VRM = 750 V Transient Voltage Suppressor AM01JB Data Sheet Description Package The AM01JB is high voltage diode for the ignition coil of automotive electronics unit, and have high surge capability. Axial (φ2.4 × 2.9L / φ0.49) Cathode Mark (2) (1) Features ● ● ● ● ● High Reliability Automotive Requirement High Surge Capability Flammability UL94V-0 (Equivalent) Compliant with RoHS Directive Not to Scale. ● VRM ------------------------------------------------------ 750 V ● IF(AV) -----------------------------------------------------10 mA ● VF ------------------------------------------------ 1.0 V (max.) Internal Schematic Diagram (1) Application (2) (1) Cathode (2) Anode ● Ignition coil of automotive electronics unit Typical Application Ignition Coil TVS diode AM01JB Primary Secondary Battery Spark GND AM01JB-DSE Rev.1.0 SANKEN ELECTRIC CO.,LTD. Jun. 13, 2016 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2016 1 AM01JB Absolute Maximum Ratings Unless specifically noted TA = 25 °C. Parameter Symbol Conditions Rating Unit 750 V 70 mA 10 mA 10 A −4 0 to 150 °C −4 0 to 150 °C Peak Repetitive Reverse Voltage VRM Surge Reverse Current IRSM Average Forward Current IF(AV) Surge Forward Current IFSM Junction Temperature Tj − See Figure 1. Single pulse. − Half cycle sine-wave, positive side, 10ms, one shot. − Storage Temperature Tstg − Electrical Characteristics Unless specifically noted, TA = 25 °C. Parameter Symbol Conditions Min. Typ. Max. Unit Forward Voltage Drop VF IF = 10 mA − − 1.0 V Reverse Leakage Current IR VR = VRM − − 10 μA Breakdown Voltage VZ IZ = 100 µA 850 − 1100 V Reverse Current, IR ΔIR ΔIR 2 IRSM 0 Time 50µs Figure 1 Definition of Surge Reverse Current, IRSM AM01JB-DSE Rev.1.0 SANKEN ELECTRIC CO.,LTD. Jun. 13, 2016 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2016 2 AM01JB Typical Characteristics 1 1.E-04 1.E-05 Reverse Current, IR (A) Forward Current, IF (A) TA = 150°C TA = 100°C 0.1 0.01 TA = 150°C 1.E-06 TA = 100°C 1.E-07 TA = 60°C 1.E-08 TA = 60°C 1.E-09 TA = 25°C TA = 25°C 0.001 0.0 0.2 0.4 0.6 0.8 1.E-10 1.0 0 Forward Voltage, VF (V) Figure 2 200 400 600 800 1000 Reverse Voltage, VR (V) IF-VF typical characteristics Figure 3 100 IR-VR typical characteristics 1100 TA = 60°C TA = 100°C 10 1050 Breakdown Voltage, VZ (V) Breakdown Current, IZ (µA) TA = 25°C 1000 950 IZ=100µA t = 5s 1 900 900 950 1000 1050 1100 0 IZ-VZ typical characteristics 100 150 Junction Temperature, Tj (°C) Breakdown Voltage, VZ (V) Figure 4 50 Figure 5 AM01JB-DSE Rev.1.0 SANKEN ELECTRIC CO.,LTD. Jun. 13, 2016 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2016 VZ-Tj typical characteristics 3 AM01JB Physical Dimensions Axial (φ2.4 × 2.9L / φ0.49) 62.0 ± 1.0 2.9 ± 0.1 ϕ 2.4 ± 0.1 ϕ0.49 ± 0.06 Notes ● Dimension is in millimeters. ● Lead treatment Pb-free. Device composition compliant with the RoHS directive. Marking Diagram Cathode Mark PR P is specific device code Y M R is V RM rank (See Table 1) Lot Number: Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N or D) Table 1 Specific Device Code and VRM Rank Specific Device Code VRM Rank Products J B AM01JB AM01JB-DSE Rev.1.0 SANKEN ELECTRIC CO.,LTD. Jun. 13, 2016 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2016 4 AM01JB IMPORTANT NOTES ● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. ● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically, chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● No contents in this document can be transcribed or copied without Sanken’s prior written consent. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the foregoing. ● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property rights or any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to any information contained in this document (including its accuracy, usefulness, or reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the contents included herein. ● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer to our official website in relation to general instructions and directions for using the Sanken Products. DSGN-AEZ-16001 AM01JB-DSE Rev.1.0 SANKEN ELECTRIC CO.,LTD. Jun. 13, 2016 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2016 5