LITTELFUSE SL1021A350

Gas Discharge Tubes
High Performance Beta Range
RoHS
Greentube™ SL1021A Series Gas Plasma Arresters
Pb
®
The SL1021A series offers high levels of performance on fast rising transients in the domain of 100V/µS to 1KV/µS, which are
those most likely from induced Lightning disturbances. The
SL1021A series also features ultra low capacitance (typically 1pF
or less) and optimised internal geometry which provides low
insertion loss at high frequencies, so are ideal for the protection
of broadband equipment. These devices are extremely robust
and are able to divert a 10,000Amp pulse without destruction.
FEATURES
• RoHS compliant except ‘RS’ suffix
• Low insertion loss
• Excellent response to fast rising transients.
• Ultra low capacitance.
• 10KA surge capability tested with 8/20µs pulse as defined by
IEC 61000-4-5
8
• 20,000 A single shot surge capability tested with 8/20µs
GAS DISCHARGE
TUBES
pulse as defined by IEC 61000-4-5
• Available with thermal failsafe option
(add ‘F’ or ‘S’ suffix to part number)
• ROHS Compliant
Applications:
• Broadband equipment.
SL1021A xxxC
• ADSL equipment.
SL1021A xxxR
• XDSL equipment.
• Satellite and CATV equipment.
All dimensions in mm
• General telecom equipment.
a
b
9.5 MAX
ø8.0+
_0.2
e
3 ELECTRODE GDT
a=TIP
b=RING
e=GROUND
(centre electrode)
GRAPHICAL SYMBOL
ø1.0+
_0.2
SL1021A xxxRF
SL1021A xxxRS
ORDERING INFORMATION
SL 1021 A
Voltage
Mechanical Specifications:
Pin Configuration
C=Core
R=Leaded
Failsafe Optio n
F=Plastic
S=Solder
Weight:
Materials:
Device Marking:
w w w. l i t t e l f u s e . c o m
2.7g (0.095 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
Littelfuse ‘LF’ marking, Voltage and
date code.
335
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1021A Series Gas Plasma Arresters
®
LITTELFUSE 3 TERMINAL ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
DC
Breakover
Voltage
DC Voltage
@ 100V/sec Min-Max
(V)
(V)
Part Number
Max Single
Max
Max Single
Max
Single
Repetitive Impulse
Impulse
Alternating
Impulse Discharge
Discharge
Impulse
Discharge
Discharge Current
Current
Discharge
Current1,3
Current8 10/350µs5 Life Test
8/20µs5
Current
Rating2
(A)
(kA)
(kA)
8/20µs1,4 (kA)
(kA)
100 shots
10
40
20
10
2.5
100 shots
10
40
20
10
2.5
DC
Dynamic
Breakover
Voltage @
100/µs (V)
SL1021A145
145
116-174
500
SL1021A150
150
120-180
500
SL1021A2006
200
150-250
350
10
10
20
40
2.5
100 shots
SL1021A230
230
184-276
350
10
10
20
40
2.5
100 shots
SL1021A250
250
200-300
400
10
10
20
40
2.5
100 shots
SL1021A2607
260
210-310
420
10
10
20
40
2.5
100 shots
SL1021A300
300
240-360
450
10
10
20
40
2.5
100 shots
SL1021A350
350
280-420
500
10
10
20
40
2.5
100 shots
SL1021A400
400
320-480
550
10
10
20
40
2.5
100 shots
SL1021A420
420
345-500
600
10
10
20
40
2.5
100 shots
SL1021A450
450
360-540
650
10
10
20
40
2.5
100 shots
SL1021A500
500
400-500
700
10
10
20
40
2.5
100 shots
SL1021A600
600
480-720
850
10
10
20
40
2.5
100 shots
(1) Total current through center (ground) electrode, both line electrodes pulsed simultaneously; half value through
each respective line terminal.
(2) 100 amps, 10/1000µS pulse (does not apply to SL1021A200)
(3) 10 shots, A.C. 60Hz, 1 sec duration.
(4) 10 shots, 8/20µS waveform
(5) either end (line) electrode to centre (ground) electrode
(6) Meets the requirements of BT Type 21A.
(7) Meets the requirements of BT Type 14A. Addition of ‘F’ (failsafe) option meets the requirements of BT type
number 14A/1.
Voltage vs Time Characteristic
Time vs. Current for Failsafe
50
Max dynamic breakover
voltage
45
40
35
Voltage
(V)
30
(s)
25
20
15
Hold-over voltage
10
5
On-State voltage
0
0
0
200
400
600
Time (ns)
336
800
1000
1200
1
1 line to ground
both lines to ground
w w w. l i t t e l f u s e . c o m
2
3
Current
(A)
4
5
6
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1021A Series Gas Plasma Arresters
Profile for reflow soldering
®
Profile for wave soldering
250
300
225
T 1 max = 266oC
Solder
Flow Area
175
150
T 1 = 239oC
125
100
200
75
Temperature (˚C)
50
25
0
0
50
100
150
200
250
300
Time in seconds
350
400
450
Tm = 179oC
Forced Cooling
Preheating
Area
500
100
8
10
20
30
40
Time(seconds)
Notes:
T1 max
T1
Tm
Tamb
= Maximum TabTemperature = 266oC
= Flow Tempearture of Solder = 239oC
= Melting Point of Solder = 179oC
o
= 25 C
o
Maximum permissible rate of temperature change = 7C / sec
w w w. l i t t e l f u s e . c o m
337
GAS DISCHARGE
TUBES
Temperature ˚C
200
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1021B Series Gas Plasma Arresters
®
The SL1021B series offers high levels of performance on fast rising transients in the domain of 100V/µS to 1KV/µS, which are
those most likely from induced Lightning disturbances. The
SL1021B series also features ultra low capacitance (typically 1pF
or less) and optimised internal geometry which provides low
insertion loss at high frequencies, so are ideal for the protection
of broadband equipment. These devices are extremely robust
and are able to divert a 20,000Amp pulse without destruction.
FEATURES
• RoHS compliant except ‘RS’ suffix
• Low insertion loss
• Excellent response to fast rising transients.
• Ultra low capacitance.
• 10KA surge capability tested with 8/20µS pulse as defined by
IEC 6100-4-5
• 20,000 A single shot surge capability tested with 8/20µs
pulse as defined by IEC 6100-4-5
• Available with thermal failsafe option (add ‘F’ or ‘S’ suffix to
part number)
Applications:
• Broadband equipment.
• ADSL equipment.
• XDSL equipment.
SL1021A xxxC
• Satellite and CATV equipment.
SL1021B xxxR
• General telecom equipment.
All dimensions in mm
a
b
ø8.0+
_0.2
9.5 MAX
e
3 ELECTRODE GDT
a=TIP
b=RING
e=GROUND
(centre electrode)
GRAPHICAL SYMBOL
ø1.0+
_0.2
SL1021B xxxRF
SL1021B xxxRS
ORDERING INFORMATION
SL 1021 B
Mechanical Specifications:
Voltage
Weight:
Materials:
Pin Configuration
C=Core
R=Leaded
Failsafe Optio n
F=Plastic
S=Solder
338
Device Marking:
w w w. l i t t e l f u s e . c o m
0.63g (0.022 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
Littelfuse ‘LF’ marking, Voltage and date
code. Blue.