Catalog

PMA-12
Photonic multichannel analyzer
Scientific applications
UV to visible spectroscopy
Fluorescence spectroscopy
Raman scattering
Chemiluminescence analysis
Liquid chromatography
Gas chromatography
ICP emission analysis
Discharge spectrum analysis
Combustion analysis
Micro spectroscopy
Industrial applications
Water quality testing
Evaluation of light emitting
devices and light sources
Chromaticity measurements
Impurities testing
Film thickness measurements
UV radiation measurements
Plasma monitoring
Fruit testing
Combustion monitoring
Color filter evaluation
P
hotonic multichannel analyzer
A compact unit containing a spectrometer, photo-detector and power supply.
Use of an optical fiber input makes spectral measurements easy.
It becomes easier to use of PMA-12 because of USB2.0 interface.
The PMA-12 is compact spectral measurement apparatus that combines a spectrometer and optical detector into one unit.
An optical fiber is used. Because of the high sensitivity, spectra can be obtained easily just by bringing the optical fiber close to the sample in
normal applications, without a special light collection system. Since the spectrometer and photo-detector are fixed, the PMA-12 is stable and can
be used with confidence for long periods of time. The wavelength axis and spectral response characteristics are already calibrated, so spectral
measurements can be carried out easily and accurately.
C10544-01
C10544-02
High sensitivity superior
cost-performance model
C10027-01
C10028-02
C10029-01
Near infrared model
These are models using InGaAs linear image sensors and capable of
measurements of reflection and absorption spectra in the near infrared
with a large dynamic range. The wavelength range for measurements is
900 nm to 1650 nm for the C10028-01 and 1600 nm to 2350 nm for the
C10028-02.
High time resolution model
Coupling an image intensifier with a thermoelectrically cooled, back-thinned
CCD linear image sensor, it is possible to have both high-speed gate
measurements at a maximum of 10 ns and ultra-high sensitivity. This model
is capable of high temporal resolution measurements in the nanosecond
range and measurements of faint light.
Features
PMA-12 Standard Configuration
Spectrometer, photo-detector and power supply
in a compact unit
Light source
Real-time measurements (Simultaneous
measurement of multiple wavelengths possible)
Fiber input optics
Microscope
USB 2.0
Bundled fiber
C10544-01, -02
(High sensitivity superior cost-performance model)
C10027-01, -02
(Ultra-high sensitivity model)
C-mount adapter
for positioning
A9607
(Option)
Wide range of variations
CCD and BT- CCD linear image sensor
C10028-01, -02
(Near infrared model)
C10029-01
(High time resolution model)
InGaAs linear image sensor
C10027-01,-02
50
40
30
20
10
0
200
600
800
Wavelength (nm)
2
C10028-01
0.8
C10028-02
0.6
0.4
0.2
C10544-01, -02
400
1.0
Cathode radiant Sensitivity (mA/W)
1.2
Sensitivity (A/W)
Quantum efficiency (%)
90
1000
1200
0.0
800
1000
1200
1400
1600
1800
2000
Wavelength (nm)
Data analyzer Laptop type
C10471-01
(Option)
*Data analyzer Desktop type
C10471-02 (Option) is available.
I.I. + BT- CCD linear image sensor
100
70
PMA software
C10027
SIGNAL INPUT
Spectral response and wavelength
axischaracteristics calibrated
80
Main unit
PHOTONIC MULTI-CHANNEL ANALYZER
Easy measurements with optical fiber
60
Ultra-high
sensitivity model
This model uses a thermoelectrically cooled, back-thinned CCD linear
image sensor that with higher sensitivity and lower noise. The C10027-01 is
an ultra-high sensitivity model that combines this sensor with a small
Czerny-Turner spectrograph capable of measurements over a wide range
from the ultraviolet to the near infrared with high wavelength resolution. The
wavelength range for measurements is 200 nm to 950 nm for the C10027-01
and 350 nm to 1100 nm for the C10027-02.
C10544-01, -02, which have the thermoelectric cooling type CCD linear
image sensor that is used for astronomical observation, have realized
both high performance and low price by rational design.the wavelength
range for measurement is 300 nm to 800 nm for the C10544-01 and 340
nm to 830 nm for the C10544-02.
C10028-01
C10027-02
2200
2400
2600
103
102
C10029-01
101
100
10-1
100 200 300 400 500 600 700 800 900 1000
Wavelength (nm)
SOFTWARE
Measurement modes
Standard measurements
This is the most basic measurement mode.
Applications: emission spectra for light sources, fluorescence, plasma and the like.
Reflective measurements
This is the measurement mode for finding spectral reflectance.
Applications: reflectance measurements for optical filters, coatings and the like.
Transmittance and absorption measurements
This is the measurement mode for finding spectral transmittance and absorption.
Applications: measurements of transmittance and absorption in optical filters, films,
solutions and the like.
Chromaticity measurements (light-source color)
This is the measurement mode for finding the light-source color for luminous bodies.
Applications: color evaluation in light sources for illumination, LEDs and the like.
Chromaticity measurements (object color)
This is the mode for finding the color of objects that are either reflective or transmit light.
Applications: color evaluation of paint, fabric, printed matter and the like.
Display modes
Spectrum display
Display of changes over time
s
3-D display
Reflectivity display
Transmittance display
Absorbance display (OD)
Color coordinate display
Spatial color coordinate display
3
APPLICATION
EXAMPLES
Light source measurements
PHOTONIC MULTI-CHANNEL ANALYZER
Measurement of emission spectra in light
sources such as lamps and LEDs
Germicidal lamp emission spectrum
PMA-12
SIGNAL INPUT
Analysis of light source color by emission spectrum
(chromaticity, color temperature, color rendering properties, etc., possible)
Metal halide lamp chromaticity evaluation
Light source
PMA-12
<Configuration>
Metal halide lamp emission spectrum
• Standard PMA-12 configuration
(C10544, C10027, etc.)
Option
• Data analyzer C10471-01,-02
White LED chromaticity evaluations
<Applications>
• Evaluation of color temperature and
color rendering properties in light
sources for illumination
White LED emission spectrum
• LED chromaticity evaluations
• Special applications of light source
spectral evaluations
Emission spectrum measurements
Emission spectrum measurements for plasma,
electric discharge, ablation and the like
Electric discharge emission spectrum
C10027
PHOTONIC MULTICHANNEL ANALYZER
Emission spectrum during oxide film etching
C-mount adapter
for positioning
A9607
+
OBJECTIVE LENS
A4869
SIGNAL INPUT
PMA-12
Emission spectrum during nitride film etching
Chamber
<Configuration>
<Applications>
• Standard PMA-12 configuration (C10027, C10029, etc.)
• Plasma component
analysis
Options
• Data analyzer C10471-01,-02
• Analysis of various
emission phenomena
• C-mount adapter for positioning A9607
Temporal changes in plasma emission spectrum
• OBJECTIVE LENS A4869
• Digital delay generator C13430-01
Example of temporal resolution (gate operation) measurements
PMA-12 (C10029-01)
C10029
PHOTONIC MULTICHANNEL ANALYZER
SIGNAL INPUT
TRIG
BUSY
RATE
INT
To
TRIG
MENU
DELAY
OUTPUT
GPIB
STORE
RECALL
A
B
Digital delay
generator
C13430-01
4
us
ms
S
TRIGGER
A
MUM
REM
B
A
POWER
ps
ns
+/-
BSP
7
8
•
4
5
6
EXP
0
1
2
3
EXC
B
C
9
D
C-mount adapter
for positioning
A9607
+
OBJECTIVE LENS
A4869
C
LCD
ON OFF
LCD
D
Trigger
C
D
Chamber
Time
Gate ON
Gate OFF
Wavelength
APPLICATION
EXAMPLES
Reflective spectrum measurements
PMA-12
SIGNAL INPUT
AR coating reflection spectrum
<Configuration>
• Standard PMA-12 configuration
(C10544, C10027, etc.)
PMA-12
PHOTONIC MULTI-CHANNEL ANALYZER
Measurement of spectral reflectance in optical filters,
anti-reflective films (AR coatings) and the like
Options
Sample
Xe light source
High stability 150 W
L6759
• Data analyzer C10471-01,-02
• Xe light source High stability 150 W L6759
• Optical split fiber UV to VIS 2 m A10193-01
<Applications>
• Inspection of coatings
• Monitoring thin film growth
Without AR coating
With AR coating
Object color measurements
PHOTONIC MULTI-CHANNEL ANALYZER
Paper object color (chromaticity coordinates)
<Configuration>
• Standard PMA-12 configuration
(C10544, C10027, etc.)
PMA-12
SIGNAL INPUT
Object color evaluation of paint,fabric,
printed matter and the like
PMA-12
Options
Sample
• Data analyzer C10471-01,-02
• Halogen lamp L6758-11
Orange
<Applications>
• Paint inspections
• Color evaluations in printed matter,
fabric, plastics, etc.
Halogen lamp
L6758-11
Absorption spectrum measurements
PMA-12
Xe light source
High stability
150 W
L6759
PHOTONIC MULTI-CHANNEL ANALYZER
PMA-12
SIGNAL INPUT
Blue
Spectral transmittance and absorption measurements
in optical filters, films, solutions and the like
Component analysis of plastics using
transmission spectra (polycarbonate and PET resins)
Didymium film absorption spectrum
Sample Holder for
transmission and fluorescence
measurement A6751
<Configuration>
• Standard PMA-12 configuration
(C10544, C10027, etc.)
Polycarbonate
PET resin
MMA and PMMA transmission spectra
Options
PMMA
Changes in transmissivity in the
polymerization from MMA to
PMMA (wavelength: 1615 nm)
After
polymerization
• Data analyzer C10471-01,-02
• Xe light source High stability 150 W L6759
• Sample Holder for transmission and fluorescence
measurement A6751
<Applications>
• Absorption spectrum evaluations for solutions
and films
• Component analysis for samples
• Monitoring chemical changes
Before polymerization
MMA
Microscopic spectral measurements
PHOTONIC MULTICHANNEL ANALYZER
SIGNAL INPUT
PMA-12
C10027
C-mount adapter
for positioning
A9607
During polymerization
Spectral distribution measurements
under a microscope
<Configuration>
• Standard PMA-12 configuration (C10027, C10029, etc.)
Options
• Data analyzer C10471-01,-02
• C-mount adapter for positioning A9607
<Applications>
• Measurement of bioluminescence
• Measurements on semiconductor wafer, LCD and other microstructures
5
APPLICATION
EXAMPLES
Emission spectrum measurements
PHOTONIC MULTI-CHANNEL ANALYZER
Fluorescence indicator (Fluorescein)
emission spectrum
PMA-12
PMA-12
SIGNAL INPUT
Excitation
light
source
For fluorescent samples such as
fluorescent lamps and EL devices
Sample Holder for
transmission and
fluorescence
measurement A6751
Fluorescent lamp fluorescent body emission spectrum
<Configuration>
• Standard PMA-12 configuration (C10544, C10027, etc.)
<Applications>
• Fluorescence spectroscopy
• Monitoring chemical light emissions
Options
• Data analyzer C10471-01,-02
• Excitation light source: laser, xenon lamp, etc.
• Sample Holder for transmission and fluorescence
measurement A6751
Film thickness measurements
PMA-12
C10027
PHOTONIC MULTI-CHANNEL ANALYZER
SIGNAL INPUT
Film thickness measurements using
spectral reflectance or transmittance
Optical split fiber VIS to NIR 2 m
A10193-02
Data analyzer
C10471-01
Chemiluminescence emission spectrum
ITO film interference spectrum
Sample
Film thickness
measurement
software
U10339-01
Halogen lamp
L6758-11
Sample stage Sleeve type
A10192-01
<Configuration>
• Standard PMA-12 configuration (C10027)
Options
<Applications>
• Monitoring thin film growth
• Film thickness management
• Resist film thickness measurements
• Data analyzer C10471-01,-02
• Halogen lamp L6758-11
• Optical split fiber VIS to NIR 2 m A10193-02
• Film thickness measurement software U10339-01
Quantum yield measurement system
Power supply
(for Xenon light source)
PMA-12
PHOTONIC MULTI-CHANNEL ANALYZER
Optical Gauge series
C10178,C10323
We can offer specialized machine for film thickness measurement.
Please refer the detail in specific brochure.
Measurement of quantum yield, external quantum effciency,
brightness light distribution characteristics
[Screen showing emission spectrum]
PMA-12
SIGNAL INPUT
Fiber probe
150 W CW
Xenon light source
Spectrometer
Excitation
light guide
Integration
sphere
Data analyzer
Nitrogen gas
(flow)
PL measurement
software
PL measurement
sample holder
<Applications>
• Research of fluorescence materials in physics or chemistry
• Quantum yield measurement of emission materials
• Internal quantum yield measurement of fluorescence materials
6
Absolute PL quantum yield spectrometer C9920-02,-02G,-03,-03G
External quantum efficiency measurement system C9920-12
Light distribution measurement system C9920-11
We can offer specialized machine for OLED measurement.
Please refer the detail in specific brochure.
OPTIONS
Options
Sample Holder for
transmission and
fluorescence
measurement A6751
Reflection
measurement optics
A9665
Variable angle reflection
measure optics
A10687
Digital delay generator
C13430-01
Optical split fiber
A10193-01,-02
This is a dedicated holder
with an integrated condensing lens for the use with
vials.
These are optics making it
possible to illuminate the
sample at 45˚ from the
light source and measure
the reflected light.
These are optics making it
possible to change the
angle of input and output
ports at maximum 60˚ and
measure the reflected light
and fluorescence.
This outputs the gate
pulse necessary for an
external trigger and gate
operation.
It is very useful for reflectance measurement or film
thickness measurement.
We have two kind of fiber.
One is A10193-01 for
visible range and the
other is A10193-02 for
from visible range to near
infrared range.
C-mount fiber adapter
A6399
C-mount adapter for
positioning
A9607
Data analyzer
C10471-01,-02
OBJECTIVE LENS
A4869
Integrating sphere
A5640
This is an adapter for
securing the fiber input
optics to the C-mount of
a microscope or the like.
The A6399 is usable in
UV to NIR wavelength.
In addition to the function
of the C-mount fiber
adapter, the measurement
position can be checked.
The A9607 is usable in
UV to NIR wavelength.
A data analyzer is provided.
There are the C10471-01
notebook model and the
C10471-02 desktop model .
Condensing lens for UV.
f=50 mm, F3.5
This is the integrating
sphere
for
getting
complete diffuse light. You
can get even intensity light
without spread of light
source or influence of
directional characteristics.
(A6399 or A9607 required)
(A6399 required)
Software library
U10472-01
This is the software library
which controls the PMA-12
series.
Halogen lamp
L6758-11
Xe light source
High stability 150 W
L6759
Attenuation fiber
adapter
A10474-01
This is a halogen light
source with output wavelengths from 400 nm to
1600 nm for excitation and
absorption measurements.
This is a high stability
xenon light source with
output wavelengths from
250 nm to 1600 nm for
excitation and absorption
measurements.
This adaptor is used
when the light power is
too strong. It can reduce
the input light power by
using a pin-hole.
(fading rate approx 1 /20
to 1 /500)
Light guide connector
* A10194-01
is needed to
Relative intensity
400 500
This is the software library
which controls the PMA-12
series and calculates the
chromaticity.
Relative intensity
connect with 2 split fiber.
Color measurement
library U10473-01
1000
Wavelength (nm)
1500
250 400
600
800
1000
1200 1400 1600
Wavelength (nm)
7
SPECIFICATIONS
Model
C10544-01
Photo-detector
C10544-02
Wavelength (nm)
300 to 800
340 to 830
< 3 nm
Wavelength resolution (FWHM)*1
C10027-01
C10028-01
C10027-02
BT- CCD linear
image sensor
CCD linear
image sensor
C10028-02
C10029-01
InGaAs linear
image sensor
200 to 950
350 to 1100
< 2 nm
< 2.5 nm
900 to 1650
I.I. + BT- CCD
linear image sensor
1600 to 2350
200 to 860
19 ms to 64 s
< 9 nm
< 3 nm
19 ms to 64 s
19 ms to 64 s
5 ms to 64 s
(1 ms to 64 s)
(1 ms to 64 s)
5 ms to 50 ms
Gate time*2
–
–
–
–
10 ns
Gate repetition
–
–
–
–
200 kHz
Exposure time
(Exposure Start Mode)
(1 ms to 64 s)
Number of photosensitivedevice channels
Pixel size
1024 ch
1024 ch
256 ch
900 ch
24 μm × 2.928 mm
50 μm × 250 μm
24 μm × 2.928 mm*3
0 ˚C
-15 ˚C
-10 ˚C
-15 ˚C*3
18
16
12 500
16*3
400
(0 ˚C : 20 ms)
75
(-15 ˚C : 20 ms)
Read-out noise
(electrons)
(electrons/scan)
(1 ms to 64 s)
24 μm × 3.07 mm
Device cooling temperature
Dark current
(1 ms to 64 s)
AD resolution
20 000
(-10 ˚C : 20 ms)
2.5 × 107
(-10 ˚C : 20 ms)
75*3
(-15 ˚C : 20 ms)
16 bit
Spectrograph
Czerny-Turner type
Concave spherical grating type
Spectrograph F number
4
3
Fiber receiving area
Φ1 mm
Fiber type
Bundled fiber Φ12 mm SUS tube
1.5 m*4
Fiber length
TTL level / High impeadance
External trigger input
USB 2.0
Interface
AC 100 V to AC 240 V, 50 Hz / 60 Hz (Power supply voltage variation ±10 %)
Power supply
*1 Confirmed with mercury and argon atomic beams.
*2 The gate time is controlled by the external gate pulse width.
*3 I.I. characteristics are not included.
*4 A 1.5 m cable is included as standard.
Dimensional outlines (Unit : mm)
C10544-01, -02
C1
C10025
PHOTONIC MULTI-CHANNEL ANALYZER
flexible tube (Φ7)
+0
Φ10 -0.1
Fiber input optics for C10544, C10027, C10028, C10029
+0
Φ12 -0.1
Main unit
(approx.100 g)
3
0.2
99
SIGNAL INPUT
Bundle diameter Φ1.0
15 strands
333
9.7
202
C10027-01, -02
50
1500
Basic software for PMA-12 U6039-01
C10027
PHOTONIC MULTI-CHANNEL ANALYZER
80
99
SIGNAL INPUT
383
9.7
262
C10028-01, -02
C10028
PHOTONIC MULTI-CHANNEL ANALYZER
124
SIGNAL INPUT
433
9.7
262
C10029-01
C10029
PHOTONIC MULTI-CHANNEL ANALYZER
430
9.7
99
SIGNAL INPUT
383
Measurement functions ………………………… Monitoring measurement
Data measurement
Temporal resolution measurement functions … Temporal fluctuation of spectra
Temporal fluctuation in reflectivity and transmissivity
Data acquisition condition settings …………… Exposure time settings
Memory integration count assignment
Calibration/correction …………………………… Wavelength axis calibration
Sensitivity inconsistency calibration
Dark current correction
…………………………………
Display functions
Spectrum display
Display temporal waveform fluctuations
Wavelength axis display …………..……………. Wavelength, Wave number, Raman shift, energy (eV)
Brightness axis display …………………………. Linear, Logarithm
Cursor analysis functions …………..…………... Wavelength (wave number, etc.) vs. Intensity
Peak detection
FWHM measurement
Integrated intensity
Other analytical functions …………….………… Smoothing
Differential waveform
Color calculation (XYZ, xy, uv, Lab)
Product and software package names noted in this documentation are trademarks or registered trademarks of their respective manufacturers.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult your local sales representative.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications and external appearance are subject to change without notice.
© 2016 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Systems Division
812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-435-1574, E-mail: [email protected]
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, NJ 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-935-81-733, Fax: (39)02-935-81-741 E-mail: [email protected]
China: Hamamatsu Photonics (China) Co., Ltd.: 1201 Tower B, Jiaming Center, 27 Dongsanhuan Beilu, Chaoyang District, 100020 Beijing, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
Taiwan: Hamamatsu Photonics Taiwan Co., Ltd.: 8F-3, No.158, Section2, Gongdao 5th Road, East District, Hsinchu, 300, Taiwan R.O.C. Telephone: (886)03-659-0080, Fax: (886)07-811-7238 E-mail: [email protected]
Cat. No. SDSS0008E13
MAY/2016 HPK
Created in Japan