SJPL-L4

http://www.sanken-ele.co.jp
SANKEN ELECTRIC
SJPL-L4
May. 2016
Fast Recovery Diode
General Description
Package
SJPL-L4 realizes low leakage current at high
temperature. High efficiency is achieved by reducing the
loss of circuit at high temperature.
SJP
(2)
(2)
(1)
Applications
(1)
・DC-DC converters
・AC adapter
・High frequency rectification circuit
(1) Cathode
(2) Anode
Not to Scale
Key Specifications
Features
Item
Rating
Unit
・ Super-high speed FRD
・ Low leakage current at high temperature
VRM
400
V
VF
1.3
V
IF(AV)
3.0
A
trr
35
ns
Conditions
IF=3.0A
100mA/200mA
Typical Characteristics
Characteristics
SJPL-L4 VR-IR代表特性
Characteristics
SJPL-L4 IF-VF 代表特性
100
1.E-04
150°C
150°C
1.E-05
10
1.E-06
100°C
100°C
IR[A]
IF [A]
1
1.E-07
150°C
150°C
0.1
60°C
60°C
100°C
100°C
1.E-08
60°C
60°C
0.01
25°C
25°C
25°C
25°C
1.E-09
0.001
1.E-10
0.0
0.5
1.0
1.5
2.0
0
50
100
150
200
250
300
350
400
VR[V]
VF [V]
The information included herein is believed to be accurate and reliable. However, SANKEN ELECTRIC CO., LTD assumes no responsibility for its use ; nor for any
infringements of patents or other rights of third parties that may result from its use.
Copy Right: SANKEN ELECTRIC CO.,LTD.
Page1
http://www.sanken-ele.co.jp
SANKEN ELECTRIC
SJPL-L4
May. 2016
Fast Recovery Diode
Absolute maximum ratings
No.
Item
Symbol
Unit
Rating
Conditions
1
Transient Peak Reverse Voltage
VRSM
V
400
2
Peak Reverse Voltage
VRM
V
400
3
Average Forward Current
IF(AV)
A
3.0
4
Peak Surge Forward Current
IFSM
A
30
Half sine-wave, one shot
5
I2t Limiting Value
I2t
A2s
4.5
1ms ≤ t ≤ 10ms
6
Junction Temperature
Tj
°C
-40 to 150
7
Storage Temperature
Tstg
°C
-40 to 150
Electrical characteristics (Ta=25°C, unless otherwise specified)
No.
Item
Symbol
Unit
Value
Conditions
1
Forward Voltage Drop
VF
V
1.3 max.
IF=3.0A
2
Reverse Leakage Current
IR
µA
50 max.
VR=VRM
H・IR
µA
100 max.
trr1
ns
50 max.
IF=IRP=100mA
90% Recovery point, Tj=25°C
trr2
ns
35 max.
IF=100mA,IRP=200mA
75% Recovery point, Tj=25°C
Rth(j-c)
°C /W
20 max.
3
4
5
Reverse Leakage Current Under
High Temperature
Reverse Recovery Time
Thermal Resistance
Copy Right: SANKEN ELECTRIC CO.,LTD.
Page 2
VR=VRM, Tj=150°C
Between Junction and Lead
http://www.sanken-ele.co.jp
SANKEN ELECTRIC
SJPL-L4
May. 2016
Fast Recovery Diode
Characteristics
Forward Power Dissipation PF PF (W)
Forward Power Dissipation
5
Tj=150℃
t/T=1/6
4
t
T
t/T=1/3,sinewave
3
t/T=1/2
2
DC
1
0
0
1
2
3
Average Forward Current IF(AV) (A)
Average Forward Current IF(AV) (A)
Current Derating
VR=0V
3
t/T=1/6
DC
t/T=1/3,sinewave
2
t/T=1/2
1
Tj=150℃
t
T
0
0
50
100
Lead temperature TL (°C)
Copy Right: SANKEN ELECTRIC CO.,LTD.
Page 3
150
http://www.sanken-ele.co.jp
SANKEN ELECTRIC
SJPL-L4
Fast Recovery Diode
Outline drawings
● SJP
NOTES:
● Dimension is in millimeters.
● Lead treatment Pb-free. Device composition compliant with the RoHS directive.
Connection Diagram
1
2
Copy Right: SANKEN ELECTRIC CO.,LTD.
Page 4
May. 2016
http://www.sanken-ele.co.jp
SANKEN ELECTRIC
SJPL-L4
May. 2016
Fast Recovery Diode
IMPORTANT NOTES
● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein
(the “Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change
without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative
that the contents set forth in this document reflect the latest revisions before use.
● The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home
appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products,
please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to
Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation
equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety
devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix
your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the
Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as:
aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result
in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan
(collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and
losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific
Applications or in manner not in compliance with the instructions set forth herein.
● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically,
chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such
uses in advance and proceed therewith at your own responsibility.
● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the
occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility,
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which
the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any
human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products.
Please refer to the relevant specification documents and Sanken’s official website in relation to derating.
● No anti-radioactive ray design has been adopted for the Sanken Products.
● No contents in this document can be transcribed or copied without Sanken’s prior written consent.
● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all
information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference
of use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be
suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property
rights and any other rights of you, users or any third party, resulting from the foregoing.
● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference
of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property
rights or any other rights of Sanken.
● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,
including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty
of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is
delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course
of dealing or usage of trade, and (iv) as to any information contained in this document (including its accuracy, usefulness, or
reliability).
● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and
regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS
Directive, so as to be in strict compliance with such applicable laws and regulations.
● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including
but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical
Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each
country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan,
and follow the procedures required by such applicable laws and regulations.
● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including
the falling thereof, out of Sanken’s distribution network.
● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting
from any possible errors or omissions in connection with the contents included herein.
● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer
to our official website in relation to general instructions and directions for using the Sanken Products.
DSGN-CEZ-16001
Copy Right: SANKEN ELECTRIC CO.,LTD.
Page 5