1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 FEATURES Features Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • 1600 Wall SystemTM5 is an inside glazed captured curtain wall • • • • • • • • • • • • • 1600 Wall SystemTM5 has a 2-1/2" (63.5) sight line Standard 6" (152.4) or 7-1/2" (190.5) system depths Condensation water management capability Integral perimeter caulk leg Thermally improved Snap-on covers Optional split vertical mullion Type "A" fabrication: Screw Spline or Shear Block Type "B" fabrication: Punched openings SSG Option Two color option PermanodicTM anodized finishes in seven choices Painted finishes in standard and custom choices • • • • • Steel reinforcing available Rain screen and backpans Pressure plate option for outside glazing requirements Integrates with concealed GLASSventTM for curtain wall Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single Blade Systems • Profit$MakerTM plus die sets available Product Applications © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Optional Features • Ideal for low-rise to mid-rise curtain wall applications where inside glazing and high performance is desired for ribbon windows and multi-lite punched openings in both new and remodel construction projects For specific product applications, Consult your Kawneer representative. kawneer.com ADMD050 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 BLANK PAGE ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 DECEMBER, 2013 EC 97911-053 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 3 INDEX PICTORIAL VIEW.............................................................................. 4-7 1/4 SIZE DETAILS........................................................................... 8-11 ENTRANCE DETAILS........................................................................ 12 CORNERS........................................................................................... 13 VENT OPTIONS.................................................................................. 14 MISCELLANEOUS............................................................................. 15 WIND LOAD CHARTS................................................................... 16-24 DEADLOAD CHARTS........................................................................ 25 THERMAL CHARTS...................................................................... 26-35 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD050 VERTICAL MULLION HEAD GLASS STOP THERMAL ISOLATOR GLASS STOP SILL COVER ADMD050 kawneer.com © Kawneer Company, Inc., 2013 PICTORIAL VIEW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 DECEMBER, 2013 EC 97911-053 TYPE "A" ASSEMBLY Screw Spline for Ribbon Window HORIZONTAL © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM5 EC 97911-053 PICTORIAL VIEW TYPE "B" ASSEMBLY Punched Openings HEAD GLASS STOP THERMAL ISOLATOR HORIZONTAL GLASS STOP COVER VERTICAL MULLION SILL ADMD050 5 VERTICAL MULLION SHEAR BLOCK HEAD GLASS STOP THERMAL ISOLATOR GLASS STOP FLAT FILLER SILL COVER ADMD050 kawneer.com © Kawneer Company, Inc., 2013 PICTORIAL VIEW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 DECEMBER, 2013 EC 97911-053 TYPE "A" ASSEMBLY Shear Block Assembly for Curtain Wall HORIZONTAL © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM5 EC 97911-053 PICTORIAL VIEW TYPE "A" ASSEMBLY Screw Spline with Split Mullion for Curtain Wall SPLIT MULLION HEAD GLASS STOP THERMAL ISOLATOR HORIZONTAL GLASS STOP SILL COVER ADMD050 7 1 1A 5A 4 5 4A 5A 4 6A 3 3A 4A 6"(152.4) 6"(152.4) 7-1/2"(190.5) 7-1/2"(190.5) 1 1A 2 2A ELEVATION IS NUMBER KEYED TO DETAILS 1 1A 2 2A 3 3A 5 5A ADMD050 6 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0' 2-1/2" (63.5) 6A kawneer.com © Kawneer Company, Inc., 2013 3A 6 2-1/2" (63.5) RIBBON WINDOW (TYPE "A" SCREW SPLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 6"(152.4) 3 2-1/2" (63.5) 1600 WALL SYSTEMTM5 7-1/2"(190.5) 4A 6"(152.4) 4 7-1/2"(190.5) 8 DECEMBER, 2013 EC 97911-053 NOTE: Available in 6" (Shown Dotted in) and 7-1/2" depths. Consult your Kawneer Representative for more information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4 4A kawneer.com 5 3A 4 5 4A 5A 4 5A 4A 2-1/2" (63.5) 2-1/2" (63.5) 3 6"(152.4) 7-1/2"(190.5) 6"(152.4) 7-1/2"(190.5) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 1600 WALL SYSTEMTM5 EC 97911-053 SCALE 3" = 1'-0" 1A 6"(152.4) 7-1/2"(190.5) 6A 1 1A 2 2A 3 3A ELEVATION IS NUMBER KEYED TO DETAILS 5 ADMD050 1 1A 2 2A 3 3A 5A 6 9 RIBBON WINDOW (TYPE "B") NOTE: Available in 6" (Shown Dotted in) and 7-1/2" depths. Consult your Kawneer Representative for more information. MAX. UNIT WIDTH 24’-0” 1 6 6"(152.4) 7-1/2"(190.5) 2-1/2" (63.5) 6A 6"(152.4) 6 6"(152.4) 7-1/2"(190.5) 1 7A 6A 8 2 8A 3 2 3 3 4 5 5 2-1/2" (63.5) 7 7A ADMD050 8 8A kawneer.com © Kawneer Company, Inc., 2013 2 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CURTAIN WALL (SHEAR BLOCK) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6A 7 6"(152.4) NOTE: Available in 6" (Shown Dotted in) and 7-1/2" depths. Consult your Kawneer Representative for more information. 2-1/2" (63.5) 1600 WALL SYSTEMTM5 7-1/2"(190.5) 6 7-1/2"(190.5) 10 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS 4 6 kawneer.com NOTE: Available in 6" (Shown Dotted in) and 7-1/2" depths. Consult your Kawneer Representative for more information. 7 6A 7A 2 6A 8 5 7 ADMD050 1 7A 2-1/2" (63.5) EC 97911-053 8 7-1/2"(190.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6 6"(152.4) 7-1/2"(190.5) 6"(152.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 1600 WALL SYSTEMTM5 11 CURTAIN WALL (SCREW SPLINE) SCALE 3" = 1'-0" 6"(152.4) 7-1/2"(190.5) 1 2 8A 3 2 3 3 4 ELEVATION IS NUMBER KEYED TO DETAILS 4 5 2-1/2" (63.5) 8A 1600 WALL SYSTEMTM5 12 DECEMBER, 2013 ENTRANCE DETAILS (1" INFILL) EC 97911-053 SCALE 3" = 1'-0" 3 4 1 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P C/H ELEVATION IS NUMBER KEYED TO DETAILS 3 BUTT HUNG OR OFFSET PIVOT 1A 1-15/16" TYP. DOOR JAMB TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2 1 1A 1B 1B DOOR JAMB CENTER HUNG TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVERHEAD CLOSER OR SURFACE CLOSER 2 TRANSOM BAR CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER ADMD050 kawneer.com © Kawneer Company, Inc., 2013 4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7/8" (22.2) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM5 EC 97911-053 CORNERS SCALE 3" = 1'-0" 90° OUTSIDE CORNER 90° OUTSIDE CORNER 90° INSIDE CORNER 90° INSIDE CORNER ADMD050 13 HEAD SILL JAMB ADMD050 JAMB AT SSG MULLION NOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options HEAD SILL JAMB kawneer.com © Kawneer Company, Inc., 2013 VENT OPTIONS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" GLASSventTM FOR CUTAIN WALL 8225TL IsoLockTM WINDOW SHOWN 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 15 MISCELLANEOUS SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. kawneer.com PRESSURE PLATE HORIZONTAL FOR OUTSIDE GLAZING PRESSURE PLATE VERTICAL FOR OUTSIDE GLAZING STEEL REINFORCING BACKPAN HORIZONTAL BACKPAN VERTICAL BACKPAN SSG VERTICAL ADMD050 16 1600 WALL SYSTEMTM5 DECEMBER, 2013 WIND LOAD / DEADLOAD CHARTS EC 97911-053 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.35) thick glass supported on two setting blocks placed at the loading points shown. ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 WIND LOAD CHARTS (TYPE "B" SCREW SPLINE) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN 1 METERS 1.5 .5 2 16 13 4 A 4.5 12 9 3 E 2.5 8 7 6" (154.4) 10 2 6 5 1.5 4 3.5 11 10 3 9 A 8 2.5 B 7 E D 6 C 2 5 3-3/4" (95.3) C D MULLION HEIGHT IN FEET 3.5 METERS B 11 4 13 METERS 12 1.5 4 1 3 2 2 0.5 2 3 4 5 6 7 I = 8.085 (336.52 x 104) S = 2.692 (44.11 x 103) 8 0.5 1 166036 1 1 3 1 166040 0 1 2 1 4 5 6 7 8 TWIN SPAN METERS .5 3 I = 3.115 (129.66 x 104) S = 1.633 (26.76 x 103) MULLION CENTERS IN FEET SINGLE SPAN METERS 1.5 .5 2 1 1.5 2 16 16 15 4 13 A 12 E 10 2.5 8 7 2 6 5 7-1/2" (190.5) 9 METERS 3 1.5 3.5 11 B 10 9 3 C E D 2.5 8 7 2 6 5 1.5 4 4 1 3 2 2 1 2 3 4 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 0.5 1 166013 0 1 3 0.5 1 I = 15.271 (635.63 x 104) S = 4.139 (67.83 x 103) 166018 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD050 5-1/4" (133.4) 3.5 METERS D 11 4 C MULLION HEIGHT IN FEET 12 4.5 14 B 13 15 4.5 A 14 MULLION HEIGHT IN FEET 2 14 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 1.5 15 4.5 14 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 16 15 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 17 8 I = 7.342 (305.60 x 104) S = 2.759 (45.21 x 103) 1600 WALL SYSTEMTM5 DECEMBER, 2013 WIND LOAD CHARTS (TYPE "A" SCREW SPLINE) EC 97911-053 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN 1 METERS 1.5 .5 2 16 15 2 4.5 14 4 A 12 C D E 3 2.5 8 7 6" (154.4) 9 METERS 10 2 6 5 1.5 4 3.5 11 10 3 9 A 8 C E D 7 2.5 B 2 6 5 3-3/4" (95.3) 3.5 B 11 4 13 METERS 12 MULLION HEIGHT IN FEET 13 1.5 4 1 3 2 2 0.5 1 2 3 4 5 6 7 I = 7.553 (314.38 x 10 ) S = 2.519 (41.28 x 103) 4 8 MULLION CENTERS IN FEET 0.5 1 165016 & 166033 0 1 3 1 165016 & 166039 0 1 2 1 4 5 6 7 I = 3.276 (136.36 x 104) S = 1.739 (28.50 x 103) 8 SINGLE SPAN METERS .5 3 MULLION CENTERS IN FEET SINGLE SPAN METERS 1.5 .5 2 16 1 1.5 2 16 15 7 2 6 5 7-1/2" (190.5) 2.5 8 METERS 3 9 1.5 4 3.5 11 B 10 3 C E D 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 0.5 1 166010 & 166011 0 1 3 0.5 1 I = 14.344 (597.04 x 10 ) S = 3.687 (60.42 x 103) 4 166010 & 166015 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD050 5-1/4" (133.4) MULLION HEIGHT IN FEET E 10 A 12 3.5 D 11 4 13 METERS 4 C 12 4.5 14 B 13 15 4.5 A 14 MULLION HEIGHT IN FEET 1.5 15 4.5 14 MULLION HEIGHT IN FEET 1 16 8 I = 7.571 (315.13 x 104) S = 2.868 (47.00 x 103) kawneer.com © Kawneer Company, Inc., 2013 METERS .5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 WIND LOAD CHARTS (SPLIT MULLION) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN 1 METERS 1.5 2 .5 16 2 9 28 A 8.5 27 12 A D E C 2.5 8 7 2 6 5 1.5 MULLION HEIGHT IN FEET 9 METERS 3 MULLION HEIGHT EQUAL EQUAL B 10 6" (154.4) 11 MULLION HEIGHT 3.5 4 26 7.5 24 23 7 22 E D C 21 B 6.5 20 6 19 5.5 18 1 3 2 17 15 166080 & 166081 1 2 3 4 5 6 7 5 16 0.5 1 I = 8.172 (340.14 x 104) S = 2.423 (39.71 x 103) 8 4.5 0 1 2 1 4 5 6 7 8 TWIN SPAN METERS .5 3 MULLION CENTERS IN FEET SINGLE SPAN METERS 1.5 .5 2 16 1 1.5 2 30 15 9 29 4.5 14 28 4 13 C 2.5 7 2 6 5 1.5 4 1 3 MULLION HEIGHT IN FEET E D B MULLION HEIGHT EQUAL EQUAL 8 3-3/4" (95.3) A METERS 3 MULLION HEIGHT 11 9 8 26 3.5 10 8.5 27 12 MULLION HEIGHT IN FEET 8 26 25 7.5 24 23 22 6.5 21 20 6 19 B 18 E D 17 2 166084 & 166085 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 5.5 C 5 16 0.5 1 7 A I = 4.031 (167.78 x 104) S = 2.063 (33.81 x 103) ADMD050 15 4.5 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 METERS 13 4 METERS 14 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 1.5 29 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 30 15 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 19 1600 WALL SYSTEMTM5 DECEMBER, 2013 WIND LOAD CHARTS (SPLIT MULLION) EC 97911-053 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN METERS 1.5 .5 2 1 1.5 2 30 9 29 4.5 A 28 14 4 13 8 7 2 6 5 1.5 MULLION HEIGHT IN FEET 2.5 MULLION HEIGHT EQUAL EQUAL 9 7-1/2" (190.5) 3 MULLION HEIGHT 10 C METERS D E 8 26 3.5 11 8.5 27 B 12 MULLION HEIGHT IN FEET A 26 7.5 24 B C E D 23 7 22 6.5 21 20 6 19 5.5 18 4 1 3 2 17 1 15 166082 & 166083 1 2 3 4 5 6 7 5 16 0.5 0 I = 15.977 (665.01 x 10 ) S = 3.696 (60.57 x 103) 8 4.5 0 4 MULLION CENTERS IN FEET 1 2 4 5 6 7 8 TWIN SPAN METERS 1 3 MULLION CENTERS IN FEET SINGLE SPAN .5 METERS 15 METERS 1.5 .5 2 1 1.5 2 30 16 9 29 4.5 B 3.5 7 2 6 5 1.5 4 2 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 7.5 23 7 C E D 22 6.5 21 20 6 19 5.5 5 16 166086 & 166087 1 B 24 17 0.5 1 26 18 1 3 MULLION HEIGHT IN FEET 2.5 8 MULLION HEIGHT EQUAL EQUAL 3 9 0 8 26 E D C 10 8.5 27 5-1/4" (133.4) 11 4 MULLION HEIGHT 12 A METERS 13 MULLION HEIGHT IN FEET A 28 14 METERS 15 I = 9.049 (376.65 x 104) S = 3.331 (54.59 x 103) ADMD050 15 4.5 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2013 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 16 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 DECEMBER, 2013 1600 WALL SYSTEMTM5 EC 97911-053 WIND LOAD CHARTS (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN 1 METERS 1.5 .5 2 1.5 2 9 29 4.5 28 14 4 13 2.5 8 7 2 6 5 1.5 MULLION HEIGHT IN FEET C D E METERS 9 3 6" (154.4) B MULLION HEIGHT EQUAL EQUAL 3.5 11 10 8 26 A MULLION HEIGHT 12 8.5 27 A 26 7.5 24 B 23 7 C 22 D 21 6.5 E 20 6 19 5.5 18 4 1 3 2 17 1 15 166038 2 3 4 5 6 7 5 16 0.5 1 I = 7.606 (316.59 x 104) S = 2.654 (43.49 x 103) 8 MULLION CENTERS IN FEET 4.5 0 1 2 4 5 6 7 8 TWIN SPAN METERS 1 3 MULLION CENTERS IN FEET SINGLE SPAN .5 METERS 15 0 METERS 1.5 .5 2 1 1.5 2 30 16 9 29 4.5 28 14 4 13 8 26 9 A 8 2.5 B 7 E D C 2 6 5 1.5 4 1 3 2 METERS 3 3-3/4" (95.3) 10 MULLION HEIGHT 11 MULLION HEIGHT EQUAL EQUAL 3.5 1 2 3 4 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 7.5 24 23 7 22 6.5 21 A 20 6 19 5.5 B 17 5 16 166041 0 26 18 0.5 1 MULLION HEIGHT IN FEET 12 MULLION HEIGHT IN FEET 8.5 27 I = 2.973 (123.75 x 104) S = 1.567 (25.68 x 103) ADMD050 15 E D 0 1 2 3 4 4.5 C 5 6 7 MULLION CENTERS IN FEET 8 METERS 15 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 30 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 21 1600 WALL SYSTEMTM5 DECEMBER, 2013 WIND LOAD CHARTS (SHEAR BLOCK) EC 97911-053 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN METERS .5 1 METERS 1.5 .5 2 1 1.5 2 30 16 9 A 14 4 C 8 10 9 2.5 8 7 METERS 3 2 6 5 7-1/2" (190.5) E MULLION HEIGHT EQUAL EQUAL 3.5 1.5 MULLION HEIGHT IN FEET 26 D 11 8.5 27 MULLION HEIGHT 12 A 28 B 13 MULLION HEIGHT IN FEET 29 4.5 B 26 7.5 24 C 23 7 22 D 21 6.5 20 6 E 19 5.5 18 4 1 3 2 17 1 15 166005 1 2 3 4 5 6 7 5 16 0.5 0 METERS 15 I = 14.042 (584.47 x 10 ) S = 3.813 (62.48 x 103) 4 8 MULLION CENTERS IN FEET 4.5 0 1 2 3 4 5 6 7 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 22 8 MULLION CENTERS IN FEET METERS .5 1 1.5 2 30 9 29 28 8.5 27 23 7 A 22 6.5 21 B 20 6 C 19 18 5.5 D 17 E 16 5 15 4.5 0 1 2 3 4 5 7-1/2" (190.5) 7.5 24 METERS MULLION HEIGHT IN FEET 26 MULLION HEIGHT 8 26 6 7 MULLION CENTERS IN FEET 8 166005 W/162301/302/303 Ia = 14.042 (584.47 x 104) Sa = 3.813 (62.48 x 103) Is = 9.347 (389.05 x 104) Ss = 4.099 (67.17 x 103) ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN DECEMBER, 2013 1600 WALL SYSTEMTM5 EC 97911-053 WIND LOAD CHARTS (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN 1 METERS 1.5 .5 2 2 29 4.5 28 14 4 8 26 C E D 9 3 2.5 8 7 METERS 10 2 6 5 1.5 4 MULLION HEIGHT EQUAL EQUAL B 5-1/4" (133.4) A 11 MULLION HEIGHT 3.5 2 166008 3 4 5 6 7 I = 6.639 (276.34 x 104) S = 2.507 (41.08 x 103) 8 SINGLE SPAN METERS .5 1 1.5 2 30 9 29 28 8.5 27 7.5 23 7 22 6.5 21 20 6 19 METERS 24 5-1/4" (133.4) 26 MULLION HEIGHT 8 26 A 5.5 18 B 17 5 16 15 0 1 2 3 4 4.5 C E D 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 23 7 B 22 6.5 21 20 6 19 E D C 5.5 5 16 1 2 7.5 24 17 0.5 1 A 26 18 1 3 MULLION HEIGHT IN FEET 12 MULLION HEIGHT IN FEET 8.5 27 166008 W/162301/302/303 Ia = 6.639 (276.34 x 104) Sa = 2.507 (41.08 x 103) Is = 9.347 (389.05 x 104) Ss = 4.099 (67.17 x 103) ADMD050 15 4.5 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 METERS 13 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 1.5 9 15 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 30 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 23 1600 WALL SYSTEMTM5 DECEMBER, 2013 WIND LOAD CHARTS (SHEAR BLOCK) EC 97911-053 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN TWIN SPAN METERS .5 1 METERS 1.5 .5 2 1 1.5 2 30 16 9 29 4.5 28 14 A 9 2.5 8 7 2 6 5 1.5 4 2 3 4 5 6 7 23 7 22 6.5 21 C E D 20 6 19 5.5 5 15 166017 2 7.5 16 1 1 B 24 17 0.5 0 26 18 1 3 MULLION HEIGHT IN FEET 3 C E D MULLION HEIGHT EQUAL EQUAL 10 3.5 5-1/4" (133.4) 11 8 26 B METERS MULLION HEIGHT IN FEET 12 8.5 A 27 MULLION HEIGHT 13 4 METERS 15 I = 8.292 (345.14 x 10 ) S = 3.046 (49.91 x 103) 4 8 MULLION CENTERS IN FEET 4.5 0 1 2 3 4 5 6 7 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 24 8 MULLION CENTERS IN FEET METERS .5 1 1.5 2 30 9 29 28 8.5 27 23 7 22 6.5 21 20 6 A 19 18 5.5 B 17 5 16 C E D 15 0 1 2 3 4 5 5-1/4" (133.4) 7.5 24 METERS MULLION HEIGHT IN FEET 26 MULLION HEIGHT 8 26 4.5 6 7 MULLION CENTERS IN FEET 8 166017 W/162301/302/303 Ia = 8.292 (345.14 x 104) Sa = 3.046 (49.91 x 103) Is = 9.347 (389.05 x 104) Ss = 4.099 (67.17 x 103) ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 25 DEADLOAD CHARTS 6" (152.4) 6" (152.4) 166035 METERS .5 1 METERS 1.5 .5 A = 1/4" Glass – 1/8 Point Loading B = 1/4" Glass – 1/4 Point Loading 2 13 1 2 12 10 3.5 B = 1" Glass - 1/8 Point Loading C = 1" Glass - 1/4 Point Loading 11 10 GLASS HEIGHT IN FEET 3 9 7 2 6 C B A 5 METERS 2.5 8 1.5 4 1 3 2 3 9 2.5 8 7 2 6 5 C B 4 1.5 A 1 3 2 0.5 0.5 1 1 1 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 8 SPAN IN FEET 7-1/2" (190.5) 7-1/2" (190.5) 166007 166002 METERS METERS 1 1.5 A = 1/4" Glass – 1/8 Point Loading B = 1/4" Glass – 1/4 Point Loading 2 13 12 2 6 5 METERS GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2013 2.5 7 1.5 4 1 3 2 2 3.5 11 10 9 8 1.5 12 3 A C B 1 13 B = 1" Glass - 1/8 Point Loading C = 1" Glass - 1/4 Point Loading 3.5 11 10 .5 GLASS HEIGHT IN FEET .5 3 9 2.5 8 7 A C B 6 2 5 1.5 4 1 3 2 0.5 0.5 1 1 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET 1 2 3 4 5 SPAN IN FEET ADMD050 6 7 8 METERS 0 kawneer.com METERS 3.5 11 SPAN IN FEET Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 13 12 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 166031 1600 WALL SYSTEMTM5 26 DECEMBER, 2013 THERMAL CHARTS EC 97911-053 Project Specific U-factor Example Calculation (Based on single bay of Curtain Wall/Window Wall) 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. VISION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. VISION 2-1/2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 31'-3" SPANDREL 8'-0" D.L.O. 2-1/2" Typ. 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 27 THERMAL CHARTS Vision Area Chart System U-factor vs Percent of Vision Area (N 0.70 E IGN PL S M E A D EX OR F T O COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F T O 3.00 4.00 © Kawneer Company, Inc., 2013 5.00 0.30 0.21 0.20 0.10 91% 95 0.40 ) 11.00 15.00 19.00 30.00 0.50 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD050 System U-Factor for Vision Glass ADMD050 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS (CAPTURED) Vision Area / Total Area (%) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1600 WALL SYSTEMTM5 kawneer.com © Kawneer Company, Inc., 2013 COG U-factor System U-Factor (Btu/h·ft2·°F) 28 DECEMBER, 2013 EC 97911-053 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 0.60 0.55 0.50 kawneer.com Spandrel R-Value 0.45 2.00 0.40 3.00 0.35 4.00 0.30 5.00 95 0.25 0.20 11.00 0.15 15.00 19.00 30.00 0.10 90 85 80 Spandrel Area / Total Area (%) ADMD050 75 70 0.05 System U-Factor (Btu/h·ft2·°F) DECEMBER, 2013 1600 WALL SYSTEMTM5 THERMAL CHARTS (CAPTURED) Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factors for Spandrel Glass 0.75 0.70 0.65 29 Vision Area / Total Area (%) COG VT System Visible Transmittance (VT) vs Percent of Vision Area Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD050 kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS (CAPTURED) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC COG SHGC System VT 30 DECEMBER, 2013 EC 97911-053 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Charts are generated per AAMA 507. © Kawneer Company, Inc., 2013 COG U-factor kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor (Btu/h·ft2·°F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 1600 WALL SYSTEMTM5 EC 97911-053 THERMAL CHARTS (SSG) Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass Vision Area / Total Area (%) ADMD050 31 THERMAL CHARTS (SSG) System U-Factors for Spandrel Glass 0.70 0.65 0.60 0.50 Spandrel R-Value 0.45 2.00 0.40 0.35 3.00 0.30 4.00 5.00 0.25 0.20 11.00 15.00 19.00 30.00 90 85 80 ADMD050 75 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 kawneer.com © Kawneer Company, Inc., 2013 95 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.55 System U-Factor (Btu/h·ft2·°F) 32 DECEMBER, 2013 EC 97911-053 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 0.15 0.10 70 0.05 Spandrel Area / Total Area (%) System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 COG SHGC kawneer.com 1600 WALL SYSTEMTM5 EC 97911-053 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD050 33 THERMAL CHARTS (SSG) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area COG VT 1600 WALL SYSTEMTM5 DECEMBER, 2013 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-053 Overall U-Factor 4 0.48 0.65 0.46 0.63 0.44 0.61 0.42 0.60 0.40 0.58 0.38 0.57 0.36 0.55 0.34 0.54 0.32 0.52 0.30 0.51 0.28 0.49 0.26 0.47 0.24 0.46 0.22 0.44 0.20 0.43 SHGC Matrix 2 (CAPTURED) Visible Transmittance 2 (CAPTURED) Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.80 0.90 0.78 0.85 0.76 0.85 0.74 0.80 0.72 0.80 0.69 0.75 0.67 0.75 0.65 0.70 0.63 0.70 0.61 0.65 0.59 0.65 0.56 0.60 0.54 0.60 0.52 0.55 0.50 0.55 0.48 0.50 0.46 0.50 0.43 0.45 0.41 0.45 0.39 0.40 0.37 0.40 0.35 0.35 0.33 0.35 0.30 0.30 0.28 0.30 0.26 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.17 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/h • ft 2 • °F) (CAPTURED) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 34 1600 WALL SYSTEMTM5 DECEMBER, 2013 EC 97911-053 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Glass U-Factor 3 Overall U-Factor 4 0.48 0.58 0.46 0.56 0.44 0.55 0.42 0.53 0.40 0.51 0.38 0.50 0.36 0.48 0.34 0.46 0.32 0.45 0.30 0.43 0.28 0.42 0.26 0.40 0.24 0.38 0.22 0.37 0.20 0.35 SHGC Matrix 2 (SSG) Visible Transmittance 2 (SSG) Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.84 0.90 0.79 0.85 0.79 0.85 0.74 0.80 0.75 0.80 0.70 0.75 0.71 0.75 0.66 0.70 0.66 0.70 0.61 0.65 0.62 0.65 0.57 0.60 0.57 0.60 0.52 0.55 0.53 0.55 0.48 0.50 0.49 0.50 0.44 0.45 0.44 0.45 0.39 0.40 0.40 0.40 0.35 0.35 0.36 0.35 0.31 0.30 0.31 0.30 0.26 0.25 0.27 0.25 0.22 0.20 0.22 0.20 0.17 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/h • ft 2 • °F) (SSG) NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD050 35 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM5 BLANK PAGE ADMD050 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 36 DECEMBER, 2013 EC 97911-053