LITTELFUSE SL1122A450

Gas Discharge Tubes
High Performance Alpha Range
RoHS
Greentube™ SL1122A Series Hybrid Gas Plasma Arresters
®
The SL1122 series Hybrid features a high performance Alpha Gas
Plasma Tube in conjunction with a high speed Silicon Avalanche
Diode ( SAD ). These devices are matched so that High speed
pulses are initially clamped by the SAD, then as the current rises,
the transient energy is switched through the Gas Tube. The
Hybrid offers high levels of performance on fast rising transients
in the domain of 100V/µS to 10 KV/µS, so eliminates the dv/dt
switching delay normally exhibited by standard GDT’s. These
devices are extremely robust and are able to divert a 10,000Amp
pulse without destruction, so are ideal for central office ( telephone exchange ) protection.
FEATURES
• RoHs Compliant
• Excellent response to fast rising transients.
• Flat response up to 10KV/µS.
• 10KA surge capability tested with 8/20µS pulse as defined by
IEC 61000-4-5
8
GAS DISCHARGE
TUBES
• SAD ensures short circuit failure mode in the event of severe
transient overload.
• Thermal failsafe.
Applications:
• MDF protection
• Alarm panels.
• ADSL equipment.
• XDSL equipment.
• General Telecom Equipment
a
b
e
3 ELECTRODE GDT
a=TIP
b=RING
e=GROUND
(centre electrode)
All dimensions in mm
GRAPHICAL SYMBOL
Mechanical Specifications:
ORDERING INFORMATION
Weight:
Materials:
SL 1122 A
Voltage
Device Marking:
w w w. l i t t e l f u s e . c o m
2.7g (0.095 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
Littelfuse ‘LF’ logo, voltage and date code
347
Gas Discharge Tubes
High Performance Alpha Range
RoHS
Greentube™ SL1122A Series Hybrid Gas Plasma Arresters
®
LITTELFUSE 3 TERMINAL ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL BREAKER VOLTAGE
DC
Part Number Voltage
(V)
Max
Max
Repetitive
Repetitive
Max
Alternating Insulation
Max Dynamic
Nominal
Impulse
Impulse
Breakover
Holdover On-State
9
Breakover
Discharge
Capacitance
8
1,2,4
3
Resistance
Discharge
Discharge
4,6
Voltage
Voltage Voltage @
Voltage @
Current
(pF)
1 kV/us (Vbr) Current4,7 (kA) Current5,7 (kA)
(V)
(V)
(Ω)
(A)
1A (V)
SL1122A090
90
70-120
SL1122A200
200
140-250
SL1122A230
SL1122A250
230
SL1122A260
SL1122A350
SL1122A450
200
50
20
1x10 @ 120V
100
120
20
5
1x108 @ 150V
100
135
20
10
5
1x108 @ 150V
100
135
20
10
5
1x108 @ 175V
100
135
20
5
10
5
1x10 @ 265V
100
135
20
5
10
5
1x108 @ 350V
100
135
20
150
250
5
260
184-276
200-300
210-350
10
5
1x108 @ 50V
5
10
5
350
5
10
400
5
400
5
350
280-420
600
450
420-600
700
250
8
8
Notes:
(1) Measured using a voltage rate of rise of 100V/s.
(2) In ionized mode
(3) Tested according to ITU-T Rec.K.12
(4) Either end electrode to center electrode
(5) Total current through center electrode, both line electrodes subject to simultaneous pulses
(6) 10 shots, AC 60Hz, 1 sec duration
(7) 10 shots, 8/20µs waveform
(8) Measured @ 100V
G.D.T. ONLY
(9) Measured at MHz, line to ground
CCT DIAGRAM
HYBRID
348
w w w. l i t t e l f u s e . c o m