ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 5x20 Fuse Product #: 977 series Issue Date: May 01, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (2011/65/EU – recast of EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Specialist> (1) Parts, sub-materials and unit parts This document covers the 5x20 Fuse RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts Raw Material Part Number 1 909532 2 692529 3 692539-002 4 087355 5 C910510 6 910-555 (replaced C910541) 7 311.7374.5000 8 648901 9 082xxx-001, 687xxx-001 10 004xxx 11 082xxx 12 030204, 934-077 13 030204, 934-077 Raw Material Description Body Solder Solder Glue Cap Cap Filler Yarn Wire Wire Wire Overcap - Cap Base & Plating Overcap - Wire Base & Plating 2 Page(s) 3-31 32-36 37-41 42-45 46-49 46-49 50-56 57-63 64-68 69-74 75-79 80-83 80-83 T€stReport No.SHAEC1216714738 Page1 ol5 Date:25 Sep 2012 CO.,LTD MATERIAL SOLDERING&BRAZING ASIAGENERAL ZHEJIANG CHINA PROVINCE' CIry' ZHEJIANG, HANGZHOU PARK,SANDUN, XIHUINDUSTRIAL SoLDER The following 6ample(s)was/were submittedand identifiedon behalf of the clients as : LEAD-FREE WIRE Dateof Sampl€Received: TestingPeriod: TestR€quested: - SH sP12-028285 YTW2O6 sno.3Ag0.7ouce 21 Sep2012 21 s,ep2012- 25 SeP2012 Selectedtest(s)as requestedby client TestMethod: Pleasereferto nextPage(s) T€stResulb: : Condusion Pleasereferto nextPage(s). Baa€don the perfomedtestson submittedsamples'the resultsof Lead' (PBB)' biphenyls chomium,Polybrorninated Hexavalent I\rercury, Cadmium, RoHS by limits as set with the diphenylethe6 (PBDE)comply Polybrominated 200295/EC Annexll; recasting 2011/65/EU Di.ective SGSJobNo.: PartNo.(PN) : Compositlon: Signed for and on b€half of scs-csTc Ltd. /Qv'' .n#ffiffi Fan Jingiie,JJ Approved Signatory irmr r* u-ra -td *vot tirtDafi$EE|ihtltrorr il.t.|.*f,Ertr€€.lt$l rmrr.t.t t* zxtao ll@3 tErEl@llitldt6!E{ti"clt06t'9 Kr(,-tt)Eaffi xr.c+rti el iLnlirotllt ffior*ofr 1j!ltorSOSOtbt4 (aGS8A) T€6tReport No.SHAEC1216714734 Date:25 Sep2012 Page2 o15 TestResults: ; TestPertDe€criotion S@rn6n No, 1 D6ctiptioi SGSSampl€lD wire SHA12-167147.035Silvery Rgmarks: (1)1 mg/kg=I PPm=00001% Limit (2)MDL= MethodDeteclion (3) ND = NotD€teded( < lrDL ) (4) '-' = NotRegulated RoHSDllBdivs201l/85/EU Test Llethod with referenceto lEc 62321:2008 (1)Determination of cadmiumby ICP-oEs. (2) Dete.mination of Leadby ICP-oEs (3) Determination of Mercrlryby ICP-OES. (4) Determination Chromiumby Spottest/ Colorimetricl\,ethodusingUV-Vis of Hexavalent by GC-[IS. (5)Detemination PBBS i PBoES of Limit 100 1000 1000 Test ltem{s) Cadmium(Cd) Lead (Pb) Mercuryfig) HexavalentChromium(Ci(VD) UlE mdkg ms/kg ms/kS mS.ftS mS/kS mdkg mdkS mSikS mdks ms/kg mg/kg mdkS msikg mdks mgftS mg/KS 1000 - Sumof PBBS Monobromobiphenyl Dibromobiphenyl Tribromobiph€nyl Tetrabrornobiphenyl PentabromobiPhenYl He/€bromobiphenyl HeptabromobiPhenyl Octabromobiphenyl NonabromobiPhenyl DecabromobiPhenYl SumoI PBDES ether Monobromodiphenyl 1m0 - 5 5 s 5 5 5 5 5 5 5 5 ND 50 ND N€gative ND ND ND ND ND ND ND ND ND ND ND ND ND ffi ffiffi:ffi g"fff ###f rffi !#,g;"EHT* *,Hffi ffi Stift Ufi *lvl*sm.1m*ts""nr* #ffi*,rx*$'#'ffi Ij*tffi b D.r. na co{d6 ;;bii*hEni-.6fr l\rDL 2 2 2 o Sffi*ff d tbtk *r I r6tr.{.)r-H tt-ErrlFYasft.cxd|lt.9|dlcrn +l -l|.*tr[lt|fte||6+l zfrlr3 lr:2@ tElEF{lF6tl rd€6+1)6r.@ Hit!-2l164@raa it{&aFl@ (8cgs ) lr.nD.t o1$.8GgOrouP Tes{Report No. SHAEC1216714738 Test ltem(s) Dibromodiphenylether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl elher Hexabromodiphenyl ether Heptabromodiphenyl ether Oc-tabromodiphenyl ether Nonabro.nodiphenyl ether D€cabromodiphenyl ether thi! Date:25Sep2012 UdT MDt mdkS mdkS mdkS mdkg mS/kg mSikS mg/kg mS/kS mgkg 5 5 5 5 5 5 5 5 5 Page3 of 5 @ ND ND ND NO ND ND ND ND ND Notes : (1) The maximumpermissiblelimitis quotedfromdiredive2011/65/EU, Annexll (2) ospot{est: Negative = Absence of Cr(Vl) coating, Positive= Presenceof Cr(Vl) coating; CIhe tested sample should be fudher verifed by boiling-waterextractionmethodif the spot test result is Negative or cannot be confirmed.) oBoiling-wateFextraction: Negative = Ahsence of Cr(Vl) coating Positive = Pesence of Cr(Vl) coating;the detectedconcentrationin boiling-water-ext€ctionsolution is equal or greater than 0.02 mgl(q with 50 cm'zsample surtace area. For corrosion protectioncoatingson metals: Informationon storage conditionsand producliondate of the tested sample is unavailableand thus results of Cr(Vl) representstatus of lhe sample at the time of testing. t'ilt,b.aYrbto +1 drchrbrd,Swaon !e3a I ErE{O-Zr)OtrOO raEFaFffiTl *FA)ala@!.a |{j{l.?J)6r@ M.m!.rorh.scsGtuc(acgs ) TestReport No.SHAEC1216714734 Page 4 of 5 Date:25 S€p2012 ATTACHMENTS RoHSTe€tingFlowChart xu Xiao/Gary Wang/Allen JanShi/Yoyo 1) Nameof the personwhomadetesting: Xu/LindaLi ' 2i Nameof thebersonin chargeof testing:JeffZhang/George chart.(Cf to berowflow accorcting 6'ypre-condit-roningherhod totarry aissoried iiiii,"i !!rir!!,i. testmethodexcluded) andPBBdPBDES SamplePrcparation SampleMeasurement Pbrcd,Hg PB86fPBDE8 Acid digestionwith microw€ve/hotplate Concentration/ Dilutionof extraclion solution '1)AlkaliFusion/ DryAshing 2) Acidto dissolve Adding1,s diphenylcarbazide for color development A red color indicatesthe presence of cP'. neceas€ry, confirmwith tr 'l';-;Ltidbd$rffi'd6.h*lhE.,nrdri*6 tilairl$gYb.rto dErloat4ltrtracnr 20(43 a|lM fl..tjt.*Iqldl|6els+l rEtEFzr)0tac53 rE&&4lrsa l+{a-a)dlqaa rtjF.?1)6@ $6nb.fol th.ao6 GlDlD{8oas ) TestReport No.SHAECl2'16714738 Date:25 Sep2012 Page5 of 5 Samplephoto: sHA12-167147.035 SGSauthenticato the photoon originalreportonly '* Endof Report"" (d-l!r. .Dor -iibhihr.ldcn.h, '|l!!a|i!!{l|ddbd' ,td.lwb|||d4ded tLlliDl! Bftfiufition tr.tl.*tr6l||,|rF|6r+l 2dEs ll: @3 rElE[6-eDdag6l lElfF2l!ffia rr{&a1}ara@a ttF+lFN d6.ccil *6r*.& .,9d'rt.l.- l|.fiDcrolm. SOSGtu,D|SOSS ] TestR€port No.SHAEC1216714750 Date:25 Sep2012 Page'l ofs ZHEJIANGASIAGENERALSOLDERING&BRAZING MATERIALCO.,LTD XIHU INDUSTRIALPARK,SANDUN,HANGZHOUCITY,ZHEJIANG,PROVINCE, CHINA Thgfollowing sample(s) was/were submitted andidentifed on beharf of thedientsas : LEAD-FREE soLDER WIRE SGSJobNo.: PartNo.(P/N): Composition : Dateof SampleReceived: TestingPeriod: Te6tRequested: - SH sP12-028285 YTWl02 (692s39-002) Sn2.0CuRE 21 9ep 2012 21 Sep2012- 25 Sep2012 Selectedtest(s)as requestedby dient. TestMethod: TestResults: Pleasereferto nextpage(s). Pleaseref€rto ne\4page(s). Basedonthe performedtestson submittedsamples,lhe resultsof Lead, polybrominated Mercury, Cadmium, Hexavalent cfiromium, biphenyls (pBB), Polybrominated diphenylethe6 (PBDE) compty withthetimibas setby RoHS Direclive 2011/6yEU Annexll; recasting 2OO2|95/EC. Conclusion : Signedfor and on b€halfof scs-cgTcLtd. ,z?r"'- FanJinqjie,JJ ApprovedSign€tory rhb d@Dnr b rFr.c |r nr k'{l efir C.nddd.l6.rno odd- osLd, w.r.l'lr 6Mnd t n lle u! a.Ddr'rE iq Eldimo o.uffi . w*dh,|od !l|dn. rry ndr..rttr' rtr'eddr d*dihndofidd . t4. rn corulrr * rybh mh|trllltflunarl&i'.9ilob fl'I|.*f,61'|r|db+3*ll d..qrb k ..d..llfu.h-.Aldfiriirmr;iitrffia ri.blFondnnr rmpr.(r, rnbd . 2o@q fi:M tn€Fa)filG60lEEiE-ArOSI9 rllj{E-ar)6140,,0att{fi-21l6ao@ *n.nrslcdn .tdir&lilcn Man!6rorrh€sqs olo!! (scs sA) TestReport No.SHAEC1216714750 Date:25Sep2012 Page2 of 5 TestResults: TestPartDesciiotion: Sp€oim€nllo. 1 SGSSampl€lD Dcc,ipdon SHA12-167147.043Sitvery wire RemarlG: (1)1 mgftg=1 PPm=0.0001% (2)IVDL= MethodDetedionLimit (3) ND= NotDetected( < l\4DL) (4) "-" = NotRegulated RoHSDir€divo2011/85/EU Testl\rethod: Withreferenc€ to IEC6232'1:2008 (1)Determination ofCadmium by ICP-OES. (2)Determination of Leadby tCp-OES. (3)Determination of Mercury by |CP-OES. (4) Determination of Hexavalent Chromiumby Spottest/ Cotodmetric MethodusingUV-Vis. (5)Determination of PBBS/ PBDES by GC-MS. Te6t ltem(s) Cadmium(Cd) Lead (Pb) Mercury(Hg) HexavalenlChromium(Cr(Vl)) Sumof PBBS Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabrcmobiphenyl Pentabromobiphenyl !!!it Ud! 10O 1000 mS/kS mSikg 1000 - mdkg mgKg mgKg mgKg mgKg mg/Kg ms/Ks mg/Kg mg/Kg mS/kS mgKs mdkS meyKg 1To 'nT - Heptabromobiphenyl Oclabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sumof PBDES Monobromodiphenyl ether 1000 - l\4DL @3 2 N D 2 168 2 N D O Negative N D 5 5 5 5 5 5 5 5 5 5 - N N N N N N N N N N N D D D D D D D D D D D 5 N D rn .dothr,$rLbhdtuFl c!dr-/. dnr ncr.|'ld & qi.r rdta dsn-r m.rr.ddaDlhMllln.d'lddtl.' i'drbdn'l''hcd'c'|i&dcmdr. h dr hi rPd Dt' cir b,h. rm, t'inr$r$fedrdrr6nl,gEidaorr +l..t.t.lr6ldrl33oClstn .b, hro . 2o@3] ll:M ndhl. .rtrrhd Fdr b. hnr.dm lElE{S-Al6ia02563lElEls-a!ffiIg rL{6-nl6|102ra rrlr{6-?r)5ae3 9w.64a.m .€.d't!0.tM .mb.rol rh. scs Goup{8Gs€ } TestReport No.SHAEC1216714750 Test ltem(s) Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Psntabromodiphenyl elher H€xabromodiphenyl ether Heptabromodiphenyl ether Octabomodiphenylether Nonabromodiphenyl elher Decabromodiphenyl ether udt Lldl ms/Ks mg/Kg mg/rg mS/kg mg/Kg mg/Kg mg/Kg m9Kg mdkg Datei25 Sep 2012 upt 5 5 5 5 5 5 5 5 5 Page3 of 5 a3 ND ND ND ND ND ND ND ND NO Notes: (1)Themaximum permissible limitis quotedfromdirective 2011/65/EU, Annexll (2) "spottest:= Negative Abs€nceof Cr(Vl)coating,Positive= Presenceof Cr(Vt)coating; methodif the spottest result Cfhetestedsampleshouldbefurthervedfiedby boiling-wateFextraction is Negative or cannotbeconfirmed,) oBoiling-wateFextraction: Negative= Absenceof Cf(Vl)coating Posilive= Presenceof Cr(Vl)coating;the detectedconcenhation in boiling-water-extraclion solutionis equalor greaterthan0.02mg/kgwith50 cm. samplesurtac€area. For@rosionprotection coalings on metals:Infofmation onsto€geconditions andproduction dateof thetestedsampleis unavailable andthusresultsof Cr(Vl)represent statusofthesampleat thetime of testing. n6.hffi hft *4dntuorrbrh rrh..(.)r-rd. f 6illselb'b.dld$0|..dlirdtqrr lFt.-Ll.*tr6ltl€o!l6r}| @ l|:a@3 TEEFZT)tll66! IBEFA)6*$,D Hr (a-at614qer Hj F-a)fl@l w6|a.M . ttdhl&s@ M.m!.t olrhsaGsololp (aagsA) TestReDort No. SHAEC1216714750 Date:25 Sep2012 Page 4 of 5 ATTACHMENTS RoHSTesflngFtowChart 1) Nameof the personwhomadetesting: JanShi^/oyoWangr'A enXao,caryXu z) N€meortnepersonin chargeof testing:JeffZhang/ceorge Xu/LindaLi r) Inesesampres w€redissotved tota v bv ore-conditioning methodaccording to belowflowchart.(Cr6' andPBBS/PBDES testmethodexctudedi Pb/Cd/Hg PBBs/PBDEs Aciddigestion with microwave/hotplate Nonmetallic matedal 1)AlkaliFusion/ DryAshing 2) Acidto dissolve Filtration andpH adjustment Addang 1,5diphenylcarbazide for color development rn. .@md e -.,r!!5ffi I h.!d byri.6oF / E[i-r tu &mil&hFd b r. ord codl|dr b rm. rn c.dtu rd.r[f,t n6.hffi 6dr oi s k d Ddod@nFr!. Adding1,5diphenylc€rb€zide for color development A redcolor indicatesthe pre6enceof cr6*. lf necess€ry, confirmwith r.{dMrffi. Thb drsrud d!.r b.6rmdr..d *ror 6 nrr,$,l.d N.ris,.4jwr d tn.c.ffiv bdnFdrhci,rb'brn!.h,'orc ratUlle.|lrto tr.hrt*€rthccfar +l..ti.tiEEtufta9+sltt tt: zci@33 2r@s lElE(6?r)6140at63tE!Et6{l)0'tE17t m.6r€..m .tasr'..Cc.6 EtB-?)6r102r1 iL(ri-?r)A!G3 Urmllr ol |h. AgAelou! (gGSSA) TestReport No.SHAEC1216714750 Date:25 Sep2012 Page5 of 5 Samplephoto: sHA12-167147.043 reportonly SGSauthenticate thephotoonoriginal "' Endof Report"* tt-!,ruaYanbrrrr&id,$.'icti +r'rr.*Jr8ltlsae'{33|t 2tEf3 3L M tErEF.e0E @ rEtE16*r)af5rr9 Hj{t-aldlML fU0SAl)64e0 lrom!.r ol rh.8og Group(8G€S ) AOV"BPFS,U TESTREPORT R02 NO.:4002R12100802+1 Dare:ocr.10,2012 Customer:SuzhouFuHongElectronjc InduslrialCo., Lld. XIANGCHENG DlsTRlCT, SUZHOU, CHINA Addres!:NO.89WEIDUROAD,WANGTINGTOWN, to be Reporton ths submitreds.mplesald S.mplename:CoppeJ,shell Mod€h/ Item/LoiNo.:/ Metarlal:/, Buyer: / , Suppli€r:/ Samplorecaivsdd.te: Ocl.08.2012 1o'O4r'10, 2012 Testinsperiod:Ffomoct os,20!€ '\l ' . . ,, E9S!.s-Ecs!ed9!f samplein Chrcmium contentin thesubmitled & Hexavalent As specifiedby dient, to determineihe Lead,cadmlun, Mercury accordancewith Dircctive2002/95/EC{RoHS). Ec!!!s-ee$9!.: instrumeni I\4QL Measunng Testingltem (cd) Cadmium (Hg) [4ercury IEC62321:2008,s€ction9 |EC62321: 2008,seclionI 7 lEc 623212008,seclron Chromum(Cr\rl) IEC623212008AnnexB Lead(Pb) ICP€ES 2-'nglkg ICP-OES 2 mg/kg tcP-oEs 2 mg/kg 0.02m9/k9' Ieq r 0.02mg/kgreE|sto theMQLofsampleextfaction liquid SsElcge!: Decision ol 18 Aug 2005 of commission withthe requirements -whentesledas speci{i€d samplecomplied the submitted 2005/618/Ec noiiliedunderdocument 2002/95/Ec Directjve amending ILS,PLEASEREFERTOTHE FOLLOWNGPAGE(S)*** signedlor andon behalfof Brcncn Co.,Ltd,Kunshan Technology Shenzhen AOVTesling We-r k] n **n*"oor, /blfil caeateaaer: LiTingting,Maggie ooo,',*or44. Ylan Qi, lrickey Chemic€lTestDirecror S I t E N 2 H E NA O V T f S I I N G T € C H N O I , O 6 YC O . , I " T O . K U N S N ABNR A N C T I , /// \ Noll ne Ja,t 7tt) 9€'t'o AOV'*F#S,[ TESTREPORT NO.:4002R121008024-1 R02 Oate:Od.10,2012 1. To Determiney'.ead, C€dmium Contenli(Metalsubslrate) I*redby (y'a04* Weighihe sampleinto Add ihe digestionsolulionithe vesselis heatedunlilthe sample AddHrOruntilthe sampleis clear nlter;washed and Cooling thevess€|, Rlled wat€r. 10themarkwithdistill€d To Dete sulit€le) Content i|retb.r . \ . The sampleis digestedin the Weighihe sample microwaveovenfollowinga specific decomposrlonprogram Tested by lcP-oES Coolingthe vessel,tiltei washedand filledlothe maiKwilh dislilledwater. ChromiumContenl(boiling-wat€F€xtlaclion):([4etalEubstrate) Takethe (50i5) cm, samplein the beaker. Heat50 mLof Olwaterin thebe6ker to boilingfor 1o F;;1.- lhe sample, andcool Remove thebeak€rto roomtemperature, anddo thecolorreaction Testthe samplesolutionand lhe 0.02 ng/kg standardsolltion by uv-vls. BSANCH lCCINOLOGYCO.,LTD.KUNSIIAN SH€NZH€NAOVTESTITIG (: Hotlrne 'tL)0700 8600 nov'Bpf,F,il TESTREPORT NO.: 4002R121008024-1R02 Daie:Ocl.10, 2012 5. TooetemineHexavalenl Chromium Contonlin colorlessand coloredchromatecoatingon metats:iPtating) _ .. -i\ : va'hu't' lfthe lest resultis positive, the sample is consideredto havehexavalent chmmium Place 1-5 Boiling- water- extraotion procedu€shallbe usedto and the 0.02 mg/kg lflhee is interference or it is hardto decide whetherlhesamplehavelhe hexavalent 5.2Boiling-wateF enradion Remove thesample, andcool thebeaker lo roomtemperalure, anddolhe colorreaction Heat50 mlof Dlwaier in the samplein thebeaker. beakerto boilingfor 10 min Testtnesamplesolution andlhe0.02 mg/kgstandadsolulion by UV-VIS. SampleDelcriptlon: Code 1-1 SampleDescndion Substrate Plating Te3tR63ulb: Unit RoHSLimit Lead(Pb) msfts 1000 N.D. 10 (Cd) Cadmium Merorry(Hg) mg/K9 N.D. ms/Kg 100 1000 N.D, N.O. N.D. Chromium {Crl,ll) m9/kg 1000 Negative Negative s8€NZh€N AOVT€SrtNGTECHNOlOSYCO,,tTD,TUNSHAI! ARANCH ,.r Ho t l i ne .100700B6a0 nov'F"Ff"qn TESTREPORT No.:A002R1210o602:L1 R02 -ThenewRoHSdircclive 2011/6tEU,on Jul.21,2011comeintoforc€,onJan.03,2013lheformalimplementation, Direclive repealed 2002r'95/EC simultaneously. ahallbe Sp€cimens, whichr€Slested lo detemineLead,Cadmium havebeendissolved andMercury Content, completely, -mg/kg=ppm , -N.D.=not i",,,,,, ( The iested sample resultis uncertain or neoatve., -"The te8t is bas€d on lhe followins d!!{mplifi: maybe cannot stand lor the physical lrdh 6t s€r Coppershell SH€NZII AFANCH AOVTIST|n|GTECHNOIOCVCO.,ITD.KUNSHAN Ho t l i ne 400 /00 8600 TEST REPORT APPLICANT: NUMBER: LITTELFUSE,INC. 800 E. NORTHWEST HWY ATTN: A.DIVIETRO/D.UNTIEDT DATE: SHAH00355832 DEC 13, 2012 SAMPLE DESCRIPTION: ONE(1) SUBMITTED SAMPLE SAID TO BE BROWN SAND. ITEM NAME : SAND. PART NO. : 311.7374.500. ***************************************************************************************************************************************************** TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S) ***************************************************************************************************************************************************** TO BE CONTINUED AUTHORIZED BY: FOR INTERTEK TESTING SERVICES LTD., SHANGHAI JACOB LIN GENERAL MANAGER PAGE 1 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED 1 (Ⅰ) TEST RESULT SUMMARY: TESTING ITEM HEAVY METAL CADMIUM (Cd) CONTENT LEAD (Pb) CONTENT MERCURY (Hg) CONTENT 6+ CHROMIUM VI (Cr ) CONTENT POLYBROMINATED BIPHENYLS (PBBs) MONOBROMINATED BIPHENYLS (MonoBB) DIBROMINATED BIPHENYLS (DiBB) TRIBROMINATED BIPHENYLS (TriBB) TETRABROMINATED BIPHENYLS (TetraBB) PENTABROMINATED BIPHENYLS (PentaBB) HEXABROMINATED BIPHENYLS (HexaBB) HEPTABROMINATED BIPHENYLS (HeptaBB) OCTABROMINATED BIPHENYLS (OctaBB) NONABROMINATED BIPHENYLS (NonaBB) DECABROMINATED BIPHENYL (DecaBB) POLYBROMINATED DIPHENYL ETHERS (PBDEs) MONOBROMINATED DIPHENYL ETHERS (MonoBDE) DIBROMINATED DIPHENYL ETHERS (DiBDE) TRIBROMINATED DIPHENYL ETHERS (TriBDE) TETRABROMINATED DIPHENYL ETHERS (TetraBDE) PENTABROMINATED DIPHENYL ETHERS (PentaBDE) HEXABROMINATED DIPHENYL ETHERS (HexaBDE) HEPTABROMINATED DIPHENYL ETHERS (HeptaBDE) OCTABROMINATED DIPHENYL ETHERS (OctaBDE) NONABROMINATED DIPHENYL ETHERS (NonaBDE) DECABROMINATED DIPHENYL ETHER (DecaBDE) RESULT (ppm) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND REMARKS:ppm = PARTS PER MILLION = mg/kg ND = NOT DETECTED RESPONSIBILITY OF CHEMIST: DENT FANG / LEAF LIU (Ⅱ) ROHS REQUIREMENT: RESTRICTED SUBSTANCES CADMIUM (Cd) CONTENT LEAD (Pb) CONTENT MERCURY (Hg) CONTENT 6+ CHROMIUM VI (Cr ) CONTENT POLYBROMINATED BIPHENYLS (PBBs) POLYBROMINATED DIPHENYL ETHERS (PBDEs) LIMITS 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) THE ABOVE LIMITS WERE QUOTED FROM ROHS DIRECTIVE 2002/95/EC AND AMENDMENT 2005/618/EC FOR HOMOGENEOUS MATERIAL. ***************************************************************************************************************************************************** TO BE CONTINUED PAGE 2 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED (Ⅲ) TEST METHOD: TESTING ITEM TESTING METHOD WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED CADMIUM (Cd) CONTENT SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED LEAD (Pb) CONTENT SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE MERCURY (Hg) CONTENT 7, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN ANNEX C, 6+ CHROMIUM VI (CR ) BY ALKALINE DIGESTION AND DETERMINED BY UV-VIS CONTENT SPECTROPHOTOMETER. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN ANNEX A, POLYBROMINATED BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD BIPHENYLS (PBBs) AND FURTHER HPLC CONFIRMATION WHEN NECESSARY. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN ANNEX A, POLYBROMINATED BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD DIPHENYL ETHERS (PBDEs) AND FURTHER HPLC CONFIRMATION WHEN NECESSARY. REPORTING LIMIT 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm REMARK:REPORTING LIMIT = QUANTITATION LIMIT OF ANALYZE IN SAMPLE ***************************************************************************************************************************************************** TO BE CONTINUED PAGE 3 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED (Ⅳ) MEASUREMENT FLOWCHART: TEST FOR Cd/ Pb/ Hg/Cr (VI)/ PBBS/PBDES CONTENTS REFERENCE STANDARD: IEC 62321 EDITION 1.0:2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid No Yes Make up with deionized water Analyzed by ICP-OES Polymers / electronics PBBs/PBDEs Weigh sample and add organic solvent Weigh sample and add alkaline solution Spot test Positive Confirm the tested samples are totally dissolved 6+ Get 50cm samples *2 Definite temp. Extraction 2 Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water and add Diphenylcarbazide solution Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS REMARKS: *1: LIST OF APPROPRIATE ACID: ACID ADDED FOR DIGESTION MATERIAL POLYMERS HNO3,HCL,HF,H2O2,H3BO3 METALS HNO3,HCL,HF ELECTRONICS HNO3,HCL,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ***************************************************************************************************************************************************** TO BE CONTINUED PAGE 4 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED 2 (Ⅰ) Test Result Summary : Testing Item Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Remarks: ppm ND ND ND ND ND = Parts per million = mg/kg = Not detected Responsibility Of Chemist (Ⅲ) Test Method: Testing Item Halogen Content Remark: Result (ppm) : Grave Wang Testing Method With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography Reporting Limit 50 ppm Reporting limit = Quantitation limit of analyte in sample Date Sample Received: Dec.5, 2012 Testing Period : Dec.5, 2012 To Dec.11, 2012 ***************************************************************************************************************************************************** TO BE CONTINUED PAGE 5 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 sampling/grinding or cutting add absorbent in a combustion flask & place weighed sample in equipment fill the combustion flask with oxygen ignite then leave the flask at room temperature transfer the absorbent into a volumetric flask make up with deionized water analyzed by ion chromatography ***************************************************************************************************************************************************** TO BE CONTINUED PAGE 6 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn TEST REPORT NUMBER: SHAH00355832 TESTS CONDUCTED ***************************************************************************************************************************************************** END OF REPORT This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. PAGE 7 OF 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: Number: LITTELFUSE,INC. 800 E. NORTHWEST HWY A.DIVIETRO/D.UNTIEDT Attn: Date: SHAH00361375 JAN 16, 2013 Sample Description: One(1) submitted sample said to be White Yarn. Item Name : Glass Yarn. Part No. : 648901. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted 1 (Ⅰ) Test Result Summary: Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks:ppm = parts per million = mg/kg ND = not detected Responsibility of Chemist: Dent Fang / Leaf Liu (Ⅱ) RoHS Requirement: Restricted substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content 6+ Chromium VI (Cr ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. ************************************************************************************************************************************************************ To Be Continued Page 2 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅲ) Test Method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Testing method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-VIS Spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. Reporting limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm Remark:Reporting limit = Quantitation limit of analyze in sample ************************************************************************************************************************************************************ To Be Continued Page 3 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅳ) MEASUREMENT FLOWCHART: Test for Cd/ Pb/ Hg/Cr (VI)/ PBBs/PBDEs contents Reference standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid No Get 50cm samples Yes Weigh sample and add organic solvent *2 Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water and add Diphenylcarbazide solution Analyzed by ICP-OES PBBs/PBDEs Definite temp. Extraction 2 Boiling water extraction Make up with deionized water Polymers / electronics Weigh sample and add alkaline solution Spot test Negative Confirm the tested samples are totally dissolved 6+ Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS REMARKS: *1: LIST OF APPROPRIATE ACID: MATERIAL Polymers Metals Electronics ACID ADDED FOR DIGESTION HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ************************************************************************************************************************************************************ To Be Continued Page 4 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted 2 Halogen content (Ⅰ) Test result summary: Testing item Fluorine (F) Chlorine (Cl) Bromine (Br) Result (ppm) 350 150 ND Iodine (I) ND Remarks:ppm = parts per million = mg/kg ND = Not detected Responsibility of chemist:Grave Wang (Ⅱ) Test method: Testing item Halogen content Testing method Reporting limit With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography 50 ppm Remark:Reporting limit = quantitation limit of analyte in sample Date sample received:Jan.8, 2013 Testing period:Jan.8, 2013 To Jan.14, 2013 ************************************************************************************************************************************************************ To Be Continued Page 5 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅲ) MEASUREMENT FLOWCHART: Test for halogen content REFERENCE STANDARD:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill the combustion flask with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography ************************************************************************************************************************************************************ To Be Continued Page 6 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 7 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: Number: ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Date: SHAH00362299 JAN 18, 2013 Sample Description: Two(2) pieces of submitted samples said to be : (1) Mixed all kinds of metal substrates. (2) Mixed all kinds of plating layers. Item Name : Silver Plated & Pure Silver Wires. Item No. : (1) 101.0132.---- - silver copper alloy wire – AgCu50. (2) 101--232.0--- - tin plated silver copper alloy wire – AgCu50,Sn - -%. Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted (A) Test result of RoHS Directive: Result Testing item (1) Cadmium (Cd) content (mg/kg) ND Lead (Pb) content (mg/kg) ND Mercury (Hg) content (mg/kg) ND 6+ Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg 2 with 50cm ) ND Result Testing item (2) Cadmium (Cd) content (mg/kg) / Plating ND Lead (Pb) content (mg/kg) / Plating 20 Mercury (Hg) content (mg/kg) / Plating ND 6+ Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg 2 with 50cm ) / Plating ND 2 Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter ND = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) 6+ Chromium (VI) (Cr ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) content (for metal) Testing method With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 mg/kg 2 mg/kg 2 mg/kg 2 0.02mg/kg with 50cm (in testing solution) Date sample received:Jan.14, 2013 Testing period:Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To Be Continued Page 2 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid Positive No Confirm the tested samples are totally dissolved Yes Polymers / electronics PBBs/PBDEs Weigh sample and add alkaline solution Spot test Get 50cm samples 6+ Weigh sample and add organic solvent *2 Definite temp. Extraction 2 Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Make up with deionized water Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Polymers Metals Electronics Acid added for digestion HNO3,HCL,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To Be Continued Page 3 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted ************************************************************************************************************************************************************ To Be Continued Page 4 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Number : TWNC00294415 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Jan 17, 2013 Sample Description: One (1) group of submitted samples said to be : Part Description : Tin plated Elcon Wire Element Part Number : 0042xx/ 0063x Date Sample Received : Jan 11, 2013 Date Test Started : Jan 11, 2013 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 6 Number : TWNC00294415 Test Conducted (Ⅰ) Test Result Summary: Test Item Unit Result Test Method RL (1) (2) ND ND 2 ND 248 2 ND ND 2 Negative Negative 0.02 Heavy Metal Cadmium (Cd) content ppm Lead (Pb) content ppm Mercury (Hg) content ppm Chromium VI (Cr6+) content Remarks: mg/kg with 50 cm2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. ppm = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. Tested Components (1) Coppery metal wire base material (2) Silvery plating layer Responsibility of Chemist: Date Sample Received Test Period Kevin Liu/ Irene Chiou : Jan 11, 2013 : Jan 11, 2013 To Jan 15, 2013 *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 6 Number : TWNC00294415 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Limits Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 3 of 6 Number : TWNC00294415 Test Conducted (Ⅲ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Substrate Plating For different material, digest the sample with *1 appropriate acid Cr 6+ By spot test Confirm the tested samples are totally dissolved Make up with deionized water Negative *2 Get 50cm2 sample By boiling water extraction Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 6 Number : TWNC00294415 Test Conducted Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 6 Number : TWNC00294415 Test Conducted Photo *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 6 Test Report Applicant: Number: ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Date: SHAH0036227401 JAN 18, 2013 Sample Description: Two(2) pieces of submitted samples said to be : (1) Mixed all kinds of metal substrates. (2) Mixed all kinds of plating layers. Item Name : Silver Plated & Pure Silver Wires. Item No. : (B-1) 101.014 -. ---– silver plated copper wire – Cu, Ag--% (B-2) 101.0131.---– pure silver wire – Ag 1000 (B-3) 101.0123.0--– silver plated purest nickel wire – Ni99.98%, Ag1% (B-4) 101.0182.0--– silver-copper alloy plated copper plated iron nickel alloy wire – ElconD, AgCu5% (B-5) 101.0120.0--– silver plated constantan wire – CuNi44, Ag5% (B-6) 101.0151.0--– silver plated copper - nickel 44 alloy wire – CuNi44, Ag10% (B-7) 1050--31.-------– pure silver strips – Ag 1000 pure Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted (A) Test result of RoHS Directive: Result Testing item (1) Cadmium (Cd) content (mg/kg) ND Lead (Pb) content (mg/kg) ND Mercury (Hg) content (mg/kg) 6+ Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 50cm ) ND ND Result Testing item (2) Cadmium (Cd) content (mg/kg) /Plating ND Lead (Pb) content (mg/kg) /Plating ND Mercury (Hg) content (mg/kg) /Plating ND 6+ Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 50cm ) /Plating ND 2 Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter ND = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) 6+ Chromium (VI) (Cr ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) content (for metal) Testing method With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 mg/kg 2 mg/kg 2 mg/kg 2 0.02mg/kg with 50cm (in testing solution) Date sample received: Jan.14, 2013 Testing period: Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To Be Continued Page 2 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid Positive No Confirm the tested samples are totally dissolved Yes Polymers / electronics PBBs/PBDEs Weigh sample and add alkaline solution Spot test Get 50cm samples 6+ Weigh sample and add organic solvent *2 Definite temp. Extraction 2 Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Make up with deionized water Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Polymers Metals Electronics Acid added for digestion HNO3,HCL,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To Be Continued Page 3 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted ************************************************************************************************************************************************************ To Be Continued Page 4 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn l\OV'BF.F.q,A TESTREPORT NO.:4002R121008024-2R02 Oate:Oct.1 0,2012 Cuslomer: SuzhouFuHongElectronicIndustriatCo., 16. Addr6s: NO.89 \/ElDU ROAD,WANGTINGTOVIN,XTANGCHENG DISTR|CI SUZHOU.CHINA Repod on the submltted samrl€ said to be sample name: Leadwife coppershell Modol:/ Itefi/Lot Io.: / Matonal:/ Buyen/ Supplier:/, lilanufacturE:/-f . _ - i Samplerecelveddate: Gq 2012 : _08, : t*,tn o"n.o,t.. o".;;,,013 "."r.-,.,,613, 1 ,] i &glirs-Bgsccsgq As specifedby dienl,to determine the L€ad,Cadrium,l,tercury & tiexayabntChrcmium conle in the6ubmitted samptein accodance withDirective 2OO2I95/EC {RoHS). j Testino method: Testingltem Lead(Pb) IEC62321:2008. sectionI cadmium(Cd) IEC62321:2008, s€ction9 (Hg) [,lercury IEC62321r2008, s€ction7 (CrM) Chromium IEC62321:2008,AnnexB Measufing instrument ,MQL rcP-oEs a!gag tcP-oEs rcP-oEs 2 mg/kg 2 mg/kg 0.02mg/kg* lsq j 0.02mg/tg rctursto the MQL olsampleexlractionliquid. Conclu3ion: -\ryhentested as specifiedlhe submiliedsamplecompriedwith th€ requircmentsof commissionD€cisionof 18 Aug 2005 amendingDircctive2002/95/ECnotiliedunderdocum€nt2005/618/EC. ."*FOR FURTHERDETAILS,PLEASEREFERTOT Sign€dior and on behallol ShenzhenAOVTestingTechnology Co., Ltd,Kunshan8ran6h Walbn A?1 ea"arc"a"r, YuanQi, l,lickey LiTingting,Maggie Chemical Test Direclor OrO."*0r44 Technical Di€clor LabManager STIENZIIEN AOVTE$Tl'{GI€CHI!OLOGYCO,.I.TD,KUNSHAN BRANCI] (,10",'ll,,u* l\ov"BF,?sn TESTREPORT NO.:A0O2R12100802+2R02 D a t eO c i . 1 0 , 2 0 1 2 T63l Flow: L ToDetemine/lead, CldmiumContent(Metalsubstrale) lestedbY L7.^otq, Add the digestionsolulionjthe vess€lis heateduntilthesample Coolingthe vessel,fiitei washedand fllledlo the mafKwith distilledwaler. -*".irl,"*J "r,to,"t|, The sampleis digestedin the Addlhe digestion soluUon, close lhemicrowave vessel. micrcwaveoventollowinga specinc progrcm. deoomposilion Coolingthe vessel,frller;washedand filled to the maft wilh dislilled waler. Remove lhe sample, andcool thebeak€rlo roomtemperature, anddo thecolorreaclion -].f---- Testthe samplesolulionand ihe 0.02 mg/kgslandardsolutionby uv-vls. (Plating) nrte,.washedand ______-l l_____*p;-r, f;;-1 "*rn rilledlo$e markwithDlwaler I I ON EANCH ShENZH€N A O VI 6 S T I I { GT ' C N O I O G YC O . . I T D . X U N S H A ' Hotlrne 40a 7008600 /\OV"BF#,HN TESTREPORT NO.iA002R121008024-2R02 O a t e : O c l 1 02 0 1 2 coalingon metals:(Plating) in colorless andcolorcdchromate Hexavalent Chromium Content 5. ToDeiermine r e s t ebd'v : l ) ^, L/A^U,4. ( 5.1Spotlesl lf thelestresultis posiiive, lo ihesampleis considered chromium havehexavalenl Place 1-5 Boiling- water- lf the testreslrlt extracton procedurcshall be us€d to and the 0.02 mg/kg lltherc is intederenceor it is had to decide whetherlhesamplehavethe hexavalent water-enractron 5.2Boilin9Removethe sample,and cool Takethe (50i5)cm2 Heat50 ml ol Dl walerin the samplein the beaker. beak€rto boilinglof 10 min the beakerto rcomtemperalu€, and do the colorrcaolion Sample Doscripilon: Code Sample Desc{iplion Leadwire Plating Unit Code coppershellsubslfate CoppershellPlatng 24 Result RoHSLimit 2-3 N.O Lead{Pb) (Cd) Cadmium mg/l(g 1000 N.D. N.D. N.D. mg/k9 100 N.D. N.D. N.D, N.D. (Hg) Meroury mg/kg 1000 N.D. N.D. N.D, ND. Chromum(Crl'I) mg/K9 1000 Negalive Negalrve Negaliv€ Negative S N € $ Z H E NA O V I : S T I N G T € C N O I O G Y C O ' ' I T D . X U N S I l A NB B A N C I I f l;"')l;** TESTREPORT oare:oct.10,2012 NO.:A0O2R12100802+2R02 -:fh€newRoHSdi€ctive2011/65/EU, Direcliv€ on Jul.21,2011comeinloforce,on Jan.03,2013thsformalimplementation, simultaneously200295/EC ahallbe repeal€d Sp€cimens,whichggqeted to d€temineLead,CadmiumandMercuryconient havebeendissolvedcompletelv. -mg/Kg=ppm ceofC_rl\,I)l if"veiry/y6hetp ttef.li v meresr{.q!.be/rurTr --The iest is bas€don the following maybecannotstandfor the physicaltruth -Photois included ii'iffyiT-'' lhe spot test result is uncertainor *'q:* eachpadis unifom.Theteslrcsult Leadwir€ coppershell "'End of Repod"" SRANCIi CO.,ITDKUNSHAN AOVrlsrr'tc IECNl'lO!OeY sHEI\tZH:ir r.r i35.1J:55i0eo0o Fd.3F1t?55roEr$ hrr ,w.d{.di' Fodrdo 1r.r00 /, Hotlrne I , 400 7008600