MEMORY HiCORDER 8807-01, 8808-01

MEMORY HiCORDER 8807-01,8808-01
Recorders
New Concept with Detachable Printer
* Photo shows the 8808-01 with optional printer unit installed.
Compact Size Recorder with Color Display
The MEMORY HiCORDERs 8807-01/8808 -01, housed in a B5 book-sized,
compact, and thin body weighing in at under 1.2 kg, are handy high-speed
recorders equipped with features such as analog 4-channel (8807-01: 2-channel)
isolated inputs, PC card slot, RS-232C communication, 3-way power supply, and
powerful trigger functions. One unit is capable of covering a variety of usages,
ranging from low-speed/long-term continuous recording to recording of highspeed transients.
Enhanced Model with Harmonic Analysis Function ... 8808-51
To the MEMORY HiCORDERs 8807 -01 /8808 -01
with their popular detachable printers, HIOKI has added
the MEMORY HiCORDERs 8808-51 with harmonic
analysis function. Capable of both instantaneous analysis
and time series analysis of harmonics, these units can
measure and analyze harmonic current flowing into and
out of a commercial power system, as well as harmonic
components piggybacking on power line voltage.
Note) The waveform recording functions of the MEMORY HiCORDER 8808-51 is identical to those of the 8808-01 model. For details on specifications
those concerning the harmonic wave analysis functions, refer to the catalog for the MEMORY HiCORDER 8808-51.
2
Recording Intermittent Leakage, Engine Performance and Relay Timing
-Application ExamplesUnpredictable intermittent leakage is monitored unattended by recording instantaneous waveforms of the leakage current and line voltage
8807+8992
9199
Leak current (CH1)
9198
Trigger point
Line voltage (CH2)
9094
3283
For long-term monitoring, use the AC ADAPTER 9418-15 for the MEMORY
HiCORDER 8807-01 and the AC ADAPTER 9445-02/-03 for the CLAMP
ON LEAK HiTESTER 3283
e
r lin
r powe
Monito
lities !
anoma
Recording of leakage is
triggered when the input
exceeds preset upper or
lower limits.
Every time a leakage phenomenon
occurs, the waveforms can be
printed out or the data saved on an
ATA card.
Data saved on a flash ATA card
can be read back by the 8807-01
for analysis of peak current values
at breaker trip time using the
cursor function.
Analysis of engine characteristics
Analysis of Sequence Control Device Faults
Allows the balance between boost, oil pressure, air fuel
ratio, ignition timing, engine speed, injector aperture,
etc., to be observed and recorded as waveforms.
Circuit breaker timing measurement
close command
Phase R
Phase S
Phase T
Circuit breaker cut-off in a power circuit can be
investigated by analyzing the relationship of multipoint logic signals to the analog waveform. Up to eight
channels are provided for recording relay operation
using logic probes.
Use the model 9320-01 for non-voltage contact signals,
and the LOGIC PROBE 9321-01 with isolated inputs
for powered AC relay signals.
Abnormal halts and warnings issued by sequence
control devices in manufacturing production and
testing lines can be caused by AC power hits or
low voltage. Such anomalous behavior can best be
analyzed by setting the sequence relay signal as a
trigger to record the abnormal AC power waveforms
and DC voltage systems.
Recording of motor rush current
Motor power-on inrush current waveforms
can be precisely recorded. The CLAMP ON
PROBE s model 9018 -10 and 9132 -10 are
available for current measurement, as is the
CLAMP ON LEAK HiTESTER 3283.
In addition, to measure direct current waveforms,
a variety of sensors such as the UNIVERSAL
CLAMP ON CTs model 9277, 9278 and 9279
are available upon request.
3
High-Speed Response for Capturing Transient Events
- Memory recorder function -
CH 1
Input voltage
The input signal is converted*1 to digital data that are stored
in the internal memory. The data can then be displayed on
the screen or printed out on paper*2. Once recorded, data are
backed up for five years by the internal battery, provided that
the start button is not pressed a second time (trigger mode: oneshot). The necessary parts can be searched out on the screen so
that only the required waveforms are printed out*2.
*1 The data sampling speed (sampling rate) is automatically set at 1/80 of the
time axis range. E.g., at 200 µs/division the sampling rate is 2.5 µs, at 5
minutes/division, the sampling rate becomes 3.75 sec.
A/D
conversion
Display on color LCD
Insulation
High-speed writing
to internal memory
A/D
conversion
CH 4
Input voltage
Storage on PC card
Transmission via
RS-232C
Insulation
Printing on thermal printer
(option)
High-speed sampling of analog waveforms
Input voltage
Operation of the memory recorder functions
Sampling period
*2 The optional PRINTER UNIT 8992 is required.
Waveform data
Time
■ Example of abnormal
waveform recording
Waveform captured using the voltage-drop detection
trigger. This allows recording of the waveforms of
momentary voltage drops in power lines.
Trigger functions capable of monitoring all 4 channels*3
For all of the measurement functions, including recorder and
memory recorder, triggers can be set on all 4 analog input
channels and the 8 logic input channels. In addition to a simple
level trigger based on comparison with a single voltage value,
the following trigger conditions are also available:
● Window in/out trigger based on comparison of 2 voltage values
● Voltage drop trigger for AC power lines*4
● RMS level trigger based on rms values*5
● Waveform judgment trigger*4 monitoring the waveforms of AC power
lines in real-time
● Pattern trigger monitoring the ON/OFF condition of a logic signal
* MEMORY HiCORDER 8808-01. 2 channels in the case of the MEMORY HiCORDER 8807-01.
*4 Memory recorder function only. For 50/60 Hz only.
*5 RMS recorder function only. For 50/60 Hz only.
3
1-channel setting
256 kW/ch 3200 divisions
Sampling
period
Time axis
200μs/DIV
2.5 μs
640 ms
160 ms
400μs/DIV
5 μs
1.28 s
320 ms
1ms/DIV
12.5 μs
3.2 s
800 ms
2ms/DIV
25 μs
6.4 s
1.6 s
5ms/DIV
62.5 μs
16 s
4s
10ms/DIV
125 μs
32 s
8s
20ms/DIV
250 μs
1m 4s
16 s
50ms/DIV
625 μs
2 m 40 s
40 s
100ms/DIV
1.25 ms
5 m 20 s
1 m 20 s
200ms/DIV
2.5 ms
10 m 40 s
2 m 40 s
500ms/DIV
6.25 ms
26 m 40 s
6 m 40 s
1s/DIV
12.5 ms
53 m 20 s
13 m 20 s
2s/DIV
25 ms
1 h 46 m 40 s
26 m 40 s
5s/DIV
62.5 ms
4 h 26 m 40 s
1 h 6 m 40 s
8 h 53 m 20 s
2 h 13 m 20 s
6 h 40 m
10s/DIV
125 ms
30s/DIV
375 ms
1 day 2 h 40 m
1min/DIV
750 ms
2 days 5 h 20 m
13 h 20 m
2min/DIV
1.5 s
4 days 10 h 40 m
1 day 2 h 40 m
5min/DIV
3.75 s
11 days 2 h 40 m
2 days 18 h 40 m
Level crossing
External
trigger
Analog CH1-2
Logic A-B
Level, RMS level trigger
Sag
Momentary
stop
Impulse
Manual
trigger
Trigger source
AND / OR
Window out
Window in
Analog CH3-4*
*8808 only
Timer trigger
Window in/out trigger
Drop
Momentary stop
Sag
Pattern comparison
Impulse
Voltage drop trigger
Real-time waveform judgement trigger
4-channel setting
64 kW/ch 800 divisions
Real-time waveform
judgement trigger
Logic pattern trigger
■ Real-time wave f orm judgement trigger with const ant
monitoring of the voltage waveforms of AC power lines
(Memory recorder function only)*6
The waveform judgement trigger constantly monitors the AC power
line for irregular waveforms. There are two ways to use this trigger.
One cycle of measured waveforms is observed with the judgement area
automatically created from the immediately preceding cycle waveform, or
the judgement area can be automatically created from the ideal sine wave.
In both cases, the trigger activates when the signal is detected to move
outside the reference area. This allows real-time monitoring of phenomena
in AC power lines that existing level triggers have not been able to
capture, such as momentary stops, sags, and impulses.
The level trigger can be set separately for each analog channel.
Also, when the printer is connected, the judgment area automatically
generated from the ideal sine wave can be printed as an overlay with the
measurement waveform.
*6 The time axis can be used for all ranges above 10 ms/DIV (version 2.20 or later).
4
- RMS Recorder, Recorder functions -
RMS recorder function
This function is exclusively for use on 50/60 Hz power-supply
lines and DC. High-speed sampling is applied to calculate the
rms value from the waveform data*1, and the result is recorded
as a graph.
*1 Using 250 µs high-speed sampling, data for three waveforms are captured for
calculating the rms value. This process is repeated 800 times per second using
the moving average method, resulting in high-speed response.
Chart of Recorder function
100 V power line
waveform
Chart of RMS recorder function
Slow-speed recording by RMS recorder
■ RMS Recorder & Memory function
If an abnormal event is detected by triggers during real-time recording
of signals using the RMS recorder, it is stored in memory by the highspeed sampling memory recorder. The RMS recorder function works
independently and never stops. This function is highly convenient when
it is desirable to record both abnormal phenomena and normal level
fluctuations.
High-speed recording by memory
Recorder function operation
The input signal is converted to digital form and displayed or
printed*2 in real-time. The chart speed is maximum 10 mm/s
(in the 1s/division range)*3. Even with the real-time recording,
the last 400 divisions of the waveform can be observed by
scrolling or reprinting the data*2.
Recording paper
400 DIV
divisions
in memory
*2 The optional 8992 PRINTER UNIT is required.
*3 Only when using the AC Adapter. When using batteries, the maximum speed is
5 mm/s (2 s/division range).
Recorder recording time
Time axis
■ X-Y Recorder format
This function allows two signals converted to digital form to
be combined in an x-y plot and stored in memory. Any of the
four analog channels can be used for an x-y plot, but only one
plot can be combined. The X-Y plot can be viewed in real-time
on the display, and there is no limit on the recording time. The
waveforms can also be printed out as many times as desired.
Display
Y input
X-Y matrix
memory
X input
X-Y recorder diagram
Actual operation conditions are assumed, and it is assumed that 30 cm of the
length of the recording paper is not used, for a total of 1770 divisions
Chart speed
Approximate recording time with one roll
of recording paper (18 m)
Sampling
period
100 ms/DIV
200 ms/DIV
Stored in memory only :
2.5 μs
Stored in memory only : 1 m 20 s
AC Adapter used 10 mm/sec
2.5 μs
AC Adapter used :
500 ms/DIV
1 s/DIV
2 s/DIV
40 s
Printer not required
Stored in memory only : 3 m 20 s
5 mm/sec
2.5 μs
59 m
2 h 27 m 30 s
5 s/DIV
2 mm/sec
2.5 μs
10 s/DIV
1 mm/sec
2.5 μs
4 h 55 m
30 s/DIV
20 mm/min
2.5 μs
14 h 45 m
1 min/DIV
10 mm/min
2.5 μs
2 min/DIV
5 mm/min
2.5 μs
2 days 11 h
6 days 3 h 30 m
1 day 5 h 30 m
5 min/DIV
2 mm/min
2.5 μs
10 min/DIV
1 mm/min
2.5 μs
12 days 7 h
30 min/DIV
20 mm/hour
2.5 μs
36 days 21 h
1 h/DIV
10 mm/hour
2.5 μs
73 days 18 h
29 m 30 s
5
- Data Communication with PC, other functions -
Off-Line Data Exchange with a PC
Waveforms acquired by the memory recorder can be stored on
flash ATA-PC cards. Stored waveform data can be converted to
text (CSV) format files by the supplied Wv Waveform Viewer
PC application program.
■ Waveform Viewer software
Measurement data can be saved in binary format. Also,
can be converted to text format for numerical analysis in a
PC spreadsheet program.
Data can be saved in binary or text formats. The binary format is for
data to be used in the MEMORY HiCORDERs 8807-01 and 8808-01.
Data saved to the PC in binary format can be converted to text format
using the supplied Wv (Waveform Viewer program), for loading into a
spreadsheet program such as Excel.
■ Display copy in BMP format
Displayed images can be saved in BMP format to
easily create and print color reports from the PC’s word
processor.
Example showing measurement data imported to Excel.
Convenient features for ease of operation
Convenient features such as the DMM function, special range
for a clamp probe, numerical value calculation, scaling, A/B
cursor measurement, free comment input, and automatic restart
after power outage make the measurement work quick and
simple.
■ DMM Function
Digital Multi Meter functions are provided
for simple input voltage checking. Selectable
modes are Effective value mode (AC+DC),
and Instantaneous value mode (DC), each
displaying four numeric digits. When the scaling
function is enabled, the specified scaling value is
incorporated.
Note: Convenient for checking waveform recordings of
power lines. RMS display is for 50/60 Hz or DC only.
■ Special range for clamp probe enables easy current measurement *1
Using the CLAMP ON PROBE 9018-10, current waveforms
can be captured on live lines. Voltage range settings and
scale settings are performed with a one-touch operation
thanks to the special clamp probe range provided.
*1 Only compatible with the CLAMP ON PROBEs model 9018-10 and
9132-10.
The CLAMP ON PROBEs model 9018 and 9132 can be connected
using the CONVERSION ADAPTER 9199.
CLAMP ON PROBE 9018-10
Connects Directly
10 − 500 A f.s.
(BNC plug) 40 Hz − 3 kHz
9018-50
Output 0.2 V f.s.
CLAMP ON PROBE 9132-10
20 − 1000 A f.s.
40 Hz − 1 kHz
Output 0.2 V f.s.
9018
CONVERSION ADAPTER 9199
(receiving-end banana/BNC output)
■ RS-232C connection to PC
The PC and HiCORDER can be directly connected serially for transferring
recorded data and remote settings. The software created by the user may be
used on the PC.
Connects Indirectly
(Banana plugs)
6
-SpecificationsBasic specifications
Measurement
functions
Input type and
number of channels
Maximum sampling
rate
Memory capacity
External memory
Battery backup
External control
Interface
Environment
(no condensation)
(MEMORY HiCORDER 8807-01, 8808-01)
(1) Memory recorder, (2) Recorder,
(3) RMS recorder & memory (50/60 Hz/ or DC only)
8807-01: fixed input section, 2 analog + 8 logic,
8808-01: fixed input section 4 analog + 8 logic
Isolated analog channels, isolated input and outputs, logic has common
GND.
400 k sample/s (2.5 µs cycle)
Simultaneous sampling for 2/4 analog + 8 logic channels
8807-01: (analog 12 bits + logic 4 bits) × 256 kilo-words/
channel (CH1) to (analog 12 bits + logic 4 bits) × 128 kilowords/channel (CH1, CH2)
8808-01: (analog 12 bits + logic 4 bits) × 256 kilo-words/
channel (CH1) to (analog 12 bits + logic 4 bits) × 64 kilo-words/
channel (CH1 - CH4)
PC card TYPE II slot × 1: flash ATA card (max. 1GB), MS-DOS
format
Memory contents: Setting conditions, measurement data (binary,
text), image data (BMP), calculation results (figures)
Clock, waveform data, settings, battery life approx. 5 years (at 25 ˚C/ 77 ˚F)
Terminal block: trigger input/output
RS-232C interface: 9-pin round connector terminal
(the optional RS-232C CABLE 9612 is required for connection to PC)
*1 Note: These LR6/AA
alkaline batteries cannot be
used with the PRINTER UNIT
8992.
200 µs to 5 minutes/division, 19 settings, time axis zoom
×2 to ×10; 3 settings, compression 1/2 to 1/500; 8 settings
Time axis
Sampling period
1/80 of time axis ranges (minimum sampling period 2.5 µs)
Recording length
20 to 3200*3 divisions
*3 Depending on the number of channels in use.
Pre-trigger
Can record data from before the trigger point, 0 to 100 %
or -95 % of recording length; 15 settings
Other functions
Numerical calculations, logging (numerical printout), X-Y waveform
plot (one plot on the 8807-01, up to three plots on the 8808-01), voltage
axis zoom ×2 to ×10; 3 settings, compression 1/2
Recorder function
100 ms*4 to 1 hr/division; 14 settings, 1 division = 80 samples,
time axis compression 1/2 to 1/50; 5 settings
*4 100 ms to 500 ms/division ranges shown only on display when using AC Adapter. 100
Time axis
ms to 1 s/division ranges shown only on display when using batteries
2.5 µs fixed
20 to 400 divisions, "continuous"*5
Recording length
*5 only “continuous” for X-Y plotting
X-Y sampling period 250 µs; fixed (dot), 500 µs to 10 ms (line)
Sampling period
20 pixel/DIV (display), 80 pixels/DIV × 80 pixels/DIV (optional printer)
X-Y axis resolution
Printer interface: PRINTER UNIT 8992 can be connected (option)
Operation: +5 ˚C/41 ˚F to +40 ˚C/104 ˚F, 35% to 80% relative humidity.
Storage: -10 ˚C/14 ˚F to +50 ˚C/122 ˚F, 35% to 80% relative humidity.
Safety: EN61010
Applicable standards
EMC: EN61326, EN61000-3-2, EN61000-3-3
Power
requirements
Memory function
100 to 240V AC (50/60 Hz) with use the optional AC ADAPTER 9418-15,
or 9418-10, 15 VA max. (using printer)
LR6 (AA) alkaline batteries × 6 (Continuous use 1 hours, cannot be used with
the PRINTER UNIT 8992)
BATTERY PACK 9447 (AC adapter has priority when used in combination
with battery pack, fast recharge with AC adapter 2 hours, Continuous use 3
hours)
12 V Car battery (Please contact HIOKI for connection cord)
Dimensions and
mass
8807-01, 8808-01: 203 (7.99) W × 170 (6.69) H × 52 (2.05) D mm (inch) (printer
detached)
8807-01, 8808-01: 280 (11.02) W × 170 (6.69) H × 52 (2.05) D mm (inch) (printer
attached)
8807-01: 1.1 kg/ 38.80 oz (printer detached) 1.5 kg/ 52.91 oz (printer attached)
8808-01: 1.2 kg/ 42.33 oz (printer detached) 1.6 kg/ 56.44 oz (printer attached)
Supplied accessories
LR6/AA alkaline batteries ×6, alkaline battery box ×1, strap ×1,
Application Disk (Wave Viewer Wv, Communication Commands table) × 1
Back-scroll of memory data (max. last 400 divisions) and reprinting
of stored data (with/ optional printer), logging (numerical printout) (with/
optional printer), voltage axis magnification ×2 to ×10; 3 settings,
compression 1/2; 1 setting. X-Y waveform plot (one plot on the 8807-
Other functions
01, up to three plots on the 8808-01)
RMS Recorder & Memory function (for 50/60 Hz and DC)
RMS recorder: 100 ms to 1 hr/division; 14 settings
Memory recorder: 200 µs to 20 ms/division; 7 settings
Time axis
1 division = 80 samples, time axis compression 1/2 to 1/50; 5 settings
Sampling period
RMS recorder: 250 µs fixed (800 RMS data/second)
Memory recorder: 1/80 of time axis range
RMS calculation accuracy
±3% f.s.
Recording length
RMS recorder: 20 to 200 divisions, continuous
Memory recorder: 20 to 400 divisions, OFF (only RMS recorder
Other functions
Back-scroll of memory data (max. last 200 divisions) and reprinting of
stored data (with/ optional printer), for memory recorder: back-scroll of
memory data (max. last 400 divisions) and reprinting of stored data (with/
optional printer), logging (numerical printout) (w/ optional printer), voltage
axis magnification ×2 to ×10; 3 settings, compression 1/2; 1 setting.
when OFF)
Auxiliary function
Recording and display *2 Waveform printing when the optional PRINTER UNIT 8992 is used.
Display method
5.7-inch STN color LCD, with Japanese/English selector
240 × 320 dots
*2Printer paper
112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll
* Recording width
10 divisions in full scale, 1 division = 10mm (0.39in) (80pixels)
* Paper feed density
8 rows/mm (203 rows/in)
2
2
*2Recording speed
General
Printing of settings including input range, trigger time, etc., cursor
measurement, scaling, comment input, screen hard copy, start
condition retention, auto setup, auto saving, remote control, autorange setting, list & gauge printing (with/ optional printer), DMM
function (voltage shown as numerals on the display).
Calculation functions
Up to four arithmetic operations simultaneously
Average value, effective (RMS) value, peak to peak value, maximum
value, time to maximum value, minimum value, time to minimum value,
period, and frequency, area, X-Y area.
DMM function
(measurement signal is DC, 50/60Hz only), or DC instantaneous value
Display digits: 4 digits (last digit 0 to 4 is rounded zero, 5 to 9 is
rounded five)
Voltage range: Auto only (10 mV to 100 V/division, 5 settings)
(Memory recorder)
16 rows/mm (406 rows/in) using the memory recorder's smooth print function.
Max. 10 mm/s (0.39 inch/s) (when using AC Adapter),
max. 5 mm/s (0.2 inch/s) (when using batteries)
Display update rate: 1 s, display contents: AC+DC rms
Trigger function
Trigger source
Analog input CH1 - CH4 (8807-01: CH1 - CH2), logic input A - B,
external, timer, manual (either ON or OFF for each source), logical
AND/OR of sources
Trigger types
(Analog)
Level: Triggered when set voltage value is exceeded in UP or
DOWN direction.
Window in/out: When entering or exiting a level range defined
by upper or lower limit
Voltage drop: Only for AC 50/60 Hz power lines. Triggered
when the peak voltage falls below setting value
RMS level: Only for DC and AC 50/60 Hz power lines.
Triggered when rms value crosses set value in UP or DOWN
direction (RMS recorder function only)
Real-time waveform judgment: Only for AC 50/60 Hz power
lines. Trigger function that monitors when a signal exceeds the
evaluation area (Memory recorder function only)
Accuracy: ±3% rdg. ±5dgt.
Analog input
(accuracy at 23 ±5 ˚C/73 ±9 ˚F after 30 minutes warm-up time; accuracy guaranteed for 1 year)
Input
Terminal: isolated BNC Inter-channel and input-frame isolation
Measurement
range
MEM or REC function: 10mV to 100V/DIV, 13 settings
RMS recorder function: 5mV to 50V/DIV, 13 settings
full-scale (f.s.) = 10 divisions, AC voltage for possible measurement
/ display using the memory function: 450 V AC rms, low-pass filter:
5/500 Hz, the measurement resolution is 1/160 of range
400 kS/s (simultaneous sampling of all channels)
Level setting
resolution
0.25% f.s., waveform judgment trigger only: 0.1% f.s. (f.s.=10
divisions)
Maximum sampling rate
Accuracy, frequency
characteristics
Input resistance
and capacitance
Input coupling
Trigger types
(Logic)
Pattern trigger: 1, 0, or × (disregard), logical product (AND) or
logical sum (OR) set for 4 channels
V AC rms, DC
Max. allowable input 450
(upper voltage which when applied to between input pins does not damage them)
Trigger filter
(analog/logic)
9 settings from 0.1 to 10.0 divisions or OFF (memory recorder) ON/
OFF (recorder)
Max. rated voltage
to earth
±0.5% f.s., DC to 50 kHz ±3 dB
1 MΩ, 7 pF approx. (at 100 kHz)
DC, GND
450 V AC, DC (upper voltage which when applied to input channel casing or
between input channels does not damage them)
7
■ Appearance and Dimensions (8807-01 and 8808-01 Instrument-only)
■ Appearance and Dimensions (8807-01 and 8808-01 with printer attached)
Logic probe terminal/for 9320-01 and 9321-01
RS-232C terminal/Mini DIN 9-pin
112 mm (4.4 inch) wide thermal printer
(Detachable/option)
PC card slot/Type II
170 mm
(6.69 inch)
170 mm
(6.69 inch)
Waveform monitor (5.7 inch color STN LCD)
Analog input (Isolated BNC terminal)
8807-01: 2 ch, 8808-01: 4 ch
203 mm
(7.99 inch)
Mass:(with 8992 printer attached)
8807-01: Approx. 1.5 kg/59.91 oz
8808-01: Approx. 1.6 kg/56.44 oz
Screen contrast adjuster
52 mm
(2.05 inch)
External trigger input / output
52 mm
(2.05 inch)
280 mm
(11.02 inch)
Mass:
8807-01: Approx. 1.1 kg/38.80 oz
8808-01: Approx. 1.2 kg/42.33 oz
■ Supplied accessory PC Software Specifications
Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory)
Battery compartment at the rear
Functions
• Quick display of waveform files
• Text conversion: Conversion of binary data files to text format, with
storage in either CSV or space/tab delimited format. Span specification
and data culling available.
• Display format settings: scroll function, enlarge/reduce display, display
CH settings.
• Other: Voltage trace function, jump to cursor/trigger position function, etc.
Compatible
operating systems
Windows 2000/XP/Vista (32-bit), or Windows 7 (32-bit/64-bit)
LR6/AA alkaline batteries × 6 or 9447 BATTERY PACK × 1
■ Specifications of Options (sold separately)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm
(0.98 ft), approx. 150 g (5.3 oz)
Note: The unit-side plug of the 9320-01 is different from the 9320.
LOGIC PROBE 9320-01
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
Function
Detection of voltage signal or relay contact signal for High/Low state recording
Input
4 channels (common ground between unit and channels), digital/contact input,
switchable (contact input can detect open-collector signals), input impedance:
1MΩ (with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to
+50V), pull-up resistance: 2kΩ (contact input: internally pulled up to +5V)
Digital input threshold
Contact input
detection resistance
Response speed
1.4V/2.5V/4.0V
1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open)
and 1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short)
9320-01: 500ns or lower
Max. allowable input
0 to +50V DC (the maximum voltage that can be applied across input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft),
approx. 320 g (11.3 oz) Note: The unit-side plug of the 9321-01 is different from the 9321.
LOGIC PROBE 9321-01
Function
Input
Output (H)
detection
Output (L)
detection
Response time
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
Detection of AC or DC relay drive signal for High/Low state recording
Can also be used for power line interruption detection
4 channels (isolated between unit and channels), HIGH/LOW range switching
Input impedance: 100kΩ or higher (HIGH range), 30kΩ or higher (LOW range)
170 to 250V AC, ±DC (70 to 250V ) (HIGH range)
60 to 150V AC, ±DC (20 to 150V) (LOW range)
0 to 30V AC, ±DC (0 to 43V) (HIGH range)
0 to 10V AC, ±DC (0 to 15V) (LOW range)
Rising edge 1ms max., falling edge 3ms max. (with HIGH range at 200V
DC, LOW range at 100V DC)
Maximum allowable 250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage that can
be applied across input pins without damage)
input voltage
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm
(1.51 ft), approx. 350 g (12.3 oz)
DIFFERENTIAL PROBE 9322
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of
warm-up time; accuracy guaranteed for 1 year)
WAVE PROCESSOR 9335
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
For waveform monitor output, frequency characteristics: DC to 10MHz
(±3dB), amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3%
of full scale (at max. 2000V DC) (full scale: 2000V DC)
For detection of power line surge noise, frequency characteristics: 1kHz to 10MHz ±3dB
Distribution media
One CD-R
Operating
environment
Computer equipped with Pentium (133 MHz) or better CPU and at least 32
MB of memory,
Running under Windows 2000/XP/Vista (32-bit), or Windows 7 (32-bit/64-
DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz
to 100k Hz, response speed: 200ms or less (400V AC), accuracy: ±1% of full
scale (DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000V AC)
Display functions
RMS mode
Waveform display/X-Y display/digital value display/cursor function/
scroll function/maximum number of channels (32 channels analog, 32
channels logic)/gauge display (time, voltage axes)/graphical display
File loading
Input
Input type: balanced differential input, input impedance/capacitance:
H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth:
when using grabber clip 1500V AC/DC (CAT II ), 600V AC/DC (CAT III),
when using alligator clip: 1000V AC/DC (CAT II), 600V AC/DC (CAT III)
Readable data formats (.MEM, .REC, .RMS, .POW)
Maximum loadable file size: Maximum file size that can be saved by
a given device (file size may be limited depending on the computer
configuration)
Data conversion
Conversion to CSV format, tab delimited, space delimited/data culling
(simple)/convert for specified channel/batch conversion of multiple files
Print functions
Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/
hard copy functions usable on any printer supported by operating system
Other
Parameter calculation/search/clipboard copy/launching of other
applications
Function
DC mode
AC mode
Maximum allowable input voltage 2000V DC, 1000V AC (CAT II), 600V AC/DC (CAT III)
Output
Voltage divider for 1/1000 of input, BNC connectors (output switchable for 3 modes DC, AC, RMS)
Power source
Power terminal of the input units, or use with AC ADAPTER 9418-15
(DC 12V)
bit) (recommended system: Pentium (200 MHz) or better with at least 64 MB of memory)
Configuration of options
Input cable for measurement use is not provided.
Please purchase the optional cable.
ALLIGATOR CLIP 9790-01
Red/black set attaches to the ends
of test leads (9790)
Voltage measurement
Recommended
Logic signal measurement
GRABBER CLIP 9790-02
CONVERSION CABLE 9323
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultraflexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.5
µsec, miniature terminal type)
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
Tip Expanders
9790-03
Tip Expanders
9790-01
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
CONNECTION CORD 9198 CONNECTION CORD 9197
* Input cable for measurement use is not provided. Please
purchase the optional cable.
CLAMP ON PROBE
9132-50
UNIVERSAL CLAMP
ON CT 9277
Enables observation of AC current
waveforms. Input: 1 to 100kHz,
selectable 20 and 200A rms ranges, 2V
AC output
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
For leakage current measurement,
includes 10 mA to 200 A ranges,
with analog output of 1 V f.s. DC,
and waveform monitor output of 1
V f.s. AC at 40 Hz to 2 kHz. Requires
the AC adapter 9445-02/-03
for use with power supply
UNIVERSAL CLAMP
ON CT 9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A
/ output 2V AC
UNIVERSAL CLAMP
Not CE marked
ON CT 9279
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
AC ADAPTER 9445 -02/-03
With the 3283, continuous use.
For USA, Canada: 9445-02, For
EU: 9445-03.
For powering Differential probe
9322, 100 to 240 V AC.
For up to 2 kV DC or 1 kV AC. Use
with the AC Adapter 9418-15, for
power supply.
CLAMP ON SENSOR
9272-10
CLAMP ON LEAK HiTESTER
3283
AC ADAPTER 9418-15
DIFFERENTIAL PROBE 9322
Current measurement *High precision type
CLAMP ON
PROBE 9018 -50
Enables observation of
AC current waveforms.
Input: 40 Hz to 1 kHz,
selectable 20 to 1000 A
ranges, Output: 0.2 V AC/ range
For high voltage (up to 500 V), 1.8 m
(5.91 ft) length
High-Voltage measurement
Current measurement *50/60 Hz line use
Enables observation of
AC current waveforms.
Input: 40 Hz to 3 kHz,
selectable 10 to 500 A ranges,
Output: 0.2 V AC/ range
MEMORY HiCORDER 8808 -01 (4 ch)
For low voltage (up to 300 V), 1.7 m
(5.58 ft) length
4 isolated channels, ON/OFF
detection of AC/DC voltage
(miniature terminal type)
Recommended
Tip Expanders
9790-02
Used for connecting the 9320/9321 and
8808 series MEMORY HiCORDERs,
because the terminal shapes are different.
* This cable is not required for the smallterminal types 9327, 9320-01, and
9321-01.
LOGIC PROBE 9321-01
OUTPUT CORD 9094
Not CE marked
MEMORY HiCORDER 8807-01 (2 ch)
PT 9303
Insulation transformer, 400V or 200V AC input,
10V AC output, for AC power line measurement.
Required along with the Conversion Adapter 9199.
SENSOR UNIT 9555 -10
Required along with the
9199 adapter to connect
the 3283 to the 8808
series.
* Input cable for measurement use is not provided. Please
purchase the optional cable.
Power supply unit for the 9272
to the 9279 clamp sensors, for
signal output 9217 is necessary.
Current measurement *For Oscilloscope, wide-band frequency type
PC Software
3274
3275
3273-50
3276
CLAMP ON PROBE 3273-50
WAVE PROCESSOR 9335
DC to 50MHz wideband response,
mA-class current up to 30A rms
Convert data, print and display waveforms.
Windows 2000/XP/Vista (32-bit), Windows 7
(32-bit/64-bit)
3272
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
Carrying case
DC to 2MHz wideband response,
mA-class current up to 500A rms
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
CARRYING CASE 9648
Hard case type, for storing options
3269
POWER SUPPLY 3272
Connect and power up to one CLAMP
ON PROBE to use in combination with
the 8808 series.
POWER SUPPLY 3269
Connect and power up to four CLAMP
ON PROBEs to use in combination
with the 8808 series.
Power Supply *Sold separately
CARRYING CASE 9391
Soft case type, for storing options.
Holds more options than the 9648 hard
case.
BATTERY PACK 9447
7.2 V, 2400 mAh
Printer options
CHARGE STAND 9643
AC ADAPTER 9418-15
Independent of the 8808 series main
unit, use with the AC ADAPTER
9418-15 to charge one Model 9447.
Universal 100 to 240 V AC,
12 V DC/ 2.5 A output
The units can be operated using the supplied LR6/
AA alkaline batteries but use of the optional AC
ADAPTER 9418-15 or BATTERY PACK 9447 (the
AC ADAPTER 9418-15 is necessary for recharging)
is recommended. Manganese batteries cannot be
used. Use of commercially available rechargeable
batteries instead of the original battery pack may
result in damage to the unit.
Other options
Removable storage (CF card)
Supplied with PC
Card adapter
Not CE marked
RECORDING PAPER
9234
112 mm (4.41 in) × 18 m
(59.06 ft), 10 rolls set
CONNECTION CORD 9217 CONNECTION CORD 9165
PRINTER UNIT 8992
Printing width 100 mm (3.94 in),
used together with the 8807-01,
8808-01 main body
Cord has insulated BNC connectors
at both ends, and connects to
insulated BNC connectors on input
terminal. 1.7 m (5.58 ft) length.
Cord has metallic BNC connectors at
both ends, and connects to metallic
BNC connectors. 1.5 m (4.92 ft)
length.
RS-232C CABLE 9612
Mini DIN 9-pin - Dsub 9-pin, Cable
length 1.5 m (4.92 ft) length.
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
Not CE marked
Paper width: 70 to 220 mm (2.76 to 8.66 in),
using special-purpose AC adapter
................ Cannot be used
PC Card Precaution
Not CE marked
PAPER WINDER 220H
PC CARD 2G 9830
SPLITTER CT101A
CONVERSION ADAPTER 9199 LINE
For 100 V/ 15 A, convenient for
Banana-to-BNC, use to connect to BNC
measuring 100 V AC line current with
terminal on Input Module
clamp-on probe
PC CARD 1G 9729
............... (1 GB capacity)
PC CARD 512M 9728
.......... (512 MB capacity)
PC CARD 256M 9727
.......... (256 MB capacity)
Combination example (1)
Main unit with memory 256 kW
Printer
AC adapter
Battery pack
Input cable
Combination example (2)
Main unit with memory 256 kW
Printer
AC adapter
Battery pack
Input cable
4 ch + logic 8 ch
Printer less
8808-01 × 1
Not use
9418-15 × 1
9447 × 1
9198 × 4
4 ch + logic 8 ch
With Printer unit
8808-01 × 1
8992 × 1
9418-15 × 1
9447 × 1
9198 × 4
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road,
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
http://www.hioki.cn / E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
http://www.hioki.co.jp / E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
DISTRIBUTED BY
Beijing Office :
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
HIOKI INDIA PRIVATE LIMITED :
Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India
TEL +91-731-4223901, 4223902 FAX +91-731-4223903
http://www.hioki.in / E-mail: [email protected]
All information correct as of Jun. 29, 2010. All specifications are subject to change without notice.
8807-01E18-06E-00P
Printed in Korea