DK VDE 1a 10A, 1a1b/2a 8A small polarized power relays RoHS compliant DK RELAYS FEATURES TYPICAL APPLICATIONS 1. Compact with high capacity High capacity switching in a small package: 1 Form A, 10 A 250 V AC; 1 Form A 1 Form B and 2 Form A, 8 A 250 V AC. 2. High sensitivity: 200 mW nominal operating power 3. High breakdown voltage Independent coil and the contact structure improves breakdown voltage. 1. Switching power supply 2. Power switching for various OA equipment 3. Control or driving relays for industrial machines (robotics, numerical control machines, etc.) 4. Output relays for programmable logic controllers, temperature controllers, timers and so on. 5. Home appliances Between contact and coil 4,000 Vrms for 1 min. 10,000 V surge breakdown voltage Between open contacts 1,000 Vrms for 1 min. 1,500 V surge breakdown voltage Conforms with FCC Part 68 4. Latching types available 5. Sealed construction allows automatic washing. 6. Sockets are available 7. Complies with safety standards Complies with Japan Electrical Appliance and Material Safety Law requirements for operating 200 V power supply circuits, and complies with UL, CSA, and TÜV safety standards. ORDERING INFORMATION DK Contact arrangement 1a: 1 Form A 2a: 2 Form A 1a1b: 1 Form A 1 Form B Operating function Nil: Single side stable L2: 2 coil latching Nominal coil voltage (DC) 3, 5, 6, 9, 12, 24V Contact material F: 1 Form A (AgSnO2 type) Nil: 2 Form A, 1 FormA 1 Form B (Au-flashed AgNi type) Notes: 1. Certified by UL, CSA and TÜV 2. VDE approved type is available. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB177E 201202-T DK TYPES 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. DK1a-3V-F DK1a-5V-F DK1a-6V-F DK1a-9V-F DK1a-12V-F DK1a-24V-F 2 coil latching Part No. DK1a-L2-3V-F DK1a-L2-5V-F DK1a-L2-6V-F DK1a-L2-9V-F DK1a-L2-12V-F DK1a-L2-24V-F 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC DK1a1b-3V DK1a1b-5V DK1a1b-6V DK1a1b-9V DK1a1b-12V DK1a1b-24V DK2a-3V DK2a-5V DK2a-6V DK2a-9V DK2a-12V DK2a-24V DK1a1b-L2-3V DK1a1b-L2-5V DK1a1b-L2-6V DK1a1b-L2-9V DK1a1b-L2-12V DK1a1b-L2-24V DK2a-L2-3V DK2a-L2-5V DK2a-L2-6V DK2a-L2-9V DK2a-L2-12V DK2a-L2-24V Contact arrangement Nominal coil voltage 1 Form A 1 Form A 1 Form B 2 Form A Standard packing: Carton: 50 pcs.; Case: 500 pcs. * For sockets, see page 123. RATING 1. Coil data 1) Single side stable 3V DC Nominal operating current [±10%] (at 20°C 68°F) 66.6mA 5V DC 6V DC 9V DC 12V DC 24V DC 40mA 33.3mA 22.2mA 16.6mA 8.3mA Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 200mW 130%V of nominal voltage 45Ω 125Ω 180Ω 405Ω 720Ω 2,880Ω 2) 2 coil latching Nominal coil voltage 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC 70%V or less of nominal voltage (Initial) ASCTB177E 201202-T 70%V or less of nominal voltage (Initial) Panasonic Corporation Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil Coil resistance [±10%] (at 20°C 68°F) Set coil Reset coil 66.6mA 66.6mA 45Ω 45Ω 40mA 33.3mA 22.2mA 16.6mA 8.3mA 40mA 33.3mA 22.2mA 16.6mA 8.3mA 125Ω 180Ω 405Ω 720Ω 2,880Ω 125Ω 180Ω 405Ω 720Ω 2,880Ω Automation Controls Business Unit Nominal operating power Set coil Reset coil 200mW 200mW Max. applied voltage (at 20°C 68°F) 130%V of nominal voltage industrial.panasonic.com/ac/e/ DK 2. Specifications Characteristics Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Contact Rating Specifications 1 Form A 1 Form B 2 Form A Max. 30 mΩ (By voltage drop 6 V DC 1A) Au-flashed AgSnO2 type Au-flashed AgNi type 10 A 250 V AC, 10 A 30 V DC 8 A 250 V AC,8 A 30 V DC 8 A 250 V AC,8 A 30 V DC 2,500VA, 300 W 2,000 VA, 240 W 2,000 VA, 240 W 250 V AC, 125 V DC 250 V AC, 125 V DC 250 V AC, 125 V DC 10 A 8A 8A 200 mW 10m A 5 V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. 1 Form A Between open contacts Between contact and coil Breakdown voltage (Initial) 1,000 Vrms for 1min. (Detection current: 10mA.) 4,000 Vrms for 1min. (Detection current: 10mA.) Surge breakdown between contacts and coil voltage*2 (Initial) Temperature rise (coil) (at 65°C 149°F) Electrical characteristics 10,000 V Max. 40°C (By resistive method, nominal voltage applied to the coil; max. switching current) Max. 10 ms (Approx. 5 ms) [10 ms (Approx. 5 ms)] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 8 ms (Approx. 3 ms) [10 ms (Approx. 3 ms)] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 3 mm Min. 5×107 (at 300 times/min.) Min. 105 (resistive load, at 20 times/min., at rated capacity) Ambient temperature: –40°C to +65°C –40°F to +149°F, Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. Approx. 5 g .18 oz Approx. 6 g .21 oz Approx. 6 g .21 oz Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical Shock resistance Mechanical characteristics Expected life Conditions for operation, transport and storage*3 Conditions Max. operating speed (at rated load) Unit weight Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1-(1). Maximum operating power (1 Form A) 1-(2). Maximum operating power (1 Form A 1 Form B, 2 Form A) 2-(1). Life curve (1 Form A) 1,000 1 AC resistive load DC inductive load (L/R = 7 ms) 0.1 10 DC resistive load 100 Contact voltage, V AC inductive load (cosϕ = 0.4) AC resistive load 10 5 1 DC inductive load (L/R = 7 ms) 0.1 1,000 Life, ×104 AC inductive load (cosϕ = 0.4) 10 Contact current, A Contact current, A 100 10 100 DC resistive load 100 250 V AC resistive load 30 V DC resistive load 10 1 1,000 250 V AC inductive load (cosϕ = 0.4) 30 V DC inductive load (L/R = 7 ms) 0 1 2 3 4 Contact voltage, V 2-(2). Life curve (1 Form A 1 Form B, 2 Form A) 5 6 7 8 9 10 Contact current, A 3-(1). Operate/Release time (1 Form A) Tested sample: DK1a-24V, 5 pcs. 3-(2). Operate/Release time (1 Form A 1 Form B, 2 Form A) Tested sample: DK1a1b-12V, 5 pcs. 1,000 9 9 250 V AC resistive load 30 V DC resistive load 10 250 V AC inductive load (cosϕ = 0.4) 30 V DC inductive load (L/R = 7 ms) Operate time 7 6 5 4 Release time (with diode) 3 0 1 2 3 4 5 6 7 8 9 10 Contact current, A Panasonic Corporation 0 Max. x Max. x Min. Min. Max. x Min. 2 1 1 Operate/release time, ms Operate/release time, ms Life, ×104 100 Release time (with diode) 8 8 90 10 110 120 130 6 5 4 3 Release time 1 140 0 80 90 Coil applied voltage,%V Automation Controls Business Unit Max. x Min. Max. x Min. Operate time 2 Release time 80 Max. x Min. 7 industrial.panasonic.com/ac/e/ 10 110 120 130 140 Coil applied voltage,%V ASCTB177E 201202-T DK 50 40 10A 7A 5A 0A 30 20 10 0 80 90 4-(2). Coil temperature rise (1 Form A 1 Form B, 2 Form A) 5-(1). Ambient temperature characteristics (1 Form A) Tested sample: DK1a1b-12V, 5 pcs. Ambient temperature: 20°C 68°F Tested sample: DK1a-24V, 6 pcs Ambient temperature: –40°C to +80°C –40°F to +176°F Coil temperature rise, °C Coil temperature rise, °C Tested sample: DK1a-12V, 5 pcs. Ambient temperature: 30°C 86°F 50 40 8A 5A 0A 30 130 110 100 -40 -20 0 20 90 10 80 80 90 Drop-out voltage 120 20 0 100 110 120 130 Coil applied voltage,%V Variation ratio, % 4-(1). Coil temperature rise (1 Form A) Pick-up voltage 40 60 80 Ambient temperature, °C 70 100 110 120 130 Coil applied voltage,%V Variation ratio, % 5-(2). Ambient temperature characteristics (1 Form A 1 Form B, 2 Form A) –40 –20 Pick-up voltage 130 120 110 0 100 40 60 20 90 80 80 Ambient temperature,°C Drop-out voltage 70 DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. 1 Form A type CAD Data External dimensions PC board pattern (Bottom view) Single side stable type 20 .787 12.5 .492 2.54 .100 7.62 .300 7.62 .300 1.1 dia. .043 dia. Single side stable 1 - 9.7 .382 0.3 .012 Schematic (Bottom view) 3.5 .138 0.4 .016 0.8 .031 7.62 .300 0.4 .016 0.8 .031 1.11 .044 1.2 .047 10.16 .400 6 (Deenergized condition) 10.16 .400 2 coil latching type 2 coil latching 20 .787 12.5 .492 2.54 .100 7.62 .300 7.62 .300 9.7 .382 3.5 .138 0.4 .016 2.54 .100 0.4 .016 7.62 .300 0.8 .031 7.62 .300 0.4 .016 0.8 .031 1.11 .044 1.2 .047 General tolerance: ±0.3 ±.012 ASCTB177E 201202-T 4 + 10.16 .400 0.3 .012 3 Panasonic Corporation 10.16 .400 1.1 dia. .043 dia. 1 - 3 + + 6 5 4 (Reset condition) 10.16 .400 Tolerance: ±0.1 ±.004 Automation Controls Business Unit Since this is a polarized relay, the connection to the coil should be done according to the above schematic. industrial.panasonic.com/ac/e/ DK 2. 1 Form A 1 Form B type, 2 Form A type External dimensions CAD Data PC board pattern (Bottom view) Single side stable type 20 .787 15 .591 10.16 .400 7.62 .300 1.1 dia. .043 dia. 9.7 .382 0.3 .012 0.4 .016 Schematic (Bottom view) <1 Form A 1 Form B type> Single side stable 1 - 0.8 .031 10.16 .400 7.62 .300 3.5 .138 0.8 .031 2.42 1.11 .044 .095 10.16 .400 10.16 .400 3 4 6 5 + 0.4 .016 8 (Deenergized condition) 2 coil latching 2 coil latching type 20 .787 15 .591 2.54 .100 7.62 .300 7.62 .300 1.1 dia. .043 dia. 9.7 .382 0.3 .012 0.4 .016 2.54 .100 0.6 .024 7.62 .300 0.8 .031 7.62 .300 3.5 .138 0.8 .031 2.42 1.11 .044 .095 + + 8 7 4 6 5 <2 Form A> Single side stable 0.4 .016 1 - General tolerance: ±0.3 ±.012 3 (Reset condition) 10.16 .400 10.16 .400 1 - Tolerance: ±0.1 ±.004 3 4 6 5 + 8 (Deenergized condition) 2 coil latching 1 + + 8 7 3 4 6 5 (Reset condition) Since this is a polarized relay, the connection to the coil should be done according to the above schematic. SAFETY STANDARDS Item 1 Form A 1 Form A 1 Form B, 2 Form A UL/C-UL (Recognized) File No. Contact rating E43028 10A 250V AC 1/3HP 125, 250V AC 10A 30V DC E43028 8A 250V AC 1/4HP 125, 250V AC 8A 30V DC CSA (Certified) File No. Contact rating LR26550 10A 250V AC 1/3HP 125, 250V AC etc. 10A 30V DC LR26550 8A 250V AC 1/4HP 125, 250V AC etc. 8A 30V DC VDE (Certified) File No. Contact rating 006099UG AC 250V 10A (cosφ =1.0) AC 250V 5A (cosφ =0.4) DC 30V 10A (0ms) 006099UG 1 Form A 1 Form B: AC 250V 8A (cosφ =1.0) 2 Form A: AC 250V 8A (cosφ =1.0) AC 250V 4A (cosφ =0.4) TÜV (Certified) Rating 8705 10A 250V AC (cosφ =1.0) 1645 520 5A 250V AC (cosφ =0.4) 10A 30V DC 8705 1645 8A 250V AC (cosφ =1.0) 4A 250V AC (cosφ =0.4) 520 (1 Form A 8A 30V DC 1 Form B) 9407 13461 097 (2 Form A) File No. NOTES 1. Soldering should be done under the following conditions: 250°C 482°F within 10s 300°C 572°F within 5s 350°C 662°F within 3s Soldering depth: 2/3 terminal pitch 2. External magnetic field Since DK relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 3. When using, please be aware that the a contact and b contact sides of 1 Form A and 1 Form B types may go on simultaneously at operate time and release time. For Cautions for Use. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB177E 201202-T