am01jb ds en

VRM = 750 V
Transient Voltage Suppressor
AM01JB
Data Sheet
Description
Package
The AM01JB is high voltage diode for the ignition
coil of automotive electronics unit, and have high surge
capability.
Axial (φ2.4 × 2.9L / φ0.49)
Cathode Mark
(2)
(1)
Features
●
●
●
●
●
High Reliability
Automotive Requirement
High Surge Capability
Flammability UL94V-0 (Equivalent)
Compliant with RoHS Directive
Not to Scale.
● VRM ------------------------------------------------------ 750 V
● IF(AV) -----------------------------------------------------10 mA
● VF ------------------------------------------------ 1.0 V (max.)
Internal Schematic Diagram
(1)
Application
(2)
(1) Cathode
(2) Anode
● Ignition coil of automotive electronics unit
Typical Application
Ignition Coil
TVS diode
AM01JB
Primary
Secondary
Battery
Spark
GND
AM01JB-DSE Rev.1.0
SANKEN ELECTRIC CO.,LTD.
Jun. 13, 2016
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2016
1
AM01JB
Absolute Maximum Ratings
Unless specifically noted TA = 25 °C.
Parameter
Symbol
Conditions
Rating
Unit
750
V
70
mA
10
mA
10
A
−4 0 to 150
°C
−4 0 to 150
°C
Peak Repetitive Reverse Voltage
VRM
Surge Reverse Current
IRSM
Average Forward Current
IF(AV)
Surge Forward Current
IFSM
Junction Temperature
Tj
−
See Figure 1.
Single pulse.
−
Half cycle sine-wave,
positive side, 10ms,
one shot.
−
Storage Temperature
Tstg
−
Electrical Characteristics
Unless specifically noted, TA = 25 °C.
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
Forward Voltage Drop
VF
IF = 10 mA
−
−
1.0
V
Reverse Leakage Current
IR
VR = VRM
−
−
10
μA
Breakdown Voltage
VZ
IZ = 100 µA
850
−
1100
V
Reverse
Current, IR
ΔIR
ΔIR
2
IRSM
0
Time
50µs
Figure 1
Definition of Surge Reverse Current, IRSM
AM01JB-DSE Rev.1.0
SANKEN ELECTRIC CO.,LTD.
Jun. 13, 2016
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2016
2
AM01JB
Typical Characteristics
1
1.E-04
1.E-05
Reverse Current, IR (A)
Forward Current, IF (A)
TA = 150°C
TA = 100°C
0.1
0.01
TA = 150°C
1.E-06
TA = 100°C
1.E-07
TA = 60°C
1.E-08
TA = 60°C
1.E-09
TA = 25°C
TA = 25°C
0.001
0.0
0.2
0.4
0.6
0.8
1.E-10
1.0
0
Forward Voltage, VF (V)
Figure 2
200
400
600
800
1000
Reverse Voltage, VR (V)
IF-VF typical characteristics
Figure 3
100
IR-VR typical characteristics
1100
TA = 60°C
TA = 100°C
10
1050
Breakdown Voltage, VZ (V)
Breakdown Current, IZ (µA)
TA = 25°C
1000
950
IZ=100µA
t = 5s
1
900
900
950
1000
1050
1100
0
IZ-VZ typical characteristics
100
150
Junction Temperature, Tj (°C)
Breakdown Voltage, VZ (V)
Figure 4
50
Figure 5
AM01JB-DSE Rev.1.0
SANKEN ELECTRIC CO.,LTD.
Jun. 13, 2016
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2016
VZ-Tj typical characteristics
3
AM01JB
Physical Dimensions
Axial (φ2.4 × 2.9L / φ0.49)
62.0 ± 1.0
2.9 ± 0.1
ϕ 2.4 ± 0.1
ϕ0.49 ± 0.06
Notes
● Dimension is in millimeters.
● Lead treatment Pb-free. Device composition compliant with the RoHS directive.
Marking Diagram
Cathode Mark
PR
P is specific device code
Y
M
R is V RM rank (See Table 1)
Lot Number:
Y is the last digit of the year of manufacture (0 to 9)
M is the month of the year (1 to 9, O, N or D)
Table 1 Specific Device Code and VRM Rank
Specific Device Code
VRM Rank
Products
J
B
AM01JB
AM01JB-DSE Rev.1.0
SANKEN ELECTRIC CO.,LTD.
Jun. 13, 2016
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2016
4
AM01JB
IMPORTANT NOTES
● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the
“Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change
without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative
that the contents set forth in this document reflect the latest revisions before use.
● The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its
control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the
Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products
and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic
signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss
the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken
Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any
applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical
equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class
III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or
responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from
the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein.
● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically,
chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such
uses in advance and proceed therewith at your own responsibility.
● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the
occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility,
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which
the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human
injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer
to the relevant specification documents and Sanken’s official website in relation to derating.
● No anti-radioactive ray design has been adopted for the Sanken Products.
● No contents in this document can be transcribed or copied without Sanken’s prior written consent.
● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all
information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of
use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be
suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property
rights and any other rights of you, users or any third party, resulting from the foregoing.
● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference
of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property
rights or any other rights of Sanken.
● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,
including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty
of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is
delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course
of dealing or usage of trade, and (iv) as to any information contained in this document (including its accuracy, usefulness, or
reliability).
● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and
regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS
Directive, so as to be in strict compliance with such applicable laws and regulations.
● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including
but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical
Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each
country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan,
and follow the procedures required by such applicable laws and regulations.
● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including
the falling thereof, out of Sanken’s distribution network.
● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting
from any possible errors or omissions in connection with the contents included herein.
● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer
to our official website in relation to general instructions and directions for using the Sanken Products.
DSGN-AEZ-16001
AM01JB-DSE Rev.1.0
SANKEN ELECTRIC CO.,LTD.
Jun. 13, 2016
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2016
5