PDF cURus UL 1604, CSA C22.2 No. 213-M1987 Class I, Div. 2

File E181848
Project 95NK30863
July 19, 1996
REPORT
on
COMPONENT - POWER SUPPLIES FOR USE IN
HAZARDOUS LOCATIONS
Vicor Corporation
Andover, MA
Copyright
©
1996 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above
named company to reproduce this Report provided it is
reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above
named company to reproduce that portion of this Report
consisting of this Cover Page through Page 2.
LW/KAH:iad
DMS
*File E181848
Vol. 1
Sec. 2
and Report
Page 1
Issued:
7-19-96
Revised:
11-4-96
D E S C R I P T I O N
PRODUCT COVERED:
USL, CNL
Component - Power supplies, ComPac Series, Model
No. VI, followed by L, M, N, P, Q or R, followed
by C, followed by 1, W, 3, N or 6, followed by up
to three numbers or letters which may be Z, Y,
O, X, W, V, T, R, M, 1, P, 2, N, 3, L, J, K, 4,
H, F, D or B, followed by C, I, M or E, followed
by up to three numbers or letters which may be M,
P, Q, S, U, V, W, X, Y or Z, followed by two
optional digits 00 through 99.
Class I, Groups A, B, C and D, Division 2 only.
NOMENCLATURE BREAKDOWN:
Refer to ILL. 2.
ELECTRICAL RATINGS:
Refer to ILL. 2.
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
This product was investigated under the Standards for Electrical
Equipment For Use in Class I and Class II, Division 2 and Class III Hazardous
(Classified) Locations, UL 1604, and Information Technology Equipment,
UL 1950, Second Edition (No. D3 Deviations) and the Standard for Telephone
Equipment, UL 1459, Second Edition.
CNL indicates investigation to Canadian Standard C22.2 No. 2130M1987.
USL indicates investigation to United States Standards listed below.
Use - For use only in (or with) complete equipment where the
acceptability of the combination is determined by Underwriters Laboratories
Inc.
This power supply consists on various R/C power supplies mounted on a
printed wiring board with additional front end circuitry. Primary to
secondary isolation is provided by these various R/C power supplies.
DD/SC:bak
NKDLS
*File E181848
Vol. 1
Sec. 2
and Report
Page 2
Issued:
7-19-96
Revised:
11-4-96
Conditions of Acceptability 1. The supplies should be installed within an enclosure so that the
exposed current-carrying parts (wiring terminals) are suitably enclosed.
2. The Temperature Test should be conducted in the end application to
determine a T Code.
3. The need for the following instructions shall be determined in the
end application.
A.
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND
D, AND CLASS II, DIVISION 2, GROUPS F AND G HAZARDOUS
LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
B.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, CLASS II, DIVISION 2.
C.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR *THE AREA IS
KNOWN TO BE NONHAZARDOUS.
D.
LW/KAH:iad
DMS
WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS,
TURN OFF POWER BEFORE REPLACING OR WIRING MODULES.
File E181848
Company:
Vol. 1
Sec. 2
Ill. 2
Vicor Corporation, 25 Frontage Road Andover, MA 01810 USA
VI - a C b c c c - d e e e - f f f
ComPAC Family Tree
VI
Product Type
VI = VI (Vicor), VI = VE (Vicor RoHs), VI = IP (VJCL), VI = IE (VJCL RoHs), MI = Military
a
Module Configurations
L = 1UP Single (1module, 1 output)
M = 2UP Single (2 modules, 1 output)
N = 3UP Single (3 modules, 1 output)
P = 2UP Dual (2 modules, 2 outputs)
Q = 3UP Dual (3 modules, 2 outputs)
R = 3UP Triple (3 modules, 3 outputs)
b
Input Voltage (Vdc)
Nominal
Range
1 = 24
21-32 @
W = 24
18-36 @
3 = 48
42-60 @
N = 48
36-76 @
6 = 300
200-400 @
d
Product Grade
C = Commercial -20C to 85C
I = Industrial
-40C to 85C
M = Military
-55C to 85C
E = Economy
0C to 85C
eee
Output Power
M = 600W
P = 450W
Q = 400W
S = 300W
U = 200W
V = 150W
W = 100W
X = 75W
Y = 50W
fff
Factory assigned code
Non-safety related, any alphanumeric combination or blanks, 0-3 characters
ccc
Output voltage (Vdc) Nominal
Z = 2.0
2 = 15.0
Y = 3.3
N = 18.5
O = 5.0
3 = 24.0
X = 5.2
L = 28.0
W = 5.5
J = 36.0
V = 5.8
K = 40.0
T = 6.5
4 = 48.0
R = 7.5
H = 52.0
M = 10.0
F = 72.0
1 = 12.0
D = 85.0
P =13.8
B = 95.0
Example
VI-PC601-CUX-23
P = 2Up (2 modules, 2 outputs), 6 = 300 V Input, 0 = 5V output, 1 = 12Vdc output
C= Commercial product Grade, U = 200W output, X = 75W output, 23 = Customer Code
LW/KAH:iad
DMS
Max (A)
26.7
31.2
18.0
15.6
3.9