8400 en

MEMORY HiLOGGER
LR8400-20, LR8401-20, LR8402-20
Data Loggers
Portable Data Logger with 30 Standard Channels
Expandible to 60 Channels
Only the size of an A4 sheet of paper, the HIOKI LR8400-20 Series is the realization of our goal to build a logger that provides the existing functionality of a
multi-channel data logger in a portable format. The new model comes with 30
channel capability as standard, to which another 30 channels can be added. All
input channels for measuring temperature, humidity, voltage and impedance are
isolated for safety, culminating in a powerful multi-measurement system that also
offers pulse and logic inputs. Long-term logging is coupled with the capability to
protect data against unexpected power outages and other problems for stable recordings over an entire year (see note).
Note: Continuous recordings lasting longer than 1 year are also possible.
2
In fuel cell, electric automobile and
other development Provides
assistance
with
■ Environmental measurements to
prevent global warming
■ Development of fuel cell
materials, energy field
■ Development of automobiles,
testing of automobile parts
■ Maintenance and inspection of
equipment
■ Monitoring plants
■ Testing of electrical products
■ Impedance testing of electronic
parts
■ Maximum voltage that can be input
between terminals: ±100 V DC
■ Multi-channel measurements
In the development of fuel cells, multiple power-generating cells
are connected to form a stack. Independent measurements of
each cell require multi-channel measurements of DC voltage, DC
current, temperature and other parameters.
The LR8400-20 Series comes with 30 channels as standard, which
can be expanded to 60 channels.
■ Maximum rated
voltage to earth:
300 V AC/DC
■ High withstand voltage
The HiLOGGER measures not only fuel cells, but also batteries for
UPS (uninterruptible power supplies) devices used in buildings as
well as batteries consisting of cells and packaging connected in
stacks that require multi-point measurements.
In such measurements, high voltage for the whole stack is
applied between channel-to-channel and channel-to-ground. Only
a measuring instrument with isolated inputs and high-capacity
withstand voltage characteristics can endure this.
■ High-speed sampling
In the development of automobiles such as electric vehicles (EV)
and plug-in hybrid vehicles (PHV) that use motors for propulsion,
abrupt changes in load need to be measured.
This makes the multi-channel, high-speed 10 ms sampling
capability of the LR8400-20 Series an indispensable feature.
■ Maximum rated
voltage between
each channels of
UNIVERSAL UNIT:
300 V DC
■ Maximum rated
voltage between
each channels of
VOLTAGE/TEMP
UNIT: 250 V DC
3
Highlights
Multimeasurements
Measure and record:
■ Temperature & humidity
■ A variety of transducer outputs (DC voltage)
■ Resistance values
Also comes with high withstand voltage; isolated inputs required when measuring and recording
battery cell voltages
Voltage measurement (DC only)
• 30 input channels
Note: The LR8400-20, LR8401-20 and LR8402-20 models
differ in the combination of input functions and terminals.
• All input channels are isolated
Note: Maximum rated voltage above ground between the
HiLOGGER and analog inputs is 300 V AC/DC.
Note: Maximum channel-tochannel voltage is a high
voltage of 300 V DC.
(Maximum voltage for
models with M3 screw input
terminals is 250 V DC.)
Temperature & humidity measurement
Temperature & resistance measurement
• Temperature measurements of thermocouples on 30
channels
• M3 screw terminal inputs enable secure connection
of even thin thermocouples
• Special sensor permits humidity measurements on
30 channels (optional Z2000)
• Universal inputs support temperature
measurements using Platinum resistance
temperature sensor (Pt100/ JPt100), or resistance
measurements (four wires)
Note: The sensor power supply is the M3 mm dia. screw terminal block on the left side.
Note: Both universal input terminals and M3 mm dia. input terminals enable humidity
measurements.
Note: These cannot be measured using the M3 screw input terminals
units.
Note: Supports resistance recording to enable assessment of
changes in resistance in the device under test. 4-terminal method,
measurement resolution 0.5 mΩ -, testing current 1 mA
To record 4 - 20mA instrumentation
signals, attach a commercially
available 250Ω shunt resistance
to the input terminals (between + and -)
to convert the signals to 1 - 5 V. Then
use the 1-5V or the 10V f.s. input range in
the HiLOGGER.
■ A compact A4 size enhances mobility
A compact A4 size footprint makes it ideal
for use in virtually any environment.
■ Helps also in collecting automotive data
Ideal for testing and collecting data on the
vibration characteristics of automotive
parts
Pulse totalization measurement
• 8 channel inputs (pulse and digital input selectable for
Pulse rotations measurement
Logical 1-0 measurement
• 8 channel inputs (pulse and digital input selectable for
• 8 channel inputs (digital and pulse input selectable for
• For measuring energy consumption and cumulative
flow
• For measuring rotational irregularities of motors
and drills
• The input signal shares common
• The input signal shares common
• 1 or 0 is recorded for each
recording interval
• The input signal shares common
Note: M3 screw input terminals
provide direct connection
Note: M3 screw input terminals
provide simple connection
Note: M3 screw input terminals
provide simple connection
each channel)
ground with the HiLOGGER
each channel)
ground with the HiLOGGER
each channel)
ground with the HiLOGGER
4
Accurately capture any phenomena
you want to measure
Highlights
■ 10 ms high-speed sampling
High-speed
Recording
Sampling at 100 ms intervals cannot
capture abrupt load changes
Sampling the same waveform at ten
times the speed, at 10 ms intervals,
accurately captures the changes.
Highlights
The development of hybrid and electric
automobiles requires instruments that can
measure abrupt load changes. Channels 1 to
15 provide 10-ms sampling and channels 16
to 30 provide 20-ms sampling. This channels
allow you to track waveforms not possible
with earlier models.
Note: Measurements on channels 31 to 60 provide 50-ms
sampling.
■ Enhanced noise suppression
A digital oversampling filter function reduces
inverter switching noise and 50/60 Hz hum
noise, a concern in earlier models, during
recording.
Noise
suppression
Note: The noise reduction effect improves with longer
recording intervals (i.e., at slower sampling speeds).
Without electric noise reduction, you will
obtain a waveform like the one above
in temperature measurements of an
electromagnetic cooker
Highlights
Easy-toview LCD
A digital filter in the HiLOGGER eliminates
high-frequency noise to enable accurate
temperature waveforms
■ 5.7 inch TFT LCD display is easy to view even at an angle
The LCD has a wider visual angle and is larger (5.7 inches, 640 × 480 dots)
than the STN LCD in our
previous model (8420-51s)
to facilitate observation
of waveforms on multiple
channels.
5
Store data securely for more than 1 year
■ Compatible with USB memory devices
Highlights
For even greater convenience, the HiLOGGER now provides support for USB
memory devices. Measurements can now immediately be written to a USB
memory device in real-time. USB memory devices are also a handy means to
transfer data to a PC.
Storage
Media
Note: Although USB memory devices enable real-time saving
of data, for more reliable data protection we recommend use
of HIOKI CF cards, which are guaranteed to work with the
instrument, for real-time saving of data.
■ Saving data to CompactFlash (CF) card
Use only HIOKI CF cards, which are manufactured
to strict industrial standards, for long-term storage of
important data.
Note: Operation of non-HIOKI CF cards is not guaranteed
■ Recording Capacity
Note: Use only HIOKI CF cards that are guaranteed to operate with the
HiLOGGER for continuous long-term recording.
Recording of 30 analog channels only (no pulse measurement, alarm output or waveform processing data)
Recording intervals
Internal memory
(16 MB)
10 ms
46m
For 15 or fewer analog channels
Model 9727
(256 MB)
12h 25m
Model 9728
(512 MB)
1d 00h 51m
Model 9729
(1 GB)
2d 01h 42m
Model 9830
(2 GB)
4d 03h 25m
20 ms
For 30 or fewer analog channels
1h 33m
1d 00h 51m
2d 01h 42m
4d 03h 25m
8d 06h 50m
50ms
3h 53m
2d 14h 08m
5d 04h 16m
10d 08h 33m
20d 17h 06m
100ms
7h 46m
5d 04h 16m
10d 08h 33m
20d 17h 06m
41d 10h 12m
200ms
15h 32m
10d 08h 33m
20d 17h 06m
41d 10h 12m
82d 20h 24m
500ms
1d 14h 50m
25d 21h 22m
51d 18h 45m
103d 13h 30m
207d 03h 01m
1s
3d 05h 40m
51d 18h 45m
103d 13h 30m
207d 03h 01m
414d 06h 03m
2s
6d 11h 20m
103d 13h 30m
207d 03h 01m
414d 06h 03m
"★"
5s
16d 04h 21m
258d 21h 47m
517d 19h 34m
"★"
"★"
10s
32d 08h 43m
517d 19h 34m
"★"
"★"
"★"
20s
64d 17h 26m
"★"
"★"
"★"
"★"
30s
97d 02h 10m
"★"
"★"
"★"
"★"
1min
194d 04h 20m
"★"
"★"
"★"
"★"
2min
388d 08h 40m
"★"
"★"
"★"
"★"
5min to 1hour
"★"
"★"
"★"
"★"
"★"
• Maximum recording time is inversely proportional to number of recording channels.
• Because the actual capacity of a CF card is less than that indicated, and because the header portion of waveform files is not included in capacity
calculations, expect actual maximum times to be about 90% of those in the table.
• "★" exceeds 1 year.
Highlights
Replacing
cards
■ Cards can be replaced during real-time recording
This function has been provided to enable removal of cards during recording
to allow the user to analyze the data recorded so far.
This makes it possible to replace USB memory devices and CF cards during
real-time recording without having to stop measurements.
Note: During high-speed recording, be sure to insert the new storage media within 2 minutes of
removing a card.
6
A host of useful functions and features
VOLTAGE/TEMP UNIT LR8500
● 15ch
● M3 screw terminals
(2 terminals per channel)
UNIVERSAL UNIT LR8501
● 15ch
● Push-button type terminals
(4 terminals per channel)
Function
highlights
Easy
installation
■ Up to two additional 15 channel input units
can be added
The need for more measurement channels can be
met even after purchasing the instrument. The
instrument comes with 30 channels as standard, but
another two 15 channel input units can be added to
expand the total number of channels to 60.
Note: The units provided with the unit as standard cannot be
removed.
Function
highlights
Ease of use
■ Input setting screens with waveform monitoring
The HiLOGGER adopts the setting screens that earned its
sister model (8430-20) a reputation for user-friendliness.
Range settings, warnings, triggers, waveform processing
and other measurement input settings can be taken in at a
glance.
7
Function
highlights
■ Alarm output
The HiLOGGER outputs a signal when alarm criteria
are satisfied and also sounds a buzzer. Four systems are
provided as standard and separate criteria can be set for
each input source enabling OR and AND criteria between
channels.
Alarm output
Note: Open-collector output (5 V voltage output and relay drive capacity 5
to 30 V, 200 mA)
Function
highlights
Weathers
power outages
■ Trickle charging the internal battery
An internal battery (optional accessory)
is charged when the AC adapter is
connected. Since the internal battery
will automatically take over in the event
of a sudden power outage, it permits
uninterruptible operation.
Function
highlights
■ Protection of files being stored on external storage
media
An internal high-capacity capacitor will provide enough
power to store any data at risk on a CF card or USB
memory device should a sudden power outage occur during
long-term storage. This reduces the risk of data loss and
corruption of the file system. Measurements will resume as
soon as the power returns.
■ Real-time processing functions
The HiLOGGER comes with [four arithmetic operation]
functions for processing between channels. Data processed
in real-time can be displayed in graph form. In addition,
processing results for 30 channels are stored in internal
memory and can be handled as data for independent input
channels.
Calculation
Functions
■ Records average values every 30 minutes
The HiLOGGER contains a [time-span processing]
function. The instrument will save processing data as text
data for a preset time period in real-time.
Function
highlights
■ Simultaneous recording to storage media and PC
Measurement data can be simultaneously saved to external
storage media and a hard disk
on a PC connected to a
network to reduce the risk
data loss.
USB / LAN
Communication
USB
LAN
■ USB and LAN connection for easy setup
The supplied Logger Utility software allows you to set up
the logger from a PC. Setup could not be easier. Just follow
the numbered procedures to set up the instrument.
Note: Data on an inserted CF card can be copied to a PC via USB
connection.
Note: The Logger Utility will enable LAN access with software Ver. 1.20
or later.
8
Bundled user-friendly software for
PC analysis
Function
highlights
PC
Measurement
■ The supplied Logger Utility software enables processing of measurement data on
a PC
■ View past data during recording
■ Output PC data to a printer
■ Control of measurements from a PC screen
Connect the PC to the HiLOGGER using USB or via LAN*
(see note). Use the supplied Logger Utility software to record
data on a PC in real-time. Scroll backwards through the
displayed trend graph window to view past waveforms even
while recording. Up to five HiLOGGERs can be connected
to one PC.
■ Analyze after measuring
Our new “dual-knob function” greatly simplifies data
analysis. Two separate waveform windows are provided,
with the displayed waveforms showing different time-axis
scales (time bases). This capability substantially simplifies
long-term data analysis. (Patent pending)
Entire Recording Length: 1 s/div
Segment A
50 ms/div magnification
Segment A View
Segment B
100 ms/div magnification
Segment B View
Spans entire recording length
■ Remote control through HTTP server function*
Without the need to install additional software, you can
use an ordinary web browser on your PC to set up the
HiLOGGER, acquire data and monitor data on the screen.
■ Data acquisition via FTP*
FTP allows the PC to acquire files stored
on HiLOGGER storage devices or
measurement data in internal memory.
■ Data transfer via FTP*
Data saved in real-time to storage media can be
automatically transferred to an FTP server started
from the PC either at regular intervals during
measurements or when measurements end.
*Note: LAN communication functions support planned from software Ver. 1.20.
■ Be informed via E-mail*
Your PC or mobile device is notified of storage
media full, internal memory full, stop trigger
invoked, alarm occurrence and other events via
E-mail.
9
■ Product Specifications
General specifications (product and accuracy guaranteed for one year)
Internal memory
Internal clock
Accuracy of timebase
Backup battery
Operating temp. &
humidity
16 Mega-bytes (8M data points)
Auto calendar, Precision ±3 s/ day (at 23 °C/ 73 °F)
±0.2s/ day on measurement (at 23 °C/ 73 °F)
For clock and setting conditions: battery life 5 years (at 23 °C/ 73 °F)
Dimensions &
Mass
Graph time axis
100 ms/ div to 1 day/ div (21 selections)
Recording Time
Enable continuous recording ON (records until the Stop key is pressed),
or continuous recording OFF (enable a specified time span)
(sampling period)
charging: 10 °C/ 50 °F to 40 °C/ 104 °F)
External trigger input, Trigger output, 4 channel alarm outputs, +12
V/ 100 mA max. output, GND
Approx. 272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D,
1.8 kg (63.5 oz), (LR8400 main unit, except the Battery Pack 370 g/ 13.1 oz)
Approx. 272 mm (10.71 in) W × 234.8 mm (9.24 in) H × 66.5 mm (2.62 in) D,
2.6 kg (91.7 oz), (LR8500 × 2 and LR8400 × 1, except the Battery Pack 370 g/
13.1 oz)
Accessories
Recording
Intervals
10 ms*1, 20 ms*2, 50 ms*3, 100 ms to 1 hr (19 selections)
Note: All input channels are scanned at high speed during every recording
interval
*1 Thermocouple burn-out detection OFF, and using up to 15 channels
*2 Thermocouple burn-out detection OFF, and using up to 30 channels, or
Thermocouple burn-out detection ON, and using up to 15 channels
*3 Thermocouple burn-out detection OFF, and using up to 60 channels, or
Thermocouple burn-out detection ON, and using up to 30 channels
0 °C (32 °F) to 40 °C (104 °F), 80 % rh or less (non-condensating, when
Storage temp. &
-10 °C (14 °F) to 60 °C (140 °F), 80 % rh or less, (non-condensating)
humidity
Conforming standards Safety : EN61010-1, EMC : EN61326-1, EN61000-3-2, EN61000-3-3
JIS D1601: 1995 5.3 (1) Corresponds to Class 1: a passenger car,
Anti-vibration
Condition: class A
External control
terminal
Measurement Settings
Detailed operating manual ×1, Measurement guide ×1, AC ADAPTER 941815 ×1, USB cable ×1, CD-R (data collection software "Logger Utility") ×1
(ON/OFF) Enable to repeat recording after the specified recording
Repeating Recording time span has elapsed
Data Saving
Select a CF card or USB memory (Use only PC Cards sold by HIOKI)
Auto: Save waveform data or time divided calculation results in real time
Storage operation Manual: Push the save key (operation select: item choose/ directly save)
Possible: Waveforms are saved approximately one minute as binary or CSV
Storage media
Real-time saving
Data storage media
CF card
USB memory
CF card slot ×1, HIOKI 9727 (256 MB), 9728 (512 MB), 9729 (1 GB),
9830 (2 GB), Data format: FAT, FAT32
Series A receptacle
Communication function
IEEE 802.3 Ethernet 100BASE-TX, DHCP, DNS capable
• Data acquisition, condition settings used with the Logger Utility software
(supplied as standard)
• Use the communication command to set and measure
(ver. 1.20 or later)
• Data download via FTP server function (stored in the CF card or the USB memory)
• Automatically transmit data via FTP client function
• Remote control via HTTP server function
• Send mail function via E-mail system
USB 2.0 High-speed capable, series mini-B receptacle
• Data acquisition, condition settings used with the Logger Utility
USB communication software (supplied as standard)
interface
• Configure the unit and measure using communication commands
• Transfer data from the CF card to a PC via USB drive mode (data
LAN interface
transfer not possible from USB memory sticks)
Display section
Display device
LCD Brightness
5.7 inch TFT color liquid crystal display (640 × 480 pixel), horizontal
15 division, vertical 10 division, selectable between English and
Japanese displays, Back light saver available
Selectable from 100, 70, 40, or 25 %
Power supplies
AC Power
DC Power
External
Using the AC ADAPTER 9418-15 (supplied as standard, 100 to 240 VAC, 50/60
Hz),
Power consumption: 7 VA (with battery pack removed and maximum brightness)
Using the BATTERY PACK Z1000 (optional accessory, AC adapter has
priority when used in combination with battery pack)
Continuous operation time: 5 hours (at 23 °C, LCD brightness 25 %)
Fast recharging time: 3 hours (using the AC adapter and main unit to
recharge the battery, at 23 °C, reference value)
10 to 28 VDC (Rechargable voltage 12 to 16 VDC, Please contact your HIOKI
distributor for connection cord)
Maximum rated power: 24 VA (at 16 VDC external power supply, battery
charge, LCD brightness 100 %)
Trigger functions
Trigger mode,
timing
Analog signal
source
Pulse signal
source
Digital signal
source
Timer trigger
Trigger output
Modes : Single / Repeat, Timing : Start / Stop / Start & Stop, Logical
sum (OR) and product (AND) of each trigger source, Selectable for
each channel
Configure each individual channel for 30 channels or up to 60 channels
depending on number of additional terminal modules installed.
[Level trigger] Triggers when rising or falling through preset level
[Window] Triggers when entering or exiting range defined by preset
upper and lower limit values
8 channels of pulse totalizer inputs
[Level trigger] Triggers when rising or falling through preset level
[Window] Triggers when entering or exiting range defined by preset
upper and lower limit values
8 channels of digital signal inputs
[Logic pattern trigger] agreement (or disagreement) in the specified
[1/ 0/ ×] pattern
Set up for year/ month/ day/ hour/ minute/ second
Open collector (active low, with 5 V output, at least 10 ms pulse
width), M3 mm screw terminal
Alarm output
Number of channels 4 channels, non-isolated (common ground with chassis)
60 channels of analog input, 8 channels of pulse totalizer inputs or
Alarm source
digital inputs, Thermocouple burn-out detection
Level, Window, Logic pattern, Output latch/ no latch, Cancel alarm
Alarm type
while measuring
Buzzer, ON/OFF possible
Alarm sound
Open collector (active low, with 5 V output), M3 mm screw terminal,
Alarm output
Output refreshed at every recording interval
Output sink current 200 mA at 5 V to 30 VDC
Note: Setting is independent from the recording interval
Divided saving
Delete & save
Interruptions
during saving
data to the CF card or the USB memory (if sampling rate is slower than 1
minute, waveforms are saved at each interval)
To the PC: Waveforms are saved to the HDD in the PC via LAN or USB
communication when used with the Logger Utility Software. Data can be
saved in real time to the CF card or USB memory at the same time.
Simple divide: Save waveform data at pre-set times into separate files from
the time measurement starts.
On schedule: Designate a reference time within 24 hours and save data into
separate files at every set time interval starting from the reference time.
Endless loop saving: New file overwrites the oldest file when the CF card
or USB memory capacity runs short
Storage media may be removed during real-time save after message
confirmation.
Upon inserting the storage media again, data saved in internal memory
during that time will be saved as a separate file in the media.
Possible: When a power failure occurs during real-time save, the file close
sequence is completed before the unit is shut down. When powering with
batteries and low battery power is detected, the file close sequence will
automatically be executed.
Data protect
Saved data types
Loading data
Setting condition, Waveform data (binary or text style), Calculation
of numerical value, Screen data (compressed BMP)
Stored binary data can be recalled by the HiLOGGER in 16 MB
quantities
Calculation function
Numerical value
calculations
Data range of
calculation
Calculation value
save
Waveform
calculations
No. 1 to 6, maximum 6 calculations can be conducted simultaneously
Selections: average value, peak value, maximum value, time at maximum value,
minimum value, time at minimum value
During measurement or after stopping: Store all data or data between A
and B cursors into internal memory
Times: Calculate values at pre-determined 1 sec to 1 day intervals and
display the latest value
Possible: After measuring the last calculated value is automatically saved
to the CF card or USB memory as a text file
Timed save: Save calculated data at pre-determined 1 sec to 1 day intervals
as text data to the CF card or USB memory in real time.
*4 arithmetic calculations between each channel
*Separate display of calculation graphs (only during measurement) and
input waveforms
*Real-time save of calculation graph data
Other functions
Event marking
A-B cursor
Scaling
Rate adjustment
Comment input
Other
Search: Move to the event number entered and display the waveforms
appearing before and after event
Number of events: Maximum 100 per measurement
Measurement: time difference between A and B, electric potential
difference, electric potential of A or B and time
Type: Trace the data, amplitude axis, time axis
Convert and display the measurement value of each channel as a scaled value
Scaling can be set for a channel so that its value is the same as that for UNIT1-CH1
Enter a title or a comment for each channel
Start backup, save ten types setting conditions into main unit, auto
set up, start/stop key lock, key-lock, beep sound
Pulse, Digital input
(digital / pulse selectable for each channel, M3 screw terminal
Number of channels 8×channels,
8ch, 2 terminals per channel, not isolated, common ground)
No-voltage 'a' contact (normally open contact), open collector or
Input condition
voltage input, Input resistance: 1.1 MΩ
Max. allowable input 0 V to 50 VDC (maximum voltage between input terminals that does not
cause damage)
Max. rated voltage Not isolated (common ground)
between channels
Max. rated voltage to earth Not isolated (common ground)
2 selectable levels (H: over 1.0 V, L: 0 - 0.5 V), (H: over 4.0 V, L: 0 - 1.5 V)
Detect level
With filter OFF: 200 μs or more (both H and L periods must be at least 100 μs)
Pulse input period With filter ON: 100 ms or more (both H and L periods must be at least 50 ms)
Rising or falling edge can be set for each channel
Slope
Totalized pulses: Integrated (pulse count integration from start),
Pulse measurement Instantaneous (pulse count value at each sampling, and integrated value is
reset each time)
mode
Rotation count: Count input pulses during one second
For contact bound resistant (ON/OFF set for each channels)
Filter
Measurement parameters
Ranges
Finest Resolution Range of Measurements
1,000 M (pulse) f.s.
1 (pulse)
0 to 1,000 M (pulse)
Pulse totalization
5,000/n (r/s) f.s.
1/n (r/s)
0 to 5,000/n (r/s)
Pulse rotations
"n" above is the number of sensor output pulses per rotation, 1 to 1,000
Digital input
Record logical "1" or "0" at each sampling
10
■ Product Specifications
Analog input section (@23 ±5˚C/73 ±9˚F, 30 to 80% rh., from 30 minutes after power on)
Voltage Setting Ranges Resolution
Measurement range
10 mV f.s.
500 nV
-10 mV to 10 mV
20 mV f.s.
1 μV
-20 mV to 20 mV
100 mV f.s.
5 μV
-100 mV to 100 mV
200 mV f.s.
10 μV
-200 mV to 200 mV
1 V f.s.
50 μV
-1 V to 1 V
2 V f.s.
100 μV
-2 V to 2 V
10 V f.s.
500 μV
-10 V to 10 V
20 V f.s.
1 mV
-20 V to 20 V
100 V f.s.
5 mV
-100 V to 100 V
1 − 5 V f.s.
500 μV
1 V to 5 V
Temperature Thermocouples (Compliance standard)
(Excluding standard reference
contact accuracy)
500 ˚C f.s.
0.01 ˚C
0.05 ˚C
K
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
J
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
E
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
T
N
Measurement range
-100 to less than 0 ˚C
0 to 100 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 500 ˚C
-200 to less than -100 ˚C
-100 to 1350 ˚C
-100 to less than 0 ˚C
0 to 100 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 500 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 1200 ˚C
-100 to less than 0 ˚C
0 to 100 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 500 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 1000 ˚C
-100 to less than 0 ˚C
0 to 100 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 400 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 400 ˚C
-100 to less than 0 ˚C
0 to 100 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 500 ˚C
-200 to less than -100 ˚C
-100 to less than 0 ˚C
0 to 1300 ˚C
Thermocouple Setting Ranges Resolution
100 ˚C f.s.
500 ˚C f.s.
0.01 ˚C
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
500 ˚C f.s.
0.01 ˚C
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
500 ˚C f.s.
2000 ˚C f.s.
0.01 ˚C
0.05 ˚C
0.1 ˚C
R
S
K, J, E, T, N, R, S, B : JIS C1602-1995, IEC 584
W : ASTME-988-96
Thermocouple Setting Ranges Resolution
100 ˚C f.s.
Accuracy
±10 μV
±20 μV
±100 μV
±200 μV
±1 mV
±2 mV
±10 mV
±20 mV
±100 mV
±10 mV
Accuracy
±0.8 ˚C
±0.6 ˚C
±1.5 ˚C
±0.8 ˚C
±0.6 ˚C
±1.5 ˚C
±0.8 ˚C
±0.8 ˚C
±0.6 ˚C
±1.0 ˚C
±0.8 ˚C
±0.6 ˚C
±1.0 ˚C
±0.8 ˚C
±0.6 ˚C
±0.8 ˚C
±0.6 ˚C
±1.0 ˚C
±0.8 ˚C
±0.6 ˚C
±1.0 ˚C
±0.8 ˚C
±0.6 ˚C
±0.8 ˚C
±0.6 ˚C
±1.5 ˚C
±0.8 ˚C
±0.6 ˚C
±1.5 ˚C
±0.8 ˚C
±0.6 ˚C
±1.2 ˚C
±1.0 ˚C
±2.2 ˚C
±1.2 ˚C
±1.0 ˚C
±2.2 ˚C
±1.2 ˚C
±1.0 ˚C
B
W
Measurement range
0 to 100 ˚C
0 to less than 100 ˚C
100 to less than 300 ˚C
300 to 500 ˚C
0 to less than 100 ˚C
100 to less than 300 ˚C
300 to 1700 ˚C
0 to 100 ˚C
0 to less than 100 ˚C
100 to less than 300 ˚C
300 to 500 ˚C
0 to less than 100 ˚C
100 to less than 300 ˚C
300 to 1700 ˚C
400 to less than 600 ˚C
600 to less than 1000 ˚C
1000 to 1800 ˚C
0 to 100 ˚C
0 to 500 ˚C
0 to 2000 ˚C
Accuracy
±4.5 ˚C
±4.5 ˚C
±3.0 ˚C
±2.2 ˚C
±4.5 ˚C
±3.0 ˚C
±2.2 ˚C
±4.5 ˚C
±4.5 ˚C
±3.0 ˚C
±2.2 ˚C
±4.5 ˚C
±3.0 ˚C
±2.2 ˚C
±5.5 ˚C
±3.8 ˚C
±2.5 ˚C
±1.8 ˚C
±1.8 ˚C
±1.8 ˚C
Other specifications about thermocouple measurement
Reference junction compensation
Internal/ External, at INT RJC, total accuracy = add ± 0.5 ˚C
Thermocouple burn-out detection ON/ OFF, detect at each sampling (when slower than 20 ms)
(Compliance standard)
Temperature Platinum
Pt 100 : JIS C1604-1997, IEC 751, JPt 100 : JIS C1604-1989
resistance temperature sensor
Types
Setting Ranges Resolution
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
100 ˚C f.s.
0.01 ˚C
500 ˚C f.s.
0.05 ˚C
2000 ˚C f.s.
0.1 ˚C
Measurement range
-100 to 100 ˚C
-200 to 500 ˚C
-200 to 800 ˚C
-100 to 100 ˚C
-200 to 500 ˚C
-200 to 500 ˚C
Accuracy
±0.6 ˚C
±0.8 ˚C
±1.0 ˚C
±0.6 ˚C
±0.8 ˚C
±1.0 ˚C
Resistance /testing current 1 mA Resolution
10 Ω f.s.
0.5 mΩ
20 Ω f.s.
1 mΩ
100 Ω f.s.
5 mΩ
200 Ω f.s.
10 mΩ
Measurement range
0 to 10 Ω
0 to 20 Ω
0 to 100 Ω
0 to 200 Ω
Accuracy
±10 mΩ
±20 mΩ
±100 mΩ
±200 mΩ
Humidity (use sensor Z2000) Resolution
100 %rh f.s.
0.1 %rh
Measurement range
5.0 to 95.0 %rh
Refer to table below
Pt 100
JPt 100
Accuracy
n Humidity sensor Z2000 accuracy
Filter function (Thermocouple/ Resistance temperature sensor/ Voltage/ Resistance/ Humidity)
Digital filter
Select OFF/ 50 Hz/ 60 Hz (In order to remove harmonic components, during analog
input the cut-off frequency is automatically set according to the sampling rate)
■ Optional Product Specifications
UNIVERSAL UNIT LR8501 (product and accuracy guaranteed for one year)
VOLTAGE/TEMP UNIT LR8500 (product and accuracy guaranteed for one year)
Number of input
channels
Measurement
parameters
Input conditions
Number of input
channels
15 channels (input type selectable from voltage, thermocouple, humidity,
for each channel), M3 screw terminals (2 terminals per channel)
Isolated from each other channels and from chassis
Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W)
Humidity with the sensor Z2000
Measurement
parameters
Input resistance: 1 MΩ (at voltage/ thermocouple measurement)
Max. rating: ±100 V DC (max. voltage between input terminals without damage)
Input conditions
Max. rated voltage between
250 V DC (max. voltage between input channel terminals)
isolated input channels
Max. rated voltage from
300 V AC, DC (max. voltage from terminals to chassis ground without damage)
isolated terminals to ground
Measurement accuracy Refer to MEMORY HiLOGGER main unit specifications
Approx. 128 mm (5.04 in) W × 52.8 mm (2.08 in) H × 64.5 mm (2.54 in)
Dimensions & Mass
D, 380 g (13.4 oz)
15 channels (input type selectable from voltage, thermocouple, Pt 100/ JPt 100, humidity,
resistance, for each channel), Push-button type terminals (4 terminals per channel)
Isolated from each other channels and from chassis
Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W)
Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/ 4-wired,
testing current 1 mA)
Resistance (4-wired, testing current 1 mA)
Humidity with the sensor Z2000
Input resistance: 1 MΩ (at voltage/ thermocouple measurement), 2 MΩ (at
platinum resistance temperature sensor, or resistance measurement)
Max. rating: ±100 V DC (max. voltage between input terminals without damage)
Max. rated voltage between
300 V DC (max. voltage between input channel terminals)
isolated input channels
300 V AC, DC (max. voltage from terminals to chassis ground without damage)
Max. rated voltage from
Caution: Not isolated from each other and common GND at resistance
isolated terminals to ground temperature sensor or resistance measurement input
Measurement accuracy Refer to MEMORY HiLOGGER main unit specifications
Approx. 128 mm (5.04 in) W × 52.8 mm (2.08 in) H × 64.5 mm (2.54 in)
Dimensions & Mass
D, 300 g (10.6 oz)
11
Model Line-up
Items
Specifications
Model LR8400-20 (with built-in VOLTAGE/TEMP UNIT × 2)
Built-in 30 channels (Isolated from each other channels and chassis)
[UNIT-1, UNIT-2] M3 screw terminals × 30 channels (2 terminals per channel)
Expandable by adding 30 more channels for a total of 60 input channels
Analog input
Caution: Built-in M3 screw terminal units cannot be removed or replaced
M3 screw
terminals × 15
(optional input unit, Model LR8500 or LR8501, up to 2 units)
Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W)
Measurement
parameters
Humidity with the sensor Z2000
Input resistance
1 MΩ (at voltage/ thermocouple measurement)
Max. allowable input
±100 V DC (max. voltage between input terminals without damage)
Max. rated voltage between
isolated input channels
250 V DC (max. voltage between input channel terminals)
Max. rated voltage from isolated
terminals to ground
300 V AC, DC (max. voltage from terminals to chassis ground without damage)
Items
Specifications
Model LR8401-20 (with built-in UNIVERSAL UNIT × 2)
Built-in 30 channels (Isolated from each other channels and chassis)
[UNIT-1, UNIT-2] Push-button type terminals × 30 channels (4 terminals per channel)
Expandable by adding 30 more channels for a total of 60 input channels
Analog input
Caution: Built-in push-button terminal units cannot be removed or replaced
Push-button type
terminals × 15
(optional input unit, Model LR8500 or LR8501, up to 2 units)
Max. allowable input
Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W)
Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/ 4-wired, testing current 1 mA)
Resistance (4-wired, testing current 1 mA)
Humidity with the sensor Z2000
1 MΩ (at voltage/ thermocouple measurement)
2 MΩ (at resistance temperature sensor, or resistance measurement)
±100 V DC (max. voltage between input terminals without damage)
Max. rated voltage between
isolated input channels
300 V DC (max. voltage between input channel terminals)
Max. rated voltage from isolated
terminals to ground
300 V AC, DC (max. voltage from terminals to chassis ground without damage)
Caution: Not isolated from each other and common GND at resistance temperature sensor or
resistance measurement input
Measurement
parameters
Input resistance
Items
Specifications
Expandable by adding 30 more channels for a total of 60 input channels
(optional input unit, Model LR8500 or LR8501, up to 2 units)
Measurement
parameters
Input resistance
Max. allowable input
Push-button type
terminals × 15
Model LR8402-20 (with built-in UNIVERSAL UNIT × 1, VOLTAGE/TEMP UNIT × 1)
Built-in 30 channels (Isolated from each other channels and chassis)
[UNIT-1] Push-button type terminals × 15 channels (4 terminals per channel)
[UNIT-2] M3 screw terminals × 15 channels (2 terminals per channel)
Analog input
Max. rated voltage between
isolated input channels
M3 screw
terminals × 15
Caution: Built-in push-button terminal unit and M3 screw terminal unit
cannot be removed or replaced
Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W), Humidity with the
sensor Z2000
[UNIT-1 side only] Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/
4-wired), Resistance (4-wired)
1 MΩ (at voltage/ thermocouple measurement)
2 MΩ (at platinum resistance temperature sensor, or resistance measurement)
±100 V DC (max. voltage between input terminals without damage)
250 V DC at M3 screw terminals, 300 V DC at push-button type terminals
Push-button type
terminals × 15
M3 screw
terminals × 15
(max. voltage between input channel terminals)
Max. rated voltage from isolated 300 V AC, DC (max. voltage from terminals to chassis ground without damage)
terminals to ground
Caution: Not isolated from each other and common GND at resistance temperature sensor or
resistance measurement input
■ Bundled software specifications
Logger Utility (bundled application software)
Operating
environment
One CD-R, CPU: Pentium 3 (500 MHz or more), at least 512 MB of memory
Interface: USB, LAN (LAN not available with the Model 8430-20/-21)
OS: Windows 2000 (SP4 or later)/ XP (SP2 or later)/ Vista (32-bit/ 64-bit),
(Ver 1.50 or later) Windows 7 (32-bit/ 64-bit)
Data conversion
Target data: Real-time data acquisition file (LUW format), Record to
internal memory data (MEM format), Waveform processing data
Converted sections: All data, designation section
Format: CSV format (separate by comma, space, tab), transfer to EXCEL
spreadsheet, arbitrary data thinning
Parameter
calculations
Target data: Real-time data acquisition file (LUW format), Record to
internal memory data (MEM format), Data acquired in real time, Waveform
processing data
Calculation items: average, peak, maximum values, time to maximum
values, minimum values, time to minimum values, ON time, OFF
time, count the number of ON time and OFF time, standard deviation,
integration, area values, totalization
Search function
Target data: Real-time data acquisition file (LUW format), Record to
internal memory data (MEM format), Waveform processing data,
Search mode: event mark, time and date, maximum position,
minimum position, maximum pole, minimum pole, alarm position,
level, window, amount of change
(This software is compatible only to the MEMORY HiLOGGER LR8400-20s,
LR8400-21s, 8423, 8430-20/-21)
Measurements on multiple loggers connected by LAN* or USB can be
controlled to sequentially acquire, display and save waveform data (for
recording up to 10 million samples)
*LAN available with HiLOGGER main unit Ver 1.20 or later
Real-time data
acquisition
Data acquisition
settings
Number of controllable instruments: up to 5 units
Display: Waveforms (multiple time axis can be displayed), Numerical values
(logging), Alarm status at the same time, Numerical value monitoring in a
separate window, Waveform scroll while measuring
Data saving destination: Real-time data transfer to EXCEL (new function),
or Real-time data acquisition file (LUW format, only for HIOKI)
Event marks: can be applied while recording
Data acquisition settings for the HiLOGGER
Saving: The setting for multiple HiLOGGERs can be saved together
in one file (LUS format); Instrument configuration settings can be sent
and received
Processed data file: Real-time data acquisition file (LUW format), Record
to internal memory data (MEM format)
Display format: Simultaneously display waveform and numerical value,
Waveform display
Print function
(time-axis divided display possible)
Maximum number of channels: 300 channerls (measurement data, used with
the LR8400-20s, LR8400-21s) + 60 channels (waveform processing data)
Others: Waveform display on sheet for each channel, scroll, record event
mark, cursor, hard copy, numerical value display
Supported printer: printer compatible with the OS
Target data: Real-time data acquisition file (LUW format), Record to
internal memory data (MEM format), Waveform processing data
Print format: waveform image, report format, list print (channel
settings, event, cursor value)
Print area: the entire area, area between cursors A and B
Print preview: supported
Waveform
processing
Processing items: Four arithmetic operations
Number of processing channels: 60 channerls
Main units and Options in Detail
LR8400-20
(with built-in VOLTAGE/TEMP UNIT × 2)
Built-in units are equivalent to the VOLTAGE/TEMP UNIT LR8500 (15 ch) × 2
Caution: Built-in units cannot be removed or changed
LR8401-20
(with built-in UNIVERSAL UNIT × 2)
Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 2
Caution: Built-in units cannot be removed or changed
LR8402-20
(with built-in UNIVERSAL UNIT × 1, VOLTAGE/TEMP UNIT × 1)
Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 1, and
VOLTAGE/TEMP UNIT LR8500 (15 ch) × 1
Caution: Built-in units cannot be removed or changed
Measurement and input options
VOLTAGE/TEMP UNIT LR8500
2 terminals M-3 mm screw type, 15 channels
Voltage, Temperature with thermocouple, or
Humidity measurement
UNIVERSAL UNIT LR8501
HUMIDITY SENSOR Z2000
4 terminals push-button type, 15 channels
Voltage, Temperature with thermocouple,
Platinum Resistance temperature sensor,
Humidity, or Resistance measurement
Removable storage (CF card)
3 m (9.84 ft) length
Power supplies
PC communication
Supplied with PC Card adapter
PC CARD 2G 9830
(2 GB capacity)
PC CARD 1G 9729
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
(1 GB capacity)
Charges while installed in the
HiLOGGER
PC CARD 512M 9728
(512 MB capacity)
BATTERY PACK Z1000
PC CARD 256M 9727
NiMH, Charges while installed
(256 MB capacity)
LAN CABLE 9642
AC ADAPTER 9418-15
Supplied as standard, 100 to 240 V AC
Straight Ethernet cable, supplied with
straight to cross conversion adapter, 5 m
(16.41 ft) length
Cases
CARRYING CASE C1000 FIXED STAND Z5000
Includes compartment for options
For wall hanging and slanted bench
mounting
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road,
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
http://www.hioki.cn / E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
http://www.hioki.co.jp / E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
DISTRIBUTED BY
Beijing Office :
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
HIOKI INDIA PRIVATE LIMITED :
Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India
TEL +91-731-4223901, 4223902 FAX +91-731-4223903
http://www.hioki.in / E-mail: [email protected]
All information correct as of Jul. 13, 2010. All specifications are subject to change without notice.
LR8400-20E4-07M-00K
Printed in Japan