JANUARY, 2016 GLASSventTM UT Windows EC 97911-087 INDEX PROJECT-OUT WINDOW (1" INFILL).............................................. 3-6 PROJECT-OUT WINDOW (1-3/4" INFILL)...................................... 7-10 OUTSWING CASEMENT WINDOW (1" INFILL).......................... 11-14 OUTSWING CASEMENT WINDOW (1-3/4" INFILL).................... 15-18 THERMAL CHARTS...................................................................... 19-31 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADME077 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSventTM UT Windows BLANK PAGE ADME077 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JANUARY, 2016 EC 97911-087 GLASSventTM UT Windows JANUARY, 2016 PROJECT-OUT WINDOW (1" INFILL) Features • Architectural Grade Window (AW) • Tested to US and Canadian Standards • 45° Mitered Vent and Frame Corners • Staked Corner Joinery • Architectural Anodized Finishes and Applied Coatings • Large Missile and Small Missile Hurricane Impact Tested • Blast Mitigation Tested Exterior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Interior Project-out Window (1" infill) For specific product applications, Consult your Kawneer representative. kawneer.com ADME077 3 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 Architectural Grade AW-PG90-AP TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) SYSTEM DEPTH 4-3/8" Overall System Depth TYPICAL WALL THICKNESS .125 Nominal Frame / .156" Nominal Vent TYPICAL MAX. VENT SIZE 60" x 36" TYPICAL MIN. VENT SIZE 17" x 17" INFILL OPTIONS 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Handles OPTIONAL HARDWARE Access Control Locks Pole and Pole Ring Limit Stop OTHER OPTIONS Insect Screens Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CLASS and GRADE ADME077 kawneer.com © Kawneer Company, Inc., 2014 PROJECT-OUT WINDOW (1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4 © Kawneer Company, Inc., 2014 1-13/16" (46) 1/8" (3.2) kawneer.com 2-1/4" (57.2) D.L.O. ADME077 1-13/16" (46) 2-1/4" (57.2) 2 SILL D.L.O. D.L.O. 1-13/16" (46) 2-1/4" (57.2) W.D. C.W. D.L.O. 1/8" (3.2) 1 HEAD W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 1/8" (3.2) C.W. D.L.O. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2016 GLASSventTM UT Windows PROJECT-OUT WINDOW (1" INFILL) SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1 3 2 TYPICAL ELEVATION 4-3/8" (111.1) W.D. C.W. D.L.O. 3 JAMB NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE. 5 GLASSventTM UT Windows PROJECT-OUT WINDOW (1" INFILL) JANUARY, 2016 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME077 kawneer.com © Kawneer Company, Inc., 2014 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 GLASSventTM UT Windows JANUARY, 2016 PROJECT-OUT WINDOW (1-3/4" INFILL) Features • Architectural Grade Window (AW) • Tested to US and Canadian Standards • 45° Mitered Vent and Frame Corners • Staked Corner Joinery • Architectural Anodized Finishes and Applied Coatings • Large Missile and Small Missile Hurricane Impact Tested • Blast Mitigation Tested Exterior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Interior Project-out Window (1-3/4" infill) For specific product applications, Consult your Kawneer representative. kawneer.com ADME077 7 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 Architectural Grade AW-PG90-AP TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) SYSTEM DEPTH 5-1/8" Overall System Depth TYPICAL WALL THICKNESS .125 Nominal Frame / .156" Nominal Vent TYPICAL MAX. VENT SIZE 60" x 36" TYPICAL MIN. VENT SIZE 17" x 17" INFILL OPTIONS 1-3/4" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Handles OPTIONAL HARDWARE Access Control Locks Pole and Pole Ring Limit Stop OTHER OPTIONS Insect Screens Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CLASS and GRADE ADME077 kawneer.com © Kawneer Company, Inc., 2014 PROJECT-OUT WINDOW (1-3/4" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8 © Kawneer Company, Inc., 2014 1-13/16" (46) 1/8" (3.2) kawneer.com 2-1/4" (57.2) D.L.O. ADME077 1-13/16" (46) 2-1/4" (57.2) 2 SILL D.L.O. D.L.O. 1-13/16" (46) 2-1/4" (57.2) W.D. C.W. D.L.O. 1/8" (3.2) 1 HEAD W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 1/8" (3.2) C.W. D.L.O. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2016 GLASSventTM UT Windows PROJECT-OUT WINDOW (1-3/4" INFILL) SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1 3 2 TYPICAL ELEVATION 5-1/8" (130.2) W.D. C.W. D.L.O. 3 JAMB NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE. 9 GLASSventTM UT Windows PROJECT-OUT WINDOW (1-3/4" INFILL) JANUARY, 2016 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME077 kawneer.com © Kawneer Company, Inc., 2014 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 GLASSventTM UT Windows JANUARY, 2016 OUTSWING CASEMENT WINDOW (1" INFILL) Features • Architectural Grade Window (AW) • Tested to US and Canadian Standards • 45° Mitered Vent and Frame Corners • Staked Corner Joinery • Architectural Anodized Finishes and Applied Coatings • Large Missile and Small Missile Hurricane Impact Tested • Blast Mitigation Tested Outswing Casement Window (1" infill) HINGED LEFT Interior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Exterior For specific product applications, Consult your Kawneer representative. kawneer.com ADME077 11 OUTSWING CASEMENT WINDOW (1" INFILL) Architectural Grade AW-PG90-C TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) SYSTEM DEPTH 4-3/8" Overall System Depth TYPICAL WALL THICKNESS .125 Nominal Frame / .156" Nominal Vent TYPICAL MAX. VENT SIZE 36" x 60" TYPICAL MIN. VENT SIZE 17" x 24" INFILL OPTIONS 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Handles OPTIONAL HARDWARE Access Control Locks Pole and Pole Ring Limit Stop OTHER OPTIONS Insect Screens EC 97911-087 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CLASS and GRADE JANUARY, 2016 ADME077 kawneer.com © Kawneer Company, Inc., 2014 GLASSventTM UT Windows Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 12 © Kawneer Company, Inc., 2014 2-1/4" (57.2) 1/8" (3.2) kawneer.com 1-13/16" (46) D.L.O. ADME077 1-13/16" (46) 2-1/4" (57.2) 2 SILL D.L.O. D.L.O. 1-13/16" (46) 2-1/4" (57.2) 1/8" (3.2) 1 HEAD W.D. TYPICAL ELEVATION W.D. C.W. D.L.O. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 1/8" (3.2) C.W. D.L.O. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2016 GLASSventTM UT Windows OUTSWING CASEMENT WINDOW (1" INFILL) SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1 3 2 4-3/8" (111.1) W.D. C.W. D.L.O. 3 JAMB NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE. 13 JANUARY, 2016 EC 97911-087 STAINLESS STEEL 4 BAR HINGES A standard hinge for ventilators providing an opening of up to 45°. An optional limit stop is available to restrict hinge travel and limit vent opening. CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME077 kawneer.com © Kawneer Company, Inc., 2014 OUTSWING CASEMENT WINDOW (1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSventTM UT Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 GLASSventTM UT Windows JANUARY, 2016 OUTSWING CASEMENT WINDOW (1-3/4" INFILL) Features • Architectural Grade Window (AW) • Tested to US and Canadian Standards • 45° Mitered Vent and Frame Corners • Staked Corner Joinery • Architectural Anodized Finishes and Applied Coatings • Large Missile and Small Missile Hurricane Impact Tested • Blast Mitigation Tested Outswing Casement Window (1-3/4" infill) HINGED LEFT Interior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 Exterior For specific product applications, Consult your Kawneer representative. kawneer.com ADME077 15 OUTSWING CASEMENT WINDOW (1-3/4" INFILL) Architectural Grade AW-PG90-C TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) SYSTEM DEPTH 5-1/8" Overall System Depth TYPICAL WALL THICKNESS .125 Nominal Frame / .156" Nominal Vent TYPICAL MAX. VENT SIZE 36" x 60" TYPICAL MIN. VENT SIZE 17" x 24" INFILL OPTIONS 1-3/4" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Handles OPTIONAL HARDWARE Access Control Locks Pole and Pole Ring Limit Stop OTHER OPTIONS Insect Screens EC 97911-087 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CLASS and GRADE JANUARY, 2016 ADME077 kawneer.com © Kawneer Company, Inc., 2014 GLASSventTM UT Windows Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 16 © Kawneer Company, Inc., 2014 2-1/4" (57.2) 1/8" (3.2) kawneer.com 1-13/16" (46) D.L.O. ADME077 1-13/16" (46) 2-1/4" (57.2) 2 SILL D.L.O. D.L.O. 1-13/16" (46) 2-1/4" (57.2) 1/8" (3.2) 1 HEAD W.D. C.W. D.L.O. TYPICAL ELEVATION W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-087 1/8" (3.2) C.W. D.L.O. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2016 GLASSventTM UT Windows OUTSWING CASEMENT WINDOW (1-3/4" INFILL) SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1 3 2 5-1/8" (130.2) W.D. C.W. D.L.O. 3 JAMB NOTE:THE KAWNEER GLASSventTM UT WINDOW IS SHOWN IN THESE DETAILS WITH 1600UT SYSTEMTM1 CURTAIN WALL FOR REFERENCE. OTHER KAWNEER SYSTEMS CAN BE USED. FOR PRODUCT SPECIFIC APPLICATIONS CONSULT YOUR KAWNEER REPRESENTATIVE. 17 JANUARY, 2016 EC 97911-087 STAINLESS STEEL 4 BAR HINGES A standard hinge for ventilators providing an opening of up to 45°. An optional limit stop is available to restrict hinge travel and limit vent opening. CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME077 kawneer.com © Kawneer Company, Inc., 2014 OUTSWING CASEMENT WINDOW (1-3/4" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSventTM UT Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 55-1/2" (1410) 5'-0" (1524) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3'-0" (915) 31-1/2" (800) Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F Total Daylight Opening = 31-1/2" • 55-1/2" = 12.14ft2 Total Projected Area = 3' 0" • 5' 0" = 15 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (12.14 ÷ 15)100 = 81% COG U-factor 0.48 (2.74) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) © Kawneer Company, Inc., 2014 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) T 0.40 (2.27) E IGN PL S M E A D EX FOR 0.42 (2.39) O 0.44 (2.50) 0.38 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) Percent of Glass Area 81% 0.10 (0.57) Based on 81% glass and center of glass (COG) U-factor of 0.28 System U-factor is equal to 0.38 Btu/hr • ft2 • °F kawneer.com ADME077 Btu hr • ft2 • °F System U-factor 0.46 (2.61) N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-factor vs Percent of Glass Area 19 20 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL CHARTS PROJECT-OUT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME077 kawneer.com © Kawneer Company, Inc., 2014 0.40 (2.27) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 0.42 (2.39) System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JANUARY, 2016 kawneer.com GLASSventTM UT Windows Vision Area / Total Area (%) ADME077 21 EC 97911-087 THERMAL CHARTS PROJECT-OUT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT GLASSventTM UT Windows 22 JANUARY, 2016 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-087 Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.57 0.55 0.46 0.56 0.53 0.44 0.54 0.52 0.42 0.53 0.50 0.40 0.52 0.49 0.38 0.50 0.47 0.36 0.49 0.46 0.34 0.47 0.44 0.32 0.46 0.43 0.30 0.44 0.41 0.28 0.43 0.40 0.26 0.41 0.38 0.24 0.40 0.37 0.22 0.38 0.35 0.20 0.37 0.34 0.18 0.35 0.32 0.16 0.33 0.31 0.14 0.32 0.29 0.12 0.30 0.28 0.10 0.29 0.26 PROJECT-OUT WINDOW WITH 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). SHGC Matrix 2 Glass SHGC Visible Transmittance 2 Overall SHGC 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.59 0.58 0.70 0.55 0.65 Glass VT Overall VT 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.56 0.56 0.55 0.70 0.52 0.52 0.51 0.51 0.65 0.48 0.48 0.60 0.47 0.47 0.60 0.45 0.45 0.55 0.44 0.43 0.55 0.41 0.41 0.50 0.40 0.40 0.50 0.37 0.37 0.45 0.36 0.36 0.45 0.33 0.33 0.40 0.33 0.32 0.40 0.30 0.30 0.35 0.29 0.28 0.35 0.26 0.26 0.30 0.25 0.25 0.30 0.22 0.22 0.25 0.21 0.21 0.25 0.19 0.19 0.20 0.18 0.17 0.20 0.15 0.15 0.15 0.14 0.14 0.15 0.11 0.11 0.10 0.10 0.10 0.10 0.07 0.07 0.05 0.06 0.06 0.05 0.04 0.04 ADME077 kawneer.com © Kawneer Company, Inc., 2014 Warm Edge Spacer Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Aluminum Spacer Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Glass U-Factor Overall U-Factor 4 3 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL CHARTS PROJECT-OUT WINDOW WITH 1-3/4" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Btu hr • ft2 • °F System U-factor 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.22 (1.25) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME077 23 System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADME077 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC GLASSventTM UT Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 24 JANUARY, 2016 EC 97911-087 PROJECT-OUT WINDOW WITH 1-3/4" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Glass U-Factor PROJECT-OUT WINDOW WITH 1-3/4" GLAZING Overall U-Factor 4 3 Aluminum Spacer Warm Edge Spacer 0.30 0.42 0.39 0.28 0.41 0.38 0.26 0.39 0.36 0.24 0.38 0.35 0.22 0.36 0.33 0.20 0.35 0.31 0.18 0.34 0.30 0.16 0.32 0.29 0.14 0.31 0.27 0.12 0.29 0.26 0.10 0.28 0.24 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass SHGC kawneer.com 25 Visible Transmittance 2 Overall SHGC 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.58 0.58 0.70 0.55 0.65 Glass VT Overall VT 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.56 0.56 0.54 0.70 0.52 0.52 0.51 0.51 0.65 0.48 0.48 0.60 0.47 0.47 0.60 0.45 0.45 0.55 0.44 0.43 0.55 0.41 0.41 0.50 0.40 0.39 0.50 0.37 0.37 0.45 0.36 0.36 0.45 0.33 0.33 0.40 0.32 0.32 0.40 0.30 0.30 0.35 0.29 0.28 0.35 0.26 0.26 0.30 0.25 0.24 0.30 0.22 0.22 0.25 0.21 0.21 0.25 0.19 0.19 0.20 0.17 0.17 0.20 0.15 0.15 0.15 0.14 0.13 0.15 0.11 0.11 0.10 0.10 0.10 0.10 0.07 0.07 0.05 0.06 0.06 0.05 0.04 0.04 ADME077 26 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL CHARTS OUTSWING CASEMENT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME077 kawneer.com © Kawneer Company, Inc., 2014 Btu hr • ft2 • °F System U-factor 0.40 (2.27) System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JANUARY, 2016 kawneer.com GLASSventTM UT Windows EC 97911-087 Vision Area / Total Area (%) ADME077 27 THERMAL CHARTS OUTSWING CASEMENT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT GLASSventTM UT Windows 28 JANUARY, 2016 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-087 Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.55 0.52 0.46 0.54 0.51 0.44 0.53 0.49 0.42 0.51 0.48 0.40 0.50 0.46 0.38 0.48 0.45 0.36 0.47 0.44 0.34 0.45 0.42 0.32 0.44 0.41 0.30 0.43 0.39 0.28 0.41 0.38 0.26 0.40 0.36 0.24 0.38 0.35 0.22 0.37 0.33 0.20 0.36 0.32 0.18 0.33 0.30 0.16 0.32 0.29 0.14 0.30 0.27 0.12 0.29 0.26 0.10 0.27 0.24 OUTSWING CASEMENT WINDOW WITH 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). SHGC Matrix 2 Glass SHGC Visible Transmittance 2 Overall SHGC 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.58 0.58 0.70 0.55 0.65 Glass VT Overall VT 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.56 0.56 0.54 0.70 0.52 0.52 0.51 0.51 0.65 0.48 0.48 0.60 0.47 0.47 0.60 0.45 0.45 0.55 0.43 0.43 0.55 0.41 0.41 0.50 0.40 0.39 0.50 0.37 0.37 0.45 0.36 0.36 0.45 0.33 0.33 0.40 0.32 0.32 0.40 0.30 0.30 0.35 0.29 0.29 0.35 0.26 0.26 0.30 0.25 0.25 0.30 0.22 0.22 0.25 0.21 0.21 0.25 0.19 0.19 0.20 0.17 0.17 0.20 0.15 0.15 0.15 0.14 0.13 0.15 0.11 0.11 0.10 0.10 0.10 0.10 0.07 0.07 0.05 0.06 0.06 0.05 0.04 0.04 ADME077 kawneer.com © Kawneer Company, Inc., 2014 Warm Edge Spacer Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Aluminum Spacer Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Glass U-Factor Overall U-Factor 4 3 GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL CHARTS OUTSWING CASEMENT WINDOW WITH 1-3/4" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Btu hr • ft2 • °F System U-factor 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.22 (1.25) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME077 29 System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADME077 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC GLASSventTM UT Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 30 JANUARY, 2016 EC 97911-087 OUTSWING CASEMENT WINDOW WITH 1-3/4" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) GLASSventTM UT Windows JANUARY, 2016 EC 97911-087 THERMAL PERFORMANCE MATRIX (NFRC SIZE) OUTSWING CASEMENT WINDOW WITH 1-3/4" GLAZING Overall U-Factor 4 Glass U-Factor 3 Aluminum Spacer Warm Edge Spacer 0.30 0.40 0.37 0.28 0.39 0.35 0.26 0.38 0.34 0.24 0.36 0.32 0.22 0.35 0.31 0.20 0.33 0.29 0.18 0.32 0.28 0.16 0.30 0.26 0.14 0.29 0.25 0.12 0.27 0.23 0.10 0.26 0.22 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass SHGC kawneer.com 31 Visible Transmittance 2 Overall SHGC 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.58 0.58 0.70 0.54 0.65 Glass VT Overall VT 4 3 Aluminum Spacer Warm Edge Spacer 0.75 0.56 0.56 0.54 0.70 0.52 0.52 0.51 0.50 0.65 0.48 0.48 0.60 0.47 0.47 0.60 0.45 0.45 0.55 0.43 0.43 0.55 0.41 0.41 0.50 0.40 0.39 0.50 0.37 0.37 0.45 0.36 0.35 0.45 0.33 0.33 0.40 0.32 0.32 0.40 0.30 0.30 0.35 0.28 0.28 0.35 0.26 0.26 0.30 0.25 0.24 0.30 0.22 0.22 0.25 0.21 0.20 0.25 0.19 0.19 0.20 0.17 0.17 0.20 0.15 0.15 0.15 0.14 0.13 0.15 0.11 0.11 0.10 0.10 0.09 0.10 0.07 0.07 0.05 0.06 0.06 0.05 0.04 0.04 ADME077 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSventTM UT Windows BLANK PAGE ADME077 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 32 JANUARY, 2016 EC 97911-087