GHPT SERIES Planar Transformers Power Planar Transformer for HV Systems Features - High Power & Low profile transformers - Easy-assembly system for cold plates - Power rating up to 16kW - Frequency range : 70-120kHz - H class component for operation up to 180°C 0QFSBUJOHUFNQFSBUVSFGSPN$UP$ - Vacuum potted solution for high isolation - Solution with heatsink available - Threaded output terminals - UL94V-0 material - RoHS compliant Application - Industrial high power SMPS - Rapid Chargers for EV Electrical specifications Part Number Input Output Output Power Frequency Duty Voltage Voltage Current (W) (kHz) cycle Vdc (V) (V) (A) Topology (*) Leakage Turns Inductance Inductance Ratio (mH) (µH) (Pri:Sec) Max Total losses (W) GHPT-001 360-440 34 200 6.8 100 0.47 ZVS Full Bridge 0.8 1 8:2 18 GHPT-002 800-900 520 23 12 120 0.42 ZVS Full Bridge 0.6 1 15:10 22 GHPT-003 230-340 500 32 16 70 0.4 Full Bridge 0.4 1 4:11 35 (*) ZVS Full Bridge topology with 4-diodes rectification Notes (1) All test data are referenced to 25°C ambient temperature (2) Continuous operating temperature range must be within -40°C/+125°C (ambient + self heating) under worst case conditions; exposure to 180°C peak is allowed. Thermal index H for all raw materials used (3) Performances are subjected to change according to cooling capability of the cold plate where the component is fixed. It is suggested to test the component at system level to verify its temperature rise after 30 minutes in the end application. (4) Inductance values are measured at 10kHz/1V (5) Hi-pot test between winding and between primary winding to core is above 5kV/50Hz/2sec 184 GHPT SERIES Dimensions Planar Transformers Power Planar Transformer for HV Systems Electrical Diagram 185