with 5 min. auto-off LCD backlight) with battery pack 128 W × 246 H × 63 D mm (5.04”W × 9.69”H × 2.48”D) Dimensions and (including stand) mass Approx. 1.2 kg (42.3 oz.) (with battery pack) nCLAMP ON SENSOR SPECIFICATIONS 9694 9660 3m cord 3m cord 9661 9669 3m cord 9667 3m cord 9695-02 9695-03 CAT III 1000V MODEL CAT III 300V CAT III 300V Measurable conductor diameter Primary current rating Output voltage Accuracy CAT III 600V φ15mm AC 5A AC 10mV/A AC 100A AC 1mV/A 2m from sensor to circuit 1m from circuit to connector CAT III 600V φ46mm φ55mm, 80×20mm φ254mm AC 500A AC 1mV/A AC 1000A AC 0.5mV/A AC 500A/5000A AC 500mVf.s. CAT III 300V CAT III 300V φ15mm AC 50A AC 10mV/A AC 100A AC 1mV/A Amplitude ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.01%f.s. ±1.0%rdg.±0.01%f.s. ±2.0%rdg.±1.5mV ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s. (45 to 66 Hz) Phase within ±1° within ±2° within ±1° within ±0.5° within ±1° within ±2° within ±1° (5Hz to 5kHz) (minimum 10% input) Frequency characteristic (accuracy deviation) Max. rated voltage to earth(insulated conductor) within ±1.0% at 40Hz to 5kHz (9669: within ±2.0%) 300Vrms Maximum allowable 50A continuous input (45 to 66 Hz) Dimensions and weight 46W×135H×21Dmm, 230g Requirements ±3dB at 10Hz to 20kHz within ±1.0% at 40Hz to 5kHz 1000Vrms 300Vrms 300Vrms 600Vrms 600Vrms 130A continuous 550A continuous 1000A continuous 10000A continuous 46W×135H×21Dmm, 230g 77W×151H×42Dmm, 360g 100W×188H×42Dmm, 590g Sensor length 910mm, 140g 9445-02/03 AC Adapter (Option) CLAMP ON SENSOR (100A) CLAMP ON SENSOR (500A) FLEXIBLE CLAMP ON SENSOR (5000A) CLAMP ON SENSOR (1000A) CLAMP ON SENSOR (5A) CLAMP ON SENSOR (50A) CLAMP ON SENSOR (100A) CONNECTION CORD (for the 9695-02/9695-03) CLAMP ON LEAK SENSOR (10A) CLAMP ON LEAK SENSOR (10A) VOLTAGE CORD (bundled with the standard 3197) AC ADAPTER (bundled with the standard 3197) BATTERY PACK (bundled with the standard 3197) PQA-HiVIEW Pro PC Application Software 9660 9661 9667 9669 9694 9695-02 9695-03 9219 9657-10 9675 9438-05 9418-15 9459 9624-50 n3197 STANDARD BUNDLE CONFIGURATION Includes all the equipment you need to measure voltage. For current or power measurements, please select from our wide assortment of clamp on sensors. VOLTAGE CORD 9438 -05 (3m cord length), BATTERY PACK 9459, AC ADAPTER 9418 -15 , USB Cable, Input Terminal Labels, Input Cord Labels, 3197 Applications PC Program (CD-ROM), strap, carrying case, measurement guide, instruction manual 9657-10 3m cord CAT III 300V CAT III 300V Measurable conductor diameter φ30mm Primary current rating AC 10A AC 10A Output voltage Amplitude Accuracy (45 to 66 Hz) AC 100mV/A AC 100mV/A ±1.0%rdg.±0.005%f.s. ±1.0%rdg.±0.05%f.s. within ±5° within ±3° Phase Accuracy (50/60Hz) φ40mm 1mA (10A on forward and return) 5mA (100A on forward and return) Residual Current Frequency characteristic within ±5% at 40Hz to 5kHz within ±3% at 40Hz to 5kHz (accuracy deviation) Max. rated voltage to earth Maximum allowable input 300Vrms (insulated conductor) 10A continuous 30A continuous Dimensions and weight 60W×113H×24Dmm, 160g 74W×145H×42Dmm, 380g Notes Not compatible with power measurements nSUGGESTED OPTIONS for POWER MEASUREMENTS 3P4W Circuit testing of motors and breakers: 3197 Standard Package + 9661 (500A Sensor)×3 3P4W Circuit testing of external CTs: 3197 Standard Package + 9694 (5A Sensor)×3 3P Leakage testing: 3197 Standard Package + 9675 (10A Sensor)×3 HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 http://www.hioki.cn / E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected] 51W×58H×19Dmm, 50g 3m cord MODEL 130A continuous 9219 Connection Cord (3m; Option) 9675 nCOMPLETE LIST OF OPTIONS HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: [email protected] 60A continuous DISTRIBUTED BY Beijing Office : TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] HIOKI INDIA PRIVATE LIMITED : Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India TEL +91-731-4223901, 4223902 FAX +91-731-4223903 http://www.hioki.in / E-mail: [email protected] All information correct as of Jun. 4, 2010. All specifications are subject to change without notice. 3197E7-06B-03K Printed in Japan