9675 en

9675 / 9657-10
CLAMP ON SENSORS
9675
9657-10
9675
9657-10
3m cord
MODEL
3m cord
CAT III 300V
CAT III 300V
Measurable conductor diameter
φ30mm
φ40mm
Primary current rating
AC 10A
AC 10A
Output voltage
AC 100mV/A
AC 100mV/A
Amplitude Accuracy
(45 to 66 Hz)
±1.0%rdg.±0.005%f.s.
±1.0%rdg.±0.05%f.s.
Phase Accuracy (50/60Hz)
within ±5°
within ±3°
Residual Current
1mA (10A on forward and return)
5mA (100A on forward and return)
Frequency characteristic
(accuracy deviation)
within ±5% at 40Hz to 5kHz
within ±3% at 40Hz to 5kHz
Max. rated voltage to earth
300Vrms (insulated conductor)
Maximum allowable input
10A continuous
30A continuous
Dimensions and weight
60W×113H×24Dmm, 160g
74W×145H×42Dmm, 380g
Notes
Not compatible with power measurements
ASM GmbH Automation • Sensorik • Messtechnik
Am Bleichbach 18 - 22
85452 Moosinning
Tel. +49 8123 986-0
Fax: +49 8123 986-500
www.asm-sensor.de
[email protected]
© by ASM Moosinning 08/2010 Änderungen und Irrtümer vorbehalten. Schutzvermerk gemäß DIN34 beachten.
Ursprungsdatei: 3197E7-06B-03K vom 04.06.2010
9695-02/-03
CLAMP ON SENSORS
9695-02
9695-03
< CLAMP ON SENSOR SPECIFICATIONS
9695-02
9695-03
MODEL
CAT III 300V
CAT III 300V
Measurable conductor diameter
φ15mm
Primary current rating
AC 50A
AC 100A
Output voltage
AC 10mV/A
AC 1mV/A
Amplitude
(45 to 66 Hz)
±0.3%rdg.±0.02%f.s.
±0.3%rdg.±0.02%f.s.
Phase
(5Hz to 5kHz)
within ±2°
within ±1°
Accuracy
Frequency characteristic
(accuracy deviation)
within ±1.0% at 40Hz to 5kHz
Max. rated voltage to earth
(insulated conductor)
300Vrms
Maximum allowable input
(45 to 66 Hz)
60A continuous
130A continuous
Dimensions and weight
51W×58H×19Dmm, 50g
Requirements
9219 Connection Cord (3m; Option)
ASM GmbH Automation • Sensorik • Messtechnik
Am Bleichbach 18 - 22
85452 Moosinning
Tel. +49 8123 986-0
Fax: +49 8123 986-500
www.asm-sensor.de
[email protected]
© by ASM Moosinning 08/2010 Änderungen und Irrtümer vorbehalten. Schutzvermerk gemäß DIN34 beachten.