http://www.sanken-ele.co.jp SANKEN ELECTRIC SJPX-H6 May. 2016 Fast Recovery Diode General Description Package SJPX-H6 has the characteristics of low VF and superior trr at high temperature. High efficiency is achieved by reducing the loss of circuit at high temperature. SJP (2) Applications (2) (1) ・DC-DC converters ・AC adapter ・High frequency rectification circuit (1) (1) Cathode (2) Anode Not to Scale Key Specifications Features Item Rating Unit ・ Super-high speed FRD ・ Low leakage current at high temperature VRM 600 V VF 1.5 V IF(AV) 2.0 A trr 20 ns Conditions IF=2.0A 100mA/200mA Typical Characteristics Characteristics SJPX-H6 VR-IR代表特性 SJPX-H6 IF-VF 代表特性 Characteristics 100 1.E-02 150°C 10 1.E-03 1 1.E-04 125°C 100°C IR[A] IF [A] 150°C 125°C 0.1 1.E-05 100°C 25°C 25°C 0.01 1.E-06 0.001 1.E-07 0.0 0.5 1.0 1.5 2.0 2.5 0 100 200 300 400 500 600 VR[V] VF [V] The information included herein is believed to be accurate and reliable. However, SANKEN ELECTRIC CO., LTD assumes no responsibility for its use ; nor for any infringements of patents or other rights of third parties that may result from its use Copy Right: SANKEN ELECTRIC CO.,LTD. Page1 http://www.sanken-ele.co.jp SANKEN ELECTRIC SJPX-H6 May. 2016 Fast Recovery Diode Absolute maximum ratings No. Item Symbol Unit Rating Conditions 1 Transient Peak Reverse Voltage VRSM V 600 2 Peak Reverse Voltage VRM V 600 3 Average Forward Current IF(AV) A 2.0 4 Peak Surge Forward Current IFSM A 20 Half sine-wave, one shot 5 I2t Limiting Value I2t A2s 2.0 1ms ≤ t ≤ 10ms 6 Junction Temperature Tj °C -40 to 150 7 Storage Temperature Tstg °C -40 to 150 Electrical characteristics (Ta=25°C, unless otherwise specified) No. Item Symbol Unit Value Conditions 1 Forward Voltage Drop VF V 1.5 max. IF=2.0A 2 Reverse Leakage Current IR uA 10 max. VR=VRM H・IR mA 3.0 max. VR=VRM, Tj=150°C trr1 ns 30 max. IF=IRP=100mA 90% Recovery point, Tj=25°C trr2 ns 20 max. IF=100mA,IRP=200mA 75% Recovery point, Tj=25°C Rth(j-c) °C /W 20 max. 3 4 5 Reverse Leakage Current Under High Temperature Reverse Recovery Time Thermal Resistance Copy Right: SANKEN ELECTRIC CO.,LTD. Page2 Between Junction and Lead http://www.sanken-ele.co.jp SANKEN ELECTRIC SJPX-H6 May. 2016 Fast Recovery Diode Characteristics Forward Power Dissipation Forward Power Dissipation PF (W) 4 Tj=150℃ t/T=1/6 t/T=1/3,sinewave 3 t T t/T=1/2 2 DC 1 0 0.0 0.5 1.0 1.5 2.0 Average Forward Current IF(AV) (A) Reverse Power Dissipation PR (W) Reverse Power Dissipation 1.5 Tj=150℃ t T 1 t/T=1/6 t/T=1/3,sinewave 0.5 t/T=1/2 DC 0 0 100 200 300 400 500 600 Reverse Voltage VR (V) Average Forward Current IF(AV) (A) Current Derating VR=0V 2.0 Tj=150℃ 1.5 t/T=1/6 DC t T t/T=1/3,sinewave 1.0 t/T=1/2 0.5 0.0 0 50 100 Lead temperature TL (°C) Copy Right: SANKEN ELECTRIC CO.,LTD. Page3 150 http://www.sanken-ele.co.jp SANKEN ELECTRIC SJPX-H6 Fast Recovery Diode External Dimensions SJP NOTES: ● Dimension is in millimeters. ● Lead treatment Pb-free. Device composition compliant with the RoHS directive. Connection Diagram 1 2 Copy Right: SANKEN ELECTRIC CO.,LTD. Page4 May. 2016 http://www.sanken-ele.co.jp SANKEN ELECTRIC SJPX-H6 May. 2016 Fast Recovery Diode IMPORTANT NOTES ● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. ● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically, chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● No contents in this document can be transcribed or copied without Sanken’s prior written consent. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the foregoing. ● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property rights or any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to any information contained in this document (including its accuracy, usefulness, or reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the contents included herein. ● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer to our official website in relation to general instructions and directions for using the Sanken Products. DSGN-CEZ-16001 Copy Right: SANKEN ELECTRIC CO.,LTD. Page5