R595 - Reliability Data

Reliability Data Report
Product Family R595
LTM2987
Reliability Data Report
Report Number: R595
Report generated on: Tue Sep 16 4:14:08 PDT 2014
OPERATING LIFE TEST
PACKAGE TYPE
BGA 15X15
Totals
SAMPLE SIZE
154
154
OLDEST DATE
NEWEST DATE
K DEVICE HRS
1
CODE
CODE
(+125°C)
1302
-
1302
-
154
154
No. of FAILURES
2,3
0
0
HIGHLY ACCELERATED STRESS TEST AT +130 DEG C / 85% RH
PACKAGE TYPE
BGA 15X15
Totals
SAMPLE SIZE
534
534
OLDEST DATE
NEWEST DATE
K DEVICE HRS
No. of FAILURES
4
CODE
CODE
1302
-
1335
-
(+85°C)
1320
1320
0
0
OLDEST DATE
NEWEST DATE
K DEVICE
No. of FAILURES
CODE
CODE
CYCLES
1211
-
1335
-
684
684
0
0
OLDEST DATE
NEWEST DATE
K DEVICE
No. of FAILURES
CODE
CODE
CYCLES
1211
-
1335
-
663
663
0
0
OLDEST DATE
NEWEST DATE
K DEVICE
No. of FAILURES
CODE
CODE
CYCLES
1211
-
1335
-
TEMP CYCLE FROM +55 TO +125 DEG C
PACKAGE TYPE
SAMPLE SIZE
BGA 15X15
Totals
672
672
THERMAL SHOCK FROM +55 TO +125 DEG C
PACKAGE TYPE
SAMPLE SIZE
BGA 15X15
Totals
663
663
HIGH TEMPERATURE BAKE AT 150 DEG C
PACKAGE TYPE
SAMPLE SIZE
BGA 15X15
Totals
558
558
588
588
(1) Assumes Activation Energy = 0.7 Electron Volts
(2) Failure Rate Equivalent to +55 °C, 60% Confidence Level =76.45 FITS
(3) Mean Time Between Failure in Years = 1493.10
(4) Assumes 20X Acceleration from 85 °C to +130 °C
Note 1: 1 FIT = 1 Failure in One Billion Hours.
Note 2: HAST, Temp Cycle & Thermal Shock are subjected to J-STD-020 MSL 3/4 Preconditioning
0
0