LoPAC™ Cots Family PFC Mini MI, PFC Micro MI, PFC MicroS MI Rugged AC-DC Switchers for Demanding Environments Family Features • Near unity power factor • EN61000-3-2 harmonic current compliance • Low profile package • Output power to 1,500 W • Up to 6 user specifiable outputs • Universal AC input • Power density up to 11 W/in3 • Integral cooling fans • Autosense • MIL-STD-810G for vibration and shock • MIL-STD 704 and 1399 for overvoltage and transients • -40°C operation available • Optional conformal coating PFC Mini MI 12.20" x 6.00" x 1.72" 309,9 x 152,4 x 43,6 mm Up to 1,500 W 1 to 6 Outputs Overview The MI versions of the PFC MicroS, PFC Micro and PFC Mini are new members of the LoPAC family specifically designed for demanding environments such as military and heavy industry. Available as a one, two or three slot package, respectively, each LoPAC slot can be configured with standard Vicor DC-DC converter modules enabling up to six user specifiable isolated outputs in a package only 1.72'' (43,6 mm) high with a power density of 11 W/in3. For maximum versatility and flexibility, the LoPAC can be configured with VI-26x (full brick), VI-J6x (half brick) or Maxi, Mini, Micro V375 Series full, half and quarter brick modules. These modules cover the entire range of outputs from 1 to 100 Vdc and 25 to 600 Watts. The optimum solution can be factory configured based on your exact voltage and power requirements. The LoPACs are designed to meet MIL-STD-810G for shock and vibration, MIL-STD-704 and 1399 for transients and overvoltage, and have optional -40°C operational temp rating and conformal coating. The supplies are compliant with all EN61000-6-1 for conducted and radiated immunity, as well as EN61000-3-2 for harmonic currents emissions and EN610003-3 for voltage flicker . PFC Micro MI 10.40" x 5.06" x 1.86" 264,1 x 128,5 x 47,3 mm Up to 800 W 1 to 6 Outputs PFC MicroS MI 7.95" x 5.06" x 1.86" 201,9 x 128,5 x 47,3 mm Up to 600 W 1 to 3 Outputs LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 1 of 8 03/2015 800 927.9474 PFC Mini MI, PFC Micro MI, PFC MicroS MI DC Output Selections The versatility of the LoPAC series is due, in large part, to the wide array of Vicor modules available to be configured into the different package formats. Slots can be populated with VI-200, VI-J00 or Maxi, Mini, Micro modules in full, half or quarter brick sizes. Vicor’s full VI-26x, VI-J6x and V375 standard product matrices are available to choose from. Output Voltage In addition, the full range of non-standard voltages and powers from 1 to 100 Vdc and 10 to 600 W is also available for inclusion. The table below is just a sampling of some of the most popular standard outputs that can be configured into LoPAC slots. Available Power (W) per Package Size 2 Vdc Maxi 160 VI-200 60 Mini 100 80 3.3Vdc 264 132 5Vdc 400 12Vdc VI-J00 40 30 Micro 50 99 150 66 50 75 200 150 200 100 75 100 600 200 150 300 100 75 150 15Vdc 600 200 150 300 100 75 150 24Vdc 600 200 150 300 100 75 150 28Vdc 600 200 150 300 100 75 150 48Vdc 600 200 150 300 100 75 150 LoPAC Slot Configurations The DC-DC converter modules are used to populate each LoPAC converter slot. Each slot can be configured in different ways depending on module sizes and power limitations. The following table summarizes the available slot configurations for each of the three LoPAC packages. Maximum Output Power Model Type Total # Slots @ 230 Vac @ 115 Vac Modules per Slot PFC Mini MI 3 1,500 W 800 W 1 Full or 2 Half PFC Micro MI 2 800 W 500 W 1 Full or 2 Half or 3 Quarter PFC Micro MIS 1 600 W 500 W 1 Full or 2 Half or 3 Quarter Autosense Feature* This feature is implemented in all converter slots in the LoPAC family. If remote sense connections are not needed or are inadvertently not made, no local sense connections are necessary. Simply connect the output(s) to the load and the *Applies converter(s) will automatically operate in the local sense mode. If remote sense connections are made, the unit will operate in remote sense mode. to converter slots utilizing Maxi or Mini size converters. Part Numbering PM Product Prefix PM PFC Mini MI PC PFC Micro MI PS PFC MicroS MI * X1 - X2 X3 X4 Number of VI-200 / VI-J00 module(s) Number of Output Voltages Number of Maxi / Mini / Micro module(s) Refer to Design Guide for more on the optional codes. XXXX Factory Assigned Optional Factory Assigned LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 2 of 8 03/2015 800 927.9474 - X5 - X6 Optional Factory Assigned MI Rugged Chassis CC Conformal Coat LL QF Optional Codes* Low Leakage Quiet Fan (only available on PFC Mini MI) PFC Mini MI, PFC Micro MI, PFC MicroS MI Performance Specifications specifications, consult the Design Guide for the LoPAC configuration of interest. This is available on our website (vicorpower.com). The following are typical performance specifications at room ambient temperature, nominal line voltage (115/230Vac) and 75% load on all outputs, unless specified otherwise. For detail INPUT CHARACTERISTICS Parameter AC Input Voltage Frequency DC Input Line Regulation Inrush Current @ 115 Vac @ 230 Vac Ride Through Time @ load Conducted EMI/RFI Power Factor Harmonic Current Limits Transient Burst Immunity PFC Mini MI PFC Micro MI 85 – 264 47 – 500 100 – 380 100 – 300 0.4 8.5 17 7 14 >20 1,200 FCC Class A EN55022 Class A 500 FCC Class A EN55022 Class A (consult factory) >0.98 EN61000-3-2/A14 EN61000-4-4 EN61000-4-4 Surge Immunity Load Regulation Temperature Regulation Long Term Drift Output Ripple & Noise ≤10Vout >10Vout Voltage Trim Range VI-200/VI-J00 Slots Maxi, Mini, Micro Slots Remote Sense Compensation OVP Set Point Current Limit Units Vac Hz Vdc % 2,121 4,242 750 MIL-STD 704 and 1399 PFC Mini MI Notes From low line to high line A pk A pk ms W Certain configurations meet FCC & EN Class B >75% load Class A Level 3, Performance Criteria B Installation Class 3, Performance Criteria B EN61000-4-5 Dielectric Withstand Primary to Chassis GND Primary to Secondary Secondary to Chassis GND Transients and Overvoltage OUTPUT CHARACTERISTICS Parameter Setpoint Accuracy (Standard) PFC MicroS MI Vdc Vdc Vdc PFC Micro MI PFC MicroS MI 1 % (Standard) 2% (Special) 0.05 0.2 0.005 0.02 Units % % %/°C %/khr Notes % of Vnom 10% to full load No load to full load -40°C to 65°C 100 1.0 mV % Vout 20 MHz bandwidth 20 MHz bandwidth 50 – 110 10 – 110 0.5 125 115 % Vout % Vout Vdc % Vout % Imax ±10% on 10 – 15 Vout Preload may be required Autosense (See page 2) Not available on VI-J00 modules Auto recovery ENVIRONMENTAL CHARACTERISTICS Parameter PFC Mini MI PFC Micro MI PFC MicroS MI Units Storage Temperature –40 to +85 °C Operating Temperature Full Rated Power –40 to +45 °C 50% Rated Power –40 to +65 °C Vibration MIL-STD-810E, Category 10, Minimum integrity test (PFC Mini MI only) Safety Approvals CE Marked, cTÜVus MECHANICAL CHARACTERISTICS Parameter PFC Mini MI PFC Micro MI PFC MicroS MI Units 5.5 5.2 3.1 lbs Weight 2,5 2,4 1,4 kg 12.20 x 6.00 x 1.72 10.40 x 5.06 x 1.867.95 x 5.06 x 1.86 in Overall Dimensions 309,9 x 152,4 x 43,6 264,1 x 128,5 x 47,3201,9 x 128,5 x 47,3 mm LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 3 of 8 03/2015 800 927.9474 Notes Not applicable to -40°C operating model Notes LxWxH LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 4 of 8 03/2015 800 927.9474 4 3 REF DESIGNATION LEGEND MB = MOTHER BOARD S1 = (SLOT 1) DAUGHTERBOARD MODULES E/D 1. S2 = (SLOT 2) DAUGHTERBOARD MODULES E/D 2. S3 = (SLOT 3) DAUGHTERBOARD MODULES E/D 3. A COMPLETE SET OF MATING CONNECTORS CAN BE PURCHASED FROMWESTCOR BY SPECIFYING CONNECTOR KIT P/N: 19-130047 2 WITH OPTIONAL BUSBAR. 1. INTERPRET DRAWING PER ANSI Y14.5-1994. NOTES: UNLESS OTHERWISE SPECIFIED MBJ1 INPUT CONNECTIONS MBJ1-1 EARTH GROUND MBJ1-2 L2 / NEUTRAL MBJ1-3 L1 14 AWG WIRE CLAMPING SCREWS 3 J3 INTERFACE CONNECTION MATING HDWR: (AMP P/N: OR EQUIVALENT) HOUSING: AMP P/N: 205204-4 TERMINALS: AMP P/N: 66506-9 SCREW LOCK: AMP P/N: 205980-4 CRIMP TOOL: AMP 58448-3 J3 INTERFACE PIN OUT 5 1 J3-1 E/D-1 J3-2 E/D-2 9 6 J3-3 E/D-3 J3-4 SIGNAL GROUND J3-5 VCC +5V 300mA J3-6 ACOK AC POWER OK J3-7 GSD GENERAL SHUTDOWN J3-8 SPARE J3-9 SPARE 0.487 12.36 0.920 23.37 1.72 ±0.02 43.69 ±0.51 4.00 101.60 1.00 25.40 2.210 56.13 1.600 40.64 5.268 133.81 SCALE: 1:2 BOTTOM VIEW 8.00 203.20 8.00 203.20 12.03 305.56 12.16 308.86 2 0.47 11.94 2.00 50.80 6.00 152.40 FOUR OUTPUT UNIT PICTURED (SEE PAGE 7 FOR DETAILED OUTPUT CONNECTION INFORMATION .) 0.34 ±0.02 8.64 ±0.51 CUSTOMER MOUNTING HOLES: 2X #8-32 X 0.156 or M4 X 4mm MAX LG. FROM OUTSIDE OF POWER SUPPLY CUSTOMER MOUNTING HOLES: 4X #8-32 X .156 or M4 X 4mm MAX LG. FROM OUTSIDE OF POWER SUPPLY 2.00 50.80 12.49 ±0.02 317.29 ±0.51 PFCPFC MINIMINI MI PFC Mini MI, PFC Micro MI, PFC MicroS MI Mechanical Drawing, PFC Mini MI REF SGND PGR ACOK ED6 ED5 ED4 ED3 ED2 ED1 GSD PGDV Vcc PIN CBJ3-1 CBJ3-2 CBJ3-3 CBJ3-4 CBJ3-5 CBJ3-6 CBJ3-7 CBJ3-8 CBJ3-9 CBJ3-10 CBJ3-11 CBJ3-12 CBJ3 INTERFACE CONNECTOR SIGNAL GROUND POWER GOOD/READ AC POWER OK ENABLE/DISABLE S2M3 ENABLE/DISABLE S2M2 ENABLE/DISABLE S2M1 ENABLE/DISABLE S1M3 ENABLE/DISABLE S1M2 ENABLE/DISABLE S1M1 GENERAL SHUTDOWN POWER GOOD/DATA VALID +5V@40mA DESCRIPTION LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 5 of 8 03/2015 800 927.9474 REFERENCE MB CB S(x) M(x) A COMPLETE SET OF MA TING CONNECTORS I S AVAILABLE BY SPECIFYING WESTCOR CONNECTOR KIT P/N: 19-130044 WITH OPTIONAL BUS BAR DIMENSIONS SHOWN ARE FROM BOTTOM SURFACE. MOUNTING PEMNUTS EXTEND .010 PAST BOTTOM SURFACE 2 3 4 DESIGNATIONS MOTHER BOARD CONTROL BOARD SLOT NUMBER MODULE NUMBER FLOW 1.29 32,69 3 7.500 190,50 MOUNTING HOLES; 2 PLACES USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH FROM OUTSIDE OF UNIT 10.65±0.02 270,46±0,51 10.40 264,11 7.500 190,50 AIR 10.24 260,02 0.16 4,09 MOUNTING HOLES; 2 PLACES USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH FROM OUTSIDE OF UNIT 7.500 190,50 1.29 32,69 MBJ1 (5 PIN) MBJ1 A/C INPUT 2 MATING CONNECTOR: L1 HOUSING: MOLEX (39-01-4051) N/C TERMINAL: MOLEX (39-00-0090) L2/N CRIMP TOOL: MOLEX (11-01-0199) N/C GND PIN-1 CBJ3 (12 PIN) 1.29 32,69 1 S2 SIX OUTPUT UNIT PICTURED (SEE PAGE 7 FOR DETAILED OUTPUT CONNECTION INFORMATION . ) MOUNTING HOLES; 4 PLACES USE 8-32 X 0.12 or M4 X 3MM MAX LENGTH FROM OUTSIDE OF UNIT 0.71 18,03 3.500 88,90 3 1 S1 5.06 128,52 4 1.86 47,29 0.25±0.02 6,35±0,51 1.22 31,04 4 4 1.22 31,04 Mechanical Drawing, PFC Micro MI 1 NOTES: UNLESS OTHERWISE SPECIFIED 2 MATING CONNECTOR: HOUSING: MOLEX (50-57-9412) SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097) CRIMP TOOL: MOLEX (11-01-0209) 1 PFC MICRO PFC MICRO MI PFC Mini MI, PFC Micro MI, PFC MicroS MI SGND PGR ACOK N/C N/C N/C ED3 ED2 ED1 GSD PGDV Vcc LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 6 of 8 03/2015 800 927.9474 REFERENCE MB CB S(x) M(x) A COMPLETE SET OF MATING CONNECTORS IS AVAILABLE BY SPECIFYING WESTCOR CONNECTOR KIT P/N: 19-130044 DIMENSIONS SHOWN ARE FROM BOTTOM SURFACE. MOUNTING PEMNUTS EXTEND .010 PAST BOTTOM SURFACE. 2 3 DESIGNATIONS MOTHER BOARD CONTROL BOARD SLOT NUMBER MODULE NUMBER MBJ1 A/C INPUT 2 1.29 32,69 FLOW AIR 0.16 4,09 1.29 32,69 1.29 32,82 MATING CONNECTOR: L2/N HOUSING: MOLEX (39-01-4051) TERMINAL: MOLEX (39-00-0090) GND CRIMP TOOL: MOLEX (11-01-0199) L1 1 N/C PIN 1 MBJ1 (5 PIN) CBJ3 (12 PIN) N/C SIGNAL GROUND POWER GOOD/READ AC POWER OK N/C N/C N/C ENABLE/DISABLE S1M3 ENABLE/DISABLE S1M2 ENABLE/DISABLE S1M1 GENERAL SHUTDOWN POWER GOOD/DATA VALID +5V@40mA MATING CONNECTOR: HOUSING: MOLEX (50-57-9412) TERMINAL: MOLEX (16-02-0097) CRIMP TOOL: MOLEX (11-01-0209) CBJ3-1 CBJ3-2 CBJ3-3 CBJ3-4 CBJ3-5 CBJ3-6 CBJ3-7 CBJ3-8 CBJ3-9 CBJ3-10 CBJ3-11 CBJ3-12 CBJ3 E/D INTERFACE CONNECTOR PIN REF DESCRIPTION NOTES: UNLESS OTHERWISE SPECIFIED 2 1 PFC PFCMICROS MICROSMI 5.100 129,54 MOUNTING HOLES; 2 PLACES USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH FROM OUTSIDE OF UNIT 5.100 129,54 7.95 201,88 MOUNTING HOLES; 2 PLACES USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH FROM OUTSIDE OF UNIT 5.100 129,54 1.22 31,04 3 MOUNTING HOLES 4 PLACES USE 8-32 X 0.12 or M4 X 3MM LENGTH FROM OUTSIDE OF UNIT 0.71 18,03 1 S1 3 1.86 47,29 3 5.06 128,52 3.500 88,90 1.22 31,04 TRIPLE OUTPUT UNIT PICTURED (SEE PAGE 7 FOR DETAILED OUTPUT CONNECTION INFORMATION). PFC Mini MI, PFC Micro MI, PFC MicroS MI Mechanical Drawing, PFC Micro MIS PFC Mini MI, PFC Micro MI, PFC MicroS MI Output Connections for the PFC Mini MI, PFC Micro MI and PFC MicroS MI A. OUTPUT STUDS - SINGLE OUTPUT (when populated with Full Brick modules) PFCPFC Micro and MI PFC MicroS PFC Mini, Mini MI, Micro and PFC MicroS MI –V OUT 10-32 OUTPUT STUDS SxJ2 REMOTE SENSE/TRIM PIN CONNECTOR 3 2 1 +V OUT – REMOTE SENSE + REMOTE SENSE TRIM MATING CONNECTOR: HOUSING: MOLEX (50-57-9403) TERMINAL FEMALE CRIMP 22-24 AWG: MOLEX (16-02-0103) USE CRIMP TOOL: MOLEX (11-01-0208) B. MOLEX CONNECTOR - SINGLE OR DUAL OUTPUT (when populated with Half Brick modules) PFC Housing PFC Micro MICRO PFC MI1818Pin PinHousing Housing PFC MINI Mini 18 MI Pin 18 Pin Housing SxJ1 (18 PIN OUTPUT, REMOTE SENSE AND TRIM PIN CONNECTOR) SxJ1 (18 PIN OUTPUT, REMOTE SENSE AND TRIM PIN CONNECTOR) 9 18 8 17 7 16 6 15 5 14 4 13 3 12 2 11 1 10 PIN 1 2 3 4 5 6 7 8 9 DESCRIPTION + V OUT M2 – V OUT M2 – V OUT M2 + SENSE M2 – SENSE M2 TRIM M1 + V OUT M1 + V OUT M1 – V OUT M1 PIN 10 11 12 13 14 15 16 17 18 DESCRIPTION + V OUT M2 + V OUT M2 – V OUT M2 + SENSE M1 TRIM M2 – SENSE M1 + V OUT M1 – V OUT M1 – V OUT M1 9 18 8 17 7 16 6 15 5 14 4 13 3 12 2 11 1 10 PIN 1 2 3 4 5 6 7 8 9 DESCRIPTION + V OUT M1 – V OUT M1 – V OUT M1 + SENSE M1 – SENSE M1 TRIM M2 + V OUT M2 + V OUT M2 – V OUT M2 PIN 10 11 12 13 14 15 16 17 18 DESCRIPTION + V OUT M1 + V OUT M1 – V OUT M1 + SENSE M2 TRIM M1 – SENSE M2 + V OUT M2 – V OUT M2 – V OUT M2 MATING CONNECTOR: 18 PIN HOUSING: MOLEX (39-01-2180) TERMINAL FEMALE CRIMP 18-24 AWG: MOLEX 39-00-0039) USE CRIMP TOOL: MOLEX (11-01-0197) *PFC MicroS dual output slot configuration uses the type A stud connection for both outputs. 3-pin connector designators are S1J1 and S1J2. C. MOLEX CONNECTOR - SINGLE, DUAL OR TRIPLE OUTPUT (when populated with Quarter Brick modules) PFC Micro PFCPFC MicroS Micro and MI and MicroS MI SxJ1 (16 PIN OUTPUT, REMOTE SENSE AND TRIM PIN CONNECTOR) 8 16 7 15 6 14 5 13 4 12 3 11 2 10 1 9 PIN 1 2 3 4 5 6 7 8 DESCRIPTION +V OUT M3 –V OUT M3 TRIM M3 +V OUT M2 –V OUT M2 TRIM M2 +V OUT M1 –V OUT M1 PIN 9 10 11 12 13 14 15 16 DESCRIPTION +V OUT M3 –V OUT M3 N/C +V OUT M2 –V OUT M2 TRIM M1 +V OUT M1 –V OUT M1 MATING CONNECTOR: 16 PIN HOUSING: MOLEX (39-01-2160) TERMINAL FEMALE CRIMP 18-24 AWG: MOLEX (39-00-0039) USE CRIMP TOOL: MOLEX (11-01-0197) The following accessories are available for the LoPAC units: Connector Kits Current Share Boards A complete set of mating hardware for all combinations of input & output connections PFC Micro MI & PFC MicroS MI PFC Mini MI Used for current sharing between identical LoPAC Models for increased output power or redundancy 19-130044 19-130047 LoPACs with VI-200/VI-J00 Modules LoPACs with Maxi, Mini, Micro Modules LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 7 of 8 03/2015 800 927.9474 CSB01 CSB02 PFC Mini MI, PFC Micro MI, PFC MicroS MI Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] LoPAC™ Cots Family Rev 1.1 vicorpower.com Page 8 of 8 03/2015 800 927.9474