Transient Voltage Suppression Diodes Axial Leaded – 10kA > AK10 series RoHS AK10 Series Description The AK10 series of high current transient suppressors have been specially designed for use in A.C. line protection and any demanding applications (AC or DC).They offer superior clamping characteristics over standard S.A.D. technologies by virtue of the Littelfuse Foldbak™ technology, which provides a clamping voltage lower than the avalanche voltage (but above the rated working voltage). Therefore, any voltage rise due to increased current conduction is contained to a minimum, providing the best possible protection level. They can also be connected in series and/ or parallel to create very high capacity protection solutions. Agency Approvals AGENCY Features AGENCY FILE NUMBER t)BMPHFO'SFF t 3P)4DPNQMJBOU t 'PMECBL™ technology for superior clamping factor t (MBTT1BTTJWBUFE+VODUJPO t #JEJSFDUJPOBM E128662 Maximum Ratings and Thermal Characteristics Parameter Symbol 7BMVF Unit 0QFSBUJOH+VODUJPOBOE Storage Temperature Range T+T45( (-)55 to 150 °C IPP 10 kA Current Rating1 AK10 Series (TA=25OC unless otherwise noted) t 6MUSB$PNQBDU times less volume than traditional discrete solutions t 7FSZ-PX$MBNQJOH 7PMUBHF t 4IBSQ#SFBLEPXO7PMUBHF t -PX4MPQF3FTJTUBODF Note: 1. Rated IPP measured with 8 x 20μs pulse. Electrical Characteristics Part Numbers AK10 - 058C AK10 - 076C AK10 - 170C AK10 - 190C AK10 - 240C AK10 - 380C AK10 - 430C Test Max. Clamping Voltage Max. Temp Max. Max. Standoff Agency Reverse Breakdown Current VCL @ Peak Pulse Current Coefficient Capacitance Approval Reverse Voltage Voltage (VBR) @ IT IT (IPP) (Note 1) of VBR 0 Bias 10kHz Leakage (VSO) Volts (IR) @VSO μA Min Volts Max Volts (mA) VCL Volts IPP Amps (%/OC) (nF) 58 76 170 190 240 380 430 20 20 20 20 20 20 20 64 85 180 200 250 401 440 70 95 220 245 285 443 490 10 10 10 10 10 10 10 110 140 260 290 340 520 625 10,000 10,000 10,000 10,000 10,000 10,000 10,000 0.1 0.1 0.1 0.1 0.1 0.1 0.1 6.5 6.5 2.8 2.5 2.2 2.0 1.4 X X X X X X X Note: Using 8 x 20μS wave shaped defined in IEC 61000-4-5. ©2009 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.Littelfuse.com/series/AK10.html for current information. 133 Revision: June 17, 2009 AK10 Series Transient Voltage Suppression Diodes Axial Leaded – 10kA > AK10 series Soldering Parameters Pre Heat Lead–free assembly Ramp-up - Temperature Min (Ts(min)) 150°C - Temperature Max (Ts(max)) 200°C - Time (min to max) (ts) 60 – 180 secs TL Average ramp up rate (Liquidus Temp (TL) to peak 3°C/second max TS(max) to TL - Ramp-up Rate 3°C/second max Reflow tp TP Temperature (T) Reflow Condition Ts(max) Ramp-down Ts(min) ts Preheat 25˚C - Temperature (TL) (Liquidus) 217°C - Time (min to max) (ts) 60 – 150 seconds t 25˚C to Peak Time (t) Peak Temperature (TP) 260+0/-5 °C Time within 5°C of actual peak Temperature (tp) 20 – 40 seconds Flow/Wave Soldering (Solder Dipping) Ramp-down Rate 6°C/second max Peak Temperature : 265OC Time 25°C to peak Temperature (TP) 8 minutes Max. Dipping Time : 10 seconds 280°C Soldering : 1 time Do not exceed Critical Zone TL to TP tL Physical Specifications Weight Contact manufacturer Case Epoxy encapsulated Terminal Silver plated leads, solderable per MIL-STD-202 Method 208 Ratings and Characteristic Curves (T =25°C unless otherwise noted) A Peak Power Derating Percent of Rated Value 120 100 80 60 40 20 0 0 25 50 75 100 125 150 AMBIENT TEMPERATURE (°C) AK10 Series 134 Revision: June 17, 2009 ©2009 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.Littelfuse.com/series/AK10.html for current information. Transient Voltage Suppression Diodes Axial Leaded – 10kA > AK10 series Dimensions Dimensions A G L2 F D E C Millimeters A 0.950 24.15 B 0.095 2.4 C - 058C/076C 0.236 6.00 C 0.145 3.68 D 0.570 max. 14.48 max. E 0.050 1.270 F 0.500 max. 12.70 max. ($$ 0.200 5.08 ($$ 0.362 9.2 ($ 0.420 10.67 ($$ 0.650 16.50 L1 0.310 7.87 L1 - 380C/430C 0.177 4.5 -"(- UPMFSBODFJODINN L1 B Inches Part Marking System Part Numbering System Date Code AK10 XXXX Littelfuse Logo AK10-xxxx XX Series Type LF Stand Off Voltage (Please Refer to Electrical Characteristics Chart) Product Type ©2009 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.Littelfuse.com/series/AK10.html for current information. AK10 Series Note: UL mark does not appear on -058C and -076C. 135 Revision: June 17, 2009 AK10 Series