PANASONIC AQY272

PD 1 Form A (AQY27❍)
VDE
Flat Power-DIP4-pin type
with high capacity
up to 2A load current
8.8
.346
9.3
.366
3.9
.154
8.8
.346
9.3
.366
3.7
.146
mm inch
1
4
2
3
PD 1 Form A
(AQY27❍)
FEATURES
TYPICAL APPLICATIONS
1. Flat-Packaged type
(W) 8.8 × (D) 9.3 × (H) 3.9 mm
(W) .346 × (D) .366 × (H) .154 inch
2. High capacity of continuous load
current 2A (AQY272)
3. High sensitivity and low onresistance
Max. 2A load can be controlled with 5mA
input current. The on-resistance is low at
typ. 0.11Ω (AQY272).
• Measuring and Testing equipment
• IC Testers and Board Testers
• High speed inspection machines
RoHS compliant
TYPES
Output rating*
Type
AC/DC
dual use
Part No.
Through hole
terminal
Package
Packing quantity
Surface-mount terminal
Load
voltage
Load
current
60V
2.0A
AQY272
AQY272A
AQY272AX
AQY272AZ
100V
200V
400V
1.3A
0.65A
0.35A
AQY275
AQY277
AQY274
AQY275A
AQY277A
AQY274A
AQY275AX
AQY277AX
AQY274AX
AQY275AZ
AQY277AZ
AQY274AZ
Tube packing style
Power-DIP4-pin
Tape and reel packing style
Picked from the
Picked from the
1/2-pin side
3/4-pin side
Tube
Tape and reel
1 tube contains:
50 pcs.
1 batch contains:
1,000 pcs.
1,000 pcs.
* Indicate the peak AC and DC values.
Note: The surface mount terminal indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
Continuous load current
Peak load current
Power dissipation
Input
Output
Total power dissipation
I/O isolation voltage
Temperture limits
Operating
Storage
Panasonic Corporation
Symbol
IF
VR
IFP
Pin
VL
IL
Ipeak
Pout
PT
Viso
Topr
Tstg
AQY272(A)
AQY275(A) AQY277(A) AQY274(A)
50 mA
5V
1A
75 mW
60 V
100 V
200 V
400 V
2.0 A
1.3 A
0.65 A
0.35 A
6.0 A
4.0 A
2.0 A
1.0 A
700 mW
750 mW
2,500 V AC
–40°C to +85°C –40°F to +185°F
–40°C to +100°C –40°F to +212°F
Automation Controls Business Unit
Remarks
f = 100 Hz, Duty factor = 0.1%
Peak AC, DC
100ms (1 shot), VL = DC
Non-condensing at low temperatures
industrial.panasonic.com/ac/e/
ASCTB36E 201201-T
PD 1 Form A (AQY27❍)
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
Item
Symbol
Typical
LED operate current
Input
LED dropout voltage
On resistance
Output
VF
Ron
Initial I/O isolation resistance
Maximum
Typical
Maximum
Typical
Maximum
Typical
Maximum
Minimum
Maximum operating speed
Maximum
Turn on time*
Turn off time*
I/O capacitance
AQY275(A) AQY277(A)
1.0 mA
0.11 Ω
0.9 mA
1.25 V (1.16 V at IF = 10 mA)
1.5 V
0.23 Ω
0.7 Ω
0.18 Ω
0.34 Ω
2.46 ms
2.40 ms
Toff
5.64 ms
0.22 ms
IL = 100 mA
VL = 10 V
IF = 50 mA
2.1 Ω
IF = 10 mA, IL = Max.
Within 1 s on time
1.1 Ω
3.2 Ω
1.12 ms
1.65 ms
IF = 10 mA, IL = 100 mA
VL = 10 V
3.88 ms
IF = 5 mA, IL = 100 mA
VL = 10 V
0.08 ms
IF = 5 mA or 10 mA, IL = 100 mA
VL = 10 V
IF = 0 mA, VL = Max.
5.0 ms
5.65 ms
2.57 ms
10.0 ms
0.21 ms
0.10 ms
3.0 ms
0.8 pF
Ciso
Condition
IL = 100 mA
VL = 10 V
10 µA
ILeak
Ton
AQY274(A)
3.0 mA
0.4 mA
IFoff
Maximum
Maximum
Typical
Off state leakage current
Transfer
characteristics
IFon
Maximum
Minimum
Typical
Typical
Maximum
Typical
LED turn off current
AQY272(A)
Riso
1.5 pF
1,000 MΩ
—
0.5 cps
f = 1 MHz
VB = 0 V
500 V DC
IF = 10 mA, Duty factor = 50%
IL = Max. , VL = Max.
*Turn on/Turn off time
Input
90%
Output
10%
Toff
Ton
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
Item
Input LED current
Symbol
IF
Recommended value
Unit
5 to 10
mA
■ These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
2.-(1) On resistance vs. ambient temperature
characteristics
2.-(2) On resistance vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
–40°F to +185°F
LED current: 10 mA;
Continuous load current: 2.0 A (DC) (AQY272),
1.3 A (DC) (AQY275)
LED current: 10 mA;
Continuous load current: 0.65 A (DC) (AQY277),
0.35 A (DC) (AQY274)
3.5
5.0
0.5
AQY272
2.0
AQY275
1.5
0.4
AQY275
0.3
0.2
On resistance, Ω
2.5
On resistance, Ω
Load current, A
3.0
4.0
AQY274
3.0
2.0
AQY272
1.0
AQY277
0.5
AQY274
0
–40 –20
0
ASCTB36E 201201-T
20
40
60
8085 100
Ambient temperature, °C
Panasonic Corporation
0
AQY277
1.0
0.1
–40 –20
0
20
40
60 8085
Ambient temperature, °C
Automation Controls Business Unit
0
–40 –20
80 85
0
20
40
60
Ambient temperature, °C
industrial.panasonic.com/ac/e/
PD 1 Form A (AQY27❍)
4. Turn off time vs. ambient temperature
characteristics
5. LED operate vs. ambient temperature
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
LED current: 10 mA; Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
1.0
8
0.8
6
AQY272
4
5
LED operate current, mA
10
Turn off time, ms
Turn on time, ms
3. Turn on time vs. ambient temperature
characteristics
0.6
0.4
AQY275
AQY274
2
–40 –20
0
20
40
1
AQY274
0
–40 –20
0
20
40
60 80 85
Ambient temperature, °C
8085
60
AQY274
AQY272
AQY277
2
AQY275
AQY272
AQY277
0
3
AQY275
AQY277
0.2
4
Ambient temperature, °C
0
–40 –20
80 85
0
20
40
60
Ambient temperature, °C
6. LED turn off current vs. ambient temperature
characteristics
7. LED dropout voltage vs. ambient
temperature characteristics
8. Current vs. voltage characteristics of output
at MOS portion
Load voltage: 10 V (DC);
Continuous load current: 100 mA (DC)
Sample: all types;
LED current: 5 to 50 mA
Ambient temperature: 25°C 77°F
4
3
AQY272
AQY277
2
AQY274
Current, A
LED dropout voltage, V
LED turn off current, mA
4.0
1.5
5
1.4
1.3
50mA
30mA
20mA
10mA
5mA
1.1
–40 –20
AQY277
AQY274
0 0.5 1.0 1.5 2.0
–1.0 Voltage, V
–2.0
–3.0
0
–40 –20
8085
0
20
40
60
Ambient temperature, °C
AQY272
AQY275
–2.0 –1.5 –1.0 –0.5
1.2
1.0
0
2.0
1.0
AQY275
1
3.0
0
20
40
60
–4.0
80 85 100
Ambient temperature, °C
9.-(1) Off state leakage current vs. load voltage
characteristics
9.-(2) Off state leakage current vs. load voltage
characteristics
10. Turn on time vs. LED forward current
characteristics
Ambient temperature: 25°C 77°F
Ambient temperature: 25°C 77°F
Load voltage: 10 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
10–6
10
–9
AQY275
10–3
18
Turn on time, ms
Off state leakage current, A
Off state leakage current, A
20
10–3
10–6
AQY274
10–9
AQY272
12
10
AQY272
AQY275
8
4
0
100
AQY274
AQY277
2
10–12
50
Load voltage, V
0
14
6
AQY277
10–12
16
50
Load voltage, V
0
100
0
10
20
30
40
50
LED forward current, mA
12.-(1) Turn on time vs. load voltage
characteristics
12.-(2) Turn on time vs. load voltage
characteristics
Load voltage: 10 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
5
5
0.4
4
4
0.3
AQY275
0.2
AQY277 AQY272
AQY274
0.1
0
3
AQY272
2
10
20
30
40
50
LED forward current, mA
Panasonic Corporation
3
2
AQY274
AQY275
1
1
0
Turn on time, ms
0.5
Turn on time, ms
Turn off time, ms
11. Turn off time vs. LED forward current
characteristics
0
AQY277
0 10 20 30 40 50 60 70 80 90 100
Load voltage, V
Automation Controls Business Unit
0
0
50 100 150 200 250 300 350 400
Load voltage, V
industrial.panasonic.com/ac/e/
ASCTB36E 201201-T
PD 1 Form A (AQY27❍)
13.-(2) Turn on time vs. load current
characteristics
14.-(1) Turn off time vs. load voltage
characteristics
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
5
0.5
4
4
0.4
AQY275
3
AQY272
2
Turn off time, ms
5
Turn off time, ms
Turn on time, ms
13.-(1) Turn on time vs. load current
characteristics
3
AQY274
2
0.3
AQY272
0.2
AQY275
AQY277
1
1
0
0
0.5
1
1.5
2
2.5
Load current, A
0
3
0.1
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Load current, A
0 10 20 30 40 50 60 70 80 90 100
Load voltage, V
15.-(1) Turn off time vs. load current
characteristics
15.-(2) Turn off time vs. load current
characteristics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
0.5
0.5
0.4
0.4
0.4
0.3
0.2
Turn off time, ms
0.5
Turn off time, ms
Turn off time, ms
14.-(2) Turn off time vs. load voltage
characteristics
0.3
AQY272
0.2
0.3
0.2
AQY275
AQY277
0.1
0.1
0.1
AQY274
0
0
AQY274
0
50 100 150 200 250 300 350 400
Load voltage, V
0
0.5
1.0
1.5
2.0
2.5
Load current, A
3.0
17. Output capacitance vs. applied voltage
characteristics
Sample: All types; LED current: 10 mA;
Ambient temperature: 25°C 77°F
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
10
1800
8
7
6
5
4
3
1600
1400
1200
1000
800
400
1
200
0
25
50 75 100 125 150 175 200
Load voltage, V×load current, A
ASCTB36E 201201-T
AQY272
600
2
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Load current, A
2000
Duty factor=50%
9
Output capacitance, pF
Maximum operating frequency, time/s
16. Maximum operating frequency vs. load
voltage/current characteristics
0
AQY277
Panasonic Corporation
0
AQY275
AQY277
0
20
AQY274
40
60
80
Applied voltage, V
100
Automation Controls Business Unit
industrial.panasonic.com/ac/e/