X9015 Low Noise, Low Power, Volatile Data Sheet August 14, 2015 Single Digitally Controlled (XDCP™) Potentiometer FN8157.6 Features • 32 taps The Intersil X9015 is a 32 tap potentiometer that is volatile. The device consists of a string of 31 resistors that can be programmed to connect the RW/VW wiper output with any of the nodes between the connecting resistors. The connection point of the wiper is determined by information communicated to the device on the 3-wire port. The 3-wire port changes the tap position by a falling edge on the increment pin. The direction the wiper moves is determined by the state of the up/down pin. The wiper position at power up is Tap #15. • Three-wire up/down serial interface • VCC = 2.7V–5V • Operating ICC = 50µA max. • Standby current = 1µA max. • RTOTAL = 10k, 50k • Packages 8 Ld SOIC, 8 Ld MSOP • Pb-free plus anneal available (RoHS compliant) The X9015 can be used in a wide variety of applications that require a digitally controlled variable resistor to set analog values. Pinout SOIC/MSOP INC 1 U/D 2 RH/VH 3 VSS 4 X9015 8 VCC 7 CS 6 RL/VL 5 RW/VW Block Diagram U/D INC CS VCC (Supply Voltage) Control 30 One 28 of Thirty Two Decoder RW/VW Device Select (CS) RH/VH 31 29 RH/VH Up/Down (U/D) Increment (INC) 5-Bit Up/Down Counter RL/VL Transfer Gates Resistor Array 2 VSS (Ground) General VCC VSS Control Circuitry 1 0 RL/VL RW/VW Detailed 1 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2005, 2006, 2015. All Rights Reserved Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries. All other trademarks mentioned are the property of their respective owners. X9015 Ordering Information PART MARKING PART NUMBER X9015W Z X9015WS8ZT1 (Note) (No longer available, recommended replacement: X9015US8ZT1) VCC LIMITS (V) RTOTAL (k) TEMPERATURE RANGE (°C) PACKAGE (RoHS Compliant) PKG. DWG. # 5 ±10% 10 0 to +70 8 Ld SOIC Tape and Reel M8.15 X9015UM8Z (Note) DCF 0 to +70 8 Ld MSOP M8.118 X9015UM8IZ* (Note) DCD -40 to +85 8 Ld MSOP M8.118 X9015US8Z* (Note) X9015U Z 0 to +70 8 Ld SOIC M8.15 X9015US8IZ* (Note) X9015U Z I -40 to +85 8 Ld SOIC M8.15 10 0 to +70 8 Ld SOIC M8.15 50 0 to +70 8 Ld MSOP M8.118 -40 to +85 8 Ld MSOP M8.118 X9015W ZF X9015WS8Z-2.7* (Note) (No longer available, recommended replacement: X9015US8Z-2.7) 2.7-5.5 X9015UM8Z-2.7* (Note) DCF X9015UM8IZ-2.7* (Note) DCE X9015US8Z-2.7* (Note) X9015U ZF 0 to +70 8 Ld SOIC M8.15 X9015US8IZ-2.7* (Note) X9015U ZG -40 to +85 8 Ld SOIC M8.15 * Add “T1” suffix for tape and reel. NOTE: Intersil Pb-free plus anneal products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination finish, which are RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020. 2 FN8157.6 August 14, 2015 X9015 Pin Descriptions RH/VH and RL/VL The high (RH/VH) and low (RL/VL) terminals of the X9015 are equivalent to the fixed terminals of a mechanical potentiometer. The minimum voltage is VSS and the maximum is VCC. The terminology of RL/VL and RH/VH references the relative position of the terminal in relation to wiper movement direction selected by the U/D input, and not the voltage potential on the terminal. RW/VW RW/Vw is the wiper terminal and is equivalent to the movable terminal of a mechanical potentiometer. The position of the wiper within the array is determined by the control inputs. The wiper terminal series resistance is typically 200 at VCC=5V. At power up the wiper position is at Tap #15. (VL/RL=Tap #0). Up/Down (U/D) The U/D input controls the direction of the wiper movement and whether the tap position is incremented or decremented. Increment (INC) The INC input is negative-edge triggered. Toggling INC will move the wiper and either increment or decrement the counter in the direction indicated by the logic level on the U/D input. Chip Select (CS) The device is selected when the CS input is LOW. When CS is returned HIGH while the INC input is also HIGH the X9015 will be placed in the low power standby mode until the device is selected once again. Pin Names SYMBOL The electronic switches on the device operate in a “make before break” mode when the wiper changes tap positions. If the wiper is moved several positions, multiple taps are connected to the wiper for tIW (INC to VW change). The RTOTAL value for the device can temporarily be reduced by a significant amount if the wiper is moved several positions. When the device is powered-down, the wiper position is lost. When power is restored, the wiper is set to Tap #15. Instructions and Programming The INC, U/D and CS inputs control the movement of the wiper along the resistor array. With CS set LOW the device is selected and enabled to respond to the U/D and INC inputs. HIGH to LOW transitions on INC will increment or decrement (depending on the state of the U/D input) a five bit counter. The output of this counter is decoded to select one of thirty two wiper positions along the resistive array. The system may select the X9015, move the wiper and deselect the device. The new wiper position will be maintained until changed by the system or until a power-up/down cycle. The state of U/D may be changed while CS remains LOW. This allows the host system to enable the device and then move the wiper up and down until the proper trim is attained. Mode Selection CS High terminal RW/VW Wiper terminal Low terminal VSS Ground VCC Supply voltage U/D Up/Down control input INC Increment control input CS Chip select control input INC U/D MODE L H Wiper up L L Wiper down H X Standby mode H X X Standby mode L L X Normal mode L H Wiper Up (not recommended) L L Wiper Down (not recommended) DESCRIPTION RH/VH RL/VL The wiper, when at either fixed terminal, acts like its mechanical equivalent and does not move beyond the last position. That is, the counter does not wrap around when clocked to either extreme. Principles Of Operation There are two sections of the X9015: the input control, counter and decode section; and the resistor array. The input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the wiper output. The resistor array is comprised of 31 individual resistors connected in series. 3 FN8157.6 August 14, 2015 X9015 Absolute Maximum Ratings Operating Conditions Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C Voltage on CS, INC, U/D, VH, VL and VCC with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V V = |VH–VL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V Lead temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . +300°C IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±7.5mA Temperature Range Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C Supply Voltage (VCC) X9015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10% X9015-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. ) Potentiometer Specifications Over recommended operating conditions unless otherwise stated SYMBOL RTOTAL PARAMETER TEST CONDITIONS/NOTES End to End Resistance Variation MIN. TYP. MAX. UNIT –20 +20 % VVH VH/RH Terminal Voltage 0 VCC V VVL VL/RL Terminal Voltage 0 VCC V 10 mW Power Rating RTOTAL 1k RW Wiper Resistance IW = 1mA, VCC = 5V 200 400 RW Wiper Resistance IW = 1mA, VCC = 2.7V 400 1000 IW Wiper Current 3.75 mA -3.75 Noise Ref: 1kHz Resolution Absolute Linearity (Note 1) Vw(n)(actual)–Vw(n)(expected) Relative Linearity (Note 2) Vw(n+1)–[Vw(n)+MI] RTOTAL Temperature Coefficient -120 dBV 3 % -1 +1 MI (Note 3) -0.2 +0.2 MI (Note 3) ±300 Ratiometric Temperature Coefficient CH/CL/CW Potentiometer Capacitances ppm/°C ±20 See circuit #3 10/10/25 ppm/°C pF Power Up and Down Requirements The are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC VH, VL, VW. The VCC ramp rate spec is always in effect. NOTES: 1. Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual)–Vw(n)(expected)) = ±1 Ml Maximum. 2. Relative Linearity is a measure of the error in step size between taps = VW(n+1) – [Vw(n) + Ml] = ±0.2 Ml. 3. 1 Ml = Minimum Increment = RTOT/31. 4. Typical values are for TA = +25°C and nominal supply voltage. 5. This parameter is periodically sampled and not 100% tested. 4 FN8157.6 August 14, 2015 X9015 ) D.C. Operating Specifications Over recommended operating conditions unless otherwise specified SYMBOL PARAMETER TEST CONDITIONS MIN. TYP. (Note 4) MAX. UNITS ICC1 VCC active current (increment) CS = VIL, U/D = VIL or VIH and INC = 0.4V @ max. tCYC 50 µA ICC2 VCC active current (Store) (EEPROM Store) CS = VIH, U/D = VIL or VIH and INC = VIH @ max. tWR 400 µA ISB Standby supply current CS = VCC – 0.3V, U/D and INC = VSS or VCC – 0.3V 1 µA ILI CS, INC, U/D input leakage current VIN = VSS to VCC ±10 µA VIH CS, INC, U/D input HIGH voltage VCC x 0.7 VCC + 0.5 V VIL CS, INC, U/D input LOW voltage -0.5 VCC x 0.1 V CIN (Note 5) CS, INC, U/D input capacitance 10 pF TEST CIRCUIT #1 VCC = 5V, VIN = VSS, TA = 25°C, f = 1MHz TEST CIRCUIT #2 CIRCUIT #3 SPICE MACRO MODEL RTOTAL VH/RH VH/RH Test Point RH CW CH VS Test Point VW/RW V VL L/RL VL/RL VW/RW VW Force Current CL RL 10pF 25pF 10pF RW Symbol Table WAVEFORM INPUTS OUTPUTS Must be steady Will be steady May change from Low to High Will change from Low to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance A.C. Conditions of Test Input pulse levels 0V to 3V Input rise and fall times 10ns Input reference levels 1.5V 5 FN8157.6 August 14, 2015 X9015 A.C. Operating Specifications Over recommended operating conditions unless otherwise specified SYMBOL PARAMETER MIN. TYP. (Note 6) MAX. UNIT tCl CS to INC setup 100 ns tlD INC HIGH to U/D change 100 ns tDI U/D to INC setup 2.9 µs tlL INC LOW period 1 µs tlH INC HIGH period 1 µs tlC INC inactive to CS inactive 1 µs tCPH CS deselect time (NO STORE) 100 ns tCPH CS deselect time (STORE) 10 ms tIW INC to Vw change tCYC 1 INC cycle time tR, tF (Note 7) tPU(Note 7) 5 4 µs INC input rise and fall time Power up to wiper stable tR VCC(Note 7) VCC power-up rate tWR µs 0.2 Store cycle 5 500 µs 5 µs 50 V/ms 10 ms A.C. Timing CS tCYC tCI tIL tIH (store) tCPH tIC 90% INC 90% 10% tID tDI tF tR U/D tIW MI VW (8) NOTES: 6. Typical values are for TA = +25°C and nominal supply voltage. 7. This parameter is periodically sampled and not 100% tested. 8. MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position. 6 FN8157.6 August 14, 2015 X9015 Performance Characteristics (Typical) 0 -10 -20 -30 NOISE (dB) -40 -50 -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 FREQUENCY (kHz) 150 160 170 180 190 200 FIGURE 1. TYPICAL NOISE 10000 9800 9600 RTOTAL 9400 9200 9000 8800 8600 8400 8200 8000 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 TEMPERATURE 75 85 105 115 125 C° 95 FIGURE 2. TYPICAL RTOTAL VS. TEMPERATURE 0 -50 -100 -150 PPM -200 -250 -300 -350 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 TEMPERATURE 75 85 95 105 115 125 °C FIGURE 3. TYPICAL TOTAL RESISTANCE TEMPERATURE COEFFICIENT 7 FN8157.6 August 14, 2015 X9015 Performance Characteristics (Typical) (Continued) 800 700 600 400 300 200 100 0 0 2 4 6 8 10 12 14 18 16 TAP 20 22 24 26 28 30 32 VCC = 2.7V FIGURE 4. TYPICAL WIPER RESISTANCE 40.0% ABSOLUTE% ERROR 30.0% 20.0% 10.0% 0.0% -10.0% -20.0% -30.0% -40.0% 0 3 6 9 12 15 18 21 24 27 30 Tap FIGURE 5. TYPICAL ABSOLUTE% ERROR PER TAP POSITION 20.0% 15.0% RELATIVE% ERROR RW () 500 10.0% 5.0% 0.0% -5.0% -10.0% -15.0% -20.0% 0 3 6 9 12 15 18 21 24 27 30 TAP FIGURE 6. TYPICAL RELATIVE% ERROR PER TAP POSITION 8 FN8157.6 August 14, 2015 X9015 Applications Information Electronic digitally controlled potentiometers provide two powerful application advantages: (1) the variability and reliability of a solid-state potentiometer, and (2) the flexibility of computer-based digital controls. Basic Configurations of Electronic Potentiometers VR VR VH/RH VW/RW VL/RL I THREE-TERMINAL POTENTIOMETER; VARIABLE VOLTAGE DIVIDER TWO-TERMINAL VARIABLE RESISTOR; VARIABLE CURRENT Basic Circuits Buffered Reference Voltage Noninverting Amplifier Cascading Techniques R1 +V +V +5V +V VS +5V VW/RW VREF VOUT – VO – OP-07 + LM308A + –5V X VW/RW R2 +V –5V R1 VW/RW VOUT = VW (a) VOLTAGE REGULATOR VIN VO = (1+R2/R1)VS OFFSET VOLTAGE ADJUSTMENT VO (REG) 317 (b) R1 COMPARATOR WITH HYSTERESIS R2 VS VS R1 LT311A 100k + – 10k 10k VO (REG) = 1.25V (1+R2/R1)+Iadj R2 +12V } 10k } TL072 R2 VO VO + Iadj – R1 R2 VUL = {R1/(R1+R2)} VO(max) VLL = {R1/(R1+R2)} VO(min) -12V (FOR ADDITIONAL CIRCUITS, SEE AN115.) 9 FN8157.6 August 14, 2015 X9015 Revision History The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to the web to make sure that you have the latest revision. DATE REVISION August 14, 2015 FN8157.6 CHANGE Updated Ordering Information on page 2. Added Revision History and About Intersil sections. Updated POD M8.118 to most current revision with changes as follows: Corrected lead width dimension in side view 1 from "0.25 - 0.036" to "0.25 - 0.36" Updated to new intersil format by adding land pattern and moving dimensions from table onto drawing. Updated POD M8.15 to most current revision with changes as follows: Changed Note 1 "1982" to "1994" Changed in Typical Recommended Land Pattern the following: 2.41(0.095) to 2.20(0.087) 0.76 (0.030) to 0.60(0.023) 0.200 to 5.20(0.205) . About Intersil Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets. For the most updated datasheet, application notes, related documentation and related parts, please see the respective product information page found at www.intersil.com. You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask. Reliability reports are also available from our website at www.intersil.com/support 10 FN8157.6 August 14, 2015 X9015 Package Outline Drawing M8.15 8 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE Rev 4, 1/12 DETAIL "A" 1.27 (0.050) 0.40 (0.016) INDEX 6.20 (0.244) 5.80 (0.228) AREA 0.50 (0.20) x 45° 0.25 (0.01) 4.00 (0.157) 3.80 (0.150) 1 2 8° 0° 3 0.25 (0.010) 0.19 (0.008) SIDE VIEW “B” TOP VIEW 2.20 (0.087) SEATING PLANE 5.00 (0.197) 4.80 (0.189) 1.75 (0.069) 1.35 (0.053) 1 8 2 7 0.60 (0.023) 1.27 (0.050) 3 6 4 5 -C- 1.27 (0.050) 0.51(0.020) 0.33(0.013) SIDE VIEW “A 0.25(0.010) 0.10(0.004) 5.20(0.205) TYPICAL RECOMMENDED LAND PATTERN NOTES: 1. Dimensioning and tolerancing per ANSI Y14.5M-1994. 2. Package length does not include mold flash, protrusions or gate burrs. Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006 inch) per side. 3. Package width does not include interlead flash or protrusions. Interlead flash and protrusions shall not exceed 0.25mm (0.010 inch) per side. 4. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 5. Terminal numbers are shown for reference only. 6. The lead width as measured 0.36mm (0.014 inch) or greater above the seating plane, shall not exceed a maximum value of 0.61mm (0.024 inch). 7. Controlling dimension: MILLIMETER. Converted inch dimensions are not necessarily exact. 8. This outline conforms to JEDEC publication MS-012-AA ISSUE C. 11 FN8157.6 August 14, 2015 X9015 Package Outline Drawing M8.118 8 LEAD MINI SMALL OUTLINE PLASTIC PACKAGE Rev 4, 7/11 5 3.0±0.05 A DETAIL "X" D 8 1.10 MAX SIDE VIEW 2 0.09 - 0.20 4.9±0.15 3.0±0.05 5 0.95 REF PIN# 1 ID 1 2 B 0.65 BSC GAUGE PLANE TOP VIEW 0.55 ± 0.15 0.25 3°±3° 0.85±010 H DETAIL "X" C SEATING PLANE 0.25 - 0.36 0.08 M C A-B D 0.10 ± 0.05 0.10 C SIDE VIEW 1 (5.80) NOTES: (4.40) (3.00) 1. Dimensions are in millimeters. (0.65) (0.40) (1.40) TYPICAL RECOMMENDED LAND PATTERN 12 2. Dimensioning and tolerancing conform to JEDEC MO-187-AA and AMSEY14.5m-1994. 3. Plastic or metal protrusions of 0.15mm max per side are not included. 4. Plastic interlead protrusions of 0.15mm max per side are not included. 5. Dimensions are measured at Datum Plane "H". 6. Dimensions in ( ) are for reference only. FN8157.6 August 14, 2015