Reliability Data Report Product Family R595 LTM2987 Reliability Data Report Report Number: R595 Report generated on: Tue Sep 16 4:14:08 PDT 2014 OPERATING LIFE TEST PACKAGE TYPE BGA 15X15 Totals SAMPLE SIZE 154 154 OLDEST DATE NEWEST DATE K DEVICE HRS 1 CODE CODE (+125°C) 1302 - 1302 - 154 154 No. of FAILURES 2,3 0 0 HIGHLY ACCELERATED STRESS TEST AT +130 DEG C / 85% RH PACKAGE TYPE BGA 15X15 Totals SAMPLE SIZE 534 534 OLDEST DATE NEWEST DATE K DEVICE HRS No. of FAILURES 4 CODE CODE 1302 - 1335 - (+85°C) 1320 1320 0 0 OLDEST DATE NEWEST DATE K DEVICE No. of FAILURES CODE CODE CYCLES 1211 - 1335 - 684 684 0 0 OLDEST DATE NEWEST DATE K DEVICE No. of FAILURES CODE CODE CYCLES 1211 - 1335 - 663 663 0 0 OLDEST DATE NEWEST DATE K DEVICE No. of FAILURES CODE CODE CYCLES 1211 - 1335 - TEMP CYCLE FROM +55 TO +125 DEG C PACKAGE TYPE SAMPLE SIZE BGA 15X15 Totals 672 672 THERMAL SHOCK FROM +55 TO +125 DEG C PACKAGE TYPE SAMPLE SIZE BGA 15X15 Totals 663 663 HIGH TEMPERATURE BAKE AT 150 DEG C PACKAGE TYPE SAMPLE SIZE BGA 15X15 Totals 558 558 588 588 (1) Assumes Activation Energy = 0.7 Electron Volts (2) Failure Rate Equivalent to +55 °C, 60% Confidence Level =76.45 FITS (3) Mean Time Between Failure in Years = 1493.10 (4) Assumes 20X Acceleration from 85 °C to +130 °C Note 1: 1 FIT = 1 Failure in One Billion Hours. Note 2: HAST, Temp Cycle & Thermal Shock are subjected to J-STD-020 MSL 3/4 Preconditioning 0 0