MEMORY HiLOGGER LR8400-20, LR8401-20, LR8402-20 Data Loggers Portable Data Logger with 30 Standard Channels Expandible to 60 Channels Only the size of an A4 sheet of paper, the HIOKI LR8400-20 Series is the realization of our goal to build a logger that provides the existing functionality of a multi-channel data logger in a portable format. The new model comes with 30 channel capability as standard, to which another 30 channels can be added. All input channels for measuring temperature, humidity, voltage and impedance are isolated for safety, culminating in a powerful multi-measurement system that also offers pulse and logic inputs. Long-term logging is coupled with the capability to protect data against unexpected power outages and other problems for stable recordings over an entire year (see note). Note: Continuous recordings lasting longer than 1 year are also possible. 2 In fuel cell, electric automobile and other development Provides assistance with ■ Environmental measurements to prevent global warming ■ Development of fuel cell materials, energy field ■ Development of automobiles, testing of automobile parts ■ Maintenance and inspection of equipment ■ Monitoring plants ■ Testing of electrical products ■ Impedance testing of electronic parts ■ Maximum voltage that can be input between terminals: ±100 V DC ■ Multi-channel measurements In the development of fuel cells, multiple power-generating cells are connected to form a stack. Independent measurements of each cell require multi-channel measurements of DC voltage, DC current, temperature and other parameters. The LR8400-20 Series comes with 30 channels as standard, which can be expanded to 60 channels. ■ Maximum rated voltage to earth: 300 V AC/DC ■ High withstand voltage The HiLOGGER measures not only fuel cells, but also batteries for UPS (uninterruptible power supplies) devices used in buildings as well as batteries consisting of cells and packaging connected in stacks that require multi-point measurements. In such measurements, high voltage for the whole stack is applied between channel-to-channel and channel-to-ground. Only a measuring instrument with isolated inputs and high-capacity withstand voltage characteristics can endure this. ■ High-speed sampling In the development of automobiles such as electric vehicles (EV) and plug-in hybrid vehicles (PHV) that use motors for propulsion, abrupt changes in load need to be measured. This makes the multi-channel, high-speed 10 ms sampling capability of the LR8400-20 Series an indispensable feature. ■ Maximum rated voltage between each channels of UNIVERSAL UNIT: 300 V DC ■ Maximum rated voltage between each channels of VOLTAGE/TEMP UNIT: 250 V DC 3 Highlights Multimeasurements Measure and record: ■ Temperature & humidity ■ A variety of transducer outputs (DC voltage) ■ Resistance values Also comes with high withstand voltage; isolated inputs required when measuring and recording battery cell voltages Voltage measurement (DC only) • 30 input channels Note: The LR8400-20, LR8401-20 and LR8402-20 models differ in the combination of input functions and terminals. • All input channels are isolated Note: Maximum rated voltage above ground between the HiLOGGER and analog inputs is 300 V AC/DC. Note: Maximum channel-tochannel voltage is a high voltage of 300 V DC. (Maximum voltage for models with M3 screw input terminals is 250 V DC.) Temperature & humidity measurement Temperature & resistance measurement • Temperature measurements of thermocouples on 30 channels • M3 screw terminal inputs enable secure connection of even thin thermocouples • Special sensor permits humidity measurements on 30 channels (optional Z2000) • Universal inputs support temperature measurements using Platinum resistance temperature sensor (Pt100/ JPt100), or resistance measurements (four wires) Note: The sensor power supply is the M3 mm dia. screw terminal block on the left side. Note: Both universal input terminals and M3 mm dia. input terminals enable humidity measurements. Note: These cannot be measured using the M3 screw input terminals units. Note: Supports resistance recording to enable assessment of changes in resistance in the device under test. 4-terminal method, measurement resolution 0.5 mΩ -, testing current 1 mA To record 4 - 20mA instrumentation signals, attach a commercially available 250Ω shunt resistance to the input terminals (between + and -) to convert the signals to 1 - 5 V. Then use the 1-5V or the 10V f.s. input range in the HiLOGGER. ■ A compact A4 size enhances mobility A compact A4 size footprint makes it ideal for use in virtually any environment. ■ Helps also in collecting automotive data Ideal for testing and collecting data on the vibration characteristics of automotive parts Pulse totalization measurement • 8 channel inputs (pulse and digital input selectable for Pulse rotations measurement Logical 1-0 measurement • 8 channel inputs (pulse and digital input selectable for • 8 channel inputs (digital and pulse input selectable for • For measuring energy consumption and cumulative flow • For measuring rotational irregularities of motors and drills • The input signal shares common • The input signal shares common • 1 or 0 is recorded for each recording interval • The input signal shares common Note: M3 screw input terminals provide direct connection Note: M3 screw input terminals provide simple connection Note: M3 screw input terminals provide simple connection each channel) ground with the HiLOGGER each channel) ground with the HiLOGGER each channel) ground with the HiLOGGER 4 Accurately capture any phenomena you want to measure Highlights ■ 10 ms high-speed sampling High-speed Recording Sampling at 100 ms intervals cannot capture abrupt load changes Sampling the same waveform at ten times the speed, at 10 ms intervals, accurately captures the changes. Highlights The development of hybrid and electric automobiles requires instruments that can measure abrupt load changes. Channels 1 to 15 provide 10-ms sampling and channels 16 to 30 provide 20-ms sampling. This channels allow you to track waveforms not possible with earlier models. Note: Measurements on channels 31 to 60 provide 50-ms sampling. ■ Enhanced noise suppression A digital oversampling filter function reduces inverter switching noise and 50/60 Hz hum noise, a concern in earlier models, during recording. Noise suppression Note: The noise reduction effect improves with longer recording intervals (i.e., at slower sampling speeds). Without electric noise reduction, you will obtain a waveform like the one above in temperature measurements of an electromagnetic cooker Highlights Easy-toview LCD A digital filter in the HiLOGGER eliminates high-frequency noise to enable accurate temperature waveforms ■ 5.7 inch TFT LCD display is easy to view even at an angle The LCD has a wider visual angle and is larger (5.7 inches, 640 × 480 dots) than the STN LCD in our previous model (8420-51s) to facilitate observation of waveforms on multiple channels. 5 Store data securely for more than 1 year ■ Compatible with USB memory devices Highlights For even greater convenience, the HiLOGGER now provides support for USB memory devices. Measurements can now immediately be written to a USB memory device in real-time. USB memory devices are also a handy means to transfer data to a PC. Storage Media Note: Although USB memory devices enable real-time saving of data, for more reliable data protection we recommend use of HIOKI CF cards, which are guaranteed to work with the instrument, for real-time saving of data. ■ Saving data to CompactFlash (CF) card Use only HIOKI CF cards, which are manufactured to strict industrial standards, for long-term storage of important data. Note: Operation of non-HIOKI CF cards is not guaranteed ■ Recording Capacity Note: Use only HIOKI CF cards that are guaranteed to operate with the HiLOGGER for continuous long-term recording. Recording of 30 analog channels only (no pulse measurement, alarm output or waveform processing data) Recording intervals Internal memory (16 MB) 10 ms 46m For 15 or fewer analog channels Model 9727 (256 MB) 12h 25m Model 9728 (512 MB) 1d 00h 51m Model 9729 (1 GB) 2d 01h 42m Model 9830 (2 GB) 4d 03h 25m 20 ms For 30 or fewer analog channels 1h 33m 1d 00h 51m 2d 01h 42m 4d 03h 25m 8d 06h 50m 50ms 3h 53m 2d 14h 08m 5d 04h 16m 10d 08h 33m 20d 17h 06m 100ms 7h 46m 5d 04h 16m 10d 08h 33m 20d 17h 06m 41d 10h 12m 200ms 15h 32m 10d 08h 33m 20d 17h 06m 41d 10h 12m 82d 20h 24m 500ms 1d 14h 50m 25d 21h 22m 51d 18h 45m 103d 13h 30m 207d 03h 01m 1s 3d 05h 40m 51d 18h 45m 103d 13h 30m 207d 03h 01m 414d 06h 03m 2s 6d 11h 20m 103d 13h 30m 207d 03h 01m 414d 06h 03m "★" 5s 16d 04h 21m 258d 21h 47m 517d 19h 34m "★" "★" 10s 32d 08h 43m 517d 19h 34m "★" "★" "★" 20s 64d 17h 26m "★" "★" "★" "★" 30s 97d 02h 10m "★" "★" "★" "★" 1min 194d 04h 20m "★" "★" "★" "★" 2min 388d 08h 40m "★" "★" "★" "★" 5min to 1hour "★" "★" "★" "★" "★" • Maximum recording time is inversely proportional to number of recording channels. • Because the actual capacity of a CF card is less than that indicated, and because the header portion of waveform files is not included in capacity calculations, expect actual maximum times to be about 90% of those in the table. • "★" exceeds 1 year. Highlights Replacing cards ■ Cards can be replaced during real-time recording This function has been provided to enable removal of cards during recording to allow the user to analyze the data recorded so far. This makes it possible to replace USB memory devices and CF cards during real-time recording without having to stop measurements. Note: During high-speed recording, be sure to insert the new storage media within 2 minutes of removing a card. 6 A host of useful functions and features VOLTAGE/TEMP UNIT LR8500 ● 15ch ● M3 screw terminals (2 terminals per channel) UNIVERSAL UNIT LR8501 ● 15ch ● Push-button type terminals (4 terminals per channel) Function highlights Easy installation ■ Up to two additional 15 channel input units can be added The need for more measurement channels can be met even after purchasing the instrument. The instrument comes with 30 channels as standard, but another two 15 channel input units can be added to expand the total number of channels to 60. Note: The units provided with the unit as standard cannot be removed. Function highlights Ease of use ■ Input setting screens with waveform monitoring The HiLOGGER adopts the setting screens that earned its sister model (8430-20) a reputation for user-friendliness. Range settings, warnings, triggers, waveform processing and other measurement input settings can be taken in at a glance. 7 Function highlights ■ Alarm output The HiLOGGER outputs a signal when alarm criteria are satisfied and also sounds a buzzer. Four systems are provided as standard and separate criteria can be set for each input source enabling OR and AND criteria between channels. Alarm output Note: Open-collector output (5 V voltage output and relay drive capacity 5 to 30 V, 200 mA) Function highlights Weathers power outages ■ Trickle charging the internal battery An internal battery (optional accessory) is charged when the AC adapter is connected. Since the internal battery will automatically take over in the event of a sudden power outage, it permits uninterruptible operation. Function highlights ■ Protection of files being stored on external storage media An internal high-capacity capacitor will provide enough power to store any data at risk on a CF card or USB memory device should a sudden power outage occur during long-term storage. This reduces the risk of data loss and corruption of the file system. Measurements will resume as soon as the power returns. ■ Real-time processing functions The HiLOGGER comes with [four arithmetic operation] functions for processing between channels. Data processed in real-time can be displayed in graph form. In addition, processing results for 30 channels are stored in internal memory and can be handled as data for independent input channels. Calculation Functions ■ Records average values every 30 minutes The HiLOGGER contains a [time-span processing] function. The instrument will save processing data as text data for a preset time period in real-time. Function highlights ■ Simultaneous recording to storage media and PC Measurement data can be simultaneously saved to external storage media and a hard disk on a PC connected to a network to reduce the risk data loss. USB / LAN Communication USB LAN ■ USB and LAN connection for easy setup The supplied Logger Utility software allows you to set up the logger from a PC. Setup could not be easier. Just follow the numbered procedures to set up the instrument. Note: Data on an inserted CF card can be copied to a PC via USB connection. Note: The Logger Utility will enable LAN access with software Ver. 1.20 or later. 8 Bundled user-friendly software for PC analysis Function highlights PC Measurement ■ The supplied Logger Utility software enables processing of measurement data on a PC ■ View past data during recording ■ Output PC data to a printer ■ Control of measurements from a PC screen Connect the PC to the HiLOGGER using USB or via LAN* (see note). Use the supplied Logger Utility software to record data on a PC in real-time. Scroll backwards through the displayed trend graph window to view past waveforms even while recording. Up to five HiLOGGERs can be connected to one PC. ■ Analyze after measuring Our new “dual-knob function” greatly simplifies data analysis. Two separate waveform windows are provided, with the displayed waveforms showing different time-axis scales (time bases). This capability substantially simplifies long-term data analysis. (Patent pending) Entire Recording Length: 1 s/div Segment A 50 ms/div magnification Segment A View Segment B 100 ms/div magnification Segment B View Spans entire recording length ■ Remote control through HTTP server function* Without the need to install additional software, you can use an ordinary web browser on your PC to set up the HiLOGGER, acquire data and monitor data on the screen. ■ Data acquisition via FTP* FTP allows the PC to acquire files stored on HiLOGGER storage devices or measurement data in internal memory. ■ Data transfer via FTP* Data saved in real-time to storage media can be automatically transferred to an FTP server started from the PC either at regular intervals during measurements or when measurements end. *Note: LAN communication functions support planned from software Ver. 1.20. ■ Be informed via E-mail* Your PC or mobile device is notified of storage media full, internal memory full, stop trigger invoked, alarm occurrence and other events via E-mail. 9 ■ Product Specifications General specifications (product and accuracy guaranteed for one year) Internal memory Internal clock Accuracy of timebase Backup battery Operating temp. & humidity 16 Mega-bytes (8M data points) Auto calendar, Precision ±3 s/ day (at 23 °C/ 73 °F) ±0.2s/ day on measurement (at 23 °C/ 73 °F) For clock and setting conditions: battery life 5 years (at 23 °C/ 73 °F) Dimensions & Mass Graph time axis 100 ms/ div to 1 day/ div (21 selections) Recording Time Enable continuous recording ON (records until the Stop key is pressed), or continuous recording OFF (enable a specified time span) (sampling period) charging: 10 °C/ 50 °F to 40 °C/ 104 °F) External trigger input, Trigger output, 4 channel alarm outputs, +12 V/ 100 mA max. output, GND Approx. 272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR8400 main unit, except the Battery Pack 370 g/ 13.1 oz) Approx. 272 mm (10.71 in) W × 234.8 mm (9.24 in) H × 66.5 mm (2.62 in) D, 2.6 kg (91.7 oz), (LR8500 × 2 and LR8400 × 1, except the Battery Pack 370 g/ 13.1 oz) Accessories Recording Intervals 10 ms*1, 20 ms*2, 50 ms*3, 100 ms to 1 hr (19 selections) Note: All input channels are scanned at high speed during every recording interval *1 Thermocouple burn-out detection OFF, and using up to 15 channels *2 Thermocouple burn-out detection OFF, and using up to 30 channels, or Thermocouple burn-out detection ON, and using up to 15 channels *3 Thermocouple burn-out detection OFF, and using up to 60 channels, or Thermocouple burn-out detection ON, and using up to 30 channels 0 °C (32 °F) to 40 °C (104 °F), 80 % rh or less (non-condensating, when Storage temp. & -10 °C (14 °F) to 60 °C (140 °F), 80 % rh or less, (non-condensating) humidity Conforming standards Safety : EN61010-1, EMC : EN61326-1, EN61000-3-2, EN61000-3-3 JIS D1601: 1995 5.3 (1) Corresponds to Class 1: a passenger car, Anti-vibration Condition: class A External control terminal Measurement Settings Detailed operating manual ×1, Measurement guide ×1, AC ADAPTER 941815 ×1, USB cable ×1, CD-R (data collection software "Logger Utility") ×1 (ON/OFF) Enable to repeat recording after the specified recording Repeating Recording time span has elapsed Data Saving Select a CF card or USB memory (Use only PC Cards sold by HIOKI) Auto: Save waveform data or time divided calculation results in real time Storage operation Manual: Push the save key (operation select: item choose/ directly save) Possible: Waveforms are saved approximately one minute as binary or CSV Storage media Real-time saving Data storage media CF card USB memory CF card slot ×1, HIOKI 9727 (256 MB), 9728 (512 MB), 9729 (1 GB), 9830 (2 GB), Data format: FAT, FAT32 Series A receptacle Communication function IEEE 802.3 Ethernet 100BASE-TX, DHCP, DNS capable • Data acquisition, condition settings used with the Logger Utility software (supplied as standard) • Use the communication command to set and measure (ver. 1.20 or later) • Data download via FTP server function (stored in the CF card or the USB memory) • Automatically transmit data via FTP client function • Remote control via HTTP server function • Send mail function via E-mail system USB 2.0 High-speed capable, series mini-B receptacle • Data acquisition, condition settings used with the Logger Utility USB communication software (supplied as standard) interface • Configure the unit and measure using communication commands • Transfer data from the CF card to a PC via USB drive mode (data LAN interface transfer not possible from USB memory sticks) Display section Display device LCD Brightness 5.7 inch TFT color liquid crystal display (640 × 480 pixel), horizontal 15 division, vertical 10 division, selectable between English and Japanese displays, Back light saver available Selectable from 100, 70, 40, or 25 % Power supplies AC Power DC Power External Using the AC ADAPTER 9418-15 (supplied as standard, 100 to 240 VAC, 50/60 Hz), Power consumption: 7 VA (with battery pack removed and maximum brightness) Using the BATTERY PACK Z1000 (optional accessory, AC adapter has priority when used in combination with battery pack) Continuous operation time: 5 hours (at 23 °C, LCD brightness 25 %) Fast recharging time: 3 hours (using the AC adapter and main unit to recharge the battery, at 23 °C, reference value) 10 to 28 VDC (Rechargable voltage 12 to 16 VDC, Please contact your HIOKI distributor for connection cord) Maximum rated power: 24 VA (at 16 VDC external power supply, battery charge, LCD brightness 100 %) Trigger functions Trigger mode, timing Analog signal source Pulse signal source Digital signal source Timer trigger Trigger output Modes : Single / Repeat, Timing : Start / Stop / Start & Stop, Logical sum (OR) and product (AND) of each trigger source, Selectable for each channel Configure each individual channel for 30 channels or up to 60 channels depending on number of additional terminal modules installed. [Level trigger] Triggers when rising or falling through preset level [Window] Triggers when entering or exiting range defined by preset upper and lower limit values 8 channels of pulse totalizer inputs [Level trigger] Triggers when rising or falling through preset level [Window] Triggers when entering or exiting range defined by preset upper and lower limit values 8 channels of digital signal inputs [Logic pattern trigger] agreement (or disagreement) in the specified [1/ 0/ ×] pattern Set up for year/ month/ day/ hour/ minute/ second Open collector (active low, with 5 V output, at least 10 ms pulse width), M3 mm screw terminal Alarm output Number of channels 4 channels, non-isolated (common ground with chassis) 60 channels of analog input, 8 channels of pulse totalizer inputs or Alarm source digital inputs, Thermocouple burn-out detection Level, Window, Logic pattern, Output latch/ no latch, Cancel alarm Alarm type while measuring Buzzer, ON/OFF possible Alarm sound Open collector (active low, with 5 V output), M3 mm screw terminal, Alarm output Output refreshed at every recording interval Output sink current 200 mA at 5 V to 30 VDC Note: Setting is independent from the recording interval Divided saving Delete & save Interruptions during saving data to the CF card or the USB memory (if sampling rate is slower than 1 minute, waveforms are saved at each interval) To the PC: Waveforms are saved to the HDD in the PC via LAN or USB communication when used with the Logger Utility Software. Data can be saved in real time to the CF card or USB memory at the same time. Simple divide: Save waveform data at pre-set times into separate files from the time measurement starts. On schedule: Designate a reference time within 24 hours and save data into separate files at every set time interval starting from the reference time. Endless loop saving: New file overwrites the oldest file when the CF card or USB memory capacity runs short Storage media may be removed during real-time save after message confirmation. Upon inserting the storage media again, data saved in internal memory during that time will be saved as a separate file in the media. Possible: When a power failure occurs during real-time save, the file close sequence is completed before the unit is shut down. When powering with batteries and low battery power is detected, the file close sequence will automatically be executed. Data protect Saved data types Loading data Setting condition, Waveform data (binary or text style), Calculation of numerical value, Screen data (compressed BMP) Stored binary data can be recalled by the HiLOGGER in 16 MB quantities Calculation function Numerical value calculations Data range of calculation Calculation value save Waveform calculations No. 1 to 6, maximum 6 calculations can be conducted simultaneously Selections: average value, peak value, maximum value, time at maximum value, minimum value, time at minimum value During measurement or after stopping: Store all data or data between A and B cursors into internal memory Times: Calculate values at pre-determined 1 sec to 1 day intervals and display the latest value Possible: After measuring the last calculated value is automatically saved to the CF card or USB memory as a text file Timed save: Save calculated data at pre-determined 1 sec to 1 day intervals as text data to the CF card or USB memory in real time. *4 arithmetic calculations between each channel *Separate display of calculation graphs (only during measurement) and input waveforms *Real-time save of calculation graph data Other functions Event marking A-B cursor Scaling Rate adjustment Comment input Other Search: Move to the event number entered and display the waveforms appearing before and after event Number of events: Maximum 100 per measurement Measurement: time difference between A and B, electric potential difference, electric potential of A or B and time Type: Trace the data, amplitude axis, time axis Convert and display the measurement value of each channel as a scaled value Scaling can be set for a channel so that its value is the same as that for UNIT1-CH1 Enter a title or a comment for each channel Start backup, save ten types setting conditions into main unit, auto set up, start/stop key lock, key-lock, beep sound Pulse, Digital input (digital / pulse selectable for each channel, M3 screw terminal Number of channels 8×channels, 8ch, 2 terminals per channel, not isolated, common ground) No-voltage 'a' contact (normally open contact), open collector or Input condition voltage input, Input resistance: 1.1 MΩ Max. allowable input 0 V to 50 VDC (maximum voltage between input terminals that does not cause damage) Max. rated voltage Not isolated (common ground) between channels Max. rated voltage to earth Not isolated (common ground) 2 selectable levels (H: over 1.0 V, L: 0 - 0.5 V), (H: over 4.0 V, L: 0 - 1.5 V) Detect level With filter OFF: 200 μs or more (both H and L periods must be at least 100 μs) Pulse input period With filter ON: 100 ms or more (both H and L periods must be at least 50 ms) Rising or falling edge can be set for each channel Slope Totalized pulses: Integrated (pulse count integration from start), Pulse measurement Instantaneous (pulse count value at each sampling, and integrated value is reset each time) mode Rotation count: Count input pulses during one second For contact bound resistant (ON/OFF set for each channels) Filter Measurement parameters Ranges Finest Resolution Range of Measurements 1,000 M (pulse) f.s. 1 (pulse) 0 to 1,000 M (pulse) Pulse totalization 5,000/n (r/s) f.s. 1/n (r/s) 0 to 5,000/n (r/s) Pulse rotations "n" above is the number of sensor output pulses per rotation, 1 to 1,000 Digital input Record logical "1" or "0" at each sampling 10 ■ Product Specifications Analog input section (@23 ±5˚C/73 ±9˚F, 30 to 80% rh., from 30 minutes after power on) Voltage Setting Ranges Resolution Measurement range 10 mV f.s. 500 nV -10 mV to 10 mV 20 mV f.s. 1 μV -20 mV to 20 mV 100 mV f.s. 5 μV -100 mV to 100 mV 200 mV f.s. 10 μV -200 mV to 200 mV 1 V f.s. 50 μV -1 V to 1 V 2 V f.s. 100 μV -2 V to 2 V 10 V f.s. 500 μV -10 V to 10 V 20 V f.s. 1 mV -20 V to 20 V 100 V f.s. 5 mV -100 V to 100 V 1 − 5 V f.s. 500 μV 1 V to 5 V Temperature Thermocouples (Compliance standard) (Excluding standard reference contact accuracy) 500 ˚C f.s. 0.01 ˚C 0.05 ˚C K 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C J 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C E 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C T N Measurement range -100 to less than 0 ˚C 0 to 100 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 500 ˚C -200 to less than -100 ˚C -100 to 1350 ˚C -100 to less than 0 ˚C 0 to 100 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 500 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 1200 ˚C -100 to less than 0 ˚C 0 to 100 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 500 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 1000 ˚C -100 to less than 0 ˚C 0 to 100 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 400 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 400 ˚C -100 to less than 0 ˚C 0 to 100 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 500 ˚C -200 to less than -100 ˚C -100 to less than 0 ˚C 0 to 1300 ˚C Thermocouple Setting Ranges Resolution 100 ˚C f.s. 500 ˚C f.s. 0.01 ˚C 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 500 ˚C f.s. 0.01 ˚C 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 500 ˚C f.s. 2000 ˚C f.s. 0.01 ˚C 0.05 ˚C 0.1 ˚C R S K, J, E, T, N, R, S, B : JIS C1602-1995, IEC 584 W : ASTME-988-96 Thermocouple Setting Ranges Resolution 100 ˚C f.s. Accuracy ±10 μV ±20 μV ±100 μV ±200 μV ±1 mV ±2 mV ±10 mV ±20 mV ±100 mV ±10 mV Accuracy ±0.8 ˚C ±0.6 ˚C ±1.5 ˚C ±0.8 ˚C ±0.6 ˚C ±1.5 ˚C ±0.8 ˚C ±0.8 ˚C ±0.6 ˚C ±1.0 ˚C ±0.8 ˚C ±0.6 ˚C ±1.0 ˚C ±0.8 ˚C ±0.6 ˚C ±0.8 ˚C ±0.6 ˚C ±1.0 ˚C ±0.8 ˚C ±0.6 ˚C ±1.0 ˚C ±0.8 ˚C ±0.6 ˚C ±0.8 ˚C ±0.6 ˚C ±1.5 ˚C ±0.8 ˚C ±0.6 ˚C ±1.5 ˚C ±0.8 ˚C ±0.6 ˚C ±1.2 ˚C ±1.0 ˚C ±2.2 ˚C ±1.2 ˚C ±1.0 ˚C ±2.2 ˚C ±1.2 ˚C ±1.0 ˚C B W Measurement range 0 to 100 ˚C 0 to less than 100 ˚C 100 to less than 300 ˚C 300 to 500 ˚C 0 to less than 100 ˚C 100 to less than 300 ˚C 300 to 1700 ˚C 0 to 100 ˚C 0 to less than 100 ˚C 100 to less than 300 ˚C 300 to 500 ˚C 0 to less than 100 ˚C 100 to less than 300 ˚C 300 to 1700 ˚C 400 to less than 600 ˚C 600 to less than 1000 ˚C 1000 to 1800 ˚C 0 to 100 ˚C 0 to 500 ˚C 0 to 2000 ˚C Accuracy ±4.5 ˚C ±4.5 ˚C ±3.0 ˚C ±2.2 ˚C ±4.5 ˚C ±3.0 ˚C ±2.2 ˚C ±4.5 ˚C ±4.5 ˚C ±3.0 ˚C ±2.2 ˚C ±4.5 ˚C ±3.0 ˚C ±2.2 ˚C ±5.5 ˚C ±3.8 ˚C ±2.5 ˚C ±1.8 ˚C ±1.8 ˚C ±1.8 ˚C Other specifications about thermocouple measurement Reference junction compensation Internal/ External, at INT RJC, total accuracy = add ± 0.5 ˚C Thermocouple burn-out detection ON/ OFF, detect at each sampling (when slower than 20 ms) (Compliance standard) Temperature Platinum Pt 100 : JIS C1604-1997, IEC 751, JPt 100 : JIS C1604-1989 resistance temperature sensor Types Setting Ranges Resolution 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C 100 ˚C f.s. 0.01 ˚C 500 ˚C f.s. 0.05 ˚C 2000 ˚C f.s. 0.1 ˚C Measurement range -100 to 100 ˚C -200 to 500 ˚C -200 to 800 ˚C -100 to 100 ˚C -200 to 500 ˚C -200 to 500 ˚C Accuracy ±0.6 ˚C ±0.8 ˚C ±1.0 ˚C ±0.6 ˚C ±0.8 ˚C ±1.0 ˚C Resistance /testing current 1 mA Resolution 10 Ω f.s. 0.5 mΩ 20 Ω f.s. 1 mΩ 100 Ω f.s. 5 mΩ 200 Ω f.s. 10 mΩ Measurement range 0 to 10 Ω 0 to 20 Ω 0 to 100 Ω 0 to 200 Ω Accuracy ±10 mΩ ±20 mΩ ±100 mΩ ±200 mΩ Humidity (use sensor Z2000) Resolution 100 %rh f.s. 0.1 %rh Measurement range 5.0 to 95.0 %rh Refer to table below Pt 100 JPt 100 Accuracy n Humidity sensor Z2000 accuracy Filter function (Thermocouple/ Resistance temperature sensor/ Voltage/ Resistance/ Humidity) Digital filter Select OFF/ 50 Hz/ 60 Hz (In order to remove harmonic components, during analog input the cut-off frequency is automatically set according to the sampling rate) ■ Optional Product Specifications UNIVERSAL UNIT LR8501 (product and accuracy guaranteed for one year) VOLTAGE/TEMP UNIT LR8500 (product and accuracy guaranteed for one year) Number of input channels Measurement parameters Input conditions Number of input channels 15 channels (input type selectable from voltage, thermocouple, humidity, for each channel), M3 screw terminals (2 terminals per channel) Isolated from each other channels and from chassis Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W) Humidity with the sensor Z2000 Measurement parameters Input resistance: 1 MΩ (at voltage/ thermocouple measurement) Max. rating: ±100 V DC (max. voltage between input terminals without damage) Input conditions Max. rated voltage between 250 V DC (max. voltage between input channel terminals) isolated input channels Max. rated voltage from 300 V AC, DC (max. voltage from terminals to chassis ground without damage) isolated terminals to ground Measurement accuracy Refer to MEMORY HiLOGGER main unit specifications Approx. 128 mm (5.04 in) W × 52.8 mm (2.08 in) H × 64.5 mm (2.54 in) Dimensions & Mass D, 380 g (13.4 oz) 15 channels (input type selectable from voltage, thermocouple, Pt 100/ JPt 100, humidity, resistance, for each channel), Push-button type terminals (4 terminals per channel) Isolated from each other channels and from chassis Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W) Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/ 4-wired, testing current 1 mA) Resistance (4-wired, testing current 1 mA) Humidity with the sensor Z2000 Input resistance: 1 MΩ (at voltage/ thermocouple measurement), 2 MΩ (at platinum resistance temperature sensor, or resistance measurement) Max. rating: ±100 V DC (max. voltage between input terminals without damage) Max. rated voltage between 300 V DC (max. voltage between input channel terminals) isolated input channels 300 V AC, DC (max. voltage from terminals to chassis ground without damage) Max. rated voltage from Caution: Not isolated from each other and common GND at resistance isolated terminals to ground temperature sensor or resistance measurement input Measurement accuracy Refer to MEMORY HiLOGGER main unit specifications Approx. 128 mm (5.04 in) W × 52.8 mm (2.08 in) H × 64.5 mm (2.54 in) Dimensions & Mass D, 300 g (10.6 oz) 11 Model Line-up Items Specifications Model LR8400-20 (with built-in VOLTAGE/TEMP UNIT × 2) Built-in 30 channels (Isolated from each other channels and chassis) [UNIT-1, UNIT-2] M3 screw terminals × 30 channels (2 terminals per channel) Expandable by adding 30 more channels for a total of 60 input channels Analog input Caution: Built-in M3 screw terminal units cannot be removed or replaced M3 screw terminals × 15 (optional input unit, Model LR8500 or LR8501, up to 2 units) Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W) Measurement parameters Humidity with the sensor Z2000 Input resistance 1 MΩ (at voltage/ thermocouple measurement) Max. allowable input ±100 V DC (max. voltage between input terminals without damage) Max. rated voltage between isolated input channels 250 V DC (max. voltage between input channel terminals) Max. rated voltage from isolated terminals to ground 300 V AC, DC (max. voltage from terminals to chassis ground without damage) Items Specifications Model LR8401-20 (with built-in UNIVERSAL UNIT × 2) Built-in 30 channels (Isolated from each other channels and chassis) [UNIT-1, UNIT-2] Push-button type terminals × 30 channels (4 terminals per channel) Expandable by adding 30 more channels for a total of 60 input channels Analog input Caution: Built-in push-button terminal units cannot be removed or replaced Push-button type terminals × 15 (optional input unit, Model LR8500 or LR8501, up to 2 units) Max. allowable input Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W) Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/ 4-wired, testing current 1 mA) Resistance (4-wired, testing current 1 mA) Humidity with the sensor Z2000 1 MΩ (at voltage/ thermocouple measurement) 2 MΩ (at resistance temperature sensor, or resistance measurement) ±100 V DC (max. voltage between input terminals without damage) Max. rated voltage between isolated input channels 300 V DC (max. voltage between input channel terminals) Max. rated voltage from isolated terminals to ground 300 V AC, DC (max. voltage from terminals to chassis ground without damage) Caution: Not isolated from each other and common GND at resistance temperature sensor or resistance measurement input Measurement parameters Input resistance Items Specifications Expandable by adding 30 more channels for a total of 60 input channels (optional input unit, Model LR8500 or LR8501, up to 2 units) Measurement parameters Input resistance Max. allowable input Push-button type terminals × 15 Model LR8402-20 (with built-in UNIVERSAL UNIT × 1, VOLTAGE/TEMP UNIT × 1) Built-in 30 channels (Isolated from each other channels and chassis) [UNIT-1] Push-button type terminals × 15 channels (4 terminals per channel) [UNIT-2] M3 screw terminals × 15 channels (2 terminals per channel) Analog input Max. rated voltage between isolated input channels M3 screw terminals × 15 Caution: Built-in push-button terminal unit and M3 screw terminal unit cannot be removed or replaced Voltage, Temperature with thermocouples (K, J, E, T, N, R, S, B, W), Humidity with the sensor Z2000 [UNIT-1 side only] Platinum resistance temperature sensor (Pt 100, JPt 100, 3-wired/ 4-wired), Resistance (4-wired) 1 MΩ (at voltage/ thermocouple measurement) 2 MΩ (at platinum resistance temperature sensor, or resistance measurement) ±100 V DC (max. voltage between input terminals without damage) 250 V DC at M3 screw terminals, 300 V DC at push-button type terminals Push-button type terminals × 15 M3 screw terminals × 15 (max. voltage between input channel terminals) Max. rated voltage from isolated 300 V AC, DC (max. voltage from terminals to chassis ground without damage) terminals to ground Caution: Not isolated from each other and common GND at resistance temperature sensor or resistance measurement input ■ Bundled software specifications Logger Utility (bundled application software) Operating environment One CD-R, CPU: Pentium 3 (500 MHz or more), at least 512 MB of memory Interface: USB, LAN (LAN not available with the Model 8430-20/-21) OS: Windows 2000 (SP4 or later)/ XP (SP2 or later)/ Vista (32-bit/ 64-bit), (Ver 1.50 or later) Windows 7 (32-bit/ 64-bit) Data conversion Target data: Real-time data acquisition file (LUW format), Record to internal memory data (MEM format), Waveform processing data Converted sections: All data, designation section Format: CSV format (separate by comma, space, tab), transfer to EXCEL spreadsheet, arbitrary data thinning Parameter calculations Target data: Real-time data acquisition file (LUW format), Record to internal memory data (MEM format), Data acquired in real time, Waveform processing data Calculation items: average, peak, maximum values, time to maximum values, minimum values, time to minimum values, ON time, OFF time, count the number of ON time and OFF time, standard deviation, integration, area values, totalization Search function Target data: Real-time data acquisition file (LUW format), Record to internal memory data (MEM format), Waveform processing data, Search mode: event mark, time and date, maximum position, minimum position, maximum pole, minimum pole, alarm position, level, window, amount of change (This software is compatible only to the MEMORY HiLOGGER LR8400-20s, LR8400-21s, 8423, 8430-20/-21) Measurements on multiple loggers connected by LAN* or USB can be controlled to sequentially acquire, display and save waveform data (for recording up to 10 million samples) *LAN available with HiLOGGER main unit Ver 1.20 or later Real-time data acquisition Data acquisition settings Number of controllable instruments: up to 5 units Display: Waveforms (multiple time axis can be displayed), Numerical values (logging), Alarm status at the same time, Numerical value monitoring in a separate window, Waveform scroll while measuring Data saving destination: Real-time data transfer to EXCEL (new function), or Real-time data acquisition file (LUW format, only for HIOKI) Event marks: can be applied while recording Data acquisition settings for the HiLOGGER Saving: The setting for multiple HiLOGGERs can be saved together in one file (LUS format); Instrument configuration settings can be sent and received Processed data file: Real-time data acquisition file (LUW format), Record to internal memory data (MEM format) Display format: Simultaneously display waveform and numerical value, Waveform display Print function (time-axis divided display possible) Maximum number of channels: 300 channerls (measurement data, used with the LR8400-20s, LR8400-21s) + 60 channels (waveform processing data) Others: Waveform display on sheet for each channel, scroll, record event mark, cursor, hard copy, numerical value display Supported printer: printer compatible with the OS Target data: Real-time data acquisition file (LUW format), Record to internal memory data (MEM format), Waveform processing data Print format: waveform image, report format, list print (channel settings, event, cursor value) Print area: the entire area, area between cursors A and B Print preview: supported Waveform processing Processing items: Four arithmetic operations Number of processing channels: 60 channerls Main units and Options in Detail LR8400-20 (with built-in VOLTAGE/TEMP UNIT × 2) Built-in units are equivalent to the VOLTAGE/TEMP UNIT LR8500 (15 ch) × 2 Caution: Built-in units cannot be removed or changed LR8401-20 (with built-in UNIVERSAL UNIT × 2) Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 2 Caution: Built-in units cannot be removed or changed LR8402-20 (with built-in UNIVERSAL UNIT × 1, VOLTAGE/TEMP UNIT × 1) Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 1, and VOLTAGE/TEMP UNIT LR8500 (15 ch) × 1 Caution: Built-in units cannot be removed or changed Measurement and input options VOLTAGE/TEMP UNIT LR8500 2 terminals M-3 mm screw type, 15 channels Voltage, Temperature with thermocouple, or Humidity measurement UNIVERSAL UNIT LR8501 HUMIDITY SENSOR Z2000 4 terminals push-button type, 15 channels Voltage, Temperature with thermocouple, Platinum Resistance temperature sensor, Humidity, or Resistance measurement Removable storage (CF card) 3 m (9.84 ft) length Power supplies PC communication Supplied with PC Card adapter PC CARD 2G 9830 (2 GB capacity) PC CARD 1G 9729 PC Card Precaution Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. (1 GB capacity) Charges while installed in the HiLOGGER PC CARD 512M 9728 (512 MB capacity) BATTERY PACK Z1000 PC CARD 256M 9727 NiMH, Charges while installed (256 MB capacity) LAN CABLE 9642 AC ADAPTER 9418-15 Supplied as standard, 100 to 240 V AC Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length Cases CARRYING CASE C1000 FIXED STAND Z5000 Includes compartment for options For wall hanging and slanted bench mounting Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 http://www.hioki.cn / E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected] DISTRIBUTED BY Beijing Office : TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] HIOKI INDIA PRIVATE LIMITED : Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India TEL +91-731-4223901, 4223902 FAX +91-731-4223903 http://www.hioki.in / E-mail: [email protected] All information correct as of Jul. 13, 2010. All specifications are subject to change without notice. LR8400-20E4-07M-00K Printed in Japan