GLASSvent UT Windows

™
GLASSvent
Product
1620/1620
Headline
SSG
UT Windows
Curtain Wall System
®
Best-in-Class
Description
See
Less So You
Thermal
Can See
Performance
More
in a Visually Concealed Vent
caption
Never before has something so seamless offered so much
thermal performance. GLASSvent™ UT (Ultra Thermal) Windows
are visually frameless concealed vents designed to provide a
ventilation option for curtain wall with high thermal performance.
The extraordinary thermal performance of GLASSvent™ UT
Windows exceeds the thermal standards of many high-performing
framing systems. Engineered for seamless integration with the
1600UT System™1 Curtain Wall, GLASSvent™ UT Windows can
also be inserted into other Kawneer captured curtain walls and
front set framing systems.
In addition to meeting code requirements, GLASSvent™ UT
Windows are the ideal solution for architects and designers who
want to provide fresh-air ventilation without sacrificing thermal
performance in curtain wall or storefront applications. As with all
Kawneer windows, this ultra thermal vent is made from material that
will never rot, warp or buckle due to moisture and weather exposure.
Performance
Performance Test Standards
This high-performance vent is available for integration with
curtain wall and framing systems to create a complete, advanced,
thermally superior solution for commercial construction. GLASSvent™
UT Windows are engineered to meet or exceed the minimum
requirements for the architectural window performance class,
including life-cycle testing – the highest level attainable.
GLASSvent™ UT Windows have been rigorously tested to both
AAMA and CSA standards for air, water, structural, thermal and
condensation performance. Both 1" (25.4 mm) and 1-3/4" (44.5
mm) insulating glass options are available for superior sound and
enhanced thermal benefits.
Thermal simulations show temperature variations from exterior/cold side
to interior/warm side of GLASSvent™ UT Windows.
Air Infiltration Water Structural – Uniform Wind Load Thermal Cycling Thermal Transmittance – U-Factor Condensation Resistance (CRF, I, CR) Overall Solar Heat Gain Coefficient (SHGC, VT) Sound Transmission (STC, OITC) ASTM E283
ASTM E331, E547
ASTM E330
AAMA 501.5
AAMA 1503, 507; NFRC 100
AAMA 1503; CSA A440.2; NFRC 500
AAMA 507; NFRC 200
ASTM E90, E1425; AAMA 1801
Fabrication and Installation
GLASSvent™ UT Windows are available with the option to buy
the window factory glazed by Kawneer or open for glazing by the
window installer.
The flexibility of GLASSvent™ UT Windows gives architects an ultra
thermal option that combines high-performance vents with highperformance curtain walls and storefront systems, including the
1600UT System™ 1 Curtain Wall.
Aesthetics and Design Options
Double pane
clear glass
Double pane
low-e argon glass
Triple pane
low-e argon glass
The innovative, patent-pending design of GLASSvent™ UT Windows
provides a sleek ventilation alternative for Kawneer curtain walls and
storefront framing systems. Vents are available as project-out or
outswing casement windows without the exterior aluminum profile
sightlines experienced with typical operating vents. More than a
streamlined appearance, GLASSvent™ UT Windows also deliver
a convenient means for architects to ventilate with fresh air, which
has been shown to improve indoor air quality, as well as improve
occupant comfort, well-being and productivity.
Attractive stainless steel four-bar hinges provide positive control for
trouble-free operation. Durable cast white bronze locking hardware
delivers strength and security, and integral frame-mounted insect
screens ensure building occupant comfort.
Exterior view of GLASSvent™ UT Window in curtain wall
Closed position
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
Open position
kawneer.com
770 . 449 . 5555
© Kawneer Company, Inc. 2014 LITHO IN U.S.A. Form No. 14-2196
GLASSvent™ and 1600 UT System™ 1 are trademarks of Kawneer Company, Inc. and Alcoa Inc.
Interior view of GLASSvent™ UT Window in curtain wall
Closed position
Open position
JANUARY, 2016
GLASSventTM UT Windows
EC 97911-087
INDEX
PROJECT-OUT WINDOW (1" INFILL).............................................. 3-6
PROJECT-OUT WINDOW (1-3/4" INFILL)...................................... 7-10
OUTSWING CASEMENT WINDOW (1" INFILL).......................... 11-14
OUTSWING CASEMENT WINDOW (1-3/4" INFILL).................... 15-18
THERMAL CHARTS...................................................................... 19-31
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADME077
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
GLASSventTM UT Windows
BLANK PAGE
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
JANUARY, 2016
EC 97911-087
GLASSventTM UT Windows
JANUARY, 2016
PROJECT-OUT WINDOW (1" INFILL)
Features
• Architectural Grade Window (AW)
• Tested to US and Canadian Standards
• 45° Mitered Vent and Frame Corners
• Staked Corner Joinery
• Architectural Anodized Finishes and Applied Coatings
• Large Missile and Small Missile Hurricane Impact Tested
• Blast Mitigation Tested
Exterior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Interior
Project-out Window
(1" infill)
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME077
3
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
Architectural Grade AW-PG90-AP
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
SYSTEM DEPTH
4-3/8" Overall System Depth
TYPICAL WALL THICKNESS
.125 Nominal Frame / .156" Nominal Vent
TYPICAL MAX. VENT SIZE
60" x 36"
TYPICAL MIN. VENT SIZE
17" x 17"
INFILL OPTIONS
1"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Cast White Bronze Cam Handles
OPTIONAL HARDWARE
Access Control Locks
Pole and Pole Ring
Limit Stop
OTHER OPTIONS
Insect Screens
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
CLASS and GRADE
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
PROJECT-OUT WINDOW (1" INFILL)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
4
© Kawneer Company, Inc., 2014
1-13/16"
(46)
1/8" (3.2)
kawneer.com
2-1/4"
(57.2)
D.L.O.
ADME077
1-13/16"
(46)
2-1/4"
(57.2)
2
SILL
D.L.O.
D.L.O.
1-13/16"
(46)
2-1/4"
(57.2)
W.D.
C.W. D.L.O.
1/8" (3.2)
1
HEAD
W.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
1/8" (3.2)
C.W. D.L.O.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
JANUARY, 2016
GLASSventTM UT Windows
PROJECT-OUT WINDOW (1" INFILL)
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1
3
2
TYPICAL ELEVATION
4-3/8"
(111.1)
W.D.
C.W. D.L.O.
3
JAMB
NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE.
5
GLASSventTM UT Windows
PROJECT-OUT WINDOW (1" INFILL)
JANUARY, 2016
A standard hinge for ventilators providing
approximately 45° to 60° openings depending on
size. An optional limit stop is available to restrict
hinge travel and limit vent opening.
CAM HANDLE
Cast white bronze cam handles are standard for
the manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring
provide manual operation of ventilators located
above reach. These handles are operated with a
sash pole.
POLE RING
Cast white bronze pole ring is used in conjunction
with locking hardware for sash pole operation of
ventilators.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access
control locks are offered for managed control
of vent operations. Lock is operated with a
manganese bronze removable handle.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
STAINLESS STEEL
4 BAR HINGES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6
GLASSventTM UT Windows
JANUARY, 2016
PROJECT-OUT WINDOW (1-3/4" INFILL)
Features
• Architectural Grade Window (AW)
• Tested to US and Canadian Standards
• 45° Mitered Vent and Frame Corners
• Staked Corner Joinery
• Architectural Anodized Finishes and Applied Coatings
• Large Missile and Small Missile Hurricane Impact Tested
• Blast Mitigation Tested
Exterior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Interior
Project-out Window
(1-3/4" infill)
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME077
7
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
Architectural Grade AW-PG90-AP
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
SYSTEM DEPTH
5-1/8" Overall System Depth
TYPICAL WALL THICKNESS
.125 Nominal Frame / .156" Nominal Vent
TYPICAL MAX. VENT SIZE
60" x 36"
TYPICAL MIN. VENT SIZE
17" x 17"
INFILL OPTIONS
1-3/4"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Cast White Bronze Cam Handles
OPTIONAL HARDWARE
Access Control Locks
Pole and Pole Ring
Limit Stop
OTHER OPTIONS
Insect Screens
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
CLASS and GRADE
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
PROJECT-OUT WINDOW (1-3/4" INFILL)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
8
© Kawneer Company, Inc., 2014
1-13/16"
(46)
1/8" (3.2)
kawneer.com
2-1/4"
(57.2)
D.L.O.
ADME077
1-13/16"
(46)
2-1/4"
(57.2)
2
SILL
D.L.O.
D.L.O.
1-13/16"
(46)
2-1/4"
(57.2)
W.D.
C.W. D.L.O.
1/8" (3.2)
1
HEAD
W.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
1/8" (3.2)
C.W. D.L.O.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
JANUARY, 2016
GLASSventTM UT Windows
PROJECT-OUT WINDOW (1-3/4" INFILL)
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1
3
2
TYPICAL ELEVATION
5-1/8"
(130.2)
W.D.
C.W. D.L.O.
3
JAMB
NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE.
9
GLASSventTM UT Windows
PROJECT-OUT WINDOW (1-3/4" INFILL)
JANUARY, 2016
A standard hinge for ventilators providing
approximately 45° to 60° openings depending on
size. An optional limit stop is available to restrict
hinge travel and limit vent opening.
CAM HANDLE
Cast white bronze cam handles are standard for
the manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring
provide manual operation of ventilators located
above reach. These handles are operated with a
sash pole.
POLE RING
Cast white bronze pole ring is used in conjunction
with locking hardware for sash pole operation of
ventilators.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access
control locks are offered for managed control
of vent operations. Lock is operated with a
manganese bronze removable handle.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
STAINLESS STEEL
4 BAR HINGES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10
GLASSventTM UT Windows
JANUARY, 2016
OUTSWING CASEMENT WINDOW (1" INFILL)
Features
• Architectural Grade Window (AW)
• Tested to US and Canadian Standards
• 45° Mitered Vent and Frame Corners
• Staked Corner Joinery
• Architectural Anodized Finishes and Applied Coatings
• Large Missile and Small Missile Hurricane Impact Tested
• Blast Mitigation Tested
Outswing Casement Window
(1" infill)
HINGED
LEFT
Interior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Exterior
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME077
11
OUTSWING CASEMENT WINDOW (1" INFILL)
Architectural Grade AW-PG90-C
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
SYSTEM DEPTH
4-3/8" Overall System Depth
TYPICAL WALL THICKNESS
.125 Nominal Frame / .156" Nominal Vent
TYPICAL MAX. VENT SIZE
36" x 60"
TYPICAL MIN. VENT SIZE
17" x 24"
INFILL OPTIONS
1"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Cast White Bronze Cam Handles
OPTIONAL HARDWARE
Access Control Locks
Pole and Pole Ring
Limit Stop
OTHER OPTIONS
Insect Screens
EC 97911-087
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
CLASS and GRADE
JANUARY, 2016
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
GLASSventTM UT Windows
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
12
© Kawneer Company, Inc., 2014
2-1/4"
(57.2)
1/8" (3.2)
kawneer.com
1-13/16"
(46)
D.L.O.
ADME077
1-13/16"
(46)
2-1/4"
(57.2)
2
SILL
D.L.O.
D.L.O.
1-13/16"
(46)
2-1/4"
(57.2)
1/8" (3.2)
1
HEAD
W.D.
TYPICAL ELEVATION
W.D.
C.W. D.L.O.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
1/8" (3.2)
C.W. D.L.O.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
JANUARY, 2016
GLASSventTM UT Windows
OUTSWING CASEMENT WINDOW (1" INFILL)
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1
3
2
4-3/8"
(111.1)
W.D.
C.W. D.L.O.
3
JAMB
NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE.
13
JANUARY, 2016
EC 97911-087
STAINLESS STEEL
4 BAR HINGES
A standard hinge for ventilators providing an
opening of up to 45°. An optional limit stop is
available to restrict hinge travel and limit vent
opening.
CAM HANDLE
Cast white bronze cam handles are standard for
the manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring
provide manual operation of ventilators located
above reach. These handles are operated with a
sash pole.
POLE RING
Cast white bronze pole ring is used in conjunction
with locking hardware for sash pole operation of
ventilators.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access
control locks are offered for managed control
of vent operations. Lock is operated with a
manganese bronze removable handle.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
OUTSWING CASEMENT WINDOW (1" INFILL)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
GLASSventTM UT Windows
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
GLASSventTM UT Windows
JANUARY, 2016
OUTSWING CASEMENT WINDOW (1-3/4" INFILL)
Features
• Architectural Grade Window (AW)
• Tested to US and Canadian Standards
• 45° Mitered Vent and Frame Corners
• Staked Corner Joinery
• Architectural Anodized Finishes and Applied Coatings
• Large Missile and Small Missile Hurricane Impact Tested
• Blast Mitigation Tested
Outswing Casement Window
(1-3/4" infill)
HINGED
LEFT
Interior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
Exterior
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME077
15
OUTSWING CASEMENT WINDOW (1-3/4" INFILL)
Architectural Grade AW-PG90-C
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
SYSTEM DEPTH
5-1/8" Overall System Depth
TYPICAL WALL THICKNESS
.125 Nominal Frame / .156" Nominal Vent
TYPICAL MAX. VENT SIZE
36" x 60"
TYPICAL MIN. VENT SIZE
17" x 24"
INFILL OPTIONS
1-3/4"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Cast White Bronze Cam Handles
OPTIONAL HARDWARE
Access Control Locks
Pole and Pole Ring
Limit Stop
OTHER OPTIONS
Insect Screens
EC 97911-087
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
CLASS and GRADE
JANUARY, 2016
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
GLASSventTM UT Windows
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
16
© Kawneer Company, Inc., 2014
2-1/4"
(57.2)
1/8" (3.2)
kawneer.com
1-13/16"
(46)
D.L.O.
ADME077
1-13/16"
(46)
2-1/4"
(57.2)
2
SILL
D.L.O.
D.L.O.
1-13/16"
(46)
2-1/4"
(57.2)
1/8" (3.2)
1
HEAD
W.D.
C.W. D.L.O.
TYPICAL ELEVATION
W.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-087
1/8" (3.2)
C.W. D.L.O.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
JANUARY, 2016
GLASSventTM UT Windows
OUTSWING CASEMENT WINDOW (1-3/4" INFILL)
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1
3
2
5-1/8"
(130.2)
W.D.
C.W. D.L.O.
3
JAMB
NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE.
17
JANUARY, 2016
EC 97911-087
STAINLESS STEEL
4 BAR HINGES
A standard hinge for ventilators providing an
opening of up to 45°. An optional limit stop is
available to restrict hinge travel and limit vent
opening.
CAM HANDLE
Cast white bronze cam handles are standard for
the manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring
provide manual operation of ventilators located
above reach. These handles are operated with a
sash pole.
POLE RING
Cast white bronze pole ring is used in conjunction
with locking hardware for sash pole operation of
ventilators.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access
control locks are offered for managed control
of vent operations. Lock is operated with a
manganese bronze removable handle.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
OUTSWING CASEMENT WINDOW (1-3/4" INFILL)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
GLASSventTM UT Windows
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
55-1/2"
(1410)
5'-0"
(1524)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
3'-0"
(915)
31-1/2"
(800)
Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F
Total Daylight Opening
= 31-1/2" • 55-1/2" = 12.14ft2
Total Projected Area
= 3' 0" • 5' 0" = 15 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (12.14 ÷ 15)100 = 81%
COG
U-factor
0.48 (2.74)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
© Kawneer Company, Inc., 2014
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
T
0.40 (2.27)
E IGN
PL S
M E
A D
EX FOR
0.42 (2.39)
O
0.44 (2.50)
0.38
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
Percent of Glass Area
81%
0.10 (0.57)
Based on 81% glass and center of glass (COG) U-factor of 0.28
System U-factor is equal to 0.38 Btu/hr • ft2 • °F
kawneer.com
ADME077
Btu
hr • ft2 • °F
System U-factor
0.46 (2.61)
N
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System U-factor vs Percent of Glass Area
19
20
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL CHARTS
PROJECT-OUT WINDOW WITH 1" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
0.48 (2.74)
0.46 (2.61)
0.44 (2.50)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
0.40 (2.27)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
0.42 (2.39)
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JANUARY, 2016
kawneer.com
GLASSventTM UT Windows
Vision Area / Total Area (%)
ADME077
21
EC 97911-087
THERMAL CHARTS
PROJECT-OUT WINDOW WITH 1" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
GLASSventTM UT Windows
22
JANUARY, 2016
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-087
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.57
0.55
0.46
0.56
0.53
0.44
0.54
0.52
0.42
0.53
0.50
0.40
0.52
0.49
0.38
0.50
0.47
0.36
0.49
0.46
0.34
0.47
0.44
0.32
0.46
0.43
0.30
0.44
0.41
0.28
0.43
0.40
0.26
0.41
0.38
0.24
0.40
0.37
0.22
0.38
0.35
0.20
0.37
0.34
0.18
0.35
0.32
0.16
0.33
0.31
0.14
0.32
0.29
0.12
0.30
0.28
0.10
0.29
0.26
PROJECT-OUT WINDOW
WITH 1" GLAZING
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
SHGC Matrix 2
Glass SHGC
Visible Transmittance 2
Overall SHGC 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.59
0.58
0.70
0.55
0.65
Glass VT
Overall VT 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.56
0.56
0.55
0.70
0.52
0.52
0.51
0.51
0.65
0.48
0.48
0.60
0.47
0.47
0.60
0.45
0.45
0.55
0.44
0.43
0.55
0.41
0.41
0.50
0.40
0.40
0.50
0.37
0.37
0.45
0.36
0.36
0.45
0.33
0.33
0.40
0.33
0.32
0.40
0.30
0.30
0.35
0.29
0.28
0.35
0.26
0.26
0.30
0.25
0.25
0.30
0.22
0.22
0.25
0.21
0.21
0.25
0.19
0.19
0.20
0.18
0.17
0.20
0.15
0.15
0.15
0.14
0.14
0.15
0.11
0.11
0.10
0.10
0.10
0.10
0.07
0.07
0.05
0.06
0.06
0.05
0.04
0.04
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
Warm Edge
Spacer
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Aluminum
Spacer
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Glass U-Factor
Overall U-Factor 4
3
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL CHARTS
PROJECT-OUT WINDOW WITH 1-3/4" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
Btu
hr • ft2 • °F
System U-factor
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.22 (1.25)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADME077
23
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
GLASSventTM UT Windows
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
24
JANUARY, 2016
EC 97911-087
PROJECT-OUT WINDOW WITH 1-3/4" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Glass U-Factor
PROJECT-OUT WINDOW WITH 1-3/4" GLAZING
Overall U-Factor 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.30
0.42
0.39
0.28
0.41
0.38
0.26
0.39
0.36
0.24
0.38
0.35
0.22
0.36
0.33
0.20
0.35
0.31
0.18
0.34
0.30
0.16
0.32
0.29
0.14
0.31
0.27
0.12
0.29
0.26
0.10
0.28
0.24
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Glass SHGC
kawneer.com
25
Visible Transmittance 2
Overall SHGC 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.58
0.58
0.70
0.55
0.65
Glass VT
Overall VT 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.56
0.56
0.54
0.70
0.52
0.52
0.51
0.51
0.65
0.48
0.48
0.60
0.47
0.47
0.60
0.45
0.45
0.55
0.44
0.43
0.55
0.41
0.41
0.50
0.40
0.39
0.50
0.37
0.37
0.45
0.36
0.36
0.45
0.33
0.33
0.40
0.32
0.32
0.40
0.30
0.30
0.35
0.29
0.28
0.35
0.26
0.26
0.30
0.25
0.24
0.30
0.22
0.22
0.25
0.21
0.21
0.25
0.19
0.19
0.20
0.17
0.17
0.20
0.15
0.15
0.15
0.14
0.13
0.15
0.11
0.11
0.10
0.10
0.10
0.10
0.07
0.07
0.05
0.06
0.06
0.05
0.04
0.04
ADME077
26
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL CHARTS
OUTSWING CASEMENT WINDOW WITH 1" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
0.48 (2.74)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
Btu
hr • ft2 • °F
System U-factor
0.40 (2.27)
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JANUARY, 2016
kawneer.com
GLASSventTM UT Windows
EC 97911-087
Vision Area / Total Area (%)
ADME077
27
THERMAL CHARTS
OUTSWING CASEMENT WINDOW WITH 1" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
GLASSventTM UT Windows
28
JANUARY, 2016
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-087
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.55
0.52
0.46
0.54
0.51
0.44
0.53
0.49
0.42
0.51
0.48
0.40
0.50
0.46
0.38
0.48
0.45
0.36
0.47
0.44
0.34
0.45
0.42
0.32
0.44
0.41
0.30
0.43
0.39
0.28
0.41
0.38
0.26
0.40
0.36
0.24
0.38
0.35
0.22
0.37
0.33
0.20
0.36
0.32
0.18
0.33
0.30
0.16
0.32
0.29
0.14
0.30
0.27
0.12
0.29
0.26
0.10
0.27
0.24
OUTSWING CASEMENT WINDOW
WITH 1" GLAZING
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
SHGC Matrix 2
Glass SHGC
Visible Transmittance 2
Overall SHGC 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.58
0.58
0.70
0.55
0.65
Glass VT
Overall VT 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.56
0.56
0.54
0.70
0.52
0.52
0.51
0.51
0.65
0.48
0.48
0.60
0.47
0.47
0.60
0.45
0.45
0.55
0.43
0.43
0.55
0.41
0.41
0.50
0.40
0.39
0.50
0.37
0.37
0.45
0.36
0.36
0.45
0.33
0.33
0.40
0.32
0.32
0.40
0.30
0.30
0.35
0.29
0.29
0.35
0.26
0.26
0.30
0.25
0.25
0.30
0.22
0.22
0.25
0.21
0.21
0.25
0.19
0.19
0.20
0.17
0.17
0.20
0.15
0.15
0.15
0.14
0.13
0.15
0.11
0.11
0.10
0.10
0.10
0.10
0.07
0.07
0.05
0.06
0.06
0.05
0.04
0.04
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
Warm Edge
Spacer
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Aluminum
Spacer
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Glass U-Factor
Overall U-Factor 4
3
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL CHARTS
OUTSWING CASEMENT WINDOW WITH 1-3/4" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
Btu
hr • ft2 • °F
System U-factor
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.22 (1.25)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADME077
29
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
GLASSventTM UT Windows
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
30
JANUARY, 2016
EC 97911-087
OUTSWING CASEMENT WINDOW WITH 1-3/4" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
GLASSventTM UT Windows
JANUARY, 2016
EC 97911-087
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
OUTSWING CASEMENT WINDOW
WITH 1-3/4" GLAZING
Overall U-Factor 4
Glass U-Factor 3
Aluminum
Spacer
Warm Edge
Spacer
0.30
0.40
0.37
0.28
0.39
0.35
0.26
0.38
0.34
0.24
0.36
0.32
0.22
0.35
0.31
0.20
0.33
0.29
0.18
0.32
0.28
0.16
0.30
0.26
0.14
0.29
0.25
0.12
0.27
0.23
0.10
0.26
0.22
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Glass SHGC
kawneer.com
31
Visible Transmittance 2
Overall SHGC 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.58
0.58
0.70
0.54
0.65
Glass VT
Overall VT 4
3
Aluminum
Spacer
Warm Edge
Spacer
0.75
0.56
0.56
0.54
0.70
0.52
0.52
0.51
0.50
0.65
0.48
0.48
0.60
0.47
0.47
0.60
0.45
0.45
0.55
0.43
0.43
0.55
0.41
0.41
0.50
0.40
0.39
0.50
0.37
0.37
0.45
0.36
0.35
0.45
0.33
0.33
0.40
0.32
0.32
0.40
0.30
0.30
0.35
0.28
0.28
0.35
0.26
0.26
0.30
0.25
0.24
0.30
0.22
0.22
0.25
0.21
0.20
0.25
0.19
0.19
0.20
0.17
0.17
0.20
0.15
0.15
0.15
0.14
0.13
0.15
0.11
0.11
0.10
0.10
0.09
0.10
0.07
0.07
0.05
0.06
0.06
0.05
0.04
0.04
ADME077
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
GLASSventTM UT Windows
BLANK PAGE
ADME077
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
32
JANUARY, 2016
EC 97911-087