MEMORY HiCORDER 8807-01,8808-01 Recorders New Concept with Detachable Printer * Photo shows the 8808-01 with optional printer unit installed. Compact Size Recorder with Color Display The MEMORY HiCORDERs 8807-01/8808 -01, housed in a B5 book-sized, compact, and thin body weighing in at under 1.2 kg, are handy high-speed recorders equipped with features such as analog 4-channel (8807-01: 2-channel) isolated inputs, PC card slot, RS-232C communication, 3-way power supply, and powerful trigger functions. One unit is capable of covering a variety of usages, ranging from low-speed/long-term continuous recording to recording of highspeed transients. Enhanced Model with Harmonic Analysis Function ... 8808-51 To the MEMORY HiCORDERs 8807 -01 /8808 -01 with their popular detachable printers, HIOKI has added the MEMORY HiCORDERs 8808-51 with harmonic analysis function. Capable of both instantaneous analysis and time series analysis of harmonics, these units can measure and analyze harmonic current flowing into and out of a commercial power system, as well as harmonic components piggybacking on power line voltage. Note) The waveform recording functions of the MEMORY HiCORDER 8808-51 is identical to those of the 8808-01 model. For details on specifications those concerning the harmonic wave analysis functions, refer to the catalog for the MEMORY HiCORDER 8808-51. 2 Recording Intermittent Leakage, Engine Performance and Relay Timing -Application ExamplesUnpredictable intermittent leakage is monitored unattended by recording instantaneous waveforms of the leakage current and line voltage 8807+8992 9199 Leak current (CH1) 9198 Trigger point Line voltage (CH2) 9094 3283 For long-term monitoring, use the AC ADAPTER 9418-15 for the MEMORY HiCORDER 8807-01 and the AC ADAPTER 9445-02/-03 for the CLAMP ON LEAK HiTESTER 3283 e r lin r powe Monito lities ! anoma Recording of leakage is triggered when the input exceeds preset upper or lower limits. Every time a leakage phenomenon occurs, the waveforms can be printed out or the data saved on an ATA card. Data saved on a flash ATA card can be read back by the 8807-01 for analysis of peak current values at breaker trip time using the cursor function. Analysis of engine characteristics Analysis of Sequence Control Device Faults Allows the balance between boost, oil pressure, air fuel ratio, ignition timing, engine speed, injector aperture, etc., to be observed and recorded as waveforms. Circuit breaker timing measurement close command Phase R Phase S Phase T Circuit breaker cut-off in a power circuit can be investigated by analyzing the relationship of multipoint logic signals to the analog waveform. Up to eight channels are provided for recording relay operation using logic probes. Use the model 9320-01 for non-voltage contact signals, and the LOGIC PROBE 9321-01 with isolated inputs for powered AC relay signals. Abnormal halts and warnings issued by sequence control devices in manufacturing production and testing lines can be caused by AC power hits or low voltage. Such anomalous behavior can best be analyzed by setting the sequence relay signal as a trigger to record the abnormal AC power waveforms and DC voltage systems. Recording of motor rush current Motor power-on inrush current waveforms can be precisely recorded. The CLAMP ON PROBE s model 9018 -10 and 9132 -10 are available for current measurement, as is the CLAMP ON LEAK HiTESTER 3283. In addition, to measure direct current waveforms, a variety of sensors such as the UNIVERSAL CLAMP ON CTs model 9277, 9278 and 9279 are available upon request. 3 High-Speed Response for Capturing Transient Events - Memory recorder function - CH 1 Input voltage The input signal is converted*1 to digital data that are stored in the internal memory. The data can then be displayed on the screen or printed out on paper*2. Once recorded, data are backed up for five years by the internal battery, provided that the start button is not pressed a second time (trigger mode: oneshot). The necessary parts can be searched out on the screen so that only the required waveforms are printed out*2. *1 The data sampling speed (sampling rate) is automatically set at 1/80 of the time axis range. E.g., at 200 µs/division the sampling rate is 2.5 µs, at 5 minutes/division, the sampling rate becomes 3.75 sec. A/D conversion Display on color LCD Insulation High-speed writing to internal memory A/D conversion CH 4 Input voltage Storage on PC card Transmission via RS-232C Insulation Printing on thermal printer (option) High-speed sampling of analog waveforms Input voltage Operation of the memory recorder functions Sampling period *2 The optional PRINTER UNIT 8992 is required. Waveform data Time ■ Example of abnormal waveform recording Waveform captured using the voltage-drop detection trigger. This allows recording of the waveforms of momentary voltage drops in power lines. Trigger functions capable of monitoring all 4 channels*3 For all of the measurement functions, including recorder and memory recorder, triggers can be set on all 4 analog input channels and the 8 logic input channels. In addition to a simple level trigger based on comparison with a single voltage value, the following trigger conditions are also available: ● Window in/out trigger based on comparison of 2 voltage values ● Voltage drop trigger for AC power lines*4 ● RMS level trigger based on rms values*5 ● Waveform judgment trigger*4 monitoring the waveforms of AC power lines in real-time ● Pattern trigger monitoring the ON/OFF condition of a logic signal * MEMORY HiCORDER 8808-01. 2 channels in the case of the MEMORY HiCORDER 8807-01. *4 Memory recorder function only. For 50/60 Hz only. *5 RMS recorder function only. For 50/60 Hz only. 3 1-channel setting 256 kW/ch 3200 divisions Sampling period Time axis 200μs/DIV 2.5 μs 640 ms 160 ms 400μs/DIV 5 μs 1.28 s 320 ms 1ms/DIV 12.5 μs 3.2 s 800 ms 2ms/DIV 25 μs 6.4 s 1.6 s 5ms/DIV 62.5 μs 16 s 4s 10ms/DIV 125 μs 32 s 8s 20ms/DIV 250 μs 1m 4s 16 s 50ms/DIV 625 μs 2 m 40 s 40 s 100ms/DIV 1.25 ms 5 m 20 s 1 m 20 s 200ms/DIV 2.5 ms 10 m 40 s 2 m 40 s 500ms/DIV 6.25 ms 26 m 40 s 6 m 40 s 1s/DIV 12.5 ms 53 m 20 s 13 m 20 s 2s/DIV 25 ms 1 h 46 m 40 s 26 m 40 s 5s/DIV 62.5 ms 4 h 26 m 40 s 1 h 6 m 40 s 8 h 53 m 20 s 2 h 13 m 20 s 6 h 40 m 10s/DIV 125 ms 30s/DIV 375 ms 1 day 2 h 40 m 1min/DIV 750 ms 2 days 5 h 20 m 13 h 20 m 2min/DIV 1.5 s 4 days 10 h 40 m 1 day 2 h 40 m 5min/DIV 3.75 s 11 days 2 h 40 m 2 days 18 h 40 m Level crossing External trigger Analog CH1-2 Logic A-B Level, RMS level trigger Sag Momentary stop Impulse Manual trigger Trigger source AND / OR Window out Window in Analog CH3-4* *8808 only Timer trigger Window in/out trigger Drop Momentary stop Sag Pattern comparison Impulse Voltage drop trigger Real-time waveform judgement trigger 4-channel setting 64 kW/ch 800 divisions Real-time waveform judgement trigger Logic pattern trigger ■ Real-time wave f orm judgement trigger with const ant monitoring of the voltage waveforms of AC power lines (Memory recorder function only)*6 The waveform judgement trigger constantly monitors the AC power line for irregular waveforms. There are two ways to use this trigger. One cycle of measured waveforms is observed with the judgement area automatically created from the immediately preceding cycle waveform, or the judgement area can be automatically created from the ideal sine wave. In both cases, the trigger activates when the signal is detected to move outside the reference area. This allows real-time monitoring of phenomena in AC power lines that existing level triggers have not been able to capture, such as momentary stops, sags, and impulses. The level trigger can be set separately for each analog channel. Also, when the printer is connected, the judgment area automatically generated from the ideal sine wave can be printed as an overlay with the measurement waveform. *6 The time axis can be used for all ranges above 10 ms/DIV (version 2.20 or later). 4 - RMS Recorder, Recorder functions - RMS recorder function This function is exclusively for use on 50/60 Hz power-supply lines and DC. High-speed sampling is applied to calculate the rms value from the waveform data*1, and the result is recorded as a graph. *1 Using 250 µs high-speed sampling, data for three waveforms are captured for calculating the rms value. This process is repeated 800 times per second using the moving average method, resulting in high-speed response. Chart of Recorder function 100 V power line waveform Chart of RMS recorder function Slow-speed recording by RMS recorder ■ RMS Recorder & Memory function If an abnormal event is detected by triggers during real-time recording of signals using the RMS recorder, it is stored in memory by the highspeed sampling memory recorder. The RMS recorder function works independently and never stops. This function is highly convenient when it is desirable to record both abnormal phenomena and normal level fluctuations. High-speed recording by memory Recorder function operation The input signal is converted to digital form and displayed or printed*2 in real-time. The chart speed is maximum 10 mm/s (in the 1s/division range)*3. Even with the real-time recording, the last 400 divisions of the waveform can be observed by scrolling or reprinting the data*2. Recording paper 400 DIV divisions in memory *2 The optional 8992 PRINTER UNIT is required. *3 Only when using the AC Adapter. When using batteries, the maximum speed is 5 mm/s (2 s/division range). Recorder recording time Time axis ■ X-Y Recorder format This function allows two signals converted to digital form to be combined in an x-y plot and stored in memory. Any of the four analog channels can be used for an x-y plot, but only one plot can be combined. The X-Y plot can be viewed in real-time on the display, and there is no limit on the recording time. The waveforms can also be printed out as many times as desired. Display Y input X-Y matrix memory X input X-Y recorder diagram Actual operation conditions are assumed, and it is assumed that 30 cm of the length of the recording paper is not used, for a total of 1770 divisions Chart speed Approximate recording time with one roll of recording paper (18 m) Sampling period 100 ms/DIV 200 ms/DIV Stored in memory only : 2.5 μs Stored in memory only : 1 m 20 s AC Adapter used 10 mm/sec 2.5 μs AC Adapter used : 500 ms/DIV 1 s/DIV 2 s/DIV 40 s Printer not required Stored in memory only : 3 m 20 s 5 mm/sec 2.5 μs 59 m 2 h 27 m 30 s 5 s/DIV 2 mm/sec 2.5 μs 10 s/DIV 1 mm/sec 2.5 μs 4 h 55 m 30 s/DIV 20 mm/min 2.5 μs 14 h 45 m 1 min/DIV 10 mm/min 2.5 μs 2 min/DIV 5 mm/min 2.5 μs 2 days 11 h 6 days 3 h 30 m 1 day 5 h 30 m 5 min/DIV 2 mm/min 2.5 μs 10 min/DIV 1 mm/min 2.5 μs 12 days 7 h 30 min/DIV 20 mm/hour 2.5 μs 36 days 21 h 1 h/DIV 10 mm/hour 2.5 μs 73 days 18 h 29 m 30 s 5 - Data Communication with PC, other functions - Off-Line Data Exchange with a PC Waveforms acquired by the memory recorder can be stored on flash ATA-PC cards. Stored waveform data can be converted to text (CSV) format files by the supplied Wv Waveform Viewer PC application program. ■ Waveform Viewer software Measurement data can be saved in binary format. Also, can be converted to text format for numerical analysis in a PC spreadsheet program. Data can be saved in binary or text formats. The binary format is for data to be used in the MEMORY HiCORDERs 8807-01 and 8808-01. Data saved to the PC in binary format can be converted to text format using the supplied Wv (Waveform Viewer program), for loading into a spreadsheet program such as Excel. ■ Display copy in BMP format Displayed images can be saved in BMP format to easily create and print color reports from the PC’s word processor. Example showing measurement data imported to Excel. Convenient features for ease of operation Convenient features such as the DMM function, special range for a clamp probe, numerical value calculation, scaling, A/B cursor measurement, free comment input, and automatic restart after power outage make the measurement work quick and simple. ■ DMM Function Digital Multi Meter functions are provided for simple input voltage checking. Selectable modes are Effective value mode (AC+DC), and Instantaneous value mode (DC), each displaying four numeric digits. When the scaling function is enabled, the specified scaling value is incorporated. Note: Convenient for checking waveform recordings of power lines. RMS display is for 50/60 Hz or DC only. ■ Special range for clamp probe enables easy current measurement *1 Using the CLAMP ON PROBE 9018-10, current waveforms can be captured on live lines. Voltage range settings and scale settings are performed with a one-touch operation thanks to the special clamp probe range provided. *1 Only compatible with the CLAMP ON PROBEs model 9018-10 and 9132-10. The CLAMP ON PROBEs model 9018 and 9132 can be connected using the CONVERSION ADAPTER 9199. CLAMP ON PROBE 9018-10 Connects Directly 10 − 500 A f.s. (BNC plug) 40 Hz − 3 kHz 9018-50 Output 0.2 V f.s. CLAMP ON PROBE 9132-10 20 − 1000 A f.s. 40 Hz − 1 kHz Output 0.2 V f.s. 9018 CONVERSION ADAPTER 9199 (receiving-end banana/BNC output) ■ RS-232C connection to PC The PC and HiCORDER can be directly connected serially for transferring recorded data and remote settings. The software created by the user may be used on the PC. Connects Indirectly (Banana plugs) 6 -SpecificationsBasic specifications Measurement functions Input type and number of channels Maximum sampling rate Memory capacity External memory Battery backup External control Interface Environment (no condensation) (MEMORY HiCORDER 8807-01, 8808-01) (1) Memory recorder, (2) Recorder, (3) RMS recorder & memory (50/60 Hz/ or DC only) 8807-01: fixed input section, 2 analog + 8 logic, 8808-01: fixed input section 4 analog + 8 logic Isolated analog channels, isolated input and outputs, logic has common GND. 400 k sample/s (2.5 µs cycle) Simultaneous sampling for 2/4 analog + 8 logic channels 8807-01: (analog 12 bits + logic 4 bits) × 256 kilo-words/ channel (CH1) to (analog 12 bits + logic 4 bits) × 128 kilowords/channel (CH1, CH2) 8808-01: (analog 12 bits + logic 4 bits) × 256 kilo-words/ channel (CH1) to (analog 12 bits + logic 4 bits) × 64 kilo-words/ channel (CH1 - CH4) PC card TYPE II slot × 1: flash ATA card (max. 1GB), MS-DOS format Memory contents: Setting conditions, measurement data (binary, text), image data (BMP), calculation results (figures) Clock, waveform data, settings, battery life approx. 5 years (at 25 ˚C/ 77 ˚F) Terminal block: trigger input/output RS-232C interface: 9-pin round connector terminal (the optional RS-232C CABLE 9612 is required for connection to PC) *1 Note: These LR6/AA alkaline batteries cannot be used with the PRINTER UNIT 8992. 200 µs to 5 minutes/division, 19 settings, time axis zoom ×2 to ×10; 3 settings, compression 1/2 to 1/500; 8 settings Time axis Sampling period 1/80 of time axis ranges (minimum sampling period 2.5 µs) Recording length 20 to 3200*3 divisions *3 Depending on the number of channels in use. Pre-trigger Can record data from before the trigger point, 0 to 100 % or -95 % of recording length; 15 settings Other functions Numerical calculations, logging (numerical printout), X-Y waveform plot (one plot on the 8807-01, up to three plots on the 8808-01), voltage axis zoom ×2 to ×10; 3 settings, compression 1/2 Recorder function 100 ms*4 to 1 hr/division; 14 settings, 1 division = 80 samples, time axis compression 1/2 to 1/50; 5 settings *4 100 ms to 500 ms/division ranges shown only on display when using AC Adapter. 100 Time axis ms to 1 s/division ranges shown only on display when using batteries 2.5 µs fixed 20 to 400 divisions, "continuous"*5 Recording length *5 only “continuous” for X-Y plotting X-Y sampling period 250 µs; fixed (dot), 500 µs to 10 ms (line) Sampling period 20 pixel/DIV (display), 80 pixels/DIV × 80 pixels/DIV (optional printer) X-Y axis resolution Printer interface: PRINTER UNIT 8992 can be connected (option) Operation: +5 ˚C/41 ˚F to +40 ˚C/104 ˚F, 35% to 80% relative humidity. Storage: -10 ˚C/14 ˚F to +50 ˚C/122 ˚F, 35% to 80% relative humidity. Safety: EN61010 Applicable standards EMC: EN61326, EN61000-3-2, EN61000-3-3 Power requirements Memory function 100 to 240V AC (50/60 Hz) with use the optional AC ADAPTER 9418-15, or 9418-10, 15 VA max. (using printer) LR6 (AA) alkaline batteries × 6 (Continuous use 1 hours, cannot be used with the PRINTER UNIT 8992) BATTERY PACK 9447 (AC adapter has priority when used in combination with battery pack, fast recharge with AC adapter 2 hours, Continuous use 3 hours) 12 V Car battery (Please contact HIOKI for connection cord) Dimensions and mass 8807-01, 8808-01: 203 (7.99) W × 170 (6.69) H × 52 (2.05) D mm (inch) (printer detached) 8807-01, 8808-01: 280 (11.02) W × 170 (6.69) H × 52 (2.05) D mm (inch) (printer attached) 8807-01: 1.1 kg/ 38.80 oz (printer detached) 1.5 kg/ 52.91 oz (printer attached) 8808-01: 1.2 kg/ 42.33 oz (printer detached) 1.6 kg/ 56.44 oz (printer attached) Supplied accessories LR6/AA alkaline batteries ×6, alkaline battery box ×1, strap ×1, Application Disk (Wave Viewer Wv, Communication Commands table) × 1 Back-scroll of memory data (max. last 400 divisions) and reprinting of stored data (with/ optional printer), logging (numerical printout) (with/ optional printer), voltage axis magnification ×2 to ×10; 3 settings, compression 1/2; 1 setting. X-Y waveform plot (one plot on the 8807- Other functions 01, up to three plots on the 8808-01) RMS Recorder & Memory function (for 50/60 Hz and DC) RMS recorder: 100 ms to 1 hr/division; 14 settings Memory recorder: 200 µs to 20 ms/division; 7 settings Time axis 1 division = 80 samples, time axis compression 1/2 to 1/50; 5 settings Sampling period RMS recorder: 250 µs fixed (800 RMS data/second) Memory recorder: 1/80 of time axis range RMS calculation accuracy ±3% f.s. Recording length RMS recorder: 20 to 200 divisions, continuous Memory recorder: 20 to 400 divisions, OFF (only RMS recorder Other functions Back-scroll of memory data (max. last 200 divisions) and reprinting of stored data (with/ optional printer), for memory recorder: back-scroll of memory data (max. last 400 divisions) and reprinting of stored data (with/ optional printer), logging (numerical printout) (w/ optional printer), voltage axis magnification ×2 to ×10; 3 settings, compression 1/2; 1 setting. when OFF) Auxiliary function Recording and display *2 Waveform printing when the optional PRINTER UNIT 8992 is used. Display method 5.7-inch STN color LCD, with Japanese/English selector 240 × 320 dots *2Printer paper 112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll * Recording width 10 divisions in full scale, 1 division = 10mm (0.39in) (80pixels) * Paper feed density 8 rows/mm (203 rows/in) 2 2 *2Recording speed General Printing of settings including input range, trigger time, etc., cursor measurement, scaling, comment input, screen hard copy, start condition retention, auto setup, auto saving, remote control, autorange setting, list & gauge printing (with/ optional printer), DMM function (voltage shown as numerals on the display). Calculation functions Up to four arithmetic operations simultaneously Average value, effective (RMS) value, peak to peak value, maximum value, time to maximum value, minimum value, time to minimum value, period, and frequency, area, X-Y area. DMM function (measurement signal is DC, 50/60Hz only), or DC instantaneous value Display digits: 4 digits (last digit 0 to 4 is rounded zero, 5 to 9 is rounded five) Voltage range: Auto only (10 mV to 100 V/division, 5 settings) (Memory recorder) 16 rows/mm (406 rows/in) using the memory recorder's smooth print function. Max. 10 mm/s (0.39 inch/s) (when using AC Adapter), max. 5 mm/s (0.2 inch/s) (when using batteries) Display update rate: 1 s, display contents: AC+DC rms Trigger function Trigger source Analog input CH1 - CH4 (8807-01: CH1 - CH2), logic input A - B, external, timer, manual (either ON or OFF for each source), logical AND/OR of sources Trigger types (Analog) Level: Triggered when set voltage value is exceeded in UP or DOWN direction. Window in/out: When entering or exiting a level range defined by upper or lower limit Voltage drop: Only for AC 50/60 Hz power lines. Triggered when the peak voltage falls below setting value RMS level: Only for DC and AC 50/60 Hz power lines. Triggered when rms value crosses set value in UP or DOWN direction (RMS recorder function only) Real-time waveform judgment: Only for AC 50/60 Hz power lines. Trigger function that monitors when a signal exceeds the evaluation area (Memory recorder function only) Accuracy: ±3% rdg. ±5dgt. Analog input (accuracy at 23 ±5 ˚C/73 ±9 ˚F after 30 minutes warm-up time; accuracy guaranteed for 1 year) Input Terminal: isolated BNC Inter-channel and input-frame isolation Measurement range MEM or REC function: 10mV to 100V/DIV, 13 settings RMS recorder function: 5mV to 50V/DIV, 13 settings full-scale (f.s.) = 10 divisions, AC voltage for possible measurement / display using the memory function: 450 V AC rms, low-pass filter: 5/500 Hz, the measurement resolution is 1/160 of range 400 kS/s (simultaneous sampling of all channels) Level setting resolution 0.25% f.s., waveform judgment trigger only: 0.1% f.s. (f.s.=10 divisions) Maximum sampling rate Accuracy, frequency characteristics Input resistance and capacitance Input coupling Trigger types (Logic) Pattern trigger: 1, 0, or × (disregard), logical product (AND) or logical sum (OR) set for 4 channels V AC rms, DC Max. allowable input 450 (upper voltage which when applied to between input pins does not damage them) Trigger filter (analog/logic) 9 settings from 0.1 to 10.0 divisions or OFF (memory recorder) ON/ OFF (recorder) Max. rated voltage to earth ±0.5% f.s., DC to 50 kHz ±3 dB 1 MΩ, 7 pF approx. (at 100 kHz) DC, GND 450 V AC, DC (upper voltage which when applied to input channel casing or between input channels does not damage them) 7 ■ Appearance and Dimensions (8807-01 and 8808-01 Instrument-only) ■ Appearance and Dimensions (8807-01 and 8808-01 with printer attached) Logic probe terminal/for 9320-01 and 9321-01 RS-232C terminal/Mini DIN 9-pin 112 mm (4.4 inch) wide thermal printer (Detachable/option) PC card slot/Type II 170 mm (6.69 inch) 170 mm (6.69 inch) Waveform monitor (5.7 inch color STN LCD) Analog input (Isolated BNC terminal) 8807-01: 2 ch, 8808-01: 4 ch 203 mm (7.99 inch) Mass:(with 8992 printer attached) 8807-01: Approx. 1.5 kg/59.91 oz 8808-01: Approx. 1.6 kg/56.44 oz Screen contrast adjuster 52 mm (2.05 inch) External trigger input / output 52 mm (2.05 inch) 280 mm (11.02 inch) Mass: 8807-01: Approx. 1.1 kg/38.80 oz 8808-01: Approx. 1.2 kg/42.33 oz ■ Supplied accessory PC Software Specifications Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory) Battery compartment at the rear Functions • Quick display of waveform files • Text conversion: Conversion of binary data files to text format, with storage in either CSV or space/tab delimited format. Span specification and data culling available. • Display format settings: scroll function, enlarge/reduce display, display CH settings. • Other: Voltage trace function, jump to cursor/trigger position function, etc. Compatible operating systems Windows 2000/XP/Vista (32-bit), or Windows 7 (32-bit/64-bit) LR6/AA alkaline batteries × 6 or 9447 BATTERY PACK × 1 ■ Specifications of Options (sold separately) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) Note: The unit-side plug of the 9320-01 is different from the 9320. LOGIC PROBE 9320-01 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Function Detection of voltage signal or relay contact signal for High/Low state recording Input 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals), input impedance: 1MΩ (with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to +50V), pull-up resistance: 2kΩ (contact input: internally pulled up to +5V) Digital input threshold Contact input detection resistance Response speed 1.4V/2.5V/4.0V 1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open) and 1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short) 9320-01: 500ns or lower Max. allowable input 0 to +50V DC (the maximum voltage that can be applied across input pins without damage) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) Note: The unit-side plug of the 9321-01 is different from the 9321. LOGIC PROBE 9321-01 Function Input Output (H) detection Output (L) detection Response time (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Detection of AC or DC relay drive signal for High/Low state recording Can also be used for power line interruption detection 4 channels (isolated between unit and channels), HIGH/LOW range switching Input impedance: 100kΩ or higher (HIGH range), 30kΩ or higher (LOW range) 170 to 250V AC, ±DC (70 to 250V ) (HIGH range) 60 to 150V AC, ±DC (20 to 150V) (LOW range) 0 to 30V AC, ±DC (0 to 43V) (HIGH range) 0 to 10V AC, ±DC (0 to 15V) (LOW range) Rising edge 1ms max., falling edge 3ms max. (with HIGH range at 200V DC, LOW range at 100V DC) Maximum allowable 250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage) input voltage Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz) DIFFERENTIAL PROBE 9322 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) WAVE PROCESSOR 9335 For high-voltage floating measurement, power line surge noise detection, RMS rectified output measurement For waveform monitor output, frequency characteristics: DC to 10MHz (±3dB), amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3% of full scale (at max. 2000V DC) (full scale: 2000V DC) For detection of power line surge noise, frequency characteristics: 1kHz to 10MHz ±3dB Distribution media One CD-R Operating environment Computer equipped with Pentium (133 MHz) or better CPU and at least 32 MB of memory, Running under Windows 2000/XP/Vista (32-bit), or Windows 7 (32-bit/64- DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz to 100k Hz, response speed: 200ms or less (400V AC), accuracy: ±1% of full scale (DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000V AC) Display functions RMS mode Waveform display/X-Y display/digital value display/cursor function/ scroll function/maximum number of channels (32 channels analog, 32 channels logic)/gauge display (time, voltage axes)/graphical display File loading Input Input type: balanced differential input, input impedance/capacitance: H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth: when using grabber clip 1500V AC/DC (CAT II ), 600V AC/DC (CAT III), when using alligator clip: 1000V AC/DC (CAT II), 600V AC/DC (CAT III) Readable data formats (.MEM, .REC, .RMS, .POW) Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration) Data conversion Conversion to CSV format, tab delimited, space delimited/data culling (simple)/convert for specified channel/batch conversion of multiple files Print functions Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/ hard copy functions usable on any printer supported by operating system Other Parameter calculation/search/clipboard copy/launching of other applications Function DC mode AC mode Maximum allowable input voltage 2000V DC, 1000V AC (CAT II), 600V AC/DC (CAT III) Output Voltage divider for 1/1000 of input, BNC connectors (output switchable for 3 modes DC, AC, RMS) Power source Power terminal of the input units, or use with AC ADAPTER 9418-15 (DC 12V) bit) (recommended system: Pentium (200 MHz) or better with at least 64 MB of memory) Configuration of options Input cable for measurement use is not provided. Please purchase the optional cable. ALLIGATOR CLIP 9790-01 Red/black set attaches to the ends of test leads (9790) Voltage measurement Recommended Logic signal measurement GRABBER CLIP 9790-02 CONVERSION CABLE 9323 Red/black set attaches to the ends of test leads (9790) CONNECTION CORD 9790 (Thin Type) CAT II 300 V, ultraflexible 2.8 mm (0.11 in) diameter test lead cable, 1.5 m (4.92 ft) length Note: Attachment clips sold separately. LOGIC PROBE 9320-01 4-channel type, for voltage/contact signal ON/OFF detection (response time 0.5 µsec, miniature terminal type) CONTACT PIN 9790-03 Red/black set attaches to the ends of test leads (9790) Tip Expanders 9790-03 Tip Expanders 9790-01 Tip Expanders Attachment clips are sold separately from CONNECTION CORD 9790. Purchase the appropriate attachment clips for your application separately CONNECTION CORD 9198 CONNECTION CORD 9197 * Input cable for measurement use is not provided. Please purchase the optional cable. CLAMP ON PROBE 9132-50 UNIVERSAL CLAMP ON CT 9277 Enables observation of AC current waveforms. Input: 1 to 100kHz, selectable 20 and 200A rms ranges, 2V AC output Observe waveforms from DC to distorted AC. DC to 100kHz response, input 20A / output 2V AC For leakage current measurement, includes 10 mA to 200 A ranges, with analog output of 1 V f.s. DC, and waveform monitor output of 1 V f.s. AC at 40 Hz to 2 kHz. Requires the AC adapter 9445-02/-03 for use with power supply UNIVERSAL CLAMP ON CT 9278 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 200A / output 2V AC UNIVERSAL CLAMP Not CE marked ON CT 9279 Observe waveforms from DC to distorted AC. DC to 20kHz response, input 500A / output 2V AC AC ADAPTER 9445 -02/-03 With the 3283, continuous use. For USA, Canada: 9445-02, For EU: 9445-03. For powering Differential probe 9322, 100 to 240 V AC. For up to 2 kV DC or 1 kV AC. Use with the AC Adapter 9418-15, for power supply. CLAMP ON SENSOR 9272-10 CLAMP ON LEAK HiTESTER 3283 AC ADAPTER 9418-15 DIFFERENTIAL PROBE 9322 Current measurement *High precision type CLAMP ON PROBE 9018 -50 Enables observation of AC current waveforms. Input: 40 Hz to 1 kHz, selectable 20 to 1000 A ranges, Output: 0.2 V AC/ range For high voltage (up to 500 V), 1.8 m (5.91 ft) length High-Voltage measurement Current measurement *50/60 Hz line use Enables observation of AC current waveforms. Input: 40 Hz to 3 kHz, selectable 10 to 500 A ranges, Output: 0.2 V AC/ range MEMORY HiCORDER 8808 -01 (4 ch) For low voltage (up to 300 V), 1.7 m (5.58 ft) length 4 isolated channels, ON/OFF detection of AC/DC voltage (miniature terminal type) Recommended Tip Expanders 9790-02 Used for connecting the 9320/9321 and 8808 series MEMORY HiCORDERs, because the terminal shapes are different. * This cable is not required for the smallterminal types 9327, 9320-01, and 9321-01. LOGIC PROBE 9321-01 OUTPUT CORD 9094 Not CE marked MEMORY HiCORDER 8807-01 (2 ch) PT 9303 Insulation transformer, 400V or 200V AC input, 10V AC output, for AC power line measurement. Required along with the Conversion Adapter 9199. SENSOR UNIT 9555 -10 Required along with the 9199 adapter to connect the 3283 to the 8808 series. * Input cable for measurement use is not provided. Please purchase the optional cable. Power supply unit for the 9272 to the 9279 clamp sensors, for signal output 9217 is necessary. Current measurement *For Oscilloscope, wide-band frequency type PC Software 3274 3275 3273-50 3276 CLAMP ON PROBE 3273-50 WAVE PROCESSOR 9335 DC to 50MHz wideband response, mA-class current up to 30A rms Convert data, print and display waveforms. Windows 2000/XP/Vista (32-bit), Windows 7 (32-bit/64-bit) 3272 CLAMP ON PROBE 3274 DC to 10MHz wideband response, mA-class current up to 150A rms CLAMP ON PROBE 3275 Carrying case DC to 2MHz wideband response, mA-class current up to 500A rms CLAMP ON PROBE 3276 DC to 100MHz wideband response, mA-class current up to 30A rms CARRYING CASE 9648 Hard case type, for storing options 3269 POWER SUPPLY 3272 Connect and power up to one CLAMP ON PROBE to use in combination with the 8808 series. POWER SUPPLY 3269 Connect and power up to four CLAMP ON PROBEs to use in combination with the 8808 series. Power Supply *Sold separately CARRYING CASE 9391 Soft case type, for storing options. Holds more options than the 9648 hard case. BATTERY PACK 9447 7.2 V, 2400 mAh Printer options CHARGE STAND 9643 AC ADAPTER 9418-15 Independent of the 8808 series main unit, use with the AC ADAPTER 9418-15 to charge one Model 9447. Universal 100 to 240 V AC, 12 V DC/ 2.5 A output The units can be operated using the supplied LR6/ AA alkaline batteries but use of the optional AC ADAPTER 9418-15 or BATTERY PACK 9447 (the AC ADAPTER 9418-15 is necessary for recharging) is recommended. Manganese batteries cannot be used. Use of commercially available rechargeable batteries instead of the original battery pack may result in damage to the unit. Other options Removable storage (CF card) Supplied with PC Card adapter Not CE marked RECORDING PAPER 9234 112 mm (4.41 in) × 18 m (59.06 ft), 10 rolls set CONNECTION CORD 9217 CONNECTION CORD 9165 PRINTER UNIT 8992 Printing width 100 mm (3.94 in), used together with the 8807-01, 8808-01 main body Cord has insulated BNC connectors at both ends, and connects to insulated BNC connectors on input terminal. 1.7 m (5.58 ft) length. Cord has metallic BNC connectors at both ends, and connects to metallic BNC connectors. 1.5 m (4.92 ft) length. RS-232C CABLE 9612 Mini DIN 9-pin - Dsub 9-pin, Cable length 1.5 m (4.92 ft) length. Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. Not CE marked Paper width: 70 to 220 mm (2.76 to 8.66 in), using special-purpose AC adapter ................ Cannot be used PC Card Precaution Not CE marked PAPER WINDER 220H PC CARD 2G 9830 SPLITTER CT101A CONVERSION ADAPTER 9199 LINE For 100 V/ 15 A, convenient for Banana-to-BNC, use to connect to BNC measuring 100 V AC line current with terminal on Input Module clamp-on probe PC CARD 1G 9729 ............... (1 GB capacity) PC CARD 512M 9728 .......... (512 MB capacity) PC CARD 256M 9727 .......... (256 MB capacity) Combination example (1) Main unit with memory 256 kW Printer AC adapter Battery pack Input cable Combination example (2) Main unit with memory 256 kW Printer AC adapter Battery pack Input cable 4 ch + logic 8 ch Printer less 8808-01 × 1 Not use 9418-15 × 1 9447 × 1 9198 × 4 4 ch + logic 8 ch With Printer unit 8808-01 × 1 8992 × 1 9418-15 × 1 9447 × 1 9198 × 4 Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 http://www.hioki.cn / E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected] DISTRIBUTED BY Beijing Office : TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] HIOKI INDIA PRIVATE LIMITED : Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India TEL +91-731-4223901, 4223902 FAX +91-731-4223903 http://www.hioki.in / E-mail: [email protected] All information correct as of Jun. 29, 2010. All specifications are subject to change without notice. 8807-01E18-06E-00P Printed in Korea