LUX METER FT3424

LUX METER FT3424
Environmental measuring instruments
Broad coverage from low to high illuminance
Measure at 0.01 lx resolution to a maximum of 200,000 lx
Compatible with LED lighting
• Complies with DIN Class B and JIS Class AA
• Save up to 99 measured values in the instrument’s
internal memory and transfer them to a computer
later for improved work efficiency
• Timer hold function lets you make measurements
in remote locations while avoiding the effects of
shadows and reflections
2
Support for measurement of 1 lx makes the FT3424 ideal for
low-illuminance measurement
20 lx range measurement resolution
0.01 lx
1. Timer hold function
Retain the measured value after a user-configured amount of time has
elapsed from the time the TIMER key is pressed. In this way, you can time
measurement to occur after you have moved away from the lux meter so that
measurement is not affected by clothing, shadows, etc.
Measurement delayed until
operator is out of the way
Effect of shadow
Timer settings
Select from 5 / 10 / 15 / 20 / 30 / 45 / 60 sec.
Remaining time display
Counts down with timer.
After the set time has elapsed
The measured value is retained. → The backlight turns on and the beep sounds for 3 sec.
2. Measurement with sensor and display units undocked
Large, easy-to-see LCD display
The backlight turns on automatically whenever a
measured value is retained in a low-illuminance
environment.
Connection Cable L9820(Option)
Relative Spectral Response Characteristics in the Visible Spectrum
Angled Incident Light Characteristics
Human perception of brightness ranges from 380 nm to 780 nm in the
wavelength and is the maximum at 555 nm. The lnternational Commission
on Illumination (CIE) has established comparative standards for luminosity,
setting the maximum perception for 1 and indicating the amount of
perception of each wavelength by the relative value, and calculating the
average of many people. In this instrument, the relative spectral response
characteristics are close to the comparative standards for luminosity.
It is known that the luminance is proportional to the cosine of
the incident angle of light (the cosine law).
In this instrument, the shape of the light sensor, hook etc. is
so made that it can follow the cosine law closely.
Graph illustrates typical characteristics.Characteristics exhibited by individual products may vary slightly.
3
DIN Class B and JIS Class AA compliant for optimal reliability
Key feature
Memory function makes multipoint measurement a breeze
1
Memory function (up to 99 values)
Save
in the field
Save measured values for multiple
measurement locations in the instrument’s
internal memory on the spot for later
display at your convenience.
2
Data communications functionality
Transfer to
your PC
Transfer data saved in the instrument’s
internal memory to a computer via a
USB connection. Data can be saved
as a text file.
Press the MEMORY key.
When making measurements at
numerous locations, this feature lets
you save values on the spot and then
create a report later in the office at your
convenience.
HOLD
POWER
TIMER
RANGE
0 ADJ
AUTO / ESC
CLEAR
MEMORY
TIMER
TIMER
F T 3424
LUX METER
CLEAR
AUTO / ESC
F T 3424
LUX METER
Record variations in illuminance with D/A output.
(Use a commercially available USB power adapter to supply power for
extended periods of time. )
Hioki Voltage Logger LR5042
Output voltage
2 V/ range f.s.
➔
HOLD
POWER
TIMER
RANGE
0 ADJ
CLEAR
MEMORY
READ
F T 3424
LUX METER
Output cord must be modified
to suit the connected device.
Record interval data using computer communications
software.
USB connection
HOLD
POWER
TIMER
RANGE
0 ADJ
AUTO / ESC
CLEAR
F T 3424
LUX METER
MEMORY
READ
AUTO / ESC
MEMORY
0 ADJ
RANGE
USB connection
MEMORY
0 ADJ
RANGE
HOLD
POWER
Key feature
AUTO / ESC
HOLD
POWER
READ
CLEAR
READ
F T 3424
LUX METER
READ
Other software functionalities
• Display graphs and save files for user-specified
time intervals. (Data can also be saved manually.)
• Display measured values on a computer screen in
real time.
Operating Environment
Interface: USB
OS: Windows 8,7, Vista (SP1 or later)
Specifications
Classification
Light receiving element
Display
Measurement ranges
Range selection
Linearity
Accuracy guarantee conditions
Accuracy guarantee
for temperature and humidity
Temperature characteristics
Humidity characteristics
Accuracy warranty period
DIN 5032-7: 1985 class B
JIS C 1609-1: 2006 general AA class
Silicon photodiode
Display: 4 digit, 2000 count LCD
Display unit: lx (lux)
Display update rate: 500 ms ±20 ms
Range
Measurement range
Display step
20 lx
0.00 lx to 20.00 lx
200 lx
0.0 lx to 200.0 lx
1 count/step
2000 lx
0 lx to 2000 lx
20000 lx
00 lx to 20000 lx
10 counts/step
100 counts/step
200000 lx
000 lx to 200000 lx
Auto/Manual
±2% rdg. (Multiply by 1.5 for display values in excess of 3000 lx.)
Sensor unit and display unit must bear the same collation number.
Oblique incident light characteristics
Angle
30°
60°
±7%
80°
±25%
Output specifications
Output method
Output level
D/A output
2 V/range f.s.
Resolution
Range
20 lx
200 lx
2000 lx
20000 lx
200000 lx
21°C to 27°C (69.8°F to 80.6°F), 75% RH or less (non-condensing)
±3% rdg.
±3% rdg.
2 years
Auto range: within 5 seconds
Manual range: within 2 seconds
AA/LR6 alkaline battery × 2
Power supply
R6 Manganese battery × 2
USB bus power 5V DC
Continuous battery operation time Approx. 300 hours (when using AA alkaline batteries)
Turns off the instrument 10 min. ±1 min. after the last key operation
Auto-power off
(can be canceled).
Operating temperature and humidity -10°C to 40°C (14°F to 104°F), 80% RH or less (non-condensing)
Storage temperature and humidity -20°C to 50°C (-4°F to 122°F), 80% RH or less (non-condensing)
Indoors, pollution degree 2, altitude up to 2000 m (6562-ft.)
Operating environment
Safety: EN61010, EMC: EN61326
Applicable standards
DIN 5032-7: 1985 class B
Standard compliance
JIS C 1609-1: 2006 general AA class
IP40 (EN60529)
Dustproof and waterproof
Approx. 78W × 170H × 39D mm (3.07″ W × 6.69″ H × 1.54″ D)
Dimensions and mass
Approx. 310 g (10.9 oz.) (including the batteries)
Instruction Manual ×1, AA/LR6 alkaline battery ×2, Sensor cap (with strap) ×1,
Accessories
Carrying case (soft) ×1, Strap ×1, USB cable (0.9 m) ×1,
CD-R (USB driver, dedicated computer application software, and
communications specifications) ×1
Deviation from cosine
characteristics
±2%
Response time
Output rate
1 mV DC/ 0.01 lx
1 mV DC/ 0.1 lx
1 mV DC/ 1 lx
1 mV DC/ 10 lx
1 mV DC/ 100 lx
Output update rate
Output accuracy
Output resistance
500 ms ±20 ms
±1% rdg. ±5 mV
(at output rate)
1.1 kW or less
Soft carrying case (included accessory)
For storing the FT3424.
Options
Connection Cable L9820
Output Cord 9094
Carrying case
C0202 (Soft case)
Use when positioning the
sensor unit and display unit
separately during use.
C0201 (Semi-hard case)
Required when using the
instrument's output function
(length: 1.5 m)
Handy for storing the instrument with the
Output Cord 9094, USB cable, and Connection
Cable L9820.
Stores the Output Cord 9094 and a
USB cable.
145W x 210H x 70D mm (5.7″ W × 8.27″ H × 2.76″ D)
137W x 193H x 69D mm (5.4″ W × 7.60″ H × 2.72″ D)
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) SALES & TRADING CO., LTD.:
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: [email protected]
DISTRIBUTED BY
HIOKI INDIA PRIVATE LIMITED:
TEL +91-124-6590210 FAX +91-124-6460113
HEADQUARTERS:
E-mail: [email protected]
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568 HIOKI SINGAPORE PTE. LTD.:
http://www.hioki.com / E-mail: [email protected] TEL +65-6634-7677 FAX +65-6634-7477
E-mail: [email protected]
HIOKI USA CORPORATION:
HIOKI KOREA CO., LTD.:
TEL +1-609-409-9109 FAX +1-609-409-9108 TEL +82-42-936-1281 FAX +82-42-936-1284
http://www.hiokiusa.com / E-mail: [email protected] E-mail: [email protected]
All information correct as of Aug. 22, 2014. All specifications are subject to change without notice.
FT3424E2-48E
Printed in Japan