PANASONIC JS1A-6V-F

JS
VDE
1a/1c 10A cubic type
power relays
RoHS compliant
JS RELAYS
FEATURES
TYPICAL APPLICATIONS
• Miniature size with universal terminal
footprint
• High contact capacity: 10 A
• TV-5 type available (Standard type)
1 Form A type → TV-5
1 Form C type → TV-5 (N.O. side only)
• VDE, TÜV also approved
• Sealed construction for automatic
cleaning (Standard type)
• Class B and F coil insulation type
also available.
• EN60335-1 GWT compliant (Tested
by VDE) type available
• Surge voltage 6 kV type also
available
1. Home appliances
Air conditioner, heater, etc.
2. Office machines
PPC, facsimile, etc.
3. Vending machines
ORDERING INFORMATION
JS
F
Contact arrangement
1:
1 Form C (Standard)
1a: 1 Form A (Standard)
1aP: 1 Form A (Long endurance type)
Protective construction
Nil: Sealed type
F: Flux-resistant type
Coil insulation class
Nil: Class E insulation
B: Class B insulation
F: Class F insulation
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V
Contact material
F: AgSnO2 type
Flame resistance and tracking resistance
Nil: –
T: EN60335-1 (Conform)
Surge voltage
6K: 6kV type
Standard: UL, CSA, VDE, TÜV (Standard type)
UL, CSA, VDE (Long endurance type and EN60335-1 GWT compliant type)
UL, CSA (Surge voltage 6kV type)
Notes: 1. When ordering TV rated (TV-5) types, please consult us.
2. Contact arrangement 1aP type is Flux-resistant type only (Class B insulation only).
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB186E 201202-T
JS
TYPES
Contact arrangement
Nominal coil voltage
Sealed type
Part No.
Flux-resistant type
Part No.
1 Form A
(Standard)
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
JS1a-5V-F
JS1a-6V-F
JS1a-9V-F
JS1a-12V-F
JS1a-18V-F
JS1a-24V-F
JS1a-48V-F
JS1aF-5V-F
JS1aF-6V-F
JS1aF-9V-F
JS1aF-12V-F
JS1aF-18V-F
JS1aF-24V-F
JS1aF-48V-F
1 Form A
Long endurance type
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
–
–
–
–
–
–
–
JS1aPF-B-5V-F
JS1aPF-B-6V-F
JS1aPF-B-9V-F
JS1aPF-B-12V-F
JS1aPF-B-18V-F
JS1aPF-B-24V-F
JS1aPF-B-48V-F
1 Form C
(Standard)
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
JS1-5V-F
JS1-6V-F
JS1-9V-F
JS1-12V-F
JS1-18V-F
JS1-24V-F
JS1-48V-F
JS1F-5V-F
JS1F-6V-F
JS1F-9V-F
JS1F-12V-F
JS1F-18V-F
JS1F-24V-F
JS1F-48V-F
Standard packing Carton: 100 pcs. Case: 500 pcs.
Notes: 1. Class B and F coil insulation types available.
Ex) JS1aF-B-12V-F, JS1aF-F-12V-F
2. EN60335-1 GWT compliant types available. When ordering, please add suffix “T”.
Ex) JS1aF-B-12V-FT
3. Surge voltage 6kV types available. When ordering, please add suffix “6K” (except for Long endurance type and EN60335-1 GWT compliant type).
Ex) JS1aF-B-12V-F-6K
RATING
1. Coil data
Nominal coil
voltage
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
72 mA
60 mA
40 mA
30 mA
20 mA
15 mA
7.5mA
69.4Ω
100 Ω
225 Ω
400 Ω
900 Ω
1,600 Ω
6,400 Ω
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
130%V of
nominal voltage
360mW
[When using relays at
85°C 185°F, see Note*]
Note: * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
ASCTB186E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
JS
2. Specifications
Characteristics
Contact
Item
Contact material
Contact resistance (Initial)
Arrangement
Specifications
AgSnO2 type
Max. 100 mΩ (By voltage drop 6 V DC 1A)
1 Form A, 1 Form C
1 Form A Long endurance type
10 A 250 V AC (NO), 10 A 125 V AC,
10 A 250 V AC, 10 A 277 V AC, 5 A 30 V DC
6 A 277 V AC, 5 A 30 V DC
2,500VA 150W (NO), 1,662VA 150W (NC)
2,770VA 150W
250V AC, 100V DC (0.5A)
10A (AC), 5A (DC)
360mW
100mA, 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity*1
Insulation resistance (Initial)
Rating
Breakdown voltage
(Initial)
Electrical
characteristics
Between open contacts
Between contact and coil
750 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
Max. 35°C 95°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 10A, at 70°C 158°F)
Max. 10 ms (excluding contact bounce time.)
Max. 10 ms (excluding contact bounce time) (Without diode)
98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Min. 107
Temperature rise (coil)
Operate time (at nominal voltage) (at 20°C 68°F)
Release time (at nominal voltage) (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions
1×105
[10A 125V AC, 6A 277V AC, 5A 30V DC]
5×104 (NO contact only)
[10A 250V AC]
Electrical (resistive load)
2×105
[10A 277V AC]
1.5×105
[10A 250V AC (at 20 times/min., 105°C 221°F)]
1×105
[5A 30V DC]
–40°C to +70°C –40°F to +158°F
(Class E insulation)
–40°C to +85°C –40°F to +185°F
–40°C to +105°C –40°F to +221°F*3;
(Class B insulation)*3
Humidity: 5 to 85% R.H. (Not freezing and
–40°C to +105°C –40°F to +221°F
condensing at low temperature)
(Class F insulation)*3
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 12 g .423 oz
Conditions for operation, transport and storage*2
Max. operating speed
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*3. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
REFERENCE DATA
1. Maximum value for switching capacity
2.-(1) Coil temperature rise
2.-(2) Coil temperature rise
Sample: 5 pcs., JS1a-24V-F
Measured portion: Inside the coil
Contact current: 5 A
Sample: 5 pcs., JS1a-24V-F
Measured portion: Inside the coil
Contact current: 10 A
60
100
60
10
1
DC resistive load
10
30
100
Contact voltage, V
Panasonic Corporation
26°C
70°C
85°C
40
30
Temperature rise, °C
AC resistive load
Temperature rise, °C
Contact current, A
26°C
50
50
40
30
20
20
10
10
0
100
120
140
Coil applied voltage, %V
Automation Controls Business Unit
160
70°C
85°C
0
100
120
140
160
Coil applied voltage, %V
industrial.panasonic.com/ac/e/
ASCTB186E 201202-T
JS
3. Life curve
4. Operate/release time
5. Ambient temperature characteristics
Ambient temperature: Room temperature
Sample: 25 pcs., JS1-12V-F
Sample: 6 pcs., JS1-12V-F
Life, ×104
125V AC resistive load
10
Changing
ration, %
Operate/release time, ms
100
10
Operate time
8
10
6
20 40 60 80
4
1
2
3
4
5
6
7
8
9
0
10
80
Contact current, A
100
–20
140
Coil applied voltage, %V
DIMENSIONS (mm inch)
The CAD data of the products with a
External dimensions
CAD Data
120
Ambient
temperature °C
–10
Max.
–
x
Min.
Max.
–
x
Min.
Release time
0
Drop-out voltage
–60 –40 –20 0
2
1
Pick-up voltage
20
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Schematic
(Bottom view)
1 Form A
N.O.
16
.630
0.4
.016
PC board pattern
(Bottom view)
1 Form A
(Standard, High Power)
4-1.3 dia.
4-.051 dia.
COM
COIL
3.9
.154
0.24
.009
12
.472
0.8
.031
0.8
.031
1 Form C
N.O.
0.4
.016
2
16
.630
1.2
.047
2.3
.091
COIL
12.2
.480
1 Form C
3 N.O.
12
.472
1
2
.079
COM
N.C.
(Standard)
4 N.C.
5
5-1.3 dia.
5-.051 dia.
0.4
.016
2
.079
12.2
.480
22
.866
12
.472
Note: Terminal No. 4 is only for Standard
1 Form C type
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
2
.079
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
12.2
.480
Tolerance: ±0.1 ±.004
SAFETY STANDARDS
File No.
E43028
UL/C-UL (Recognized)
Contact rating
10A 125V AC, 6A 277V AC
5A 30V DC, 1/8HP 125V AC
1/8HP 277V AC
12A 125V AC
12A 277V AC
10A 125V AC (N.O., 85°C)
4FLA/4LRA125V AC 105°C
(N.O.)
2FLA/4LRA125V AC 105°C
(N.C.)
1/3HP 277V AC 75°C N.O.
CSA (Certified)
File No.
Contact rating
LR26550
10A 125V AC
12A 125V AC
6A 277V AC
12A 277V AC
5A 30V DC
1/8HP 125V AC
1/8HP 277V AC
File No.
40011475
VDE (Certified)
Contact rating
10A 125V AC (cosφ =1.0)
6A 250V AC (cosφ =1.0)
TV rating (UL/CSA)
File No.
Rating
UL
1a➝TV-5
E43028
1c➝TV-5 (N.O.)
CSA
LR26550
TÜV (Certified)
File No.
Rating
B 10 02
10A 125V AC (cosφ =1.0)
13461 271 6A 250V AC (cosφ =1.0)
For Cautions for Use.
ASCTB186E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/