EC centrifugal fan G1G170-AB53-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 · D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 [email protected] www.ebmpapst.com Nominal data Type G1G170-AB53-01 Motor M1G074-CF Phase 1~ Nominal voltage VAC 230 Frequency Hz 50/60 Type of data definition rfa Speed min-1 5830 Power input W 360 Current draw A 1.6 Min. ambient temperature °C -25 Max. ambient temperature °C 55 Min. temp. of flow medium °C -25 Max. temp. of flow medium °C 80 ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit Subject to alterations Item no.: 51047-5-9980 · Revision: 75315 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 1 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com EC centrifugal fan G1G170-AB53-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Technical features Mass 4.7 kg Size 170 mm Surface of rotor Coated in black Material of protective cover Polyflam RPP 374-ND CS1 (UL 97-V0) Material of impeller Aluminium sheet Housing material Die-cast aluminium Direction of rotation Clockwise, seen on rotor Type of protection IP 20 Insulation class "B" Max. permissible ambient motor temp. (transp./ storage) +80 °C Min. permissible ambient motor temp. (transp./storage) -40 °C Mounting position Any Cooling bore / aperture Rotor-side Operation mode S1 Motor bearing Ball bearing Technical features - PFC, active - PWM control input - Motor current limit - Tach output - Over-temperature protected motor EMC interference immunity Acc. to EN 61000-6-2 (industrial environment) EMC interference emission Acc. to EN 61000-6-4 (industrial environment) EMC harmonics Acc. to EN 61000-3-2/3 Leakage current <= 3.5 mA Electrical leads With plug Motor protection Thermal overload protector (TOP) wired internally Approval CSA C22.2 Nr.113; UL 507 Item no.: 51047-5-9980 · Revision: 75315 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 2 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com G1G170-AB53-01 EC centrifugal fan backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Product drawing 1 Housing side parts sealed with NBR round cord (pentane-resistant) 2 3-pole strip; mating connector (not included in delivery): tyco No. 350 766-1; female connector: No. 926 884-1 2.1 L 2.2 N 2.3 PE 3 5-pole strip; mating connector (not included in delivery) Molex No. 39-01-4050, female connector Molex No. 39-00-0059 3.1 (+) 3.2 Speed monitoring 3.3 Not assigned 3.4 PWM input 3.5 (-) 4 Bleeder connection for pressure relief possible Z View Z Item no.: 51047-5-9980 · Revision: 75315 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 3 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com EC centrifugal fan G1G170-AB53-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Connection screen No. Pin Signal Function / assignment ST1 1, 2, 3 L, N, PE Power supply 230 VAC, 50-60 Hz, neutral conductor, protective earth ST2 1 UB External voltage 24-45 VDC ST2 2 DUE Speed monitoring output connection, monitoring circuit output, 3 pulses per revolution, current source 1 mA ST2 3 N.C Not assigned ST2 4 PWM PWM - 2 - 6 kHz control input, PWM on n = 100%, PWM low n = 0% ST2 5 GND GND - Connection for control interface Item no.: 51047-5-9980 · Revision: 75315 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 4 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com EC centrifugal fan G1G170-AB53-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Charts: Air flow 50 Hz Druck psf [Pa]für Rho=1,2kg/m^3 3.300 0 50 100 qv[cfm] 200 150 250 300 350 400 13 3.200 3.100 12,5 3.000 12 2.900 11,5 2.800 11 2.700 2.600 10,5 4 2.500 10 2.400 9,5 2.300 9 2.200 8,5 3 2.000 8 1.900 7,5 sf [Pa] p 1.800 8 7 1.700 1.600 6,5 7 1.500 6 1.400 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 5,5 1.300 5 1.200 12 1.100 4,5 2 11 1.000 900 4 6 3,5 800 3 700 16 600 15 2,5 10 2 500 400 1,5 14 300 1 100 150 200 250 300 350 400 qv[m^3/h] ] [Pa spf 50 9 5 ] 0 ] a [P spf spf [P a 13 100 450 500 550 600 ] [Pa spf 200 0 p sf _E[IN H2O] 2.100 Measurement: LU-57509 1 650 0,5 0 700 Measured values U f n Pe I qv psf V Hz min-1 W A m3/h Pa 1 230 50 5830 360 1.60 645 0 2 230 50 5905 346 1.52 505 1000 3 230 50 6175 308 1.35 310 2000 4 230 50 6480 268 1.18 190 2500 5 230 50 5400 287 1.26 595 0 6 230 50 5400 265 1.16 460 838 7 230 50 5400 206 0.91 270 1527 8 230 50 5400 156 0.68 160 1747 9 230 50 4300 145 0.63 475 0 10 230 50 4300 134 0.59 365 531 11 230 50 4300 104 0.46 215 968 12 230 50 4300 79 0.34 125 1108 13 230 50 3200 60 0.26 355 0 14 230 50 3200 55 0.24 270 294 15 230 50 3200 43 0.19 160 536 16 230 50 3200 32 0.14 95 614 Item no.: 51047-5-9980 · Revision: 75315 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 5 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com